2
INTRODUCTION StepOne
Specifications:
Accuracy: ±5mminwater
Repeatability: ±2mminwater
Extremeorientation: ±20°fromvertical
SpecificGravity: 0.8minimum
Contacttype: (1)SPST(reed)
Contactrating: 50VA@0.5A
Contactoutput: SelectableNOorNC
Temperaturerange: F:‐40°to176°/C:‐40°to80°
Pressure: 10psi(0.7bar)
Sensorrating: NEMA6(IP68)
Sensormaterial: LV‐510:Polypropylene
LV‐511:PolyvinylideneFluoride
Wirejacketmaterial: LV‐510:PVC
LV‐511:TFE
Wiretype: 2‐conductor
Wirelength: 2’(61cm)
Mountingthreads: 1/8"NPT
Classification: Generalpurpose,CE
Installation:
1. Switchesshouldbeinstalledrigidlysothefloator
floats are free to move as the liquid level
changes.
2. Switches should be mounted in a tank area free
of severe turbulence or protected from such
turbulence by appropriate and adequate slosh
shields.
3. Vertical switch stems should be vertical for best
results, but satisfactory operation is possible in
most liquids with the stem at up to a 20° angle
fromvertical.
4. Care should be taken that switches are always
operatedwithinelectricalratings.
5. Orientation for switches can be changed from
normally open to normally closed dry or vice
versabyremovingthefloatandreversingitinthe
stem.
Dimensions:
Components:
Part
Number
Body
Material
Cable
Material
Thread
LV‐510 PP PVC 1/8”NPT
LV‐511 PVDF TFE 1/8”NPT
SwitchRating:
ReedSwitchRating Max.ResistiveLoad
VA Volts Amps(AC) Amps(DC)
50
0‐50 0.5 0.5
120 0.4 0.4
240 0.2 0.2
Top Wall Installation:Omega Engineering LV‐510 series switch may be installed through the top wall of a
tank.Becausethethreadofthesensorisverysmall(1/8”),findingstandardfittingsmaybedifficult.Inlieuof
standardfittings,onesuggestionistousealargerpipe,suchas½”.Placeacaporplugontheendofthepipe
andtapa1/8”threadintotheend.Securetheotherendofthepipetothetopofthetankortoaclamp.For
pipeslongerthan2’,besuretocleanlyextendthecable(splice)sothattheconnectionisnotexposedtothe
liquid.