HB G11 S

IKEA HB G11 S Program Chart

  • Hello! I am an AI chatbot trained to assist you with the IKEA HB G11 S Program Chart. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • How do I ignite the burners?
    What should I do if the burner fails to light?
    What is the purpose of the burner safety system?
    What is the nominal heating capacity of the cooktop?
    What is the total nominal gas consumption of the cooktop?
FRAMTID HGA4K PRODUCT DESCRIPTION SHEET
DE GB FR NL BE
5019 619 01342
HB G11
Operation of burners
To light one of the burners:
Press the relative knob and turn it
anti-clockwise to the large flame setting .
At the same time, press the button with the
star .
The spark plug gives out a spark that causes
the burner to ignite.
Once the burner is lit, keep the knob pressed
for about 10 seconds.
If the burner fails to light, repeat the above steps.
Note:
Should particular local conditions of the
delivered gas make the ignition of the
burner difficult, it is advisable to repeat
the operation with the knob turned to the
small flame setting .
The burner safety system serves to prevent the
emission of gas if the flame should be extinguished
accidentally (draughts, interruptions in gas supply,
dousing with liquids, etc.).
For BELGIUM: replace the gas fitting with the one
supplied (this job must be done by a qualified
technician).
1. Removable panstand grids
2-3. Medium burners
4. Large burner
5. Small burner
6. Medium burner control knob
7. Medium burner control knob
8. Large burner control knob
9. Small burner control knob
10. Electric ignition button
Symbols
Shaded circle Tap closed
Large flame
Maximum opening/
delivery
Small flame
Minimum opening or
reduced delivery
DIMENSIONS OF COOKTOP AND WORKTOP (mm)
NOTE: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2E+3+
ELECTRIC SUPPLY: 230 V ~ 50 Hz
Type of gas
used
Type of
burner
Injector
marking
Nominal
heating
capacity
kW
Nominal
consumption
Reduced heat
capacity kW
Gas pressure
(mbar)
FR BE
min. nom. max.
NATURAL GAS
(Methane) G20
large
medium
small
Y
115
H2
98
X
72
3.00
1.65
1.00
286 l/h
157 l/h
95 l/h
0.60
0.35
0.30
0.80
0.45
0.35
17 20 25
NATURAL GAS
(Groningue) G25
large
medium
small
Y
115
H2
98
X
72
3.00
1.65
1.00
332 l/h
183 l/h
111 l/h
0.60
0.35
0.30
0.60
0.35
0.30
20 25 30
LIQUID PETROLEUM
GAS
(Cylinder) G30
large
medium
small
87
65
50
3.00
1.65
1.00
218 g/h
120 g/h
73 g/h
0.60
0.35
0.30
0.60
0.35
0.30
20 28-30 35
LIQUID PETROLEUM
GAS
(Cylinder) G31
large
medium
small
87
65
50
3.00
1.65
1.00
214 g/h
118 g/h
71 g/h
0.60
0.35
0.30
0.60
0.35
0.30
25 37 45
Type of gas used
Model
configuration
Nominal heating capacity
kW
Total nominal
consumption
Air necessary ( m3) for the
combustion of 1 m3 of gas
G20 20 mbar 4 gas 7.30 695 l/h 9.52
G25 25 mbar 4 gas 7.30 809 l/h 8.187
G30 28-30 mbar 4 gas 7.30 531 g/h 30.94
G31 37 mbar 4 gas 7.30 521 g/h 23.80
IKEA of Sweden AB
SE - 343 81 Älmhult
/