Lightolier IS:26049 User manual

  • Hello! I am an AI chatbot trained to assist you with the Lightolier IS:26049 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
FALL RIVER, MASSACHUSETTS 02720
MONTREAL, QUEBEC, CANADA
© 1997
INSTRUCTION SHEET NO.
0197 Page 1 of 1
READ AND UNDERSTAND ALL TRACK, CONNECTOR, FEED-IN-KITS, AND ACCESSORY
INSTRUCTION SHEETS BEFORE INSTALLING ANY PROSPEC™ TRACK ITEM.
This fixture is intended for installation in accordance with the National Electrical Code and local or Federal
code specifications. To assure full compliance with codes and regulations, check with your local electrical
inspector before installation. To prevent electric shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
IS:26049
Installation Instructions for Invisible Coupler. For use with ProSpec
Track System Only.
Track Unit
Copper Wire
Contact Blade
Fig. 1
Track Unit
Fig. 2
Invisible
Coupler
Align Arrows
Fig. 4
Secured Screws
Track Unit
Track Unit
Bottom Cover
Secure Screws if accessible
after Track is mounted.
Spline
The Mini Coupler is used to join two pieced of track together
mechanically and electrically. Power cannot be feed into the Mini
Coupler.
Caution:
Turn off power at fuse box before installing the invisible
coupler and track.
Do not attempt to feed power to the invisible coupler.
INSTALLING CONNECTOR INTO TRACK SECTION
1. Remove Dead End Cover if necessary by pulling it out of Track
(save Dead End Cover). Fig 1.
2. Push Coupler into track until the arrows line up with the track
edge. Ensure that the contact blades are aligning with the copper
wires in the track during assembly. (Fig 2 & Fig 3)
3. Tighten the Locking Screw, (Fig 3)
4. Insert metal spline into the track approximately half the distance
of the metal spline length (Fig 5). Note orientation of spline in
channel.
5. Insert the assembled track and coupler into the mating track.
Ensure that the contact blades are aligning with the copper wires
in the track (Fig 2). Push together until there are no gaps between
the track unit sections. (Fig 4)
6. Check arrows on bottom of coupler. If arrows are not in line with
the edge of the track, realign the coupler until the arrows are in
line with the track edges.
7. Tighten locking screws. Note: if there is access from above the
track after it is mounted (ie. track stem installation) secure the
spline to the mating track using the (2) additional screws. Do not
use the additional two screws if there is no access. The track will
have to be removed from the structure to remove the invisible
coupler.
8. Snap the bottom cover into the track sections.
Remove Dead End
Invisible
Coupler
Track Unit
Locking Screw
Fig. 3
Fig. 5
Tighten Screws
Spline
Track Unit
/