JHS8 JHS-A006 is a portable air conditioner with cooling capacity of 1200 BTU/h. The device has three fan speed settings and can be set to cool, fan or dehumidify modes. It is controlled via a remote control or a control panel, has a digital display and a timer function. The device is equipped with an automatic water evaporation system, which means it doesn't require a drain hose. It uses R410A refrigerant and has a rotary compressor. For optimal cooling efficiency, the device should be used with the included exhaust pipe and window kit panel to vent the heat outside.

JHS8 JHS-A006 is a portable air conditioner with cooling capacity of 1200 BTU/h. The device has three fan speed settings and can be set to cool, fan or dehumidify modes. It is controlled via a remote control or a control panel, has a digital display and a timer function. The device is equipped with an automatic water evaporation system, which means it doesn't require a drain hose. It uses R410A refrigerant and has a rotary compressor. For optimal cooling efficiency, the device should be used with the included exhaust pipe and window kit panel to vent the heat outside.

Portable Air Conditioner
Model No: JHS-A006
Owners Manual
It is important that you read these instructions before using your new purchase and
we strongly recommend that you keep them in a safe place for future reference.
JHS8 TRADING COMPANY
Table of Contents
A ccessories
Wind ow K it Panel Installation
Water D rainage
………………………………………………6
U nit B od y A nd A ccessories
Safety Instructions …………………………………………………………… 1-2
Specifications ……………………………………………………………………3
…………………………………………………4
……………………………………………………………………5
Control Panel ……………………………………………………………………7
Remote Control ……………………………………………………………... 8-10
………………………………………………………………11
M aintenance …………………………………………………12
Troubleshooting ………………………………………………………………. 13
………………
1
IMPORTANT!
Ć
The unit is designed for indoor operation.
Ć
The
unit
is
not
designed to
cool
server
rooms,
sun
rooms, or
a room
generating constant high levels of heat.
Ć
Rating: This unit must be connected to a 2 2 0 -2 4 0 V ~ /50Hz grounded outlet.
Ć
The installation must be in accordance with regulations of the country where the unit is used.
If you are in any doubt about the electrical installation, have it checked and if necessary modified by a
qualified
electrician.
Ć
Never connect the unit to an electrical outlet using an extension cord.
If an outlet is not available, one should be installed by a licensed electrician.
Ć
The air conditioner is safe. However, as with any electrical appliance, use it with care.
Ć
Keep out of the reach of children.
Ć
Do not clean the unit by spraying it or immersing it in water.
Ć
Do not insert any object into the openings of the unit.
Ć
Disconnect the unit from the outlet before cleaning the unit or any of its components.
WARNING!
Ć
Never operate this appliance if it has a damaged cord or plug.
Ć
Do not lead the cord over sharp edges.
Ć
A damaged supply cord should be replaced by the manufacturer,
its service agent or a qualified person in order to avoid a hazard.
Ć
Any service other than regular cleaning or filter replacement should be performed by an authorized
service representative. Failure to do so could result in a loss of warranty.
Ć
See warranty page to read about warranty requirements, procedure, and instructions.
Safety Instructions
Ć
Dong let little children touch the machine.
2
IMPORTANT:
The first time that you use the unit, please ensure that it has been standing in an
upright position for at least 2 hours before it is switched on.
The unit is not to be used in temperatures under 5ĈºC or over 35ĈºC.
Safety
Instructions
Reminder:
Unit Contains R410A. Waste electrical products must not be disposed of with household
waste. This product should be taken to your local recycling center for safe treatment.
Close to a heat source
Inside unit exposed to the
weather outdoors
In a permanent very humid
environment
If the power cable wires
are frayed or cut
When small children may
be left unattended
Do Not Connect the unit
to extension cord.
Where the power cable
may be damaged
On a slope or uneven
surface
Where it may be damaged
by chemicals
Where there is a risk of
interference by foreign objects
This products is not made
for DIY repair
If there is a risk of liquid
falling on the unit
Do not use your air conditioner:
3
Specifi cations
JHS-A006ledoM
Cooling Capacity
Heating Capacity
Cooling
Power Consumption / Current 0142 W / 6.0 A
N/A
12000BTU/h
Moisture Removal in Cooling mod 37 L /day
Power Supply 2 2 0 -2 4 0 V ~ / 5 0 H z
A014RtnaregirfeR
yratoRrosserpmoC
sdeepS 3deepS naF
Cº32 -
-
Cº
CºCº
18
535
tatsomrehT
Ambient Temperature Range for
Operation
remiT ruo
h 42remiT
snoisnemiD
31kg/68.2lbsthgieW
The cooling capacity of the unit may be affected by the height of your ceiling, quality of your insulation, or
number of windows in your room. There is no current testing statute for portable air conditioning products
in the Indonesia, yet we have made every effort to design engineer a superior quality portable air
conditioning unit that effectively and efficiently cools select areas of the home or office.
(W*H*D)410x795x425 mm
Remote Control
Back Panel
E VA Air-outlet
Control Panel
Handle
E VA Filter
Heat-Output
CON Filter
Front Panel
Castor
4
Unit Body and Accessories
F ilter F rame
Activ e Carbon F ilter
( O ptional)
O uter Exhaust Connector Exhaust P ipe
Window K nit P anel
Water T ray
5
Unit Body and Accessories Accessories
I n order to achiev e optimum ef f iciency, exhaust pipe and window kit panel must be used
to output the heat air out of room as f ollowing:
O uter Exhaust Connector
Exhaust P ipe
Window K nit P anel P anel
I nstallation M ethods :
z Stretch the exhaust pipe to be at least 1 0 0 mm, and twist it clockwise into air-outlet.
z Stretch the other end of exhaust pipe to be at least 1 0 0 mm, and twist it clockwise into the outer
exhaust connector.
z Adjust the length of window kit panel and install it into window.
z Close the door and window , and f ix the window kit panel to window .
6
Unit Body and Accessories Window Kit Panel Installation
z Connect the outer exhaust connector to window kit panel.
z M ake sure the air in exhaust pipe can run smoothly.
T he exhaust pipe can be stretched to 5 0 0 mm~ 1 5 0 0mm, which is designed based on the machine test
data. U nauthoriz ed elongation or blocking of the exhaust pipe is prohibited, since it may cause the
damage of this machine .
P O WER: U nit- O N / O F F K ey. T he moment of P ower on, buz z er giv es a sound.
zndicator: nit-on, P ower I ndicator turns green; U nit- O f f , P ower I ndicator is of f .
z
seconds later, all loadings are of f , W . F . I ndicator turns red to show water- f ull.
z Signal- receiv ing I ndicator: receiv e the signals f rom remote control and then send them to main
base panel.
Signal- receiv ing I ndicator
P ower I ndicator
Water- f ull I ndicator
P O WER
7
Water- f ull I ndicator: U nit- on, P ower I ndicator turns green; U nit- O f f , P ower I ndicator is of f .
Unit Body and Accessories Control Panel
Power I
z Sudden power- of f happens during machine running, ma in base panel will hold the machine status
bef ore power- of f in memory, af ter machine re- start, it will recov er the unit status in memory.
z Remote control can be used when it put on its machine position or put it out of machine .
A. P O WER: press this key to T urn O n/ O f f machine, def ault v alue af ter U
AU
B. FAN SPEED:
z U nder CO O L mode, f an speeds are AU T O F ANĺL O W F AN ĺM I D ĺ
HI G H F AN .
z U nder F AN mode, f an speeds are L O W F ANėM I D D L E F AN ĺHI G H F AN
z U nder HU M mode , machine keeps L O W SP EED .
C. M O D E: press this key to get the f ollowing mode orderly: CO O L ШHU M
ШF AN
D . SL EEP M O D E: press this key to T urn- O N / O F F sleep f unction.
ϡU nder f an mode, no sleep f unction.
