Cabletron Systems SmartCell ZX-250 Reference guide

Type
Reference guide

This manual is also suitable for

SmartCell 6A000/ZX-250
Reference Manual
35 Industrial Way
Rochester, NH 03866-5005
USA
(603) 332-9400
Part Number 04-0044-03 Rev. A
Order Number 9032537
ii SmartCell 6A000/ZX-250 Reference Manual
NOTICE
Cabletron reserves the right to make changes in specifications and other information contained in this document
without prior notice. The reader should in all cases consult Cabletron to determine whether any such changes have
been made. The hardware, firmware, or software described in this manual is subject to change without notice.
IN NO EVENT SHALL CABLETRON BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL, OR
CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING, BUT NOT LIMITED TO, LOST PROFITS)
ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT, EVEN IF
CABLETRON HAS BEEN ADVISED OF, KNOWN, OR SHOULD HAVE KNOWN THE POSSIBILITY OF
SUCH DAMAGES.
Copyright 1998 by Cabletron, Inc., P.O. Box 5005, Rochester, NH03866-5005
All Rights Reserved
Printed in the United States of America
SmartCell 6A000/ZX-250 Reference Manual
04-0044-03 Rev. A
Order # 9032537
SmartCell, SPECTRUM, LANVIEW, MicroMMAC, and BRIM are registered trademarks and Element Manager,
EPIM, EPIMA, EPIM-F1, EPIM-F2, EPIM-F3, EPIM-T, EPIM-X, FOT-F, FOT-F3, HubSTACK, SEH, SEHI, and
TMS-3 are trademarks of Cabletron, Inc. All other product names mentioned in this manual may be trademarks or
registered trademarks of their respective companies.
SmartCell, SPECTRUM, LANVIEW, MicroMMAC, and BRIM are registered trademarks and Element Manager,
EPIM, EPIMA, EPIM-F1, EPIM-F2, EPIM-F3, EPIM-T, EPIM-X, FOT-F, FOT-F3, HubSTACK, SEH, SEHI, and
TMS-3 are trademarks of CSI ZeitNet, Inc. All other product names mentioned in this manual may be trademarks or
registered trademarks of their respective companies.
SmartCell 6A000/ZX-250 Reference Manual iii
REVISION HISTORY
Document Name:SmartCell 6A000/ZX-250 Reference Manual
Document Order Number: Order # 9032527
Document Part Number: 04-0044-03 Rev. A
Author: Robert dePeyster
Editor: Carre Gibson
Date
Revision Description
October 1997 04-0044-02 Rev. A Initial release
March 1998 04-0044-03 Rev. A First Revision
iv SmartCell 6A000/ZX-250 Reference Manual
SmartCell 6A000/ZX-250 Reference Manual v
TABLE OF CONTENTS
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Audience and Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Content . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Sections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Help Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Other Reference Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Switch Attribute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
List of Commands and Possible Switch Attributes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
2 Console Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
AlarmDisplay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Alias . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
ATMRoute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
BUSClient . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11
BUSELAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13
BUSLECStat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-16
BUSStat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-18
CACEqBwAllocScheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-20
CacInfo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-22
CACPortBw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-24
CACServiceClassBw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-26
Client . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-28
ClientARP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-32
ClientStat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-34
ClientVC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-38
Community . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-40
Config . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-42
ConsoleTimeout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-44
CoreDump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-45
ELAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-47
EventDisplay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-51
Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-52
Exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-54
Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-55
vi SmartCell 6A000/ZX-250 Reference Manual
Table of Contents
History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-57
IlmiTimers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-58
IPAddress . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-60
IPATMARP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-61
IPATMClient . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-62
IPATMPVC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-65
IPATMStat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-68
LANEClient . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-70
LECS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-72
LECSELAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-74
LECSELANLEC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-77
LECSStat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-80
LECSTLVParam . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-82
LECSTLVSet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-84
LECSVCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-89
LES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-90
LESARP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-92
LESClient . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-93
LESELAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-95
LESLECStat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-98
LESStat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-100
MyNMAddr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-103
NetPrefix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-105
Passwd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-107
Ping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-108
PnniInterface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-109
PnniLink . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-111
PnniMetrics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-113
PnniNeighbor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-118
PnniNetworkLink . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-121
PnniNetworkNode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-124
PnniNode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-127
PnniNodeTimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-129
PnniPglElection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-132
PnniPtse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-135
PnniReachableAddress . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-137
PnniScopeMapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-139
PnniStats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-143
PnniSummaryAddress . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-145
PortConfig . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-148
PortMode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-152
PortStat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-154
PortTrafficCongestion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-158
Privilege . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-161
Prompt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-163
SmartCell 6A000/ZX-250 Reference Manual vii
Table of Contents
PVC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-164
PVCById . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-171
Reboot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-173
Route . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-175
Rows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-177
SARStat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-178
ServiceRegistry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-181
Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-183
SigStatistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-184
SigTimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-187
SSCOPConfig . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-189
SSCOPStatistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-191
SVC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-195
SVCById . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-197
Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-200
SwitchConfig . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-202
SwitchName . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-206
SwitchTrafficCongestion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-207
TrafficDescriptor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-209
TrapCommunity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-213
TrustedNMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-215
VCCMask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-217
3 Boot Load Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Accessing the Boot Load Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
chpi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
clfs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
dcfg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
df . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6
go . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7
he . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8
ponf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9
A Acronyms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
B Event/Alarm Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1
C Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-1
Telephone Assistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1
FAX Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1
Electronic Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1
Placing A Support Call . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1
Hardware Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-2
Software Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-2
viii SmartCell 6A000/ZX-250 Reference Manual
Table of Contents
Repair Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-2
Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I-1
SmartCell 6A000/ZX-250 Reference Manual ix
LIST OF TABLES
Table 1-1 List of Operators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
Table 1-2 Operator Table Explanation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
Table 1-3 Parameter Table Explanation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
Table 1-4 Description Table Explanation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
Table 1-5 Description Table Example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8
Table B-1 Event and Alarm Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-1
Table B-2 Event Severity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-2
Table B-3 Event ID Prefixes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-3
x SmartCell 6A000/ZX-250 Reference Manual
List of Tables
SmartCell 6A000/ZX-250 Reference Manual 1-1
1 INTRODUCTION
This reference manual describes the console commands for the SmartCell 6A000 and SmartCell ZX-250 ATM
switches. The two switches share a common console interface and are referred to in this manual as the SmartCell
6A000/ZX-250.
Audience and Scope
The manual is intended for network administrators and others responsible for maintaining the SmartCell
6A000/ZX-250. You do not need to read the manual from start to finish. You can use it to study the console commands
you use.
Definitions
The manual is organized alphabetically by switch attribute.
U The definition of a switch attribute is a function that manipulates the switch in a specific way. For
example, buselan.
U The definition of an operator is the active verb that makes the switch attribute perform a specific
task. For example, show.
U The definition of a command is the combination of an operator plus a switch attribute. For example,
show buselan.
Content
U Chapter 2, "SmartCell 6A000/ZX-250 Commands," gives definitions, descriptions, and examples of
all available commands on the SmartCell 6A000 and SmartCell ZX-250 switches.
U Chapter 3, “Boot Load Commands” gives definitions, descriptions, and examples of the low-level
boot load commands.
U Appendix A, “Acronyms,” spells out the ATM acronyms used in this manual as well as those found
in the SmartCell 6A000 User Guide, SmartCell ZX-250 User Guide, and SmartCell ZX
Administrator Installation Guide.
U Appendix B, “Event/Alarm Messages,” describes the format of event and alarm messages that are
recorded to circular buffers and can be displayed on the console.
U Appendix C, “Technical Support,” gives instructions for contacting Cabletron by telephone, fax,
electronic mail, and the World Wide Web.
1-2 SmartCell 6A000/ZX-250 Reference Manual
Introduction
Sections
Read "Switch Attribute" for an example and definition of the various sections under each switch attribute as well as a
description of how the manual is organized.
Each section begins with a switch attribute heading (for example, “PVCById”). Then come the details of relevant
operators, parameters, and commands.
Most sections have two parameter tables—one for input and another for output. The tables contain the parameter
names, descriptions, and definitions of their values, field sizes, and defaults.
The section ends with examples copied from the switch console for each console command for that switch attribute.
Conventions
The SmartCell 6A000/ZX-250 Reference Manual uses the following conventions to convey instructions and
information:
U Information you enter (console commands and input parameters) is shown in bold Courier 10 font
and requires a space between operator and switch attribute.
U Input and output parameters are shown in [Square Brackets].
U Input definitions are shown in <anglebrackets>, as joined text and not case sensitive.
U Filter flags </s> (summary) or </d> (detail) are available with certain show commands and apply to
different information viewing levels. Filter flags require a space between them and the full
command. For example, show client /d. The/s option is the same as the standard default option. You
can find more details at the relevant switch attribute sections. See the following examples:
switch_prompt # show client
ClientNumber(ALL) :
Client Type IP Address Server Type Server Conn Status
==============================================================================
1 LANE 90.1.1.186 LECS Established Operational
3 IP/ATM 90.1.1.124 Local Established Operational
switch_prompt #
switch_prompt # show client /s
ClientNumber(ALL) :
Client Type IP Address Server Type Server Conn Status
==============================================================================
1 LANE 90.1.1.186 LECS Established Operational
3 IP/ATM 90.1.1.124 Local Established Operational
switch_prompt #
switch_prompt # show client /d
ClientNumber(ALL) :
LANE Client 1
==============================================================================
Client State : Operational
Client Address : 39:00:00:00:00:00:00:00:00:00:14:15:00:00:20:D4:14:15:00:00
LAN Name : elan1
LECS Addr Source : ILMI
LECS Address : 39:00:00:00:00:00:00:00:00:00:14:15:00:00:20:D4:14:15:00:01
LES Address : 39:00:00:00:00:00:00:00:00:00:14:15:00:00:20:D4:14:15:00:02
LAN Type : 802.3
MTU : 1516
IP Address : 90.1.1.186
SmartCell 6A000/ZX-250 Reference Manual 1-3
Introduction
IP NetMask : 255.255.255.0
IP/ATM Client 3
==============================================================================
Client State : Operational
Client Address : 39:00:00:00:00:00:00:00:00:00:14:15:00:00:00:5A:01:01:7C:00
Server : is local
Server Connection : Established
MTU : 9180
IP Address : 90.1.1.124
Abbreviations
Pay close attention to how switch attributes appear in each section heading. Switch attributes are not case sensitive. If
the heading states BUSStat, you must type
busstat and not busstats, because the switch will not recognize the latter.
See the following example:
switch_prompt # show busstats
Command busstats not Valid for Action show
Type Help <command> for help
switch_prompt #
switch_prompt # show busstat
ELANNumber(ALL) :
BUS ELANs
============================================================================
ELAN ELAN000 Statistics
Out Octets : 0
Out Unicast : 0
switch_prompt #
You can, however, abbreviate the switch attribute to the extent that it is unique. For example, instead of typing show
porttrafficcongestion, you can just type show portt. The same can be done with operators. Instead of typing modify,
you can type mod. You should type at least three characters for any operator. For example,
switch_prompt # modify portmode
PortNumber(ALL) :
PortMode(SONET) :
switch_prompt #
switch_prompt # mod portm
PortNumber(ALL) :
PortMode(SONET) :
switch_prompt #
See "Switch Attribute" for an explanation of how the sections are organized.
1-4 SmartCell 6A000/ZX-250 Reference Manual
Introduction
Help Options
The console provides several levels of help for console commands. For example, to list the switch attributes that can
be used with a particular operator, enter the word
help (or ?) followed by the operator.
switch_prompt # help add
HELP ---- add
==============================================================================
add [ Alias | ATMRoute | BUSELAN | Community | ELAN | Interface |
IPATMClient | IPATMPVC | LANEClient | LECSELAN | LECSELANLEC |
LECSTLVSET | LESELAN | NetPrefix | PnniMetrics |
PnniSummaryAddress | PVC | Route | ServiceRegistry |
TrafficDescriptor | TrapCommunity ]
To get an explanation of a command and its parameters, enter the word help (or ?) before the command.
switch_prompt # ? add laneclient
Create LANE Client
==============================================================================
ClientNumber Local Client Number (0-127)
LanName Name of the ELAN to join
ServerType Type of LANE Server [LECS, LES]
ServerAddress ATM Address of the LANE Server
IPAddress IP Address of the Client
NetMask IP Netmask of the Client
MTU MTU for the Client [1516, 9234, NONE]
While entering a command, you can get help about an input parameter. To do so, enter a question mark (?) at the
parameter prompt.
switch_prompt # add atmroute
PortNumber(A1) : a3
AtmAddress() : 39:00:00:00:00:00:00:00:00:00:14:72:80
PrefixLength(104) :
Index(0) :
Type(Internal) : ?
The type of reachability. Use Internal, Exterior, or Reject.
Type(Internal) : exterior
Scope(0) :
MetricsTag(0) :
Switch 4 #
2p›F +ÀiÃÃÊÍ…iÊ.ÃVÊŽißÊÍœÊL>VŽÊœÖÍÊœvÊ>˜ßÊVœ““>˜`ÊLivœÀiÊßœÖÊi˜ÍiÀÊÍ…iÊ•>ÃÍÊÜ>•Öi°
Other Reference Options
You will find a list of acronyms, details about technical support, and an index at the back of this manual. The index
contains page references for all switch attribute sections, command parameters, operators, command descriptions and
command examples. There is also a table of commands at the end of this chapter. It lists all switch attributes by their
operator.
See the SmartCell 6A000 User Guide and SmartCell ZX-250 User Guide for details on how to use the switch. The user
guides contain information about switch configuration, maintenance, and SNMP (simple network management
protocol), as well as an overview of switch capabilities.
SmartCell 6A000/ZX-250 Reference Manual 1-5
Introduction
Switch Attribute
This section—immediately below the heading—gives a brief description of what the switch attribute does. A detailed
description of each command is available under “Descriptions.”
Parameters
Operators make the switch attribute work. Operators pertaining to each switch attribute are listed immediately below
the “Operators” heading. The command is the switch attribute combined with the operator. A list of possible switch
operators follows. You can use an alias when a word in parentheses appears. However, only the operators not in
parentheses are used in this manual.
:"*dF˜s_s /a’›˜pO˜3zF•"›p•’
3zF•"›p• "4›apm
add (create) Adds new object
activate Activates an existing but deactivated object
backup Backs up switch configuration
clear Clears (initializes to 0) properties of an object
disable Lowers privilege level
deactivate Deactivates an existing object
delete (remove) Deletes existing object
enable Raises privilege level
exit Exits from console
flush Flushes all entries
history Shows past console commands
modify (set) Sets properties of an existing object
passwd Changes passwords
reboot Reboots the switch
restart Restarts LANE clients
restore Restores switch configuration
setup Sets up switch
show (display) Shows properties of an object
shutdown Shuts down switch
start Starts server
stop Stops server
update Upgrades firmware
1-6 SmartCell 6A000/ZX-250 Reference Manual
Introduction
Operators
Parameters appear in the parameter tables in the same order and spelling as the switch shows them.
Most switch attribute descriptions show two tables—Input Parameter and Output Parameter. If the parameter has
already been described in the input parameter table, no reference to it appears in the output parameter table. The output
parameter table contains only parameters that have not been described in the input parameter table or that are written
very differently on output despite having the same meaning.
Only one parameter table in a switch attribute section means either that switch attribute uses only input parameters or
that the output parameters are identical to the input parameters. The heading of the table indicates which is the case. If
the table heading says Input Parameter or Output Parameter, only input or output parameters apply to this switch
attribute. However, if the table heading says Parameter, the table contains both input and output parameters, and their
field names and definitions are identical.
Some output parameters show either (</d>) or (</s>) to indicate that a filter flag is available and that parameter is
available only when you type either /d (detailed information) or /s (summarized information) after the command. If
you do not type these command extensions, the parameters do not appear. Further explanations are given at relevant
sections. See “PVC” for an example.
The following table gives details about several of the most common parameters in this manual; a shorter description
of these parameters appears at the relevant sections within the manual:
:"*dF˜s_¢ 3zF•"›p•˜:"*dF˜'¨zd"m"›apm
6"•"hF›F• &F’4•az›apm ="d¤F—)aFd=˜9a«F &FO"¤d
[Input or Output Field]
(</d>)
What the switch puts on your screen (either as input
or output) relating to the console command you are
executing. The [InputParameter] is an entry you
need to complete if you do not accept the default.
The [OutputParameter] shows information from the
switch. Requires no input. This example is available
only within the detailed information table.
Unit of measurement/
Maximum field size
for input entry.
Option
offered by
the switch.
:"*dF˜s_• 6"•"hF›F•˜:"*dF˜'¨zd"m"›apm
6"•"hF›F• &F’4•az›apm ="d¤F—)aFd=˜9a«F &FO"¤d›
[PortNumber] Port number on the switch. Port
numbers can be any of the physical
ports on the local switch. Specifying
"ALL" causes all related values for the
ports to be affected by the command.
Port B4 is the CPU port. The
SmartCell 6A000/ZX-250 reserve
this port for use by the CPU for local
servers and clients. Therefore, B4
port is usually not listed. Only ALL,
A1-A4, B1-B3, C1-C4, and D1-D4
are listed.
ALL or A1
SmartCell 6A000/ZX-250 Reference Manual 1-7
Introduction
With [IndexNumber], [PortNumber], [Client Number], and other parameters that default to “ALL”, unless you specify
a number at that input field, the switch gives ALL information pertaining to that parameter field.
Descriptions
[ATM Address] ATM address assigned to the port,
client, or server according to ATM
Forum specifications.
13-20 bytes. Hex-based,
dot-decimal format separated by
colons/
59 characters
usually no default
[ClientNumber] Number of the client. Each client on
the switch must have a unique client
number. Client numbers are shared
between LAN emulation (LANE)
clients and IP/ATM (IP over ATM)
clients.
0 through 127/
Up to 3 characters
ALL
:"*dF˜s_T &F’4•az›apm˜:"*dF˜'¨zd"m"›apm
3zF•"›p• 6"•"hF›F•’—6F•ha’’apm’ &F’4•az›apm
console
command
[InputParameter] <whatyoutype>
(Privilege level this console command
allows:)
Administrator or All
This section provides detailed descriptions of the command
(operator and switch attribute) and discusses what the
command does and how and when it is used. Other relevant
information appears here.
:"*dF˜s_• 6"•"hF›F•˜:"*dF˜'¨zd"m"›apm˜|%pm›am¤F=}
6"•"hF›F• &F’4•az›apm ="d¤F—)aFd=˜9a«F &FO"¤d›
1-8 SmartCell 6A000/ZX-250 Reference Manual
Introduction
The following is an example of a description section. It is located under "BUSELAN." Note the detailed description
of the command following the table.
Examples
Examples are copied exactly from the switch console to show you what you should see. They appear at the end of each
section in the same order as the operators are listed at the start of each section. There is no significance to the order in
which the examples appear, except that show usually appears after the other command examples to demonstrate how
a command can change a characteristic of the switch. Unless they fit on the current page, examples usually begin at
the top of a page. The location of every command example appears in the index under "Examples".
Examples show how you must enter console commands at the switch prompt (indicated in bold - modify buselan
(console command)). The other bold text (1, 103, pvc, 802.5, 4544) is the input parameters that modify this switch
attribute (BUSELAN). The text in brackets (immediately following the parameter field - for example,
ELANType(802.3)) indicates the current default. See the following examples.
switch_prompt # modify buselan(console command)
ELANNumber(0) :103(input entry)
ELANName(ELAN102) :elan103(input entry)
ConnectMethod(SVC) :pvc(input entry)
ELANType(802.3) :802.5(input entry)
Multipoint(YES) : (accept default)
MTU(1516) :4544 (input entry)
switch_prompt #
switch_prompt # show buselan
ELANNumber : 103
ELAN : elan103
ELAN Number : 103
ELAN Name : elan103
ATM Address :39:00:00:00:00:00:00:00:20:D4:14:15:00:00:20:D4:14:15:66:02
Max Frame Size : 4544
Connection Method : PVC
Distribute VPI/VCI: 0/50
LAN Type : 802.5
Multipoint : YES
:"*dF˜s_Q &F’4•az›apm˜:"*dF˜'¨"hzdF
3zF•"›p• 6F•ha’’apm’—6"•"hF›F•’ &F’4•az›apm
modify buselan
[ELANNumber]
<elannumber>
[ELANName]
<elanname>
[ConnectMethod] <
connectmethod
>
[ELANType] <
elantype
>
[Multipoint] <
distributevcctpe
>
[MTU] <
maximumframesize
>
Administrator
Changes the behavior of the BUS parameters for a
specified ELAN. The specified ELAN is then
deleted and recreated. If the corresponding
LESELAN exists, then the modified BUSELAN
should have the same characteristics as that
existing LESELAN because their parameters need
to match.
SmartCell 6A000/ZX-250 Reference Manual 1-9
Introduction
List of Commands and Possible Switch Attributes
add (create)
delete (remove)
Alias ATMRoute BUSELAN Community
ELAN IPATMClient IPATMPVC LANEClient
LECSELANLEC LECSTLVSET LESELAN LECSELAN
NetPrefix PnniMetrics PnniSummaryAddress PVC
Route ServiceRegistry TrafficDescriptor TrapCommunity
Alarms Alias ATMRoute BUSClient
BUSELAN Client Community ELAN
Events IPATMPVC LECSELAN LECSELANLEC
LECSTLVPARAM LECSTLVSET LESClient LESELAN
NetPrefix PnniMetrics PnniSummaryAddress PVC
PVCById Route ServiceRegistry TrafficDescriptor
TrapCommunity
1-10 SmartCell 6A000/ZX-250 Reference Manual
Introduction
modify (set)
AlarmDisplay Alias BUSELAN CACEqBwAllocScheme
CACServiceClassBw ConsoleTimeout CoreDump EventDisplay
IlmiTimers IPAddress IPATMClient LANEClient
LECSELAN LECSELANLEC LECSTLVSET LESELAN
MyNmAddr PnniInterface PnniNode PnniNodeTimer
PnniPglElection PnniScopeMapping PortConfig PortMode
PortTrafficCongestion Prompt Rows SigTimer
SSCOPConfig SwitchConfig SwitchName SwitchTrafficCongestion
TrustedNMS VCCMask
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268
  • Page 269 269
  • Page 270 270
  • Page 271 271
  • Page 272 272
  • Page 273 273
  • Page 274 274
  • Page 275 275
  • Page 276 276

Cabletron Systems SmartCell ZX-250 Reference guide

Type
Reference guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI