In the event that the side wall horizontally vented gas
fueled equiprnent is installed in a crawl space or an attic,
the hard wired carbon rnonoxide detector with alarm and
battery back-up may be installed on the next adjacent floor
level.
In the event that the requirernents of this subdivision can
not be rnet at the time of cornpletion of installation, the
owner shall have a period of thirty (30) days to comply
with the above requirernents; provided, however, that dur-
ing said thirty (30) day period, a battery operated carbon
monoxide detector with an alarm shall be installed.
Approved carbon monoxide detectors: each carbon monoxide
detector as required in accordance with the above provisions
shall comply with NFPA720 and be ANSI/UL 2034 listed and
IAS certified.
3. Signage: a metal or plastic identification plate shall be perrna-
nently mounted to the exterior of the building at a rninimum
height of eight (8) feet above grade directly in line with the
exhaust vent terminal for the horizontally vented gas fueled
heating appliance or equipment. The sign shall read, in print
size no less than one-half (112)inch in size, "gas vent directly
below. Keep clear of all obstructions".
4. Inspection: the state or local gas inspector of the side wall
horizontally vented gas fueled equipment shall not approve
the installation unless, upon inspection, the inspector observes
carbon monoxide detectors and signage installed in accordance
with the provisions of 248 CMR 5.08(2)(A)1 through 4.
5. Product-approved vent/air-intake: a product-approved vent ter-
minal must be used and, if applicable, a product-approved air
intake must be used. Installation shall be in strict compliance
with the rnanufacturer's instructions.
o
Installation instructions: a copy of all installation instructions
for all product approved side wall horizontally vented gas fueled
equipment, all venting instructions, all parts lists for venting
instructions, and/or all venting design instructions shall remain
with the appliance or equipment at the completion of the instal-
lation.
Boiler Sizing
Checkto be sure youhaveselected the boiler with the proper capac-
itybeforestarting the installation. TheI=B=RRatingofthe boiler
selectedshould begreater than or equal to the calculatedpeak heat-
ing load(heat loss)for thebuilding or area(s) served by the boiler
and associatedhot water heating systems.Seethe table"BOILER
RATINGSAND CAPACITIES"(page5 ofthis docurnent).
Heat losscalculationsshould be based onapproved industry meth-
ods.
Considerations For Boiler Location
Before selecting a location for the boiler, the following should be
considered. Each boiler considered.
•Suppliedwith the correct type of gas (natural gasor pro-
pane).
• Connected to a suitable cornbustion air intake piping sys-
tern to supply the correct amounts of fresh (outdoor) air
for cornbustion, refer to Combustion Air And Vent Pipe
section (near center of this manual) for details.
• Connected to a suitable venting systern to remove the
hazardous products of gas combustion, refer to Cornbus-
tion Air And Vent Pipe section (page 19 of this rnanual) for
details.
•Connected to asuitable hot water heating systern.
•Suppliedwith a suitableelectricalsupplyfor allboilerrno-
tors and controls.
• Connected to a properly located therrnostat or operating
control. (not included with boiler)
•Placedon levelsurface (rnustNOT be installedon carpet-
ing)
•Condensate drain line must bepitched down to floor drain
or external condensate purnp with reservoir at1A"per foot
(woodfrarne or blocksrnay beused to raise boiler).
Locating The Boiler
1. Selectalocationwhich is level,central to the piping systerns
served and as closeto the vent and air intaketerrninals as pos-
sible.
2. Accessibility clearances, if more stringent (i.e. larger clearances)
than required fire protection clearances, rnust be used for the
boiler installation. Accessibility clearances rnay be achieved
with the use of removable walls or partitions.
3. The boiler is approved for installation in closets and on com-
bustible floors. This boiler shall NOT be installed on carpeting.
4. The clearances shown in Table #2 indicate required clearances.
A rninimurn 1" clearance rnust be rnaintained between corn-
bustible construction and each of the left, top and back surfaces
of the boiler. A rninimum 8" clearance is required on the right
side, to allow roorn for the inlet air pipe. An 18" clearance rnust
be rnaintained at a side where passage is required to access an-
other side for cleaning or servicing, inspection or replacernent
of any parts that norrnally rnay require such attention. Allow at
least 24" at the front and left side and 8" at the top for servicing.
No clearances are required to venting or cornbustion air intake
piping.
5. Equipment shall be installed in a location which facilitates the
operation of venting and cornbustion air intake piping systems
as described in this rnanual.