3M Ketac™ Cem Radiopaque Permanent Glass Ionomer Luting Cement User guide

Type
User guide
Ketac-Cem
®
Radiopaque
Step-by-step
ESPE Dental-Medizin
82229 Seefeld
Germany
Remove temporary
crown
Clean abutment with
pumice and water
Dry, moderately and
do not desiccate
Clean the crown
with air
Ratio: 1 spoon powder
+ 2 drops liquid
Take powder with the
spoon. Scrap off excess
Put the drops on the
mixing pad
Mix powder and
liquid
Brush a thin coat of
cement
Place the crown
without pressure
MIN : SEC
03:30
Setting: 3:30 min Remove excess
MIN : SEC
03:30
Mixing and working
time:
3:30
min
Result
Consult instructions
prior to use.
73 77 71/01 (10.96)