55 000 041 – Ed. D SCOOP 3 5ASystem - User Manual 5
This document is the property of AAS and can not be duplicated without authorisation January 2006 Scoop 3 5AS manual - Ed.D.doc
2.2.6. Symmetric or asymmetric codec modes
The codec allows two communication modes:
Symmetric communication: in this mode, the encoder and decoder both use the same coding algorithm
with the same configuration (channel mode, etc.). In this case, the communication is strictly symmetric
full-duplex, with exactly the same coding configuration used in both directions (local to remote and
remote to local). This is usually required when using proprietary algorithms.
Asymmetric communication: this mode is used for applications requiring different coding configurations
in the two directions. The J52 protocol allows such mode. To give some examples, it is possible to
transmit MPEG Layer II in one direction and Layer III in the other one, or MPEG stereo in one direction
and MPEG mono in the other one, or MPEG in one direction and G722 in the other one, etc.
Specific product versions also allow asymmetric modes wherein one direction is G722 coded while the
other one is TDAC coded. Such mode is useful e.g. in order to get a low delay return path encoded in
G722 while the send path is encoded with higher quality but a higher delay.
2.3. Transmission interface
The transmission interface includes one to three S0 BRI interfaces (depending on equipment version),
each allowing transmission over one or two 64 kbit/s B channels. Thus, the total available bit rate ranges
from 64 to 256 kbit/s (1 to 4 B channels).
In the dual 7 kHz codec mode, the equipment is equivalent to two mono codecs. Each mono codec can
transmit, independently from the activity of the other codec, over a B channel from the first S0 interface.
Only the first S0 interface is used in this configuration.
The codec synchronises itself onto the ISDN network clock when a link is active.
2.4. Supervision and user interface
These functional modules fulfil the control and supervision of the equipment (configuration,
communication management, status monitoring), thanks to a keyboard, an alphanumeric display, LED
indicators, and a remote control asynchronous serial interface.
The equipment also features a “Loop control” function: call set up and release can be remote controlled
with current loops and relays, instead of using for this the keyboard and/or the remote control port.
In order to allow easy and quick programming of the codec for specific operational configurations, the
equipment features fifty configuration memories (or “profiles”). When recalling a profile, the codec is
directly reconfigured with parameters that were stored beforehand in this profile by the operator.
Besides configuring the equipment operating mode, this module monitors its status (detection of alarm
conditions). On detecting operation or transmission faults, the equipment switches on indicators and relay
contacts. Three alarm classes are defined:
• “Major internal” alarm ; corresponds to a major fault internal to the equipment ;
• “Major external” alarm ; corresponds to a major fault whose origin is deemed external to the
equipment (for example, transmission fault);
• “Minor” alarm.