Satec HEPS Hall Effect Power Supply Module User guide

  • Hello, I'm a chat assistant ready to help you with the SATEC HEPS Power Supply user manual. This document provides detailed information on installing, wiring and using the HEPS module, including connection to AC supply, Hall sensors wiring, and compatibility with SATEC PRO meters. I'm ready to answer your questions about this power supply.
  • What is the input voltage range for the HEPS module?
    What is the output voltage of the HEPS module?
    What SATEC devices are compatible with the HEPS module?
BG0641 REV.A1 ENGLISH HEPS Quickstart www.satec-global.com
HEPS Module Quick Start Manual
SATEC Hall Effect Power Supply (HEPS) Module for
Direct Current Applications
Figure 1: HEPS front plate and wiring terminals
Mounting, electrical connection and settings of the HEPS Module
shall be made in accordance with all applicable laws and/or
regulations and be performed by authorized personnel only.
HEPS QuickStart www.satec-global.com
ELECTRICAL INSTALLATION
Install the HEPS module on a DIN-rail, close to an appropriate AC power
supply. Wire L to phase and N to neutral current.
Each Hall Sensor must be connected to power supply via 3 wires, +, and 0.
When using the HEPS as power supply, wire + to +, to and 0 to 0.
Figure 2: Hall sensor wiring to PRO meter and to HEPS
HEPS QuickStart www.satec-global.com
HEPS MODULE CHARACTERISTICS
Power supply: 100-250V AC
Output: ±15V DC
TECHNICAL SPECIFICATIONS
Input Ratings
Voltage: 90-264V AC (50/60Hz)
Burden: 30 VA
Terminals: 2 X 7.5mm
Wire Size: 1.5-0.25mm2
Output
Voltage: 4 X ± 15V DC +)15 ;0 ;-15(
Power: 1.5W per each
Environmental
-40°C to 60°C / -40°F to 140°F
SATEC DEVICES
SATEC products supporting DC metering and use of HEPS:
EM235 (PRO)
PM335 (PRO)
PM130
PM135