8
Unit Body and Accessories Remote Control
O F AN .
nit- O n is CO O L and
D L E F AN
U nder U nit - O f f status, set T
P ress T I M ER f or the f irst time, T imer Hour indictor f or U
adjust Hour –T imer; P ress T I M ER f or the second time, M inute\=- T imer indicator f or U
then press U
of any key f or 1 0 seconds to conf irm the T I M ER setting, then the T imer=\- O N indicator beside
8 8 : 8 8 turns on; press T I M ER f or the third time, T I M ER Hour indictor f or U nit\=- O f f f lashes, then
press U P / D O WN to adjust Hour- T imer; press T I M ER f or the f orth time, T I M ER M inute indictor
f or U nit- O f f f lashes, then press U P / D O WN to adjust M inute- T imer, at this moment T
indicator beside “ 8 8 : 8 8 turns on ; at last press T I M ER f or 2 seconds or no operation of any key f or
1 0 seconds to conf irm the T I M ER - setting.
z
U nder U nit- O n status, set T I M ER f or U nit- O f f as f ollowing:
P ress T I M ER f or the f irst time, T I M ER Hour indicator f or U nit- O f f f lashes, then press U P / D O WN
to adjust Hour- T imer; press T I M ER f or the second time, T I M ER M inute indicator f or U nit- O f f
f lashes, then press U P / D O W N to adjust M inute- T imer; at last press T I M ER f or 2 seconds or no
operation of any key f or 1 0 seconds to conf irm the T I M ER\- setting, and T imer- O F F indicator
beside “ 8 8 : 8 8 turns on .
ƽ
U nder U nit- O n status, set T I M ER f or U nit- O f f f irst then for U nit=- O n as f ollowing:
P ress T I M ER f or the f irst time, T I M ER Hour indicator f or U nit- O f f f lashes, then press U P / D O WN
to adjust Hour- T imer; press T I M ER f or the second time, T I M ER M inute indicator f or U nit- O f f
f lashes, then press U P / D O WN to adjust M inute- T imer, at this moment T imer- O F F indicator beside
8 8 : 8 8 turns on; press T I M ER f or the third time, T I M ER Hour indicator f or U nit- O n f lashes, then
press U P / D O WN to adjust Hour- T imer; press T I M ER f or the f orth time, T I M ER M inute indicator
f or U nit- O n f lashes, then press U P
/ D O WN to adjust M inute- T imer, and T imer- O N indicator
beside “ 8 8 : 8 8 turns on ; at last press T I M ER f or 2 seconds or no operation of any key f or 1 0
seconds to conf irm the T I M ER- setting .
9
P ress T I M ER f or the f irst time, T imer Hour indictor f or U nit- O n f lashes , then adjust U P / D O WN to
setting Hour –T imer; P ress T I M ER f or the second time, M inute- T imer indicator f or U nit- O n
f lashes, then adjust U P / D O W N to setting M inute- T imer; at last ,press T I M ER f or 2 second or no
operation of any key f or 1 0 seconds to conf irm the T I M ER - setting, then the T imer- O N indictor
beside “ 8 8 : 8 8 turns on .
z
T Κ
znder U nit- O f f status, set T I M ER f or U
E .
U
IERM
nit- O n as f ollowing :
I M ER f or Unit- O n f irstly, and then f or Unit- O f f as f ollowing:
nit- O n f lashes, then press UP / D O WN to
nit- O n f lashes,
P / D O WN to adjust M inute- Timer; at last , press T I M ER f or 2 second or no operation
imer- O F F
z
G .
SW ING ΚSwing-O N/O FF key
H.
CLEAR CLEAR Κ
P ress C L E AR for the first time , IO N function start to work and IO N indicator turn on:
press C L E AR for the second time, IO N function stop to work and IO N indicator turn off .
z
FIL TE R-C L E ANING INDIC ATO R: after 100 hours’ work of the mechine, filter- cleaning
indicator turns on to remind user to clean the filters.
1 0
18 C ~3 2 C ,each press makes 1 C up/down.
ʳʳ̓ʳʳʳʳʳʳʳʳʳʳʳʳʳʳʳʳʳʳʳʳʳʳʳʳʳʳʳʳʳʳʳʳʳʳʳʳʳʳʳʳʳʳʳʳ̓
U nder TIM E R mode, press U P /DO W N to adjust Hour-Timer from 0 to23 ( each press makes 1
U P /DO W N) , M inute-Timer from 0 to 55( each press makes 5 U P /DO W N)
F. U P / D O WN :
P ress this key to adjust the setting data of temperature, time and
timer as f ollowingΚ
zU
ʳ̓
nder COO L / HEAT mode, press UP / D O WN to adjust the temperature setting data f rom
ƽ Re-start the machine, water-full indicator is off .
1 1
zW hen internal water-tank is full, water-draining motor works abnormally. 10 minutes later ,U nit=-off
automatically and water-full indicator turns on .
zAfter empty the water-tank, press P O W E R to re=-start the machine.
W ater-drainage as following :
zP ower-off the power-supply and pull-out power cord .
zP ut water-receiving tray underneath the water-drainage port, then pull-out the water-stopper.
zDo not move the machine when water-drainage, otherwise cause water- leakage to wet the floor or
carpet.
zAfter internal water-tank is empty, re-put the water-stopper into its position.
Unit Body and Accessories Water Drainage
d. Install the filters to filter fixter.
e. M ake sure filters are clean and dry before installation.
f. B efore U nit-on, please make sure the filters are installed into the machine.
ƽU nplug the unit when not in use.
E mpty the internal water container and make sure no water left on evaporator before machine
storage.
ƽC lean the filters before machine storage.
zB efore water-drainage, please power-off the unit and pull-out the power-plug firstly.
zP lease use a soft damp cloth to clean the unit.
ƔDon’ t use chemical agents, such as benzene, alcohol, gasoline and soon; otherwise the machine
surface will be damaged, or even the machine itself.
zFilter-cleaning :
a. Filter-cleaning indicator turns on to show users the filters need to be cleaned.
b. Slide out filter frame from the unit and remove the filter fixer.
c. C lean common filter, active carbon filter ( optional) .
Unit Body and Accessories Maintenance
1 2
1 3
Troubleshooting
Never try to repair or dismantle the air condition yourself.
Incompetent repairs result in loss of warranty and can endanger the user and the property.
noituloSesuaCmelborP
The air
conditioner does
not function.*
No power supply. Make sure the
green light on the plug is lit.
Connect to a functioning outlet and switch on.
See below for Plug and Reset button application.
Is the power light ashing?
Is the water full LED lit? Empty the water container .
The air
conditioner does
not seem to
perform.
The unit is in direct sunlight. Close curtains/shades
Windows or doors open, many
people or a heat source in the room.
Close doors and windows. Unit is not made to
cool server rooms, sun rooms, or any rooms
generating a constant high levels of heat.
The filter is dirty. Clean the filter .
Air inlet or air outlet blocked. Power off the unit and unplug from outlet.
Remove blockage.
Room temperature lower than the
selected value.
Change temperature selection.
Set at the lowest possible setting: 16 C .
The unit is noisy. Unit stands uneven. Place on an even, solid surface (less vibrations).
The compressor
does not work.
The overheat protection may be
activated.
Wait 30 minutes until the temperature has
decreased, then turn on the unit again.
The remote
control does not
function.
Distance too great. Make sure the remote control is correctly aimed
at the control panel.
Remote control signal not detected
by the control panel.
The batteries are drained. Check batteries on the remote control.
Note: When abnormal situations occur, turn off machine and pull out plug, then contact
with professional electrician for help
* Make sure unit is plugged directly into a dedicated electrical source/outlet.
Do not use any extension cords. See electrical specications listed on
page 3 and make sure the electrical source can accommodate the unit’s
energy consumption.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15

JHS8 JHS-A006 Owner's manual

Category
Mobile air conditioners
Type
Owner's manual

JHS8 JHS-A006 is a portable air conditioner with cooling capacity of 1200 BTU/h. The device has three fan speed settings and can be set to cool, fan or dehumidify modes. It is controlled via a remote control or a control panel, has a digital display and a timer function. The device is equipped with an automatic water evaporation system, which means it doesn't require a drain hose. It uses R410A refrigerant and has a rotary compressor. For optimal cooling efficiency, the device should be used with the included exhaust pipe and window kit panel to vent the heat outside.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI