Extron TLP Pro 1022M User manual

Type
User manual

Extron TLP Pro 1022M is a 10-inch wall-mountable touchscreen with 1024x600 resolution and 18-bit color depth. It offers flexible mounting options and fully customizable interfaces for controlling audiovisual systems, lighting, shades, and other devices. With its built-in motion sensor, the TLP Pro 1022M can automatically wake from sleep mode when someone approaches, making it ideal for use in conference rooms, classrooms, and other shared spaces.

Extron TLP Pro 1022M is a 10-inch wall-mountable touchscreen with 1024x600 resolution and 18-bit color depth. It offers flexible mounting options and fully customizable interfaces for controlling audiovisual systems, lighting, shades, and other devices. With its built-in motion sensor, the TLP Pro 1022M can automatically wake from sleep mode when someone approaches, making it ideal for use in conference rooms, classrooms, and other shared spaces.

1
IMPORTANT:
Go to www.extron.com for the
complete user guide and installation
instructions befor
e connecting the
pr
oduct to the power sou
rce.
www.extron.com
TLP Pro 1022M • Setup Guide
Overview
The TLP Pro 1022M is a 10-inch wall-mount capacitive touchscreen with 1024x600 resolution and 18-bit color depth. It offers exible
mounting options and fully customizable interfaces. This guide provides instructions for experienced installers to mount and install a
TLP Pro 1022M touchpanel. For more complete instructions, see the TLPPro1022 Series User Guide, at www.extron.com.
Setup Checklist
Get Ready
Download and install the latest version of the following software:
GUI Designer — for designing layouts for Extron TouchLink
®
Pro touchpanels and third party touch interfaces.
Global Configurator Professional or Global Configurator Plus — for setting up and conguring the control processor and
touchpanel.
Toolbelt — provides device discovery, device information, rmware updates, and conguration of network settings, system
utilities, and user management for TouchLink Pro devices.
All three software programs are available from www.extron.com.
Obtain the following network information from your network administrator:
DHCP status — (on or off). If DHCP is off, you must also obtain
IP address Subnet mask Gateway
User name — this can be either admin or user.
Password — by default this is extron (for either admin or user).
Make a note of the touchpanel MAC address.
Mount and Cable All Devices
ATTENTION:
Do not power on the touchpanels or control processors until you have read the Attention in the “Rear Panel Features”
section of the TLP Pro 1022 Series User Guide or the IPCP Pro User Guide or IPL Pro User Guide.
Ne branchez pas les écrans tactiles ou les contrôleurs avant d’avoir lu la mise en garde dans la section «Rear Panel
Features» du TLP Pro 1022 Series UserGuide ou du IPCP Pro User Guide or IPL Pro User Guide.
Mount the units. There are several mounting options for TouchLink Pro touchpanels (see Mounting on the next page).
Connect the touchpanel to a Power over Ethernet injector.
Connect the power injector to the LAN and power it on.
Set up the Touchpanels for Network Communication
Connect the PC that you are using for setup, the control processor, and touchpanel to the same Ethernet subnetwork.
Use the Setup Menu (see page 4) or Toolbelt to set the DHCP status and, if necessary, the IP address, subnet mask, gateway,
and related settings for the touchpanel.
Configure the Touchpanels
The GUI Designer Help File, the Global Configurator Help File, and the Toolbelt Help File provide step-by-step instructions and more
detailed information. The Global Configurator Help File includes an introduction to the software and sections on how to start a project
and conguration.
2
TLP PRO 1022M • Setup Guide (Continued)
Mounting
Wall-Mounting or Furniture-Mounting
The TLP Pro 1022M can be wall-mounted, either using the Extron BB 710M wall box or directly into drywall.
ATTENTION:
Do not install the TLP Pro 1022M in a re resistant rated wall or partition assembly.
Ne pas installer le TLP Pro 1022M dans un mur résistant au feu ou une cloison.
All structural steps and electrical installation must be performed by qualied personnel in accordance with local and
national building codes and electrical codes.
Toute étape structurelle et installation électrique, doit être effectuée par un personnel qualié, conformément aux
codes du bâtiment, aux codes incendie et sécurité, et aux codes électriques, locaux et nationaux.
With a wall box
Some local building codes require the
touchpanel to be mounted in a wall box
such as the optional Extron BB 710M. This
installation procedure is described below.
1. Cut a hole in the drywall,
7.70 inches (19.56 cm) wide x 6.00 inches
(15.24 cm) high, and install the BB 710M,
as described in the BB 710M Installation
Guide (see www.extron.com).
2. Place the metal mounting plate against
the wall, mark the four mounting holes,
and drill four pilot holes.
3. Fasten the mounting plate to the wall with
four #10 screws (not provided).
4. Run and connect cables to the back of
the touchpanel (see Rear Panel Features
on the following page).
5. Insert the two provided Phillips pan head
#6-32 x ¾ inch length screws with
washers in the mounting screw slot.
6. Hold the touchpanel at a slight angle and
lower the notches at the top of the back
panel over the hooks of the mounting
plate.
7. Swing the bottom of the touchpanel
inwards so that it lies at against the
mounting plate with the tongue at the
bottom of the mounting plate sitting in a
groove in the bottom of the touchpanel.
8. Fasten the touchpanel to the mounting
plate with the mounting screws.
Figure 1. Mounting the TLP Pro 1022M
Without a wall box
If the wall box is not required by local building codes, you can mount the touchpanel directly into drywall.
1. Download the cut-out template for your touchpanel from www.extron.com. Print it at 100% (no scaling).
2. Use the template to mark the wall, cut the hole, and drill the four pilot holes.
The size of the cut-out hole is 7.70 inches (19.30 cm) wide x 6.00 inches (15.24 cm) high.
NOTE: You can also use the mounting plate as a template to mark where the hole should be cut out and the pilot holes
should be drilled.
3. Fasten the mounting plate and complete the installation, as described in steps 3-8 above.
install BB 710M,
and run the cables.
TLP PRO 1022M
Hold the Touch Panel at a slight angle.
Mount the Touch Panel over the two
hooks on the Mounting Plate.
Add the Mounting Plate.
Align w/ Wall Box.
Mark holes for screws.
Fasten the Mounting Plate
to the wall with screws (4).
Fasten the Touch Panel
to the Mounting Plate
w/ Pan Head Screws (2) in
base of Touch Panel.
6
8
5
2
1
Rear View
3
Insert pan head screws
with washers (2) into the
mounting screw slot.
3
Product Category
Front Panel Features
E
D
B
E
A C
F
Figure 2. TLP Pro 1022M Front Panel
A
Communication LED — shows the conguration and connection status of the touchpanel:
z Unlit during normal operation (the touchpanel is congured and connected to an IP Link Pro control processor).
z Blinks red if the touchpanel has been congured but is not connected to an IP Link Pro control processor.
z Continuously lit red if the touchpanel has not been congured and is not connected to an IP Link Pro control processor.
The indicator can be toggled between enabled and disabled, using the Setup Menu (see page 4).
B
Status lights — one LED light bar, above the screen, which can be programmed to provide system feedback.
z Light red or green
z Blink or light continuously
z For information about programming this light, see the Global Configurator Help File.
C
Light sensor — monitors ambient light level and adjusts screen brightness.
D
Capacitive touchscreen — 10.1-inch screen with 1024x600 resolution.
E
Speakers — two speakers, located below the screen, one on each side of the panel, provide audible feedback for the user.
F
Motion sensor — detects motion between three to ve feet from the touchpanel, and at least 15° from the center axis.
z When no motion has been detected for a user-dened period of time, the touchpanel enters sleep mode.
z When motion is detected by the sensor, the screen display is restored and active.
Rear Panel Features
D
A
B
C
E
Figure 3. TLP Pro 1022M Rear Panel
A
Reset LED— provides feedback about the reset status when the user presses the Reset button (see Reset Modes, on the
following page).
B
Reset button— pressing the Reset button allows the unit to be reset in any of three different modes (for an overview, see Reset
Modes, on the following page. For full information about the modes, see the TLPPro 1022 Series User Guide).
C
Menu button— activates the setup menu (see Setup Menu, on the following page).
A
Reset LED
B
Reset Button
C
Menu Button
D
LAN/PoE (Power over Ethernet) Connector
E
Mounting Holes (4)
4
68-2405-52 Rev. A
04 16
Extron Headquarters
+1.800.633.9876 (Inside USA/Canada Only)
Extron USA - West Extron USA - East
+1.714.491.1500 +1.919.850.1000
+1.714.491.1517 FAX +1.919.850.1001 FAX
Extron Europe
+800.3987.6673
(Inside Europe Only)
+31.33.453.4040
+31.33.453.4050 FAX
Extron Asia
+65.6383.4400
+65.6383.4664 FAX
Extron Japan
+81.3.3511.7655
+81.3.3511.7656 FAX
Extron China
+86.21.3760.1568
+86.21.3760.1566 FAX
Extron Middle East
+971.4.299.1800
+971.4.299.1880 FAX
Extron Australia
+61.8.8351.2188
+61.8.8351.2511 FAX
Extron India
1800.3070.3777
(Inside India Only)
+91.80.3055.3777
+91.80.3055.3737 FAX
© 2016 Extron Electronics All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com
TLP PRO 1022M • Setup Guide (Continued)
D
LAN/PoE connector (see figure 3,
D
on the previous page) — Connect the touchpanel to a PoE power injector (not provided)
using a twisted pair cable, terminated with an RJ-45 connector. Connect the power injector to the LAN through a nework switch.
An Extron IP Link Pro control processor must also be connected to the same network as the TouchLink Pro touchpanel.
ATTENTION:
The TLP Pro 1022M is Power over Ethernet (PoE 802.3af, class 3) compliant. Do not power on the touchpanels
or control processors until you have read the Attention in the “Rear Panel Features” section of the TLP Pro 1022
Series User Guide or the IPCP Pro User Guide or IPL Pro User Guide.
Le TLP Pro 1022M est compatible avec l’alimentation POE via Ethernet (PoE 802.3af, classe 3). Ne branchez pas
les écrans tactiles ou les contrôleurs avant d’avoir lu la mise en garde dans la section «Rear Panel Features » du
TLP Pro 1022 Series User Guide ou du IPCP Pro User Guide or IPLProUserGuide.
NOTE: The TLP Pro 1022M is shipped without a power injector. The power
injector must be purchased separately.
The gure to the right shows the Extron XTP PI 100. Your power injector may look
different.
E
Mounting holes (4) (see figure 3,
E
on the previous page) — for wall mounting (see
page 2).
Reset Modes: a Brief Summary
The TLP Pro 1022M offers the following reset modes (see the TLP Pro 1022 Series User Guide for complete information):
Use Factory Firmware:
Press and hold the
Reset button (figure 3,
B
) while applying power to the unit. Use this
mode with Global Congurator or Toolbelt software to replace rmware in the event of
conicts arising from uploading a rmware update.
Reset All IP Settings:
Press and hold the
Reset button for 6 seconds. After the Reset LED (figure 3,
A
) ashes
twice, release and momentarily press the
Reset button. Use this mode to reset all network
settings without affecting user-loaded les.
Reset to Factory
Defaults:
Press and hold the
Reset button for 9 seconds. After the Reset LED (figure 3,
A
) ashes
three times, release and momentarily press the
Reset button. Use this mode to return the
touchpanel to factory default settings.
Setup Menu
Press the Menu button (figure 3,
C
on the previous page) to open the setup
menu. Select any of the ve available screens (Status, Network, Display,
Audio, and Advanced) by pressing the appropriate button in the navigation
bar at the top of the screen (for more information, see the TLPPro 1022
Series User Guide).
Press the
Menu button for at least 3 seconds to open the calibration screen.
Follow the on-screen instructions.
Status
Display Audio Advanced Exit
Network
Info
Model: TLP Pro 1022M
Part Number: 60-1602-02
Firmware
Version:
1.00
PoE Status: On
Network
IP Address:
DHCP:
Host Name:
Off
192.168.254.251
TLP-AB-CD-EF
Display
Resolution:
Project:
Sleep Timer:
1024x600
N/A
5 Minutes
Audio
Master Volume:
Master Mute: Off
99
Advanced
Controller IP: N/A
Project Size: N/A
Figure 4. Setup Menu: Status Screen for TLP Pro 1022M
100-240V
~
50-60Hz
0.4A MAX
XTP
PWR
XTP PWR
To network switchTo touchpanel
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Extron TLP Pro 1022M User manual

Type
User manual

Extron TLP Pro 1022M is a 10-inch wall-mountable touchscreen with 1024x600 resolution and 18-bit color depth. It offers flexible mounting options and fully customizable interfaces for controlling audiovisual systems, lighting, shades, and other devices. With its built-in motion sensor, the TLP Pro 1022M can automatically wake from sleep mode when someone approaches, making it ideal for use in conference rooms, classrooms, and other shared spaces.