Mastervolt Switch Input 4 PCB Installation guide

Type
Installation guide

This manual is also suitable for

Installation manual Switch Input 3 / 4 English
Mastervolt International B.V, P.O.Box 22947, NL-1100 DK Amsterdam, The Netherlands. Tel.: +31-20-3422100 Email: [email protected]m Copyright © Mastervolt v1.0 090130EN
4
Assemble the device and connect the wires.
C. Insert the
MasterBus
cables
at the back side
of the device like
shown below.
B. Mount the frame to the
wall or to your dash
board.
A. Click the Carling switches into the
frames and press the switch lips firmly
into the fastons like shown
MasterBus
Terminator
Contact your supplier if one of the items is missing.
Do not use the Switch Input if it is damaged.
Switch Input 3 or Switch Input 4
Installation
manual
3
Check the contents of the delivery.
1
This Quick installation guide provides a brief overview of a Switch Input 3 or 4 installation.
Reading the user’s manual is still necessary for safety instructions, additional features, best performance and
years of trouble-free service. The Switch Input 3 / 4 manual is available at www.Mastervolt.com.
2
Read the safety instructions (chapter 2 of the user’s manual).
Safety regulations and measures
1. Install the switch according to the instructions in both the user’s and installation manual.
2. Never use switches at a location where there is danger of gas or dust explosions.
3. Connections and safety features must be executed according to locally applicable regulations.
Mastervolt cannot be held liable for:
Damage resulting from the use of the switches;
Possible errors in the included manual and the consequences of these;
Use that is inconsistent with the purpose of the product.
Installation manual Switch Input 3 / 4 English
Mastervolt International B.V, P.O.Box 22947, NL-1100 DK Amsterdam, The Netherlands. Tel.: +31-20-3422100 Email: [email protected]m Copyright © Mastervolt v1.0 090130EN
Variable Decription Default Range
Configuration at the Switch Input
Language Language setting of the Switch Input. English 10 languages
Device name Name of your Switch Input in the MasterBus system. If
you have more than one Switch Input you should
change names.
DSI Switch in 3,
DSI Switch in 4
DSI + any
maximum 12
character name.
Events
locked
Option to disable event configuration on the device.
Operable by installer only (log in required).
Unchecked Unchecked,
Checked
Switch X Name of switch number X. X ranges 1-3 (1-4). Naming
the switches after their application is convenient, for
instance “SW Anchor Light” for the anchor light switch.
Switch X Any maximum
16 character
name.
Feedback X Name of feedback number X. X ranges 1-3 (1-4). This
feedback indicates the device selected has been
switched On and is functioning. Naming the feedbacks
after their application is convenient, for instance “FB
Anchor Light” for the anchor light feedback.
Feedback X Any maximum
16 character
name.
5
Configure the Switch Input for MasterBus communication
(see user’s manual for event configuration):
Dimensions of a complete set in mm [inch]
86 3,40
58
2,30
76 3,01
54 2,12
48
1,89
65
2,55
120 4,70
110 4,33
108 4,25
53 2,08
56 2,19
12
0.47
42
1.65
53
2.09
6
0.24
6 0.24
Specifications Switch Input 3 Switch Input 4
Article number 77031300 77031400
Number of configurable events 63 63
Power consumption 0.19 mA 0.19 mA
IP factor 21 21
Weight 35 g including terminator 45 g including terminator