GROHE 33 122 Instructions Manual

Type
Instructions Manual
D
.....1
I
.....5
N
.....9
GR
.....13
TR
.....17
BG
.....21
RO
.....25
GB
.....2
NL
.....6
FIN
.....10
CZ
.....14
SK
.....18
EST
.....22
CN
.....26
F
.....3
S
.....7
PL
.....11
H
.....15
SLO
.....19
LV
.....23
RUS .....27
E
.....4
DK
.....8
UAE
.....12
P
.....16
HR
.....20
LT
.....24
Design & Quality Engineering GROHE Germany
95.374.231/ÄM 214955/06.09
33 122 33 124
D
.....1
I
.....5
N
.....9
GR
.....13
TR
.....17
BG
.....21
RO
.....25
GB
.....2
NL
.....6
FIN
.....10
CZ
.....14
RUS
.....18
EST
.....22
CN
.....26
F
.....3
S
.....7
PL
.....11
H
.....15
SK
.....19
LV
.....23
RUS .....27
E
.....4
DK
.....8
UAE
.....12
P
.....16
HR
.....20
LT
.....24
I
Please pass these instructions on to the end user of the fitting.
S.v.p remettre cette instruction à l'utilisateur de la robinetterie!
Bitte diese Anleitung an den Benutzer der Armatur weitergeben!
33 122
33 124
II
2
GB
Application
Can be used in conjunction with: Pressurised storage
heaters, thermally and hydraulically controlled
instantaneous heaters. Operation with low-pressure
displacement water heaters is not possible.
Specifications
Flow pressure min. 0.5 bar / recommended 1 - 5 bar
Operating pressure max. 10 bar
Test pressure 16 bar
If static pressure is greater than 5 bar, fit pressure
reducer.
Avoid major pressure differences between hot and
cold water supply.
Flow rate at 3 bar flow pressure: approx. 8 l/min
Temperature
Hot water inlet max. 80 °C
Recommended (energy saving) 60 °C
Water connection hot - left
cold - right
Installation
Flush piping system prior and after installation of
fitting thoroughly (Consider EN 806)!
Installation and connection, see fold-out page III,
Fig. [1].
When assembling, the waste rod (A) has to be placed
into the body.
Fit pop-up waste set (28 915), see fold-out page II.
Seal plug-hole rim!
Open cold and hot-water supply and check con-
nections for leakage!
Check fitting for correct operation, see fold-out
page III, Fig. [2].
Temperature limiter
On delivery, the temperature limiter (fitted as standard)
is inoperative.
For commissioning see “Replacing the cartridge”
point 1 to 4.
Remove temperature limiter (B) and, depending on the
maximum temperature required, turn clockwise (to
increase temperature) or anticlockwise (to reduce
temperature) and refit, see Fig. [3] and [4].
Flow rate limiter
This fitting is fitted with a flow rate limiter, permitting an
infinitely individual variable reduction in the flow rate.
The highest possible flow rate is set by the factory
before despatch.
The use of flow rate limiters in combination with
hydraulic instantaneous water heaters is not
recommended.
For commissioning see “Replacing the cartridge” point
1 to 5, Figs. [3] and [5].
Maintenance
Inspect and clean all parts, replace as necessary and
grease with special grease.
Shut off the hot and cold water supply!
I. Replacing the cartridge, see Fig. [3].
1. Lever out plug (C).
2. Remove set screw (D) using a 3mm socket spanner
and pull off lever (E).
3. Release screw (F) and pull off collar (G).
4. Unscrew cap (H).
5. Pull off temperature limiter (B).
6. Remove screws (I) and detach complete
cartridge (J).
7. Change complete cartridge (J).
Assemble in reverse order.
Caution
In this process, note the relative positions of the
collar (G) and lever (E). The lugs (K) on the collar (G)
must engage the central recesses (L) in the lever (E),
see Fig. [6].
Make sure that the cartridge seals engage in the
grooves on the housing. Fit screws (I) and tighten
evenly and alternately.
II. Unscrew and clean flow straightener (13 960), see
fold-out page II.
Assemble in reverse order.
Replacement parts, see fold-out page II ( * = special
accessories).
Care
For directions on the care of this fitting, refer to the
accompanying Care Instructions.
III
1
13mm
1
9
m
m
A
2
3
3mm
B
C
D
E
F
G
H
I
I
J
L
KK
G
L
E
6
4
2
,
5
m
m
5
2
,
5
m
m
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

GROHE 33 122 Instructions Manual

Type
Instructions Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages