INTRODUCTION StepOne
Specifications:
Accuracy: ±5mminwater
Repeatability: ±2mminwater
Extremeorientation: ±20°fromvertical
SpecificGravity: 0.8minimum
Contacttype: (1)SPST(reed)
Contactrating: 50VA@0.5A
Contactoutput: SelectableNOorNC
Temperaturerange: F:‐40°to176°/C:‐40°to80°
Pressure: 10psi(0.7bar)
Sensorrating: NEMA6(IP68)
Sensormaterial: LV510:Polypropylene
LV511:PolyvinylideneFluoride
Wirejacketmaterial: LV510:PVC
LV511:TFE
Wiretype: 2conductor
Wirelength: 2’(61cm)
Mountingthreads: 1/8"NPT
Classification: Generalpurpose,CE
Installation:
1. Switchesshouldbeinstalledrigidlysothefloator
floats are free to move as the liquid level
changes.
2. Switches should be mounted in a tank area free
of severe turbulence or protected from such
turbulence by appropriate and adequate slosh
shields.
3. Vertical switch stems should be vertical for best
results, but satisfactory operation is possible in
most liquids with the stem at up to a 20° angle
fromvertical.
4. Care should be taken that switches are always
operatedwithinelectricalratings.
5. Orientation for switches can be changed from
normally open to normally closed dry or vice
versabyremovingthefloatandreversingitinthe
stem.
Dimensions:
Components:
Part
Number
Body
Material
Cable
Material
Thread
LV510 PP PVC 1/8”NPT
LV511 PVDF TFE 1/8”NPT
SwitchRating:
ReedSwitchRating Max.ResistiveLoad
VA Volts Amps(AC) Amps(DC)
50
050 0.5 0.5
120 0.4 0.4
240 0.2 0.2
Top Wall Installation:Omega Engineering LV510 series switch may be installed through the top wall of a
tank.Becausethethreadofthesensorisverysmall(1/8”),findingstandardfittingsmaybedifficult.Inlieuof
standardfittings,onesuggestionistousealargerpipe,suchas½”.Placeacaporplugontheendofthepipe
andtapa1/8”threadintotheend.Securetheotherendofthepipetothetopofthetankortoaclamp.For
pipeslongerthan2’,besuretocleanlyextendthecable(splice)sothattheconnectionisnotexposedtothe
liquid.
3
ELECTRICAL StepTwo
SignalOutputs (NormallyOpenvs.NormallyClosed):TheLV510seriesfloatswitchshipsfromthe factoryin
the Normally Open (NO) configuration.The normal state is when the float is resting on the bottom of the
stem.AnorientationmarkwillappearonthetopofthefloatwhenitisintheNOconfiguration.Toswitchthe
LV510seriesfromNOtoNCconfiguration,flowthestepsbelow.
1. RemovetheCclipfromthestem.
2. Removethefloatandrotateit180°.
3. Returnthefloattothestemwithorientationmarknowonthebottom.
4. ReplacetheCclip.
NormallyOpenOperation: NormallyClosedOperation:
Orientation mark on the top of the float.In the dry
state, the float rests on the bottom of the stem and
thecircuitisopen.
Orientation mark on the bottom of the float.In the
dry state, the float rests on the bottom of the stem
andthecircuitisclosed.
As the switch becomes wet, the float becomes
buoyantandcircuitcloses.
As the switch becomes wet, the float becomes
buoyantandcircuitopens.
ContactProtection(ReedSwitch):Whencurrentisinterrupted,theinductanceoftheloadgeneratesahigh
frequency voltage, which appears across the switch contacts.If the voltage is large enough, it can cause
arcing.Arcingcancausethecontactstoweldtoeachotherresultinginunreliableswitchingperformance.Itis
essential to protect the cir
cuit, by suppressing the voltage to prevent arcing.This can be accomplished
throughtheuseofadiodeforDCcircuitsandaresistorcapacitornetworkforACcircuits.
DCContactProtection:
ACContactProtection:
4
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Omega LV-510 Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI