RAB SMKEZPAN1X4 is a versatile LED fixture designed for recessed ceiling mounting in both insulated and non-insulated ceilings. It features a sleek, low-profile design with a polystyrene lens for uniform light distribution. With its energy-efficient LEDs, the SMKEZPAN1X4 provides bright, long-lasting illumination while saving on energy costs. The fixture is suitable for damp locations and comes with pre-installed grid clips for easy installation in standard 9/16" or 15/16" flat tee grids.

RAB SMKEZPAN1X4 is a versatile LED fixture designed for recessed ceiling mounting in both insulated and non-insulated ceilings. It features a sleek, low-profile design with a polystyrene lens for uniform light distribution. With its energy-efficient LEDs, the SMKEZPAN1X4 provides bright, long-lasting illumination while saving on energy costs. The fixture is suitable for damp locations and comes with pre-installed grid clips for easy installation in standard 9/16" or 15/16" flat tee grids.

RAB Lighting is committed to creating high-quality, aordable, well-designed and energy-ecient LED lighting and controls that make it easy for electricians to install
and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.



WARNING: Make certain power is OFF before installing or maintaining xture. No user serviceable parts inside.
INSTALLATION INSTRUCTIONS
® 1X4, 2X2, 2X4

WARNING: Risk of re or electric shock. Suitable for Damp locations.
WARNING: Suitable for 9/16” or 15/16” Flat Tee Grid in both Insulated Ceilings and Non-Insulated Ceilings. Access above ceiling required.
WARNING: Do not handle energized xture when hands are wet, when standing on wet or damp surfaces, or in water.
WARNING: Vapor barrier must be suitable for 90° C.
WARNING: Fixture to be independently supported to building structure.
EZPAN 1X4 EZPAN 2x2 EZPAN 2x4





  Grid Clips (up and out as shown
in Fig. 1).
 Fixture
Tee-Grid Bar
FixtureTee-Grid Bar
 
FixtureSupport Wires (supplied by
others) Grid Clip Hole 
 Splice BoxAccess
Plate


Fixture Firmly bend Grid
Clips up and out
Splice Box Access Plate Screw
Tee-Grid Bar
Fixture
Grid Clip
RAB Lighting is committed to creating high-quality, aordable, well-designed and energy-ecient LED lighting and controls that make it easy for electricians to install
and end users to save energy. Wed love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.
INSTALLATION INSTRUCTIONS
® 1X4, 2X2, 2X4


Conduit
Knockout
Power Feed Grid Clip
Support Wire
(supplied by
others)
Grid Clip Hole
Access Plate



Fig. 5

 LINE 
 COMMON
 GROUND GROUND
 
 (or gray)
NOTE: Do not connect DIM V+ (purple)/ DIM V- (pink/gray) to line
voltage or supply ground.
PINK (or GRAY)
LIGHT
FIXTURE
Vaux 12V
YELLOW
GROUND
GROUND
( - ) DIM V
( + ) DIM V
COMMON
LINE BLACK
WHITE
PURPLE


CAUTION: Be sure xture temperature is cool enough to
touch. Do not clean or maintain while xture is energized.
 

 

 
2. 
CONT.
 Access Plate Screw Access Plate
Conduit KnockoutsAccess
Plate 
Fig. 4
 
Splice Box.

WARNING: To prevent wiring damage or
abrasion, do not expose wiring to edges of sheet metal or
other sharp objects.
 Access PlateAccess Plate Screw.
RAB Lighting is committed to creating high-quality, aordable, well-designed and energy-ecient LED lighting and controls that make it easy for electricians to install
and end users to save energy. Wed love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]
Easy Answers
rablighting.com
Visit our website for product info
Tech Help Line
Call our experts: 888 722-1000
e-mail
Answered promptly - [email protected]
Free Lighting Layouts
Answered online or by request
© 2022 RAB LIGHTING Inc.
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.
EZPAN 1X4, 2X2, 2X4 - 0522
INSTALLATION INSTRUCTIONS
® 1X4, 2X2, 2X4
73534-RAB
 

LIGHT
FIXTURE
INSIDE FIXTURE
BATTERY
Pink (or Gray)/DIM–
Black/Switched Line
Green/Ground
White/Neutral
Black/Unswitched Line
Purple/DIM+
BACKUP
DRIVER
BATTERY
CONNECTOR:
CONNECT
ONLY AFTER
AC SUPPLY
POWER IS
CONNECTED

CAUTION: THIS IS A BATTERY BACKUP FIXTURE for standby
lighting. Voltage could be present in Battery. To prevent high
voltage from being present on output leads, inverter connector
must be open. Do not join inverter connector until installation is
complete and AC power is supplied to the emergency ballast.
Note: 

Fig. 6

 

 
 

 COMMON COMMON

 
(or gray)
 
 
 

 


 



 

 
internal battery


 




 

 

 


Battery Backup Setting
PRODUCT WATTAGE DIP SWITCH
POSITION (12W)
EZPAN 1X4 17
EZPAN1X4 30, 40
EZPAN 2X2 17 1 = O
2 = On
EZPAN 2X2 30, 40
EZPAN 2X4 30, 40, 50

  • Page 1 1
  • Page 2 2
  • Page 3 3

RAB SMKEZPAN1X4 User manual

Type
User manual

RAB SMKEZPAN1X4 is a versatile LED fixture designed for recessed ceiling mounting in both insulated and non-insulated ceilings. It features a sleek, low-profile design with a polystyrene lens for uniform light distribution. With its energy-efficient LEDs, the SMKEZPAN1X4 provides bright, long-lasting illumination while saving on energy costs. The fixture is suitable for damp locations and comes with pre-installed grid clips for easy installation in standard 9/16" or 15/16" flat tee grids.