  • Hello! I am an AI chatbot trained to assist you with the Airwell DLV 007 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
INSTALLATION MANUAL
SAFETY PRECAUTIONS
● Readthefollowing"SAFETYPRECAUTIONS"carefullybeforeinstallation.
● Carryouttestrunningtoconrmthatnoabnormalityoccursaftertheinstallation.Then,explaintousertheoperation,careandmaintenanceasstatedin
instructions.Pleaseremindthecustomertokeeptheoperatinginstructionsforfuturereference.
Thisindicationshowsthepossibilityofcausingdeathorseriousinjury.
WARNING
Thisindicationshowsthepossibilityofcausingharmordamagetheequipment.
CAUTION
WARNING
1)Usequaliedinstallerandfollowcarefullythisinstructions.Otherwiseitwillcauseelectricalshock,waterleakage,orestheticproblem.
2)Installatastrongandrmlocationwhichisabletowithstandtheset'sweight.Ifthestrengthisnotenoughorinstallationisnotproperlydone,theset
willdropandcauseinjury.
3)Forelectricalwork,followthelocalnationalwiringstandard,regulationandthisinstallationinstruction.Anindependentcircuitandsingleoutletmust
beused.Ifelectricalcircuitcapacityisnotenoughordefectfoundinelectricalwork,itwillcauseelectricalshockorre.
4)Usethespeciedcableandconnecttightlyforindoorconnection.Connecttightlyandclampthecablesothatnoexternalforcewillbeactedonthe
terminal.Ifconnectionorxingisnotperfect,itwillcauseheat-uporreattheconnection.
5)Wireroutingmustbeproperlyarrangedsothatcontrolboardcoverisxedproperly.Ifcontrolboardcoverisnotxedperfectly,itwillcauseheat-up
atconnectionpointofterminal,reorelectricalshock.
6)Whencarryingoutpipingconnection,takecarenottoletairsubstancesotherthanthespeciedrefrigerantgointorefrigerationcycle.Otherwise,it
willcauselowercapacity,abnormalhighpressureintherefrigerationcycle,explosionandinjury.
7)Donotdamageoruseunspeciedpowersupplycord.Otherwise,itwillcausereorelectricalshock.
8)Thisequipmentmustbeearthed.Itmaycauseelectricalshockifthegroundingisnotperfect.
9)Donotinstalltheunitatplacewhereleakageofammablegasmayoccur.Incasegasleaksandaccumulatesatsurroundingoftheunit,itmay
causere.
10)Pleasediconnectthepowersupplywheninstallormaintenanceorsevicethissystem.
CAUTION
1)Selectionoftheinstallationlocation.
Selectainstallationlocationwhichisrigidandstrongenoughtosupportorholdtheunit,andselectalocationforeasymaintenance.
2)Donotreleaserefrigerant.
Donotreleaserefrigerantduringpipingworkforinstallation,reinstallationandduringrepairingarefrigerationparts.Takecareoftheliquidrefrigerant.
itmaycausefrostbite.
3)Itmayneedtwopeopletocarryouttheinstallationwork.
4)Donotinstallthisapplianceinalaundryroomorotherlocationwherewatermaydripfromtheceiling,etc.
5)Carryoutdrainagepipesasmentionedininstallationinstructions.Ifdrainageisnotperfect,watermayentertheroomanddamagethefurniture.
PartNO.IM.DLV1_A.1GB
MODELS
Ducttypeairconditioner
DLV007DLV009
DLV012DLV015
DLV018DLV021
DLV024
Unit:mm
Requiredtoolsforinstallationworks
NO. Tool NO. Tool NO. Tool
1 Screwdriver 5 Pipecutter
9
Torquewrench
18Nm(1.8kgf.m)
45Nm(4.5kgf.m)
65Nm(6.5kgf.m)
75Nm(7.5kgf.m)
2
Electricdrill,holecore
drill(60mm)
6 Reamer
3 Hexagonalwrench 7 Knife
4 Spanner 8 Measuringtape
Attachedaccessories
No. Accessoriespart Qty. No. Accessoriespart Qty. No. Accessoriespart Qty.
1
Centralcontrol
display(optional)
1 3
Draintube+clips
1 5
Unitoperationmanual
Installationmanual
2
2
Tie-Waps
6 4
Screwswasher
dowels
5 6
Gastubinginsulation
1
1
SELECT THE BEST LOCATION
Whileselectingaplacefortheindoorunit
Allowmax.airowtothedesirespace.
Allowmaxreturnairow.
Ensureadequatedrainageofcondensedwater.
T
hedistancebetweenair-conditionerandobstaclesshouldmeetstherequirmentsinbelowg.
Leaveaminimum250mmfreespaceinfrontofthelter.
Allowafreeserviceaccesstoelectricalbox.
Alloweasyaccesstothebaseoftheindoorunitwhileprovidingenoughspacefromtheceiling.
Theinstallationheightshouldover2.3m.
2
UNIT INSTALLATION
1.HOLESDRILLINGLOCATIONONTHECEILINGFORINDOORUNIT
Model A B
DLV007-DLV015 790 565
DLV018-DLV024 1090 565
2.DRAINAGEINSTALLATION
General
Foranefcientfunctioningofthedrainagesystem,pleasetakecareofthefollowing:
Alwaysbalancetheunitwith2downwardtothedrainagesideoftheunit.
Use19mmtubedrainage.
Itisrecommendedtoprepareadrainagepointbyprofessionalplumberclosetotheunit.
Forproperdrainage,thepassagemustbeplannedwith1downslope.
Preventanyupwardsorreverseowinanypart.
Forpreventingofunpleasantsmellsintheroom,installasiphonintheinstallation.Installthedrainingtubewith6mmthicknesst hermalinsulationsleeve.
Horizontaldrainage
Theunitincludesadrainpump,whichcanelevatecondensatewaterupto120cmfromtheunitlowestlevel.Thedrainagetubeisconnectedtotheupper
drainagenozzle.
Thelowerdrainagenozzleroleistoemptythedrainpanbeforeservicingtheunit.
Installonthedraintubewith5-10mmthicknessthermalinsulationsleevetopreventdrippings.
Drainagetest
ForVRFsystempleasedodrainagetestafternishingallinstallations,wiringandpipingincluded,anddoingITEST(Installationtest)sucessfully:
(1)Poweronthesystem,andrunscoolingmode.
(2)Checkwhetherthepumpsoundisnormal.
(3)Slowlyinjectabout1,000ccofwaterintothedrainpan.Checkthedrainagethroughthetransparentdrainporttoseeifanydrainleakagehappens.
(4)Whenthecheckisnished,donotforgettocutoffthepowersupply.
3.UNITDIMENSIONS
Model A B C
DLV007-DLV015 750 696 790
DLV018-DLV024 1050 996 1090
4.ACCESSTOTHEUNIT
ΦLiquidPipe ΦGasPipe
DLV007 1/4" 1/2"
DLV009 1/4" 1/2"
DLV012 1/4" 1/2"
DLV015 1/4" 1/2"
DLV018 1/4" 1/2"
DLV021 3/8" 5/8"
DLV024 3/8" 5/8"
5.UNITINSTALLATION
Insert4M10or3/8threadsrodsintotheceiling.A.
Introducetherodsthroughtheslotsofunitsuspensionbrackets.B.
Positiontheshockabsorbers,add washersandscrewthe nuts until theC.
unitisrmlysupported.
In case of a gap between the unit and the ceiling, put a rubber or aD.
neoprenesheet.
565
Unit:mm
6.AIRFILTERLOCATION
Theairlterislocatedintherearsideoftheunit(defaultfromfactory)butcanbeeasilyrelocatedinthebottomoftheunitifitisrequired.
7.AIRFILTERCLEANING
Forcleaningthelterremoveitbypushinguptowardthebackoftheunitandpullitoutasdescribedbelow.
8.AIRFILTERRELOCATION
Removeairlterfromtheunit.1.
Removepanel4.2.
Removeltertrails2-3.3.
Insertltertrails2-3ontheoppositesideoftheunit.5.Closepanel4inthe4.
rearsideoftheunit.
Insertthelterintothetrails.5.
3
DISPLAY CONTROL UNIT
1.LOCATIONCRITERIA
ItisrecommendedtoinstalltheDisplayControlUnitclosetoaceilinginacentralandneutral zoneattypical conditions. Inaddition,the aesthetic aspect
shouldbeconsidered.
TheDisplayControlUnitisconnectedtothemaincontrolboardontheairconditioner(theindoorunit)byacommunicationcable.Cableisconnectedtothe
DisplayControlUnitbyaquick-connector.(8pinplug)
2.INSTALLATIONOFDISPLAYCONTROLUNITONWALL
Drilla12mmdiameterholeonthewall,forroutingthecommunicationcable.
Opentheunitcover,drill3holesinthewalltomatchtheholesintheDisplayControlUnit,installtheinsertsandfastentheunittothewallwith3screws.
TheDisplayControlUnitisprovidedofaspecialcommunicationcable,7meterslong,terminatedbyaplug,connectedinthehousingitselftoadistribution
box,whichenablesthecontroloftheairconditionerfromseveraldifferentrooms,eachonefromitsownDisplayControlUnit.
Connectthequickconnectortotheappropriatesocketonthemaincontrolboardintheindoorunitelectricalbox.
3.CONSIDERATIONSINLOCATINGTHEREMOTECONTROLUNIT
a)LocatetheRemoteControlUnitinsuchawaythatwhenmountedonitssupportonthewall,itwillbeinlinesightwiththeDisplayControl
Unit(atlessthan8m).
b)ItisrecommendedtoestablishthenallocationoftheRemoteControlUnitonlyaftertherstoperation,assuringpropertransmissionand
receptionbetweentheRemoteControlUnitandtheDisplayControlUnit.
1.MainControlBoardonIndoorUnit.
2.DistributionBoard.
3.CommunicationCable.
COLORCHART
Conn.Point WireColor Conn.Point WireColor
1 Blue 5 Purple
2 Green 6 Yellow
3 Black 7 Orange
4 Brown 8 Red
4
ELECTRICAL WIRING CONNECTION
1.POWERSUPPLYWIRING
Unscrewandremovetheelectricalbox.
Connectthepowersupplywiringstothepowersupplyterminalblock.
Whendoingthis,pressthepowersupplywiringunderthewireclip.
UNOCCUPIED DRY CONTACT
COMMUNICATIONWIRE
PROWER SOURCE WIRE
WINDOWS DRY CONTACT
ELB:ElectricityLeakageBreaker.
AH:Assistantheater.
PowerSupply
MainBusR/CWiring
2.MAINBUSANDR/CCOMMUNICATIONWIRING
Unscrewandremovetheelectricalbox.
ConnecttheR/CwiringstoR1,R2terminalblockandthemainbuswiringstoF1,F2terminalblock.
Pressthewiringsunderthewirecliptightly.
3.TIGHTENINGTORQUEFORTHETERMINALSCREWS
Usethecorrectscrewdriverfortighteningtheterminalscrews.
Ifthebladeofscrewdriveristoosmall, theheadofthescrew mightbedamaged,Andthe screwwillnot beproperlytightened.Iftheterminalscrews are
tightenedtoohard,screwsmightbedamaged.
Refertothetablebelowforthetighteningtorqueoftheterminalscrews.
Terminal Size Tighteningtorque
Terminalblock(total9pins) M4 1.2~1.5N.m
4.ELECTRICALCHARACTERISTICS
Unit Powersupply Fanmotor
MCA: Min.CircuitAmps(A)
MFA: Max.FuseAmps(A)
KW: FanMotorRatedOutput(KW)
LA: FullLoadAmps(A)
Model Hz Volts MCA MFA KW FLA
DLV007
50 220~240
0.64 16 0.12 0.38
DLV009 0.64 16 0.12 0.38
DLV012 0.64 16 0.12 0.38
DLV015 0.64 16 0.12 0.38
DLV018 0.73 16 0.14 0.45
DLV021 0.73 16 0.14 0.45
DLV024 0.73 16 0.14 0.45
Alleldsuppliedpartsandmaterialsandelectricsworksmustconformtolocalcodes.
Usecopperwireonly.
Allwiringmustbeperformedbyanauthorizedelectrician.
Everyindoorunitmusthaveasubcirclebreakerandthewholesystemmusthaveamaincirclebreaker.
Besuretogroundtheairconditioner.
Theapplianceshallbeinstalledinaccordancewithnationalwiringregulations,andshallbeprovidedtoensureall-poledisconnectionfromthesupplymains,
anddistancebetweenthepolesshallbemorethan3mm.
5.SPECIFICATIONSFORFIELDSUPPLIEDELBANDWIRE
Model
Powersupplywiring
RemotecontrollerwiringTransmission
wiring
FieldELB WireandSize wires Size
DLV007
16A
Mustcomply
withmaximum
currentandlocal
codes(
0.75mm
2
)
Twisted-pairWire
1.0mm
2
DLV009
DLV012
DLV015
DLV018
DLV021
DLV024
6.HEIGHTCOMPENSATIONSETTING
TheCompensationsettingaccordingtoinstallationheightcanbedonebyusingthedipswitch11and12oncontrollerPCB.
InstallationHeight HeightCode DS11 DS12
2.3-2.7(m) H0 OFF OFF
2.7-3.1(m) H1 OFF ON
3.1-3.5(m) H2 ON OFF
3.5(m) H3 ON ON
Note:Pleasedisconnectthepowersupplywhenchangethissetting.
Ifyoufeeltoonoisy,pleasesetDS11andDS12tolowerheightcodelevel.
CHECK ITEMS
BEFOREPOWERON
Isthereanygasleakageatarenutconnections?
Hastheheatinsulationbeencarriedoutatarenutconnection?
Istheconnectingcablebeingxedtoterminalboardrmly?Istheconnectingcablebeingclampedrmly?
IsthedrainageOK?(Referto"Checkthedrainage"section)
Istheearthwireconnectionproperlydone?
Istheindoorunitproperlyhookedtotheinstallationplate?Isthepowersupplyvoltagecompliedwithratedvalue?
AFTER POWER ON
Isthereanyabnormalsound?
Isthecoolingoperationnormal?
Isthethermostatoperationnormal?
Istheremotecontrol'sLCDoperationnormal?
/