SH-8008F Setup Guide
Network Cables
Cables meeting the following specifications should be used:
- 10BASE-T : Equal to greater than Category 3 UTP, STP cable 100m or less
- 100BASE-TX : Equal to greater than Category 5 UTP, STP cable 100m or less
- There are straight/cross UTP and STP cables. Auto MDI/MDI-X feature allows connection of your Switching HUB
unit to a personal computer (LAN adapter) or another HUB unit and a bridges using either a straight or cross cable.
Inspection
Inspect the product periodically as follows to use it safely.
Neither dust nor alien substance is attached to the ventilation slits.
FCC PART15 Class A Notice
FCC WARNING
Changes or modifications not expressly approved by the party responsible for compliance could void the user's
authority to operate the equipment.
NOTE:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
EN55032 Class A Notice
Warning: Operation of this equipment in a residential environment could cause radio interference.
The caution when you register UL for your system with this product
- Use POA201-10-2 of the optional products.
Specifications
Specifications
–
10Mbps/100Mbps (auto-negotiation)
All ports: Full/Half duplex (auto-negotiation)
Full Duplex : IEEE802.3x compliant flow control
Half Duplex : Back pressure
Number of effective ports
8,130pps (at 10Mbps) / 148,800pps (at 100Mbps)
8,130pps (at 10Mbps) / 148,800pps (at 100Mbps)
POWER (Green), LINK/ACT (Greed), SPEED 10/100M (Orange)
Reverse polarity protection
Power supply connector equipped with FG pin
When inputting 12V : 0.12A, When inputting 24V : 0.06A
40(W) x 60(D) x 90(H) (exclusive of protrusions)
Module installation method
Attachment of a 35mm DIN rail.
*1 This produ ct can operate with a single power supply. Also, you can add redundancy to the power supply by addin g
a second power supply input.
Installation Environment Requirements
10 - 90%RH (No condensation)
Line-Noise
resistance
AC line/2kV, Signal line/1kV (JIS C61000-4-4Level 3, EN61000-4-4Level 3)
Static electricity
resistance
Contact discharge/4kV (JIS C61000-4-2Level 2, EN61000-4-2Level 2)
Atmospheric discharge/8kV (JIS C61000-4-2Level 3, EN61000-4-2Level 3)
Vibration
resistance
Sweep
resistance
10 - 57Hz/semi-amplitude 0.15mm,57 - 150Hz/2.0G
40minutes each in X, Y, and Z directions
(JIS C60068-2-6-compliant, IEC60068-2-6-compliant)
15G, half-sine shock for 11ms in X, Y, and Z directions
(JIS C60068-2-27-compliant, IEC60068-2-27-compliant)
Class D grounding (previous class 3 grounding)
VCCI Class A, FCC Class A, UL,
CE Marking (EMC Directive Class A, RoHS Directive)
Physical Dimensions
Handling Precautions
- Do not use the product where it is exposed to flammable or corrosive gas. Doing so may result in an explosion, fire, electric shock, or failure.
- Do not allow this device to come into co ntac t with fo reign subs tances (metal particles, flammable substanc es, liquids, etc.) This can cause fire or electrical shock.
- Do not place this device in an unstable location or use incomplete mountings. This may cause the d evic e to fall.
- Be sure to connect the product to the stipulated power supply voltage. Connecting to a different voltage might cause a fire or electrical shock.
- This product is not intended for use in aerospace, space, nuclear power, medical equipment, or other applications that require a very high level of reliability. Do not use
the prod uct in s uch applic atio ns.
- If us ing this product in applications where s afety is critic al suc h as in railways, auto mo tive, or d isaster prevention or sec urity systems, please contact your retailer.
- The link speed value (e.g., 100Mbps) of the transmission rate used in the Manual (this document) is the theoretical maximum value of the wired LAN standard and do
not indica te the ac tual data transmiss io n speed.
- The frame loss could occur depending on the connection destination or installed environment.
- This product contains precision electronic elements and must not be used in locations subject to physical shock or strong vibration. Otherwise, the board may
malfunction, overheat, or cause a failure.
- Avoid transporting this products state to shock or vibration that exceeds range of specification.
- Do not use or store the equipment in a hot or cold place, or in a place that is subject to severe temperature changes. They may cause the malfunction, heat generation,
fault, or damage.
- Do not us e or sto re the eq uipment in a p lace sub ject to direct s unlight or near a heating device, such as a stove. And do not use or store the product near equipment
generating a strong magnetic field or radio waves. They may cause the malfunctio n, heat generation, fault, or damage.
- Do not use or store this product in the presence of chemicals.
- Use the product in the specified operating condition (temperature, humidity, vibration and shock)
- Please adjust the air current to prevent the reject heat from the product staying around the product.
- Do not use this product in extremely humid or dusty locations. It is extremely dangerous to use this product with its interior penetrated by water o r any other fluid o r
conductive dust. If this product must be used in such an environment, install it on a dust-proo f co ntrol panel, for example.
- If you noticing abnormal odor or overheat, please unplug the power cord immediately.
- When you find faults or abnormalities (bad smell or excessive heat), pull the power cord off, then contact the shop you bought the product or your retailer.
- When using one power supply input, do not touch the unconnected power supply connector. Doing so may result in electric shock or failure.
- When placing importance on line-nois e resistanc e, use shie lded c ables to connect to p eriphery d evic es.
- The product could be very hot in the operation. Please do not touch by hands or body. It may cause burns.
- To avoid electric shock, please do not touch the system with a wet hand.
- Do not open the unit casing. CONTEC will disclaim any responsibility for equipment whose casing has been opened.
- Do not modify the product. CONTEC will bear no responsibility for any problems, etc., resulting from modifying this product.
- To clean this product, gently wipe it with a soft cloth soaked with water or a neutral detergent. Do not use benzene, a thinner, or other volatile solvents as they can cause
the coating to discolor or peel off.
- When connecting cables, first check the shapes of connectors (such as LAN connectors), and then insert them in the correct orientation. After they are connected, do not
put too much load on the connected part. Doing so may result in poor contact or damage to this product and the connected part.
- Do not touch terminals of the product with your hands in operation. Otherwise, this product may malfunction, overheat, or cause a failure.
- The specification of this product is subject to change without notice for enhancement and quality improvement. Even when using this product continuously, be sure to
read the manual of CONTEC’s website and understand the contents.
- If you move or transfer the product, make sure to attach the Setup Guide (this document).
- To use the product in places affected by overcurrent or overvoltage (lightning surge, etc.), select appropriate surge protection device (SPD) for all entry paths (power line,
LAN, gro und, etc.). For selection/introduct ion/installatio n of SPD, p lease consult a specialis t.
- Regardless of the foregoing statements, CONTEC is not liable for any damages whatsoever (including damages for loss of business profits) arising out of the use or
inability to use this CONTEC product or the information contained herein.
- When disposing this product, please comply with the municipal regulations and ordinances.
LTD.
-9-31, Himes ato , Ni shi yodogawa-ku, Osaka 555-0025, Japan
Japanese http://www.contec.co.jp/ English http://www.contec.com/
Chinese
http://www.contec.com.cn/
No part of this document may be copied or reproduced in any form by any means without prior written consent of CONTEC CO., LTD.
12-24VDC
14
18
φ
4
60
5
90
40
18
Open
[mm]