Airwell DLV 007 Installation guide

Category
Split-system air conditioners
Type
Installation guide

Airwell DLV 007 is a duct type air conditioner renowned for its efficiency and versatility. Its key capabilities include:

  • Precise Temperature Control: DLV 007 offers precise temperature regulation, ensuring a comfortable indoor environment all year round.

  • Energy Efficiency: With its advanced technology, DLV 007 operates efficiently, consuming less energy while maintaining optimal cooling or heating performance.

  • Quiet Operation: Enjoy a peaceful indoor atmosphere as DLV 007 functions with minimal noise, creating a serene environment for relaxation or work.

  • Flexible Airflow: DLV 007 allows for adjustable airflow direction, enabling you to customize the airflow distribution according to your room layout and preferences.

Airwell DLV 007 is a duct type air conditioner renowned for its efficiency and versatility. Its key capabilities include:

  • Precise Temperature Control: DLV 007 offers precise temperature regulation, ensuring a comfortable indoor environment all year round.

  • Energy Efficiency: With its advanced technology, DLV 007 operates efficiently, consuming less energy while maintaining optimal cooling or heating performance.

  • Quiet Operation: Enjoy a peaceful indoor atmosphere as DLV 007 functions with minimal noise, creating a serene environment for relaxation or work.

  • Flexible Airflow: DLV 007 allows for adjustable airflow direction, enabling you to customize the airflow distribution according to your room layout and preferences.

INSTALLATION MANUAL
SAFETY PRECAUTIONS
● Readthefollowing"SAFETYPRECAUTIONS"carefullybeforeinstallation.
● Carryouttestrunningtoconrmthatnoabnormalityoccursaftertheinstallation.Then,explaintousertheoperation,careandmaintenanceasstatedin
instructions.Pleaseremindthecustomertokeeptheoperatinginstructionsforfuturereference.
Thisindicationshowsthepossibilityofcausingdeathorseriousinjury.
WARNING
Thisindicationshowsthepossibilityofcausingharmordamagetheequipment.
CAUTION
WARNING
1)Usequaliedinstallerandfollowcarefullythisinstructions.Otherwiseitwillcauseelectricalshock,waterleakage,orestheticproblem.
2)Installatastrongandrmlocationwhichisabletowithstandtheset'sweight.Ifthestrengthisnotenoughorinstallationisnotproperlydone,theset
willdropandcauseinjury.
3)Forelectricalwork,followthelocalnationalwiringstandard,regulationandthisinstallationinstruction.Anindependentcircuitandsingleoutletmust
beused.Ifelectricalcircuitcapacityisnotenoughordefectfoundinelectricalwork,itwillcauseelectricalshockorre.
4)Usethespeciedcableandconnecttightlyforindoorconnection.Connecttightlyandclampthecablesothatnoexternalforcewillbeactedonthe
terminal.Ifconnectionorxingisnotperfect,itwillcauseheat-uporreattheconnection.
5)Wireroutingmustbeproperlyarrangedsothatcontrolboardcoverisxedproperly.Ifcontrolboardcoverisnotxedperfectly,itwillcauseheat-up
atconnectionpointofterminal,reorelectricalshock.
6)Whencarryingoutpipingconnection,takecarenottoletairsubstancesotherthanthespeciedrefrigerantgointorefrigerationcycle.Otherwise,it
willcauselowercapacity,abnormalhighpressureintherefrigerationcycle,explosionandinjury.
7)Donotdamageoruseunspeciedpowersupplycord.Otherwise,itwillcausereorelectricalshock.
8)Thisequipmentmustbeearthed.Itmaycauseelectricalshockifthegroundingisnotperfect.
9)Donotinstalltheunitatplacewhereleakageofammablegasmayoccur.Incasegasleaksandaccumulatesatsurroundingoftheunit,itmay
causere.
10)Pleasediconnectthepowersupplywheninstallormaintenanceorsevicethissystem.
CAUTION
1)Selectionoftheinstallationlocation.
Selectainstallationlocationwhichisrigidandstrongenoughtosupportorholdtheunit,andselectalocationforeasymaintenance.
2)Donotreleaserefrigerant.
Donotreleaserefrigerantduringpipingworkforinstallation,reinstallationandduringrepairingarefrigerationparts.Takecareoftheliquidrefrigerant.
itmaycausefrostbite.
3)Itmayneedtwopeopletocarryouttheinstallationwork.
4)Donotinstallthisapplianceinalaundryroomorotherlocationwherewatermaydripfromtheceiling,etc.
5)Carryoutdrainagepipesasmentionedininstallationinstructions.Ifdrainageisnotperfect,watermayentertheroomanddamagethefurniture.
PartNO.IM.DLV1_A.1GB
MODELS
Ducttypeairconditioner
DLV007DLV009
DLV012DLV015
DLV018DLV021
DLV024
Unit:mm
Requiredtoolsforinstallationworks
NO. Tool NO. Tool NO. Tool
1 Screwdriver 5 Pipecutter
9
Torquewrench
18Nm(1.8kgf.m)
45Nm(4.5kgf.m)
65Nm(6.5kgf.m)
75Nm(7.5kgf.m)
2
Electricdrill,holecore
drill(60mm)
6 Reamer
3 Hexagonalwrench 7 Knife
4 Spanner 8 Measuringtape
Attachedaccessories
No. Accessoriespart Qty. No. Accessoriespart Qty. No. Accessoriespart Qty.
1
Centralcontrol
display(optional)
1 3
Draintube+clips
1 5
Unitoperationmanual
Installationmanual
2
2
Tie-Waps
6 4
Screwswasher
dowels
5 6
Gastubinginsulation
1
1
SELECT THE BEST LOCATION
Whileselectingaplacefortheindoorunit
Allowmax.airowtothedesirespace.
Allowmaxreturnairow.
Ensureadequatedrainageofcondensedwater.
T
hedistancebetweenair-conditionerandobstaclesshouldmeetstherequirmentsinbelowg.
Leaveaminimum250mmfreespaceinfrontofthelter.
Allowafreeserviceaccesstoelectricalbox.
Alloweasyaccesstothebaseoftheindoorunitwhileprovidingenoughspacefromtheceiling.
Theinstallationheightshouldover2.3m.
2
UNIT INSTALLATION
1.HOLESDRILLINGLOCATIONONTHECEILINGFORINDOORUNIT
Model A B
DLV007-DLV015 790 565
DLV018-DLV024 1090 565
2.DRAINAGEINSTALLATION
General
Foranefcientfunctioningofthedrainagesystem,pleasetakecareofthefollowing:
Alwaysbalancetheunitwith2downwardtothedrainagesideoftheunit.
Use19mmtubedrainage.
Itisrecommendedtoprepareadrainagepointbyprofessionalplumberclosetotheunit.
Forproperdrainage,thepassagemustbeplannedwith1downslope.
Preventanyupwardsorreverseowinanypart.
Forpreventingofunpleasantsmellsintheroom,installasiphonintheinstallation.Installthedrainingtubewith6mmthicknesst hermalinsulationsleeve.
Horizontaldrainage
Theunitincludesadrainpump,whichcanelevatecondensatewaterupto120cmfromtheunitlowestlevel.Thedrainagetubeisconnectedtotheupper
drainagenozzle.
Thelowerdrainagenozzleroleistoemptythedrainpanbeforeservicingtheunit.
Installonthedraintubewith5-10mmthicknessthermalinsulationsleevetopreventdrippings.
Drainagetest
ForVRFsystempleasedodrainagetestafternishingallinstallations,wiringandpipingincluded,anddoingITEST(Installationtest)sucessfully:
(1)Poweronthesystem,andrunscoolingmode.
(2)Checkwhetherthepumpsoundisnormal.
(3)Slowlyinjectabout1,000ccofwaterintothedrainpan.Checkthedrainagethroughthetransparentdrainporttoseeifanydrainleakagehappens.
(4)Whenthecheckisnished,donotforgettocutoffthepowersupply.
3.UNITDIMENSIONS
Model A B C
DLV007-DLV015 750 696 790
DLV018-DLV024 1050 996 1090
4.ACCESSTOTHEUNIT
ΦLiquidPipe ΦGasPipe
DLV007 1/4" 1/2"
DLV009 1/4" 1/2"
DLV012 1/4" 1/2"
DLV015 1/4" 1/2"
DLV018 1/4" 1/2"
DLV021 3/8" 5/8"
DLV024 3/8" 5/8"
5.UNITINSTALLATION
Insert4M10or3/8threadsrodsintotheceiling.A.
Introducetherodsthroughtheslotsofunitsuspensionbrackets.B.
Positiontheshockabsorbers,add washersandscrewthe nuts until theC.
unitisrmlysupported.
In case of a gap between the unit and the ceiling, put a rubber or aD.
neoprenesheet.
565
Unit:mm
6.AIRFILTERLOCATION
Theairlterislocatedintherearsideoftheunit(defaultfromfactory)butcanbeeasilyrelocatedinthebottomoftheunitifitisrequired.
7.AIRFILTERCLEANING
Forcleaningthelterremoveitbypushinguptowardthebackoftheunitandpullitoutasdescribedbelow.
8.AIRFILTERRELOCATION
Removeairlterfromtheunit.1.
Removepanel4.2.
Removeltertrails2-3.3.
Insertltertrails2-3ontheoppositesideoftheunit.5.Closepanel4inthe4.
rearsideoftheunit.
Insertthelterintothetrails.5.
3
DISPLAY CONTROL UNIT
1.LOCATIONCRITERIA
ItisrecommendedtoinstalltheDisplayControlUnitclosetoaceilinginacentralandneutral zoneattypical conditions. Inaddition,the aesthetic aspect
shouldbeconsidered.
TheDisplayControlUnitisconnectedtothemaincontrolboardontheairconditioner(theindoorunit)byacommunicationcable.Cableisconnectedtothe
DisplayControlUnitbyaquick-connector.(8pinplug)
2.INSTALLATIONOFDISPLAYCONTROLUNITONWALL
Drilla12mmdiameterholeonthewall,forroutingthecommunicationcable.
Opentheunitcover,drill3holesinthewalltomatchtheholesintheDisplayControlUnit,installtheinsertsandfastentheunittothewallwith3screws.
TheDisplayControlUnitisprovidedofaspecialcommunicationcable,7meterslong,terminatedbyaplug,connectedinthehousingitselftoadistribution
box,whichenablesthecontroloftheairconditionerfromseveraldifferentrooms,eachonefromitsownDisplayControlUnit.
Connectthequickconnectortotheappropriatesocketonthemaincontrolboardintheindoorunitelectricalbox.
3.CONSIDERATIONSINLOCATINGTHEREMOTECONTROLUNIT
a)LocatetheRemoteControlUnitinsuchawaythatwhenmountedonitssupportonthewall,itwillbeinlinesightwiththeDisplayControl
Unit(atlessthan8m).
b)ItisrecommendedtoestablishthenallocationoftheRemoteControlUnitonlyaftertherstoperation,assuringpropertransmissionand
receptionbetweentheRemoteControlUnitandtheDisplayControlUnit.
1.MainControlBoardonIndoorUnit.
2.DistributionBoard.
3.CommunicationCable.
COLORCHART
Conn.Point WireColor Conn.Point WireColor
1 Blue 5 Purple
2 Green 6 Yellow
3 Black 7 Orange
4 Brown 8 Red
4
ELECTRICAL WIRING CONNECTION
1.POWERSUPPLYWIRING
Unscrewandremovetheelectricalbox.
Connectthepowersupplywiringstothepowersupplyterminalblock.
Whendoingthis,pressthepowersupplywiringunderthewireclip.
UNOCCUPIED DRY CONTACT
COMMUNICATIONWIRE
PROWER SOURCE WIRE
WINDOWS DRY CONTACT
ELB:ElectricityLeakageBreaker.
AH:Assistantheater.
PowerSupply
MainBusR/CWiring
2.MAINBUSANDR/CCOMMUNICATIONWIRING
Unscrewandremovetheelectricalbox.
ConnecttheR/CwiringstoR1,R2terminalblockandthemainbuswiringstoF1,F2terminalblock.
Pressthewiringsunderthewirecliptightly.
3.TIGHTENINGTORQUEFORTHETERMINALSCREWS
Usethecorrectscrewdriverfortighteningtheterminalscrews.
Ifthebladeofscrewdriveristoosmall, theheadofthescrew mightbedamaged,Andthe screwwillnot beproperlytightened.Iftheterminalscrews are
tightenedtoohard,screwsmightbedamaged.
Refertothetablebelowforthetighteningtorqueoftheterminalscrews.
Terminal Size Tighteningtorque
Terminalblock(total9pins) M4 1.2~1.5N.m
4.ELECTRICALCHARACTERISTICS
Unit Powersupply Fanmotor
MCA: Min.CircuitAmps(A)
MFA: Max.FuseAmps(A)
KW: FanMotorRatedOutput(KW)
LA: FullLoadAmps(A)
Model Hz Volts MCA MFA KW FLA
DLV007
50 220~240
0.64 16 0.12 0.38
DLV009 0.64 16 0.12 0.38
DLV012 0.64 16 0.12 0.38
DLV015 0.64 16 0.12 0.38
DLV018 0.73 16 0.14 0.45
DLV021 0.73 16 0.14 0.45
DLV024 0.73 16 0.14 0.45
Alleldsuppliedpartsandmaterialsandelectricsworksmustconformtolocalcodes.
Usecopperwireonly.
Allwiringmustbeperformedbyanauthorizedelectrician.
Everyindoorunitmusthaveasubcirclebreakerandthewholesystemmusthaveamaincirclebreaker.
Besuretogroundtheairconditioner.
Theapplianceshallbeinstalledinaccordancewithnationalwiringregulations,andshallbeprovidedtoensureall-poledisconnectionfromthesupplymains,
anddistancebetweenthepolesshallbemorethan3mm.
5.SPECIFICATIONSFORFIELDSUPPLIEDELBANDWIRE
Model
Powersupplywiring
RemotecontrollerwiringTransmission
wiring
FieldELB WireandSize wires Size
DLV007
16A
Mustcomply
withmaximum
currentandlocal
codes(
0.75mm
2
)
Twisted-pairWire
1.0mm
2
DLV009
DLV012
DLV015
DLV018
DLV021
DLV024
6.HEIGHTCOMPENSATIONSETTING
TheCompensationsettingaccordingtoinstallationheightcanbedonebyusingthedipswitch11and12oncontrollerPCB.
InstallationHeight HeightCode DS11 DS12
2.3-2.7(m) H0 OFF OFF
2.7-3.1(m) H1 OFF ON
3.1-3.5(m) H2 ON OFF
3.5(m) H3 ON ON
Note:Pleasedisconnectthepowersupplywhenchangethissetting.
Ifyoufeeltoonoisy,pleasesetDS11andDS12tolowerheightcodelevel.
CHECK ITEMS
BEFOREPOWERON
Isthereanygasleakageatarenutconnections?
Hastheheatinsulationbeencarriedoutatarenutconnection?
Istheconnectingcablebeingxedtoterminalboardrmly?Istheconnectingcablebeingclampedrmly?
IsthedrainageOK?(Referto"Checkthedrainage"section)
Istheearthwireconnectionproperlydone?
Istheindoorunitproperlyhookedtotheinstallationplate?Isthepowersupplyvoltagecompliedwithratedvalue?
AFTER POWER ON
Isthereanyabnormalsound?
Isthecoolingoperationnormal?
Isthethermostatoperationnormal?
Istheremotecontrol'sLCDoperationnormal?
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Airwell DLV 007 Installation guide

Category
Split-system air conditioners
Type
Installation guide

Airwell DLV 007 is a duct type air conditioner renowned for its efficiency and versatility. Its key capabilities include:

  • Precise Temperature Control: DLV 007 offers precise temperature regulation, ensuring a comfortable indoor environment all year round.

  • Energy Efficiency: With its advanced technology, DLV 007 operates efficiently, consuming less energy while maintaining optimal cooling or heating performance.

  • Quiet Operation: Enjoy a peaceful indoor atmosphere as DLV 007 functions with minimal noise, creating a serene environment for relaxation or work.

  • Flexible Airflow: DLV 007 allows for adjustable airflow direction, enabling you to customize the airflow distribution according to your room layout and preferences.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI