RTS Icw-6 User manual

Category
Door intercom systems
Type
User manual
F.01U.193.293
Rev. 05
9/12/12
ICW-6 Window Intercom
Installation and Operation Instructions
2 ICW-6 Window Intercom
Bosch Security Systems, Inc.
Installation Manual
F.01U.193.293
Rev. 05
Proprietary Notice
The product information and design
disclosed herein were originated by and are
the property of Bosch Security Systems, Inc.
Bosch reserves all patent, proprietary design,
manufacturing, reproduction, use and sales
rights thereto, and to any article disclosed
therein, except to the extent rights are
expressly granted to others.
Copyright Notice
Copyright 2012 by Bosch Security Systems,
Inc. All rights reserved. Reproduction, in
whole or in part, without prior written
permission from Bosch is prohibited.
Warranty Notice
See the enclosed warranty card for further
details.
Customer Support
Technical questions should be directed to:
Customer Service Department
Bosch Security Systems, Inc.
12000 Portland Avenue South
Burnsville, MN 55337 USA
Telephone: 800-392-3497
Fax: 800-323-0498
Factory Service: 800-553-5992
Return Shipping Instructions
Parts & Service Department
Bosch Security Systems, Inc. (Lincoln, NE)
Telephone: 402-467-5321
Fax: 402-467-3279
Factory Service: 800-553-5992
Please include a note in the box which
supplies the company name, address, phone
number, a person to contact regarding the
repair, the type and quantity of equipment, a
description of the problem and the serial
number(s).
Shipping to the Manufacturer
All shipments of product should be made via
UPS Ground, prepaid (you may request from
Factory Service a different shipment
method). Any shipment upgrades will be
paid by the customer. The equipment should
be shipped in the original packing carton. If
the original carton is not available, use any
suitable container that is rigid and of
adequate size. If a substitute container is
used, the equipment should be wrapped in
paper and surrounded with at least four (4)
inches of excelsior or similar shock-
absorbing material. All shipments must be
sent to the following address and must
include the Proof of Purchase for warranty
repair. Upon completion of any repair the
equipment will be returned via United Parcel
Service or specified shipper, collect.
Factory Service Department
Bosch Security Systems, Inc.
8601 East Cornhusker Hwy.
Lincoln, NE 68507 U.S.A.
Attn: Service
Table
of
Contents
F.01U.193.293
Rev. 05
Installation ManualBosch Security Systems, Inc.
INTRODUCTION ......................................................................1
Unpacking and Inspection ............................................................... 1
Recommended Items ........................................................................ 2
Specifications ................................................................................... 2
Accessories ...................................................................................... 3
INSTALLATION AND OPERATION ......................................1
Installation ....................................................................................... 1
Operation ......................................................................................... 6
Inside and Outside Mic Adjustment Pot .......................................... 6
Mic Adjustment Pot Location ................................................................ 6
Notes ................................................................................................ 9
2 ICW-6 Window Intercom
F.01U.193.293
Rev. 05
Installation Manual
Bosch Security Systems, Inc.
Bosch Security Systems, Inc.
Installation Manual
F.01U.193.293
Rev. 05
CHAPTER 1
Introduction
IMPORTANT: Use the power supply included with the ICW-6. Use of any
other power supply could damage the ICW-6 and will void the
warranty.
Unpacking and Inspection
Unpack the equipment from the shipping case and inspect for missing or damaged
components. You should have all of the items listed in Figure 1 .
ICW-6 Package
A. Cordset - European
B. Cordset - U.S.A.
C. ICW-6 Final Assembly
1. Operator-Side Assembly
2. Customer-Side Assembly
D. Switching Power Supply
E. Installation Kit
#6 screws 1” (3)
#6 washers (3)
•Cable Tie
F. User Manual (not shown)
G. Mounting Template (not shown)
H. Quick Start Guide (not shown)
I. Warranty Card (not shown)
FIGURE 1. ICW-6 System Components
Bosch Security Systems, Inc.
Installation Manual
F.01U.193.293
Rev. 05
2 Introduction ICW-6 Window Intercom
Recommended Items
No.1 Phillips screwdriver
Equipment for cutting/drilling hole(s) for mounting (See
Installation section for details)
1” wide transparent tape
Scissors (For cutting the mounting template from the last
page).
Specifications
General
Power Requirement
50mA max @ 110-240VAC, 5VDC 600mA maximum
System Frequency Response
200 to 4.5 kHz ±3 dB
Environmental
-20° C to 55° C, 0% to 90% humidity, non-condensing
Outputs
External Speaker
2W: 100dB SPL at 1ft. at 1 kHz, C weighting
Internal Speaker
2W: 100dB SPL at 1ft. at 1 kHz, C weighting
Note: These are sine wave maximums. Voice measurements will range 70 to 90 dB SPL.
Headphones
80 mW: 100dB peak SPL
Voice Range: 84 to 104 dB SPL
Impedance: 50
Inputs
Internal Panel Microphone
Electret: 4 mv at 1kHz, typical into 1000 ohms source impedance
External Headset Microphone
Dynamic: range 4 mv at 1kHz, typical into 200 ohms
Source Impedance Dynamic: 200 ohms
Options
Gooseneck Microphone
MCP-90-3, MCP-90-8, MCP-90-12, MCP-90-18
Headsets
PH-44-IC3 (Dual Headphone), PH-88-IC3 (Single Headphone)
Bosch Security Systems, Inc.
Installation Manual
F.01U.193.293
Rev. 05
ICW-6 Window Intercom Introduction 3
Accessories
Description Part Number
MCP-90-12
301029000
MCP-90-18
301030000
PH-88-IC3
300852300
PH-44-IC3
300853300
PH-88-IC3-QD
300853301
PH-44-IC3-QD
300853300
Bosch Security Systems, Inc.
Installation Manual
F.01U.193.293
Rev. 05
4 Introduction ICW-6 Window Intercom
Bosch Security Systems, Inc.
Installation Manual
F.01U.193.293
Rev. 05
CHAPTER 2
Installation and
Operation
Installation
1. Remove the two (2) screws holding the mounting plate to the operator assembly.
(See Figure 2 .)
FIGURE 2. ICW-6 Assembly Detail
Bosch Security Systems, Inc.
Installation Manual
F.01U.193.293
Rev. 05
2 Installation and Operation ICW-6 Window Intercom
2. Measure and identify the location where the intercom is to be mounted.
3. Attach the mounting template (supplied in box) to the window (customer
assembly side) being sure to center the appropriate guide in the location identified
in step 2.
NOTE: Use either the single large hole, or multiple small holes depending
on which method you choose. Using the multiple small hole
method with bullet-proof glass will afford maximum operator
protection (Figure 4).
4. Cut and/or drill the hole(s) from the customer assembly side.
5. Have an assistant place the customer assembly against the window. Make sure
the holes line up correctly.
6. Attach the mounting plate removed from the operator assembly (See Step 1)
using the three (3) supplied mounting screws and rubber washers. (See Figure 5).
7. Remove the lower left screw and washer and attach the ground wire (See
Figure 6).
CAUTION: Do not let the intercom hang by the ground wired. The connection
may break.
8. Attach the cable harness from the customer assembly to the connector on the
operator assembly (See Figure 6).
9. Attach the operator assembly to the mounting plate using the screws removed
in Step 1.
10. Screw the threaded end of the ICW-6 power supply interface cord into the ICW-
6. The connector is located on the bottom of the ICW-6 on the operator assembly
side.
11. Secure the cord to the glass using wide clear adhesive tape.
12. Connect the power supply to AC power using the supplied IEC cord.
Bosch Security Systems, Inc.
Installation Manual
F.01U.193.293
Rev. 05
ICW-6 Window Intercom Installation and Operation 3
13. Attach the ICW-6’s power cord to the power supply.
FIGURE 3. Operator and Customer assemblies
FIGURE 4. Mounting Template
Bosch Security Systems, Inc.
Installation Manual
F.01U.193.293
Rev. 05
4 Installation and Operation ICW-6 Window Intercom
FIGURE 5. Customer Side Mounted
Bosch Security Systems, Inc.
Installation Manual
F.01U.193.293
Rev. 05
ICW-6 Window Intercom Installation and Operation 5
FIGURE 6. Connecting customer and operator assemblies prior to final
mounting.
Bosch Security Systems, Inc.
Installation Manual
F.01U.193.293
Rev. 05
6 Installation and Operation ICW-6 Window Intercom
Operation
Inside and Outside Mic Adjustment Pot
On the ICW-6, you can adjust the sensitivity of the inside and outside mic. This
means the how far away from the microphone a person can stand to talk and still be
heard.
Mic Adjustment Pot Location
By default, the following applies:
The inside mic is set midpoint, 2”- 3” Speak Zone
The outside mic is set midpoint, 1’ - 2’ Speak Zone
Bosch Security Systems, Inc.
Installation Manual
F.01U.193.293
Rev. 05
ICW-6 Window Intercom Installation and Operation 7
FIGURE 7. ICW-6 Inside and Outside Mic Pot Location
To adjust the inside or outside mic sensitivity level, do the following:
1. Using a small screwdriver, remove the two (2) side screws from the operator
side unit.
2. Carefully remove the back plate from the operator side unit.
3. Using Figure 7 , locate the mic pot you want to adjust.
4. With a flathead screwdriver, turn the mic pot clockwise to increase the
sensitivity.
OR
Turn the mic pot counter-clockwise to decrease the sensitivity.
FIGURE 8. Side Screws Holding the Back Plate to the Operator Unit
Bosch Security Systems, Inc.
Installation Manual
F.01U.193.293
Rev. 05
ICW-6 Window Intercom Installation and Operation 9
Notes
Bosch Security Systems, Inc.
12000 Portland Avenue South
Burnsville, MN 55337 U.S.A.
www.boschcommunications.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18

RTS Icw-6 User manual

Category
Door intercom systems
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI