PerfectAire 3PASC10000 User manual

  • Hello! I've reviewed the user manual for the perfect aire 3PASC10000 Window Air Conditioner. This document covers everything from initial setup to long-term care, including safety precautions, installation tips for various window types, and useful functions like the Follow Me feature and Sleep mode. I am ready to help you with any questions you might have about your new unit.
  • How often should I clean the air filter?
    What should I do if an error code appears on the display?
    What does the FOLLOW ME feature do?
    What is the purpose of the exhaust control?
Perfect Aire, LLC
5151 Belt Line Rd.
Suite 878
Dallas, TX 75254
Distributed by:
844-4PA-AIRE | 844-472-2473
www.perfectaire.us
WINDOW
AIR CONDITIONER
FOR MODEL:
3PASC10000
Before using your air conditioner, please
read this manual carefully and keep it for
future reference, along with your receipt.
Speciļ¬cation and performance data is subject to change without notice.
Printed in China
PA/User_3PASC10000/10162017
USER MANUAL
For your own records, please attach a copy of your sales receipt to this manual and complete the following:
Model Number: _____________________________________ Serial Number: _______________________________________
Purchase Date: ____________________________________ Store Purchased: _____________________________________
Installation Date: ___________________________________ Installation Co.: _______________________________________
Installer Name: _____________________________________ Installer Phone No.: ___________________________________
CONSUMER PRODUCT INFORMATION
SAFETY PRECAUTIONS ...................................................................1
IMPORTANT SAFETY INSTRUCTIONS ...........................................3
INSTALLATION INSTRUCTIONS .....................................................4
INSTALLING UNIT IN A SLIDING WINDOW .......................6
INSTALLING UNIT IN A CASEMENT WINDOW ..................9
NORMAL SOUNDS ...........................................................................12
AIR CONDITIONER FEATURES .......................................................12
CARE AND CLEANING ....................................................................15
TROUBLESHOOTING ....................................................................... 16
CONTENTS
This manual provides the information needed for proper use and maintenance
of this air conditioner. Basic preventative care can help extend the life of
this unit. The ā€œTroubleshootingā€ section in this manual contains a chart with
solutions to the most common problems. Referring to this section may save
time and prevent the need for a service call in the event of a problem.
CAUTIONS
ā—ī€ƒ Contactī€ƒanī€ƒauthorizedī€ƒserviceī€ƒtechnicianī€ƒforī€ƒrepairī€ƒorī€ƒmaintenanceī€ƒofī€ƒthisī€ƒunit.
ā—ī€ƒ Contactī€ƒanī€ƒinstallerī€ƒforī€ƒinstallationī€ƒofī€ƒthisī€ƒunitī€ƒifī€ƒnecessary.
ā—ī€ƒ Theī€ƒairī€ƒconditionerī€ƒisī€ƒnotī€ƒintendedī€ƒforī€ƒuseī€ƒbyī€ƒyoungī€ƒchildrenī€ƒwithoutī€ƒadultī€ƒsupervision.ī€ƒYoungī€ƒchildrenī€ƒshouldī€ƒbeī€ƒ
supervised to ensure that they do not play with the air conditioner.
ā—ī€ƒ Disabledī€ƒpersonsī€ƒmayī€ƒrequireī€ƒassistanceī€ƒwithī€ƒsetī€ƒup.
ā—ī€ƒ Ifī€ƒtheī€ƒpowerī€ƒcordī€ƒisī€ƒtoī€ƒbeī€ƒreplaced,ī€ƒreplacementī€ƒworkī€ƒshouldī€ƒbeī€ƒperformedī€ƒbyī€ƒauthorizedī€ƒpersonnelī€ƒonly.
ā—ī€ƒ Installationī€ƒandī€ƒrepairī€ƒworkī€ƒmustī€ƒbeī€ƒperformedī€ƒinī€ƒaccordanceī€ƒwithī€ƒtheī€ƒnationalī€ƒwiringī€ƒstandardsī€ƒbyī€ƒauthorizedī€ƒ
personnel only.
ā—ī€ƒ Doī€ƒnotī€ƒoperateī€ƒyourī€ƒairī€ƒconditionerī€ƒinī€ƒaī€ƒwetī€ƒroomī€ƒsuchī€ƒasī€ƒaī€ƒbathroomī€ƒorī€ƒlaundryī€ƒroom.
NOTE:ī€ƒAllī€ƒtheī€ƒillustrationsī€ƒinī€ƒthisī€ƒmanualī€ƒareī€ƒforī€ƒexplanationī€ƒpurposesī€ƒonly.ī€ƒUnitī€ƒpurchasedī€ƒmayī€ƒbeī€ƒslightlyī€ƒdiī‰ˆerent.
Theī€ƒdesignī€ƒandī€ƒspeciīƒ„cationsī€ƒareī€ƒsubjectī€ƒtoī€ƒchangeī€ƒwithoutī€ƒpriorī€ƒnoticeī€ƒforī€ƒproductī€ƒimprovement.ī€ƒContactī€ƒConsumerī€ƒ
Services at 844-472-2473 for details.
1
WARNINGS
ļƒ¼Plug in power cord properly. Failureī€ƒtoī€ƒdoī€ƒsoī€ƒmayī€ƒcauseī€ƒelectricī€ƒshockī€ƒorī€ƒīƒ„reī€ƒdueī€ƒtoī€ƒ
excess heat generation.
ļ—DO NOT operate or stop the unit by inserting or pull-
ing out the power plug directly from the wall.
Doingī€ƒsoī€ƒmayī€ƒcauseī€ƒelectricī€ƒshockī€ƒorī€ƒīƒ„reī€ƒdueī€ƒtoī€ƒ
heat generation.
ļ—
DO NOT use a damaged power cord. Doingī€ƒsoī€ƒmayī€ƒcauseī€ƒelectricī€ƒshockī€ƒorī€ƒīƒ„re.ī€ƒIfī€ƒtheī€ƒpowerī€ƒ
cord is damaged, it must be replaced by the manufactur-
erī€ƒorī€ƒanī€ƒauthorizedī€ƒserviceī€ƒcenterī€ƒorī€ƒaī€ƒsimilarlyī€ƒqualiīƒ„edī€ƒ
personī€ƒinī€ƒorderī€ƒtoī€ƒavoidī€ƒaī€ƒhazard.
ļ—DO NOT modify power cord length or share the
outlet with other appliances.
Doingī€ƒsoī€ƒmayī€ƒcauseī€ƒelectricī€ƒshockī€ƒorī€ƒīƒ„reī€ƒdueī€ƒtoī€ƒ
heat generation.
ļ—DO NOT operate with wet hands or in
damp environment.
Doingī€ƒsoī€ƒmayī€ƒcauseī€ƒelectricī€ƒshock.
ļ—DO NOTī€ƒdirectī€ƒairīƒ…owī€ƒdirectlyī€ƒatī€ƒroomī€ƒoccupants. This could cause health issues.
ļƒ¼Alwaysī€ƒensureī€ƒeī‰ˆectiveī€ƒgrounding. Incorrectī€ƒgroundingī€ƒmayī€ƒcauseī€ƒelectricī€ƒshock.
ļ—DO NOT allow water to run into electric parts. Doingī€ƒsoī€ƒmayī€ƒcauseī€ƒfailureī€ƒofī€ƒmachineī€ƒorī€ƒelectricī€ƒshock.
ļƒ¼Alwaysī€ƒinstallī€ƒcircuitī€ƒbreakerī€ƒandī€ƒaī€ƒdedicatedī€ƒ
power circuit.
Incorrectī€ƒinstallationī€ƒmayī€ƒcauseī€ƒīƒ„reī€ƒandī€ƒelectricī€ƒshock.
ļƒ¼Always unplug the unit if strange sounds, smell or
smokeī€ƒcomesī€ƒfromī€ƒtheī€ƒunit.
Failureī€ƒtoī€ƒdoī€ƒsoī€ƒmayī€ƒcauseī€ƒīƒ„reī€ƒandī€ƒelectricī€ƒshock.
ļ—DO NOTī€ƒuseī€ƒtheī€ƒsocketī€ƒifī€ƒitī€ƒisī€ƒlooseī€ƒorī€ƒdamaged. Doingī€ƒsoī€ƒmayī€ƒcauseī€ƒīƒ„reī€ƒandī€ƒelectricī€ƒshock.
ļ—DO NOT open the unit during operation. Doingī€ƒsoī€ƒmayī€ƒcauseī€ƒelectricī€ƒshock.
ļ—DO NOTī€ƒuseī€ƒīƒ„rearmsī€ƒnearī€ƒunit. Doingī€ƒsoī€ƒmayī€ƒcauseī€ƒīƒ„re.
ļ—DO NOT use the power cord close to
heating appliances.
Doingī€ƒsoī€ƒmayī€ƒcauseī€ƒīƒ„reī€ƒandī€ƒelectricī€ƒshock.
ļ—DO NOT disassemble, modify, or drill holes into
the air conditioner.
Doingī€ƒsoī€ƒmayī€ƒcauseī€ƒfailureī€ƒandī€ƒelectricī€ƒshockī€ƒandī€ƒvoidī€ƒ
the manufacturerā€™s warranty.
ļƒ¼Ventilate room before operating air conditioner if
thereī€ƒisī€ƒaī€ƒgasī€ƒleakī€ƒfromī€ƒanotherī€ƒapplianceī€ƒsuchī€ƒasī€ƒ
a stove.
Failureī€ƒtoī€ƒdoī€ƒsoī€ƒmayī€ƒcauseī€ƒexplosion,ī€ƒīƒ„reī€ƒandī€ƒburns.
ļ—DO NOT
ī€ƒuseī€ƒtheī€ƒpowerī€ƒcordī€ƒnearī€ƒīƒ…ammableī€ƒgasī€ƒorī€ƒ
combustibles,ī€ƒsuchī€ƒasī€ƒgasoline,ī€ƒbenzene,ī€ƒthinner,ī€ƒetc.
Doingī€ƒsoī€ƒmayī€ƒcauseī€ƒanī€ƒexplosionī€ƒorī€ƒīƒ„re.
READ SAFETY PRECAUTIONS BEFORE INSTALLATION
Toī€ƒpreventī€ƒinjuryī€ƒtoī€ƒtheī€ƒuserī€ƒorī€ƒotherī€ƒpeopleī€ƒandī€ƒpropertyī€ƒdamage,ī€ƒtheī€ƒfollowingī€ƒinstructionsī€ƒmustī€ƒbeī€ƒfollowed.ī€ƒ
Incorrectī€ƒoperationī€ƒdueī€ƒtoī€ƒignoringī€ƒofī€ƒinstructionsī€ƒmayī€ƒcauseī€ƒharmī€ƒorī€ƒdamage.ī€ƒTheī€ƒseriousnessī€ƒisī€ƒclassiīƒ„edī€ƒbyī€ƒtheī€ƒ
following indications.
THIS SYMBOL INDICATES THAT IGNORING INSTRUCTIONS MAY CAUSE
DEATH OR SERIOUS INJURY.
NEVER DO THIS.OTHER SYMBOLS: ALWAYS DO THIS.
THIS SYMBOL INDICATES THAT IGNORING INSTRUCTIONS MAY CAUSE
MODERATE INJURY TO YOUR PERSON, OR DAMAGE TO YOUR UNIT OR
OTHER PROPERTY.
SAFETY PRECAUTIONS
2
CAUTIONS
ļ—Whenī€ƒremovingī€ƒairī€ƒīƒ„lter,ī€ƒDO NOT touch metal parts of
the unit.
Doingī€ƒsoī€ƒmayī€ƒcauseī€ƒanī€ƒinjury.
ļ—DO NOT clean with water. Water may enter the unit and degrade the insulation,
causingī€ƒanī€ƒelectricī€ƒshock.
ļƒ¼Ensure proper ventilation, especially in rooms with a
stove or other appliances.
Failure to do so may result in an oxygen shortage.
ļƒ¼Unitī€ƒandī€ƒcircuitī€ƒbreaker/fuseī€ƒmustī€ƒbeī€ƒswitchedī€ƒOFFī€ƒ
when cleaning.
Cleaningī€ƒunitī€ƒwhenī€ƒpowerī€ƒisī€ƒONī€ƒmayī€ƒcauseī€ƒīƒ„reī€ƒandī€ƒ
electricī€ƒshockī€ƒandī€ƒmayī€ƒcauseī€ƒanī€ƒinjury.
ļ—DO NOT put a pet or house plant where it will be ex-
posedī€ƒtoī€ƒdirectī€ƒairī€ƒīƒ…ow.
Thisī€ƒcouldī€ƒinjureī€ƒtheī€ƒpetī€ƒorī€ƒplant.
ļƒ¼Use ONLY as intended. This unit is NOT intended to preserve precision devic-
es,ī€ƒfood,ī€ƒpets,ī€ƒplants,ī€ƒandī€ƒartī€ƒobjects.ī€ƒItī€ƒmayī€ƒcauseī€ƒ
deteriorationī€ƒofī€ƒquality,ī€ƒetc.
ļƒ¼Stop operation and close the window in severe
storms or hurricanes.
Operationī€ƒwithī€ƒwindowsī€ƒopenī€ƒmayī€ƒcauseī€ƒmoistureī€ƒtoī€ƒ
enter the room.
ļƒ¼Hold the plug by the head of the power plug when
takingī€ƒitī€ƒout.
Failureī€ƒtoī€ƒdoī€ƒsoī€ƒmayī€ƒcauseī€ƒelectricī€ƒshockī€ƒ
and damage.
ļƒ¼If unit will not be used for a long period of time,
unplug or turn OFF main power switch.
Leavingī€ƒpowerī€ƒonī€ƒmayī€ƒcauseī€ƒunitī€ƒfailureī€ƒorī€ƒīƒ„re.
ļ—DO NOT place obstacles around air-inlets or inside of
air-outlet.
Obstaclesī€ƒmayī€ƒcauseī€ƒapplianceī€ƒfailureī€ƒorī€ƒaccident.
ļƒ¼Periodicallyī€ƒcheckī€ƒinstallationī€ƒbracketī€ƒforī€ƒdamage. Prolonged exposure to outdoor elements may cause
damageī€ƒtoī€ƒinstallationī€ƒbracket,ī€ƒcausingī€ƒunitī€ƒtoī€ƒfall.
ļƒ¼Alwaysī€ƒinsertī€ƒīƒ„lter(s)ī€ƒsecurely.ī€ƒCleanī€ƒīƒ„lter(s)ī€ƒAT LEAST
onceī€ƒeveryī€ƒtwoī€ƒweeks.
Operationī€ƒwithoutī€ƒsecurelyī€ƒinstalledī€ƒīƒ„ltersī€ƒmayī€ƒcauseī€ƒ
failure.ī€ƒAī€ƒdirtyī€ƒīƒ„lterī€ƒcanī€ƒcauseī€ƒtheī€ƒunitī€ƒtoī€ƒnotī€ƒrunī€ƒ
eī‰‰ciently.
ļƒ¼Use only a soft cloth to clean the unit. Cleaners or detergents may change the color or
scratch the surface of the unit.
ļƒ¼Useī€ƒcautionī€ƒwhenī€ƒunpackingī€ƒandī€ƒinstalling. Sharpī€ƒedgesī€ƒcouldī€ƒcauseī€ƒinjury.
ļ—NEVERī€ƒdrinkī€ƒwaterī€ƒdrainedī€ƒfromī€ƒairī€ƒconditioner. Water from unit contains contaminants and could
cause illness.
ļ—DO NOTī€ƒplaceī€ƒheavyī€ƒobjectsī€ƒonī€ƒtheī€ƒpowerī€ƒcordī€ƒandī€ƒ
always ensure that the cord is not compressed.
Thereī€ƒisī€ƒdangerī€ƒofī€ƒīƒ„reī€ƒorī€ƒelectricī€ƒshock.
ļƒ¼
If water enters the unitā€™s electrical components, turn
theī€ƒunitī€ƒoī‰ˆī€ƒatī€ƒtheī€ƒpowerī€ƒoutletī€ƒandī€ƒswitchī€ƒoī‰ˆī€ƒtheī€ƒcir-
cuitī€ƒbreaker.ī€ƒIsolateī€ƒsupplyī€ƒbyī€ƒtakingī€ƒtheī€ƒpower-plugī€ƒ
outī€ƒandī€ƒcontactī€ƒaī€ƒqualiīƒ„edī€ƒservicedī€ƒtechnician.
Thereī€ƒisī€ƒdangerī€ƒofī€ƒelectricī€ƒshock.
3
IMPORTANT SAFETY INSTRUCTIONS
NOTE:
The power supply cord with this air
conditioner contains a current detection
deviceī€ƒdesignedī€ƒtoī€ƒreduceī€ƒtheī€ƒriskī€ƒ
ofī€ƒīƒ„re.ī€ƒPleaseī€ƒreferī€ƒtoī€ƒtheī€ƒsectionī€ƒ
ā€œOperationī€ƒofī€ƒCurrentī€ƒDeviceā€ī€ƒ(below)ī€ƒ
for details. In the event that the power
supply cord is damaged, it cannot be
repaired. It must be replaced by an
authorizedī€ƒrepairī€ƒtechnicianī€ƒwithī€ƒaī€ƒcordī€ƒ
from the Product Manufacturer.
WARNING
Avoidī€ƒīƒ„reī€ƒhazardsī€ƒorī€ƒelectricī€ƒshock.ī€ƒ
DO NOT use an extension cord or an
adapter plug. DO NOT remove any prong
from the power cord.
OPERATION OF
CURRENT DEVICE:
The power supply cord contains a
current device that senses damage
to the power cord. To test your power
supply cord, do the following:
1. Plug in the air conditioner.
2. The power supply cord will have
TWOī€ƒbuttonsī€ƒonī€ƒtheī€ƒplugī€ƒhead.ī€ƒPressī€ƒ
theī€ƒTESTī€ƒbutton.ī€ƒYouī€ƒwillī€ƒnoticeī€ƒaī€ƒ
clickī€ƒasī€ƒtheī€ƒRESETī€ƒbuttonī€ƒpopsī€ƒout.
3. Press the RESET button. Again,
youī€ƒwillī€ƒnoticeī€ƒaī€ƒclickī€ƒasī€ƒtheī€ƒ
button engages.
4. The power supply cord is now
supplyingī€ƒelectricityī€ƒtoī€ƒtheī€ƒunit.ī€ƒ(Onī€ƒ
some products this is also indicated
byī€ƒaī€ƒlightī€ƒonī€ƒtheī€ƒplugī€ƒhead.)
WARNING
FORī€ƒYOURī€ƒSAFETY:ī€ƒDoī€ƒnotī€ƒstoreī€ƒorī€ƒuseī€ƒgasolineī€ƒorī€ƒotherī€ƒīƒ…ammableī€ƒ
vaporsī€ƒandī€ƒliquidsī€ƒinī€ƒtheī€ƒvicinityī€ƒofī€ƒthisī€ƒorī€ƒanyī€ƒotherī€ƒappliances.
WARNING - PREVENT ACCIDENTS
Toī€ƒreduceī€ƒtheī€ƒriskī€ƒofī€ƒīƒ„re,ī€ƒelectricalī€ƒshock,ī€ƒorī€ƒinjuryī€ƒtoī€ƒpersonsī€ƒwhenī€ƒusingī€ƒ
your air conditioner, follow basic precautions, including the following:
ā—ī€ƒ Beī€ƒsureī€ƒtheī€ƒelectricalī€ƒserviceī€ƒisī€ƒadequateī€ƒforī€ƒtheī€ƒmodelī€ƒyouī€ƒhaveī€ƒ
chosen. This information can be found on the serial plate, which is
located on the side of the cabinet and behind the grille.
ā—ī€ƒ Ifī€ƒtheī€ƒairī€ƒconditionerī€ƒisī€ƒtoī€ƒbeī€ƒinstalledī€ƒinī€ƒaī€ƒwindow,ī€ƒyouī€ƒwillī€ƒprobablyī€ƒ
wantī€ƒtoī€ƒcleanī€ƒbothī€ƒsidesī€ƒofī€ƒtheī€ƒglassī€ƒīƒ„rst.ī€ƒIfī€ƒtheī€ƒwindowī€ƒisī€ƒaī€ƒtriple-
trackī€ƒtypeī€ƒwithī€ƒaī€ƒscreenī€ƒpanelī€ƒincluded,ī€ƒremoveī€ƒtheī€ƒscreenī€ƒcompletelyī€ƒ
before installation.
ā—ī€ƒ Beī€ƒsureī€ƒtheī€ƒairī€ƒconditionerī€ƒhasī€ƒbeenī€ƒsecurelyī€ƒandī€ƒcorrectlyī€ƒinstalledī€ƒ
according to the installation instructions in this manual.
ā—ī€ƒ
Save this manual for possible future use in removing or installing this unit.
ā—ī€ƒ Whenī€ƒhandlingī€ƒtheī€ƒairī€ƒconditioner,ī€ƒbeī€ƒcarefulī€ƒtoī€ƒavoidī€ƒcutsī€ƒfromī€ƒsharpī€ƒ
metalī€ƒīƒ„nsī€ƒonī€ƒfrontī€ƒandī€ƒrearī€ƒcoils.
WARNING - ELECTRICAL INFORMATION
The complete electrical rating of your new room air conditioner is stated
onī€ƒtheī€ƒserialī€ƒplate.ī€ƒReferī€ƒtoī€ƒtheī€ƒratingī€ƒwhenī€ƒcheckingī€ƒtheī€ƒelectricalī€ƒ
requirements.
ā—ī€ƒ Beī€ƒsureī€ƒtheī€ƒairī€ƒconditionerī€ƒisī€ƒproperlyī€ƒgrounded.ī€ƒToī€ƒminimizeī€ƒshockī€ƒ
andī€ƒīƒ„reī€ƒhazards,ī€ƒproperī€ƒgroundingī€ƒisī€ƒimportant.ī€ƒTheī€ƒpowerī€ƒcordī€ƒisī€ƒ
equippedī€ƒwithī€ƒaī€ƒthree-prongī€ƒgroundingī€ƒplugī€ƒforī€ƒprotectionī€ƒagainstī€ƒ
shockī€ƒhazards.ī€ƒ
ā—ī€ƒ Yourī€ƒairī€ƒconditionerī€ƒmustī€ƒbeī€ƒusedī€ƒinī€ƒaī€ƒproperlyī€ƒgroundedī€ƒwallī€ƒ
receptacle.ī€ƒIfī€ƒtheī€ƒwallī€ƒreceptacleī€ƒyouī€ƒintendī€ƒtoī€ƒuseī€ƒisī€ƒnotī€ƒadequatelyī€ƒ
groundedī€ƒorī€ƒprotectedī€ƒbyī€ƒaī€ƒtimeī€ƒdelayī€ƒfuseī€ƒorī€ƒcircuitī€ƒbreaker,ī€ƒhaveī€ƒaī€ƒ
qualiīƒ„edī€ƒelectricianī€ƒinstallī€ƒtheī€ƒproperī€ƒreceptacle.
ā—ī€ƒ Ensureī€ƒtheī€ƒreceptacleī€ƒisī€ƒaccessibleī€ƒafterī€ƒtheī€ƒunitī€ƒinstallation.
ā—ī€ƒ DO NOT run air conditioner without side protective cover in place. This
could result in mechanical damage within the air conditioner.
ā—ī€ƒ DO NOT use an extension cord or an adapter plug.
NOTE:
DO NOTī€ƒuseī€ƒtheī€ƒplugī€ƒtoī€ƒturnī€ƒtheī€ƒunitī€ƒonī€ƒorī€ƒoī‰ˆ.
ā—ī€ƒ Alwaysī€ƒmakeī€ƒsureī€ƒtheī€ƒRESETī€ƒbuttonī€ƒisī€ƒpushedī€ƒinī€ƒforī€ƒcorrectī€ƒoperation.
ā—ī€ƒ Theī€ƒpowerī€ƒsupplyī€ƒmustī€ƒbeī€ƒreplacedī€ƒifī€ƒitī€ƒfailsī€ƒresetī€ƒwhenī€ƒeitherī€ƒtheī€ƒTESTī€ƒ
button is pushed or it cannot be reset.
ā—ī€ƒ Ifī€ƒpowerī€ƒsupplyī€ƒcordī€ƒisī€ƒdamaged,ī€ƒitī€ƒcannotī€ƒbeī€ƒrepaired.ī€ƒPleaseī€ƒcallī€ƒ
Consumer Services at 844-472-2473 to assist with replacement.
NOTE: This air conditioner is designed to be operated under the
following conditions:
Cooling
Operation
Outdoor Temp: 64ī€ƒā€“ī€ƒ109Ā°F/18ī€ƒā€“ī€ƒ43Ā°C
(64ī€ƒā€“ī€ƒ125Ā°F/18ī€ƒā€“ī€ƒ52Ā°Cī€ƒforī€ƒspecialī€ƒtropicalī€ƒmodels)
Indoor Temp: 62ī€ƒā€“ī€ƒ90Ā°F/17ī€ƒā€“ī€ƒ32Ā°C
Performance may be reduced outside of these operating temperatures.
Grounding Type
Wall Receptacle
Do not, under any
circumstances, cut,
remove, or bypass the
ground prong.
Power supply cord
with 3-prong grounding
plug and current
detection device
4
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT- Save these instructions.
IMPORTANT-ī€ƒObserveī€ƒallī€ƒgoverningī€ƒcodesī€ƒ
and ordinances.
Note to Installer- Be sure to leave these instructions
with the Consumer.
Note to Consumer- Keep these instructions for
future reference.
Skill level-ī€ƒInstallationī€ƒofī€ƒthisī€ƒapplianceī€ƒrequiresī€ƒ
basicī€ƒmechanicalī€ƒskills.
Completion time- Approximately 1 hour.
We recommend that two people install this product.
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not
covered under the Warranty.
Youī€ƒMUSTī€ƒuseī€ƒallī€ƒsuppliedī€ƒpartsī€ƒandī€ƒuseī€ƒproperī€ƒ
installation procedures as described in these
instructions when installing this air conditioner.
INSTALLATION INSTRUCTIONS
NOTE: Theseī€ƒinstructionsī€ƒdescribeī€ƒinstallationī€ƒinī€ƒaī€ƒtypicalī€ƒwoodī€ƒframedī€ƒwindowī€ƒwithī€ƒaī€ƒwoodī€ƒSLIDE-BYī€ƒsash,ī€ƒorī€ƒ
installationī€ƒinī€ƒaī€ƒmetalī€ƒCASEMENTī€ƒwindow.ī€ƒModiīƒ„cationī€ƒmayī€ƒbeī€ƒnecessaryī€ƒwhenī€ƒinstallingī€ƒinī€ƒwindowsī€ƒmadeī€ƒdiī‰ˆerentlyī€ƒ
than those shown in these instructions.
INSTALLATION TIPS:
For wood-frame casement windows:
It may be necessary to construct a frame,
usingī€ƒatī€ƒleastī€ƒ1-inchī€ƒthickī€ƒwood,ī€ƒwithī€ƒaī€ƒ15Ā½ī€ƒ
inch wide opening.
FOR BRICK OR CEMENT BUILDING CONSTRUCTION:
It may be necessary to put a wood stool strip
under the unit for mounting purposes.
STEP 1:
MAKE SURE YOU HAVE ALL THE
NECESSARY PARTS
Installationī€ƒkitī€ƒcontents:
ī€ƒ 1.ī€ƒ Platformī€ƒ(1)
ī€ƒ 2.ī€ƒ Supportī€ƒbraceī€ƒ(1)
ī€ƒ 3.ī€ƒ Adjustmentī€ƒboltī€ƒ(1)
ī€ƒ 4.ī€ƒ Hexī€ƒīƒ…angeī€ƒnut-1/4ā€ī€ƒ(1)
ī€ƒ 5.ī€ƒ Trackī€ƒsealī€ƒ(1)
ī€ƒ 6.ī€ƒ Sideī€ƒchannelī€ƒsealī€ƒ(1)
ī€ƒ 7.ī€ƒ Foamī€ƒsealī€ƒstrip/sashī€ƒsealī€ƒ(1)
ī€ƒ 8.ī€ƒ Safetyī€ƒbracketī€ƒ(1)
ī€ƒ 9.ī€ƒ Screw-ī€ƒ2ī€ƒ1/2ā€ī€ƒ(2)ī€ƒor
ī€ƒ 10.ī€ƒ Screw-ī€ƒ1ī€ƒ3/4ā€ī€ƒ(2)ī€ƒor
ī€ƒ 11.ī€ƒ Screw-ī€ƒ1ā€ī€ƒ(2)
ī€ƒ 12.ī€ƒ Screw-ī€ƒ3/4ā€ī€ƒ(6)
ī€ƒ 13.ī€ƒ Screw-ī€ƒ3/4ā€ī€ƒself-threadingī€ƒ(7)
ī€ƒ 14.ī€ƒ Windowī€ƒlockingī€ƒbracketī€ƒ(1)
ī€ƒ 15.ī€ƒ Plasticī€ƒwindowī€ƒpanelī€ƒ(1)
ī€ƒ 16.ī€ƒ Sideī€ƒchannelī€ƒ(2)
ī€ƒ 17.ī€ƒ Screw-ī€ƒ3/8ā€ī€ƒ(6)
ī€ƒ 18.ī€ƒ Panelī€ƒframe/sealī€ƒassemblyī€ƒ(1)
You will have only
one of these sets
of screws:
#9, #10 or #11.
Tools Required (Not Included):
ā€¢ī€ƒFlat-headī€ƒscrewdriver
ā€¢ī€ƒPhillips-headī€ƒscrewdriver
ā€¢ī€ƒCarpenterā€™sī€ƒlevel
ā€¢ī€ƒTapeī€ƒmeasure
ā€¢ī€ƒFineī€ƒtoothī€ƒsaw
ā€¢ī€ƒElectricī€ƒorī€ƒhandī€ƒdrill
PREPARING FOR INSTALLATION
5
NOTE: Use scale below to measure length of your screws The
scale will be helpful when separating screws for installation.
STEP 2:
CHOOSE PROPER SIZED WINDOW, AS
SHOWN TO THE RIGHT.
ā€¢ī€ƒ15Ā½ī€ƒinchesī€ƒmin.ī€ƒwidth
ā€¢ī€ƒ16Ā¼ī€ƒinchesī€ƒmax.ī€ƒwidthī€ƒ(forī€ƒcasementī€ƒwindows)
ā€¢ī€ƒ21Ā¼ī€ƒinchesī€ƒmin.ī€ƒheightī€ƒ(withī€ƒwindowī€ƒpanelī€ƒretainer)
ā€¢ī€ƒ20ī€ƒ5/16ī€ƒinchesī€ƒmin.ī€ƒheightī€ƒ(windowī€ƒpanelī€ƒretainerī€ƒremoved)
ā€¢ī€ƒ39ī€ƒ7/16 inches max. height
NOTE: Height measurement must be of a clear opening above
mounting platform. In some cases, due to a variety of stop and
trackī€ƒarrangements,ī€ƒtheī€ƒaboveī€ƒdimensionsī€ƒmayī€ƒvaryī€ƒslightly.ī€ƒ
If necessary, installation can be made by alternating window
jambs.ī€ƒ(Seeī€ƒAlternateī€ƒWindowī€ƒJambī€ƒApplicationsī€ƒbelow).
STEP 3:
CHOOSE THE PROPER WINDOW LOCATION
Chooseī€ƒaī€ƒwindowī€ƒthatī€ƒallowsī€ƒtheī€ƒcooledī€ƒairī€ƒtoī€ƒīƒ…owī€ƒfreelyī€ƒandī€ƒ
directlyī€ƒintoī€ƒroom(s)ī€ƒyouī€ƒwishī€ƒtoī€ƒcool.ī€ƒRemember,ī€ƒitī€ƒisī€ƒdiī‰‰cultī€ƒ
to move air around corners. Also, choose a window that is
withinī€ƒ6ī€ƒfeetī€ƒofī€ƒanī€ƒelectricalī€ƒoutlet.ī€ƒ(Seeī€ƒā€œElectricalī€ƒInformationā€ī€ƒ
onī€ƒPageī€ƒ3).ī€ƒDO NOT USE AN EXTENSION CORD.
ALTERNATE WINDOW JAMB APPLICATIONS
Toī€ƒinstallī€ƒinī€ƒwindowsī€ƒhavingī€ƒnoī€ƒīƒ…angesī€ƒorī€ƒwoodī€ƒstopsī€ƒonī€ƒ
theī€ƒtopī€ƒandī€ƒsideī€ƒjambs,ī€ƒtheī€ƒchannelsī€ƒandī€ƒpanelī€ƒframeī€ƒmustī€ƒ
īƒ„tī€ƒagainstī€ƒaī€ƒmountingī€ƒīƒ…angeī€ƒ(orī€ƒ1/16-inchī€ƒmax.ī€ƒthickī€ƒangle)ī€ƒ
attachedī€ƒtoī€ƒtheī€ƒwindowī€ƒjambs.ī€ƒFigureī€ƒAī€ƒshowsī€ƒthisī€ƒangleī€ƒ
installed.ī€ƒFiguresī€ƒBī€ƒ&ī€ƒCī€ƒshowī€ƒalternateī€ƒtreatments.ī€ƒOnī€ƒtheī€ƒ
sash side of the opening, the leading corner of the inner sash
becomesī€ƒtheī€ƒīƒ…ange.ī€ƒYouī€ƒcanī€ƒpurchaseī€ƒtheī€ƒangleī€ƒstripī€ƒlocally.
Identify Screws
By Length
(25mm)
1ā€ 1 3/4ā€
(63mm)
2 1/2ā€
3/8ā€ 3/4ā€
(19mm)
(44mm)
(10mm)
15Ā½ in.
minimum
width
A
Add angle to
wood stop
Room
3/4"
or 1" 3/4"
or 1" 3/4" x 3/4"
or 1" x 1"
Room Room
B
Add wood
as shown
C
Add 16- or 18-
gauge angle
20
5/16 in.
minimum
height
39
7/16 in.
maximum
height
6 foot
power cord
reach
16Ā¼ in.
max. width
(casement
windows)
6
STEP 1:
ATTACH SUPPORT BRACE TO PLATFORM
Useī€ƒadjustmentī€ƒboltī€ƒandī€ƒhexī€ƒīƒ…angeī€ƒnutī€ƒtoī€ƒcompleteī€ƒ
assembly.ī€ƒChooseī€ƒslotī€ƒandī€ƒadjustmentī€ƒboltī€ƒholeī€ƒlocationsī€ƒ
thatī€ƒwillī€ƒcreateī€ƒaī€ƒ45ī€ƒdegreeī€ƒangleī€ƒbetweenī€ƒplatformī€ƒandī€ƒ
support brace. Try assembly in the window to determine
ifī€ƒplatformī€ƒwillī€ƒrestī€ƒproperly,ī€ƒandī€ƒallowī€ƒproperī€ƒslope.ī€ƒ(5/16"
lowerī€ƒonī€ƒoutside).ī€ƒ(Fig.ī€ƒ1)
NOTE: If you are planning to use a sliding-protection board
(Seeī€ƒStepī€ƒ5)ī€ƒonī€ƒtheī€ƒoutsideī€ƒofī€ƒyourī€ƒhouse,ī€ƒholdī€ƒboardī€ƒinī€ƒ
place when testing assembly of window.
STEP 2:
MEASURE, AND LIGHTLY MARK A LINE
8 11/16" FROM WINDOW JAMB.
NOTE: If any sash stop protrudes more than 1" from the
sideī€ƒwindowī€ƒjambs,ī€ƒtheī€ƒ8ī€ƒ
11/16" measurement must be
increased accordingly. Screen and storm window frames
mayī€ƒalsoī€ƒrequireī€ƒadjustmentsī€ƒtoī€ƒtheī€ƒmeasurement.ī€ƒ(Fig.ī€ƒ2)
STEP 3:
CENTER PLATFORM ASSEMBLY.
Center the platform assembly on the line with inside
platformī€ƒtabī€ƒpressedī€ƒagainstī€ƒinsideī€ƒedgeī€ƒofī€ƒwindowī€ƒtrack.ī€ƒ
Usingī€ƒtheī€ƒholesī€ƒinī€ƒtheī€ƒplatformī€ƒasī€ƒaī€ƒguide,ī€ƒmarkī€ƒandī€ƒdrillī€ƒ
two 9/64"ī€ƒdiameterī€ƒholes.ī€ƒDrillī€ƒholesī€ƒinī€ƒeitherī€ƒtrackī€ƒorī€ƒstool.ī€ƒ
(Fig.ī€ƒ3ī€ƒ&ī€ƒFig.ī€ƒ4)
STEP 4:
PEEL OFF PROTECTIVE BACKING FROM
TRACK SEAL.
Next,ī€ƒapplyī€ƒsealī€ƒtoī€ƒroomī€ƒsideī€ƒofī€ƒwindowī€ƒtrack.ī€ƒCenterī€ƒofī€ƒ
sealī€ƒstripī€ƒshouldī€ƒcoincideī€ƒwithī€ƒtheī€ƒlineī€ƒmarkedī€ƒinī€ƒStepī€ƒ2.ī€ƒ
The two screw holes drilled in Step 3 should be directly
aboveī€ƒsealī€ƒstripī€ƒinī€ƒtheī€ƒinnerī€ƒtrack.ī€ƒ(Fig.ī€ƒ5)
STEP 5:
SECURELY ATTACH A SIDING-PROTEC-
TION BOARD TO SIDE OF HOUSE.
NOTE: Siding-protection board should be long enough to
span 2 wall studs.
NOTE:ī€ƒAdjustī€ƒtheī€ƒplatformī€ƒassemblyī€ƒsoī€ƒthatī€ƒtheī€ƒairī€ƒ
conditionerī€ƒwillī€ƒbeī€ƒ1ā…›"ī€ƒtoī€ƒ1Ā½"ī€ƒlowerī€ƒthanī€ƒtheī€ƒfrontī€ƒ(tiltedī€ƒ
aboutī€ƒ3Āŗī€ƒtoī€ƒ4Āŗī€ƒdownwardī€ƒtoī€ƒtheī€ƒoutside).ī€ƒAfterī€ƒproperī€ƒ
installation, condensation should not drain from the
overīƒ…owī€ƒdrainī€ƒholeī€ƒduringī€ƒnormalī€ƒuse.ī€ƒ(Youī€ƒmayī€ƒseeī€ƒ
condensation in periods of high humidity. However, if
condensationī€ƒoccursī€ƒduringī€ƒlowī€ƒorī€ƒnormalī€ƒhumidity,ī€ƒadjustī€ƒ
theī€ƒslopeī€ƒslightly.)ī€ƒ(Fig.ī€ƒ6)
Fig. 1
Fig. 2
Fig. 3
Fig. 6
Fig. 5
Fig. 4
INSTALLING UNIT IN A SLIDING WINDOW
CAUTION
Property Damage Hazard-Failure to adhere to the
following precaution could result in damage to window
or air conditioner. Beī€ƒsureī€ƒwoodī€ƒstoolī€ƒorī€ƒwindowī€ƒtrackī€ƒ
is securely attached to the building construction. Use
longer screws in sub-framing if necessary.
Ā¼ in. (6mm)
HEX FLANGE NUT
8
11/16 inches
Center platform
assembly on the
line with platform
tab pressed against
window track.
Alternate screw location
(depending on the stool depth)
Apply track seal
to window side
of track.
Platform tab
Window seal
Window track
Platform Assembly
Inside wall
of house
Siding-protection
board
7
STEP 6:
PLACE PLATFORM ASSEMBLY
Withī€ƒplatformī€ƒtabī€ƒagainstī€ƒinsideī€ƒofī€ƒwindowī€ƒtrack,ī€ƒplaceī€ƒ
platformī€ƒassemblyī€ƒandī€ƒattachī€ƒitī€ƒtoī€ƒwindowī€ƒjamb.ī€ƒUseī€ƒ
appropriateī€ƒlengthī€ƒscrewsī€ƒ(Itemsī€ƒ9ī€ƒā€“11ī€ƒinī€ƒPreparingī€ƒForī€ƒ
Installationī€ƒonī€ƒpg.ī€ƒ4).ī€ƒ(Fig.ī€ƒ7)
STEP 7:
ADJUST PLATFORM ASSEMBLY
Adjustī€ƒtheī€ƒplatformī€ƒassemblyī€ƒsoī€ƒthatī€ƒtheī€ƒoutsideī€ƒedgeī€ƒisī€ƒ
5/16ī€ƒinchesī€ƒlowerī€ƒthanī€ƒinsideī€ƒedge.ī€ƒ(Fig.ī€ƒ7)ī€ƒThisī€ƒensuresī€ƒ
proper water drainage from the air conditioner.
STEP 8:
LEVEL PLATFORM ASSEMBLY FROM
SIDE-TO-SIDE
Also,ī€ƒmakeī€ƒsureī€ƒwindowī€ƒtrackī€ƒisī€ƒlevel.ī€ƒUseī€ƒlevelingī€ƒshimsī€ƒ
as necessary to ensure unit is level from side-to-side.
STEP 9:
MEASURE HEIGHT OF WINDOW
OPENING
Begin measuring height of window opening from top of
platform assembly as shown right. Subtract 20 5/8 inches.
Markī€ƒthisī€ƒmeasurementī€ƒonī€ƒplasticī€ƒwindowī€ƒpanel,ī€ƒalongī€ƒtheī€ƒ
longerī€ƒside.ī€ƒ(Fig.ī€ƒ8)
STEP 10:
CLAMP PLASTIC WINDOW PANEL
Clamp the plastic window panel between a board and a
workī€ƒtable,ī€ƒandī€ƒcutī€ƒalongī€ƒcuttingī€ƒlineī€ƒwithī€ƒaī€ƒīƒ„neī€ƒtoothī€ƒsaw.ī€ƒ
Removeī€ƒanyī€ƒburrsī€ƒwithī€ƒaī€ƒīƒ„le.
STEP 11:
FASTEN SIDE CHANNELS
Fasten the side channels to the sides of the unit using
3ī€ƒscrewsī€ƒ(Itemī€ƒ#17,ī€ƒpageī€ƒ4)ī€ƒperī€ƒchannel.ī€ƒStartī€ƒwithī€ƒīƒ„rstī€ƒ
screwī€ƒatī€ƒtopī€ƒofī€ƒchannel.ī€ƒMakeī€ƒsureī€ƒhookī€ƒendsī€ƒofī€ƒchannelsī€ƒ
faceī€ƒtowardī€ƒbackī€ƒofī€ƒunit.ī€ƒ(Fig.ī€ƒ9)
STEP 12:
SLIDE PLASTIC WINDOW PANEL INTO
PANEL FRAME
Slide in the window panel, with the smooth side facing the
room. Slide panel frame assembly into side channels of
theī€ƒACī€ƒcabinet.ī€ƒMakeī€ƒsureī€ƒplasticī€ƒwindowī€ƒpanelī€ƒisī€ƒīƒ„rmlyī€ƒ
enclosedī€ƒonī€ƒallī€ƒsidesī€ƒbyī€ƒtheī€ƒretainerī€ƒgrooves.ī€ƒ(Fig.ī€ƒ10)
STEP 13:
CUT SIDE CHANNEL SEAL
Cutī€ƒtheī€ƒsideī€ƒchannelī€ƒsealī€ƒintoī€ƒ2ī€ƒequalī€ƒlengths.ī€ƒRemoveī€ƒ
protectiveī€ƒbackingī€ƒandī€ƒapplyī€ƒitī€ƒtoī€ƒtheī€ƒrearī€ƒsideī€ƒofī€ƒcabinetī€ƒ
sideī€ƒchannels,ī€ƒstartingī€ƒjustī€ƒbelowī€ƒpanelī€ƒframeī€ƒassembly.ī€ƒ
Pinchī€ƒoī‰ˆī€ƒexcessī€ƒlengthī€ƒsoī€ƒsealī€ƒisī€ƒevenī€ƒwithī€ƒtheī€ƒbottomī€ƒofī€ƒ
theī€ƒcabinetī€ƒsideī€ƒchannel.ī€ƒ(Fig.ī€ƒ11)
Fig. 7
Fig. 8 Fig. 9
Fig. 10
Fig. 11
Measure from here
Put
platform
tab against
inside of
track.
Fastening Side
Channels
Panel
Frame
Plastic
window panel
Measure
distance
& subtract
20ā…ī€ƒin.
approx. 1" to 1Ā¼"
Apply
weather
seal to side
channels
just below
edge of
panel frame
INSTALLING UNIT IN A SLIDING WINDOW (CONT.)
8
Fig. 12
Fig. 13
Fig. 14
Fig. 15
STEP 14:
TO REMOVE FRONT
1. Remove the two front retaining screws from the
frontī€ƒframe.ī€ƒ(Figī€ƒ12)
2. Gently pull the front out and lift up to release it from
the case.
3.ī€ƒReleaseī€ƒtheī€ƒcontrolī€ƒboardī€ƒplug.ī€ƒ(Fig.ī€ƒ12)
NOTE: DO NOT push or pull air direction louvers.
STEP 15:
PLACE AC IN WINDOW OPENING
The unit should sit on the platform assembly so that the
window panel frame and cabinet side channels are against
theī€ƒtopī€ƒandī€ƒsideī€ƒwindowī€ƒjambs.ī€ƒ(Fig.ī€ƒ13)
STEP 16:
SLIDE INNER WINDOW SASH FIRMLY
AGAINST SIDE OF CABINET
Makeī€ƒsureī€ƒnotī€ƒtoī€ƒpeelī€ƒtheī€ƒsealī€ƒstripsī€ƒfromī€ƒtheī€ƒwindowī€ƒtrackī€ƒ
andī€ƒcabinetī€ƒsideī€ƒchannels.ī€ƒIfī€ƒtheī€ƒpanelī€ƒframeī€ƒdoesī€ƒnotī€ƒīƒ„tī€ƒ
snugly to the inner window sash, secure the panel frame to
the sash with Ā¾" screws, or Ā¾" self-threading screws. Use
theī€ƒpartiallyī€ƒpluggedī€ƒholesī€ƒinī€ƒtheī€ƒpanelī€ƒframe.ī€ƒDrillī€ƒā…›"pilotī€ƒ
holesī€ƒforī€ƒtheī€ƒscrews.ī€ƒ(Fig.ī€ƒ13)
STEP 17:
HOOK THE SAFETY BRACKET
Theī€ƒsafetyī€ƒbracketī€ƒshouldī€ƒbeī€ƒhookedī€ƒoverī€ƒtheī€ƒbaseī€ƒofī€ƒtheī€ƒ
unit and fastened to the front of the platform assembly. Use
aī€ƒĀ¾"ī€ƒself-threadingī€ƒscrew.ī€ƒ(Fig.ī€ƒ14)
NOTE: Theī€ƒbracketī€ƒpreventsī€ƒmovementī€ƒofī€ƒtheī€ƒairī€ƒ
conditionerī€ƒ(eitherī€ƒinī€ƒorī€ƒout)ī€ƒafterī€ƒcompletingī€ƒtheī€ƒ
installation.
STEP 18:
STUFF THE FOAM SEAL STRIP/
SASH SEAL
Stuī‰ˆī€ƒtheī€ƒfoamī€ƒsealī€ƒstripī€ƒbetweenī€ƒtheī€ƒverticalī€ƒsashī€ƒandī€ƒtheī€ƒ
windowī€ƒglass.ī€ƒ(Fig.ī€ƒ15)
STEP 19:
LOCK THE INNER WINDOW SASH
Usingī€ƒtheī€ƒwindowī€ƒlockingī€ƒbracket,ī€ƒlockī€ƒtheī€ƒinnerī€ƒwindowī€ƒ
sash to the base of the outer window sash. Use one Ā¾"
screw,ī€ƒorī€ƒĀ¾"ī€ƒself-threadingī€ƒscrew.ī€ƒ(Drillī€ƒā…›"ī€ƒpilotī€ƒhole).
STEP 20:
TO REPLACE THE FRONT
First,ī€ƒreconnectī€ƒtheī€ƒcontrolī€ƒboardī€ƒplug.ī€ƒMakeī€ƒsureī€ƒtheī€ƒ
exhaust control positioned through the front is in the proper
location. Then, replace the retaining screws that hold the
panel in place. Do not push or pull the front louvers.
Safety Bracket
Sash
Seal
Window
locking
bracket
Front
Retaining
Screw
Slide inner
window
sash ļ¬rmly
against
cabinet
INSTALLING UNIT IN A SLIDING WINDOW (CONT.)
9
NOTE: Openī€ƒtheī€ƒwindowī€ƒtheī€ƒmaximumī€ƒamountī€ƒtoī€ƒallowī€ƒ
forī€ƒclearanceī€ƒofī€ƒtheī€ƒcabinet.ī€ƒTheī€ƒcrankī€ƒhandleī€ƒshouldī€ƒbeī€ƒ
removedī€ƒtoī€ƒallowī€ƒtheī€ƒplatformī€ƒtoī€ƒbeī€ƒfastenedī€ƒtoī€ƒtheī€ƒjamb.ī€ƒ
Ifī€ƒtheī€ƒwindowī€ƒcannotī€ƒopenī€ƒfarī€ƒenoughī€ƒ(moreī€ƒthanī€ƒ15Ā½ī€ƒ
inches)ī€ƒforī€ƒtheī€ƒcabinetī€ƒtoī€ƒclearī€ƒtheī€ƒwindow,ī€ƒremoveī€ƒtheī€ƒ
window entirely by drilling out the rivets. Bolts can serve as
the rivets in the future.
Toī€ƒavoidī€ƒcrankī€ƒhandleī€ƒandī€ƒwindowī€ƒclearanceī€ƒproblems,ī€ƒtheī€ƒ
unit can be installed in a stationary sash section. However,
theī€ƒhorizontalī€ƒmullionī€ƒandī€ƒtheī€ƒ2ī€ƒglassī€ƒpanelsī€ƒmustī€ƒbeī€ƒ
removed before installation.
STEP 1:
ATTACH SUPPORT BRACE TO PLATFORM
Useī€ƒtheī€ƒadjustmentī€ƒboltī€ƒandī€ƒhexī€ƒīƒ…angeī€ƒnutī€ƒtoī€ƒcompleteī€ƒ
theī€ƒassembly.ī€ƒChooseī€ƒtheī€ƒslotī€ƒandī€ƒadjustmentī€ƒboltī€ƒholeī€ƒ
locationsī€ƒthatī€ƒwillī€ƒcreateī€ƒaī€ƒ45ī€ƒdegreeī€ƒangleī€ƒbetweenī€ƒtheī€ƒ
platform and the support brace. Try the assembly in the
window to determine if the platform will rest properly, and
allowī€ƒtheī€ƒproperī€ƒslopeī€ƒ(ī€ƒ
5/16ī€ƒinchī€ƒlowerī€ƒonī€ƒoutside).ī€ƒ(Fig.ī€ƒ1)
NOTE: If you are planning to use a siding-protection board
(Seeī€ƒStepī€ƒ6)ī€ƒonī€ƒtheī€ƒoutsideī€ƒofī€ƒyourī€ƒhouse,ī€ƒholdī€ƒtheī€ƒboardī€ƒ
in place when testing the assembly in the window.
STEP 2:
DRILL A 9/64 IN. DIAMETER PILOT HOLE
Drillī€ƒtheī€ƒholeī€ƒinī€ƒtheī€ƒwindowī€ƒjambī€ƒanī€ƒequalī€ƒdistanceī€ƒfromī€ƒ
eachī€ƒsideī€ƒofī€ƒtheī€ƒjambī€ƒ(Fig.ī€ƒ2),ī€ƒandī€ƒ3/16ī€ƒinchī€ƒupī€ƒfromī€ƒtheī€ƒ
window sill. If the hole coincides with the window lever
slotī€ƒinī€ƒtheī€ƒjambī€ƒbottom,ī€ƒanī€ƒadditionalī€ƒholeī€ƒwillī€ƒhaveī€ƒtoī€ƒbeī€ƒ
drilledī€ƒthroughī€ƒtheī€ƒplatformī€ƒedgeī€ƒandī€ƒtheī€ƒwindowī€ƒjambī€ƒtoī€ƒ
miss this slot.
STEP 3:
PEEL OFF THE PROTECTIVE BACKING
Peelī€ƒoī‰ˆī€ƒtheī€ƒbackingī€ƒfromī€ƒtheī€ƒtrackī€ƒseal,ī€ƒandī€ƒstickī€ƒtheī€ƒsealī€ƒ
toī€ƒtheī€ƒwindowī€ƒsillī€ƒonī€ƒtheī€ƒoutsideī€ƒofī€ƒtheī€ƒbottomī€ƒjamb.ī€ƒ
(Fig.ī€ƒ3)
STEP 4:
SCREW THE PLATFORM ASSEMBLY TO
THE WINDOW JAMB
Screw the platform assembly using the pilot hole drilled in
Stepī€ƒ2.ī€ƒUseī€ƒaī€ƒĀ¾ī€ƒinchī€ƒself-threadingī€ƒscrew.ī€ƒ(Fig.ī€ƒ4)
INSTALLING UNIT IN A CASEMENT WINDOW
Fig. 1
Fig. 2 Fig. 3
Fig. 4
Ā¼ in. (6mm)
HEX FLANGE NUT
8
11/16 inches
Platform Assembly
Track seal
Screw
Window
Jamb
10
STEP 5:
ADJUST PLATFORM ASSEMBLY PROPERLY
Adjustī€ƒtheī€ƒplatformī€ƒassemblyī€ƒsoī€ƒthatī€ƒtheī€ƒrearī€ƒofī€ƒtheī€ƒairī€ƒ
conditioner is 5/16 inches lower than the front. This ensures
properī€ƒwaterī€ƒdrainageī€ƒfromī€ƒtheī€ƒairī€ƒconditioner.ī€ƒ(Fig.ī€ƒ5)
NOTE:ī€ƒAdjustī€ƒtheī€ƒplatformī€ƒassemblyī€ƒsoī€ƒthatī€ƒtheī€ƒairī€ƒconditionerī€ƒ
willī€ƒbeī€ƒ1ā…›"ī€ƒtoī€ƒ1Ā½"ī€ƒlowerī€ƒthanī€ƒtheī€ƒfrontī€ƒ(tiltedī€ƒaboutī€ƒ3Āŗī€ƒtoī€ƒ4Āŗī€ƒ
downwardī€ƒtoī€ƒtheī€ƒoutside).ī€ƒAfterī€ƒproperī€ƒinstallation,ī€ƒcondensationī€ƒ
shouldī€ƒnotī€ƒdrainī€ƒfromī€ƒtheī€ƒoverīƒ…owī€ƒdrainī€ƒholeī€ƒduringī€ƒnormalī€ƒ
use.ī€ƒ(Youī€ƒmayī€ƒseeī€ƒcondensationī€ƒinī€ƒperiodsī€ƒofī€ƒhighī€ƒhumidity.ī€ƒ
However, if condensation occurs during low or normal humidity,
adjustī€ƒtheī€ƒslopeī€ƒslightly.)
STEP 6:
SECURELY ATTACH A SIDING-
PROTECTION BOARD
Attach the board to the side of the house where the platform
assembly hits the house. The siding-protection board should be
longī€ƒenoughī€ƒtoī€ƒspanī€ƒ2ī€ƒwallī€ƒstuds.ī€ƒ(Fig.ī€ƒ6)
STEP 7:
MEASURE THE HEIGHT OF THE
WINDOW OPENING
Measureī€ƒfromī€ƒtheī€ƒtopī€ƒofī€ƒtheī€ƒplatformī€ƒassembly.ī€ƒSubtractī€ƒ20ī€ƒā…ī€ƒ
inches.ī€ƒMarkī€ƒthisī€ƒmeasurementī€ƒonī€ƒtheī€ƒplasticī€ƒwindowī€ƒpanel,ī€ƒ
alongī€ƒtheī€ƒlongerī€ƒside.ī€ƒ(Fig.ī€ƒ7)
STEP 8:
CLAMP THE PLASTIC WINDOW PANEL
Clampī€ƒtheī€ƒplasticī€ƒwindowī€ƒpanelī€ƒbetweenī€ƒaī€ƒboardī€ƒandī€ƒaī€ƒworkī€ƒ
table,ī€ƒandī€ƒcutī€ƒalongī€ƒtheī€ƒcuttingī€ƒlineī€ƒwithī€ƒaī€ƒīƒ„neī€ƒtoothī€ƒsaw.ī€ƒ
Removeī€ƒanyī€ƒburrsī€ƒwithī€ƒaī€ƒīƒ„le.
STEP 9:
FASTEN THE SIDE CHANNELS TO THE SIDE
OF THE UNIT
Usingī€ƒthreeī€ƒscrewsī€ƒ(Itemī€ƒ#17,ī€ƒPg.ī€ƒ4)ī€ƒperī€ƒchannelī€ƒfastenī€ƒtheī€ƒ
sideī€ƒchannelsī€ƒtoī€ƒtheī€ƒsideī€ƒofī€ƒtheī€ƒunit.ī€ƒMakeī€ƒsureī€ƒhookī€ƒendsī€ƒofī€ƒ
channelsī€ƒfaceī€ƒtowardī€ƒtheī€ƒbackī€ƒofī€ƒunit.
STEP 10:
SLIDE THE PLASTIC WINDOW PANEL INTO
PANEL FRAME
Slide the plastic window panel in, with the smooth side facing
the outside. Slide the panel frame assembly into the side
channelsī€ƒofī€ƒtheī€ƒairī€ƒconditionerī€ƒcabinet.ī€ƒMakeī€ƒsureī€ƒtheī€ƒplasticī€ƒ
window
panelī€ƒisī€ƒīƒ„rmlyī€ƒenclosedī€ƒonī€ƒallī€ƒsidesī€ƒbyī€ƒtheī€ƒretainerī€ƒ
grooves.ī€ƒ(Fig.ī€ƒ8)
STEP 11:
CUT SIDE CHANNEL SEAL
Cutī€ƒtheī€ƒchannelī€ƒsealī€ƒintoī€ƒ2ī€ƒequalī€ƒlengths.ī€ƒRemoveī€ƒtheī€ƒprotectiveī€ƒ
backingī€ƒandī€ƒapplyī€ƒitī€ƒtoī€ƒtheī€ƒrearī€ƒsideī€ƒofī€ƒtheī€ƒcabinetī€ƒsideī€ƒ
channels,ī€ƒstartingī€ƒjustī€ƒbelowī€ƒtheī€ƒpanelī€ƒframeī€ƒassembly.ī€ƒPinchī€ƒoī‰ˆī€ƒ
excess length so the seal is even with the bottom of the cabinet
sideī€ƒchannel.ī€ƒ(Fig.9)
INSTALLING UNIT IN A CASEMENT WINDOW (CONT.)
Fig. 6
Fig. 5
Fig. 7
Fig. 8
Fig. 9
Measure from here approx. 1ā…›" to 1Ā½"
Measure
distance
& subtract
20ā…ī€ƒin.
Fasten
sliding-
protection
board to
the house
siding.
Apply
weather
seal to side
channels
just below
edge of
panel frame.
Panel frame
Plastic window
panel
11
STEP 12:
TO REMOVE FRONT:
ā€¢ī€ƒ Removeī€ƒtheī€ƒtwoī€ƒfrontī€ƒretainingī€ƒscrewsī€ƒfromī€ƒtheī€ƒ
frontī€ƒframe.ī€ƒ(Fig.ī€ƒ10)
ā€¢ī€ƒ Gentlyī€ƒpullī€ƒtheī€ƒfrontī€ƒoutī€ƒandī€ƒliftī€ƒupī€ƒtoī€ƒreleaseī€ƒitī€ƒfromī€ƒ
the case.
ā€¢ī€ƒ Releaseī€ƒtheī€ƒcontrolī€ƒboardī€ƒplug.ī€ƒ(Fig.ī€ƒ10)
NOTE: DO NOT push or pull air directional louvers.
STEP 13:
PLACE THE AIR CONDITIONER IN THE
WINDOW OPENING
The air conditioner should sit on the platform assembly
so that the window panel frame, and the cabinet side
channelsī€ƒareī€ƒagainstī€ƒtheī€ƒtopī€ƒandī€ƒsideī€ƒwindowī€ƒjambs.ī€ƒSideī€ƒ
channelsī€ƒshouldī€ƒoverlapī€ƒsideī€ƒwindowī€ƒjambsī€ƒequally.ī€ƒ
(Fig.ī€ƒ11)
STEP 14:
DRILL TWO 9/64 INCH DIAMETER
PILOT HOLES
Drillī€ƒtheī€ƒtwoī€ƒpilotī€ƒholesī€ƒinī€ƒtheī€ƒtopī€ƒwindowī€ƒjambī€ƒinī€ƒlineī€ƒ
with the partially plugged holes in the panel frame.
Secureī€ƒtheī€ƒpanelī€ƒframeī€ƒtoī€ƒtheī€ƒwindowī€ƒjambī€ƒwithī€ƒtwoī€ƒ
Ā¾ inch self-threading screws. If additional holding is
necessary, two screws may be used on the sides of the
panel frame as well.
STEP 15:
DRILL SCREW-CLEARANCE HOLES
Drill two screw-clearance holes in the cabinet side
channelsī€ƒ(nearī€ƒbottom)ī€ƒandī€ƒtwoī€ƒ9/64 inch diameter pilot
holesī€ƒinī€ƒtheī€ƒsideī€ƒwindowī€ƒjambs.ī€ƒSecureī€ƒtheī€ƒcabinetī€ƒsideī€ƒ
channelsī€ƒtoī€ƒtheī€ƒwindowī€ƒjambsī€ƒwithī€ƒtwoī€ƒĀ¾ī€ƒinchī€ƒself-
threading screws. When doing this, be careful not to twist
the side channel seals with the screws.
NOTE: Inserting screws will prevent the air conditioner from
being pushed into the room.
STEP 16:
TO REPLACE THE FRONT
First,ī€ƒreconnectī€ƒtheī€ƒcontrolī€ƒboardī€ƒplugī€ƒandī€ƒmakeī€ƒsureī€ƒtheī€ƒ
exhaust control positioned through the front is in the proper
location. Then replace the retaining screws that hold the
panel in place. Do not push or pull the front panel louvers.
INSTALLING UNIT IN A CASEMENT WINDOW (CONT.)
Fig. 10
Fig. 11
Front
Retaining
Screw
12
NORMAL SOUNDS
AIR CONDITIONER FEATURES
VIBRATION
Unitī€ƒmayī€ƒvibrateī€ƒandī€ƒmakeī€ƒ
noise because of poor wall
or window construction
or incorrect installation.
Thisī€ƒDOESī€ƒNOTī€ƒindicateī€ƒaī€ƒ
defective unit.
PINGING OR SWITCHING
Droplets of water hitting
condenser during normal
operation may cause ā€œpingingā€
or ā€œswitchingā€ sounds.
HIGH PITCHED CHATTER
Highī€ƒeī‰‰ciencyī€ƒcompressorsī€ƒ
may have a high pitched chatter
during the cooling cycle.
SOUND OF RUSHING AIR
At the front of the unit,
the sound of rushing air
being moved by the fan
may be heard.
GURGLE/HISS
ā€œGurglingā€ or ā€œhissingā€
noise may be heard due
to refrigerant passing
through evaporator during
normal operation.
NOTE: Allī€ƒofī€ƒtheī€ƒpicturesī€ƒinī€ƒthisī€ƒmanualī€ƒareī€ƒforī€ƒexplanatoryī€ƒpurposesī€ƒonly.ī€ƒTheī€ƒactualī€ƒshape/lookī€ƒofī€ƒ
theī€ƒairī€ƒconditionerī€ƒpurchasedī€ƒmayī€ƒbeī€ƒslightlyī€ƒdiī‰ˆerent,ī€ƒbutī€ƒtheī€ƒoperationsī€ƒandī€ƒfunctionsī€ƒareī€ƒsimilar.
Thoroughlyī€ƒfamiliarizeī€ƒyourselfī€ƒwithī€ƒtheī€ƒcontrolī€ƒpanelī€ƒshownī€ƒbelowī€ƒandī€ƒallī€ƒofī€ƒitsī€ƒfunctions.ī€ƒAfterwards,ī€ƒfollowī€ƒtheī€ƒsymbolī€ƒ
forī€ƒtheī€ƒfunctionsī€ƒyouī€ƒdesireī€ƒBEFOREī€ƒoperatingī€ƒtheī€ƒunit.ī€ƒThisī€ƒunitī€ƒcanī€ƒbeī€ƒcontrolledī€ƒbyī€ƒtheī€ƒunitī€ƒcontrolī€ƒorī€ƒwithī€ƒtheī€ƒ
remote control.
ā€œFOLLOW
MEā€
Indicator
Energy Saver
Mode
Sets
Mode
Sleep
Mode
Turns Unit
On or Off
Sets Fan
Speed
Adjusts Temp.
or Time
Exhaust Selector
Remote
Signal
Receptor
Check Filter
Reset Button
Activates
Timer
Displays Temp. or
the Time or
Error Codes
TO TURN UNIT ON OR OFF:
Press ī€ƒON/OFFī€ƒbuttonī€ƒtoī€ƒturnī€ƒtheī€ƒunitī€ƒonī€ƒorī€ƒoī‰ˆ.
NOTE: The unit will automatically initiate the Energy
Saverī€ƒfunctionī€ƒunderī€ƒCOOL,ī€ƒDRYī€ƒandī€ƒAUTOī€ƒ(onlyī€ƒ
AUTO-COOLINGī€ƒandī€ƒAUTO-FANī€ƒmodes).
TO CHANGE TEMPERATURE SETTING:
Press ī€ƒ/ ī€ƒ ī€ƒUP/DOWNī€ƒbuttonī€ƒtoī€ƒchangeī€ƒtheī€ƒ
temperature setting.
NOTE: Pressī€ƒorī€ƒholdī€ƒeitherī€ƒUPī€ƒ( )ī€ƒorī€ƒDOWNī€ƒ
( )ī€ƒbuttonī€ƒuntilī€ƒtheī€ƒdesiredī€ƒtemperatureī€ƒisī€ƒseenī€ƒonī€ƒ
the display. The temperature will be automatically
maintainedī€ƒanywhereī€ƒbetweenī€ƒ62Ā°Fī€ƒ(17Ā°C)ī€ƒandī€ƒ86Ā°Fī€ƒ
(30Ā°C).ī€ƒIfī€ƒyouī€ƒwantī€ƒtheī€ƒdisplayī€ƒtoī€ƒreadī€ƒtheī€ƒactualī€ƒroomī€ƒ
temperature,ī€ƒseeī€ƒā€œToī€ƒOperateī€ƒonī€ƒFanī€ƒOnlyā€ī€ƒsection.
TO ADJUST FAN SPEEDS:
Press to select the Fan Speed in four steps: Auto,
Low, Med or High. Each time the button is pressed,
theī€ƒfanī€ƒspeedī€ƒisī€ƒshifted.ī€ƒInī€ƒDRYī€ƒmode,ī€ƒtheī€ƒfanī€ƒspeedī€ƒ
is controlled at Low automatically.
Close Open
Auto Low
Med High
Auto
On Off
Cool
Dry Fan Follow Me
Exhaust
Fan Timer Mode Energy
Saver Sleep Check
Filter
TEMP/TIMER
13
SLEEP FEATURE:
Press the SLEEP button to initiate SLEEP
mode. In this mode, the selected temperature will
increaseī€ƒbyī€ƒ2Ā°Fī€ƒ(1Ā°C)ī€ƒ30ī€ƒminutesī€ƒafterī€ƒtheī€ƒmodeī€ƒisī€ƒ
selected.ī€ƒTheī€ƒtemperatureī€ƒwillī€ƒthenī€ƒincreaseī€ƒ(cooling)ī€ƒ
orī€ƒdecreaseī€ƒ(unitsī€ƒwithī€ƒheatingī€ƒonly)ī€ƒbyī€ƒanotherī€ƒ
2Ā°Fī€ƒ(1Ā°C)ī€ƒafterī€ƒanī€ƒadditionalī€ƒ30ī€ƒminutes.ī€ƒThisī€ƒnewī€ƒ
temperature will be maintained for 6 hours before it
returns to the originally selected temperature. This
ends the SLEEP mode and the unit will continue
to operate as originally programmed. The SLEEP
mode program can be canceled at any time during
operation by pressing the SLEEP button again.
CHECK FILTER FEATURE:
Press the CHECK FILTER button to initiate this
feature. This feature is a reminder to clean the Air
Filterī€ƒforī€ƒmoreī€ƒeī‰‰cientī€ƒoperation.ī€ƒTheī€ƒLEDī€ƒ(light)ī€ƒwillī€ƒ
illuminateī€ƒafterī€ƒ250ī€ƒhoursī€ƒofī€ƒoperation.ī€ƒToī€ƒresetī€ƒafterī€ƒ
cleaningī€ƒtheī€ƒīƒ„lter,ī€ƒpressī€ƒtheī€ƒCHECK FILTER button
andī€ƒtheī€ƒlightī€ƒwillī€ƒgoī€ƒoī‰ˆ.
ENERGY SAVER FEATURE:
Press the ENERGYī€ƒSAVER button to initiate this
function. This function is available on COOL, DRYī€ƒ
and AUTOī€ƒ(onlyī€ƒAUTO-COOLINGī€ƒand AUTO-FAN)ī€ƒ
modes. In this mode, the fan will continue to run for 3
minutesī€ƒafterī€ƒtheī€ƒcompressorī€ƒshutsī€ƒoī‰ˆ.ī€ƒTheī€ƒfanī€ƒthenī€ƒ
cycles on for 2 minutes, at 10 minute intervals, until
the room temperature is above the set temperature,
atī€ƒwhichī€ƒtimeī€ƒtheī€ƒcompressorī€ƒturnsī€ƒbackī€ƒonī€ƒandī€ƒ
cooling starts.
FOLLOW ME FEATURE:
This feature can ONLY be activated
from the remote control. The
remote control serves as a remote
thermostat allowing for precise
temperature control at its location.
To activate the Follow Me feature, point the remote
control toward the unit and press the FOLLOWī€ƒME
button. The remote displays the actual temperature
at its location. The remote control will send this
signal to the air conditioner every 3 minutes until the
FOLLOWī€ƒME button is pressed again. If the unit does
not receive the Follow Me signal during any 7 minute
interval, the unit will beep to indicate use of the
Follow Me feature has ended. The actual temperature
can be displayed at the unit by pressing the FAN only
mode.ī€ƒWhenī€ƒinī€ƒtheī€ƒCOOLī€ƒmode,ī€ƒtheī€ƒunitī€ƒdisplayī€ƒ
indicates the set temperature.
TO SELECT THE OPERATING MODE:
To choose operating mode, press the MODE
button. Each time you press the button, a mode is
selectedī€ƒinī€ƒaī€ƒī€ƒsequenceī€ƒthatī€ƒgoesī€ƒfromī€ƒAUTO,ī€ƒCOOL,ī€ƒ
DRY and FAN. The indicator light will be illuminated
and remain on once the mode is selected. The unit
will automatically initiate the Energy Saver function
under COOL, DRY, and AUTO (only AUTO-COOLING and
AUTO-FAN) modes.
TO OPERATE AUTO FEATURE:
When you set the air conditioner in AUTO mode, it
will automatically select cooling or fan only operation
depending on what temperature you have selected
and the room temperature. The air conditioner will
automatically control room temperature around the
temperature you set. In this mode, the fan speed
cannot be adjusted. It starts automatically at a speed
according to the room temperature. If the room does
not get too warm, it will stay at a ā€œLowā€ speed.
TO OPERATE FAN ONLY:
Useī€ƒthisī€ƒfunctionī€ƒ(ī€ƒ ī€ƒ)ī€ƒonlyī€ƒwhenī€ƒcoolingī€ƒisī€ƒnotī€ƒ
desired, such as for room air circulation or to exhaust
staleī€ƒair.ī€ƒ(Rememberī€ƒtoī€ƒopenī€ƒtheī€ƒventī€ƒduringī€ƒthisī€ƒ
function,ī€ƒbutī€ƒkeepī€ƒitī€ƒclosedī€ƒduringī€ƒcoolingī€ƒforī€ƒ
maximumī€ƒcoolingī€ƒeī‰‰ciency.)ī€ƒYouī€ƒcanī€ƒchooseī€ƒanyī€ƒ
fan speed you prefer. During this function, the display
will show the actual room temperature, not the set
temperature as in the cooling mode. Temperature
cannotī€ƒbeī€ƒadjustedī€ƒinī€ƒtheī€ƒFANī€ƒonlyī€ƒmode.
TO OPERATE DRY MODE:
In this mode, the air conditioner will reduce air
humidity. If the space is a closed or sealed area,
some degree of cooling will continue.
TIMER: AUTO START/STOP FEATURE:
ā—ī€ƒ Whenī€ƒtheī€ƒunitī€ƒisī€ƒonī€ƒorī€ƒoī‰ˆ,ī€ƒīƒ„rstī€ƒpressī€ƒtheī€ƒ
TIMERī€ƒbutton.ī€ƒTheī€ƒTIMERī€ƒONī€ƒindicatorī€ƒlightī€ƒ
illuminates and indicates the Auto Start program
is initiated.
ā—ī€ƒ Whenī€ƒtheī€ƒtimeī€ƒofī€ƒTIMERī€ƒONī€ƒisī€ƒdisplayed,ī€ƒpressingī€ƒ
the TIMER button again illuminates the TIMER
OFFī€ƒindicatorī€ƒlightī€ƒandī€ƒindicatesī€ƒtheī€ƒAutoī€ƒStopī€ƒ
program is initiated.
ā—ī€ƒ Pressī€ƒorī€ƒholdī€ƒtheī€ƒUPī€ƒorī€ƒDOWNī€ƒbuttonī€ƒtoī€ƒchangeī€ƒ
theī€ƒAutoī€ƒtimeī€ƒbyī€ƒ0.5ī€ƒhourī€ƒincrements,ī€ƒupī€ƒtoī€ƒ10ī€ƒ
hours, then by 1 hour increments, up to 24 hours.
The control will count down the time remaining
until start.
ā—ī€ƒ Theī€ƒselectedī€ƒtimeī€ƒwillī€ƒregisterī€ƒinī€ƒ5ī€ƒsecondsī€ƒandī€ƒ
theī€ƒsystemī€ƒwillī€ƒautomaticallyī€ƒrevertī€ƒbackī€ƒtoī€ƒ
displaying the previous temperature setting or the
roomī€ƒtemperatureī€ƒ(dependingī€ƒonī€ƒwhetherī€ƒtheī€ƒunitī€ƒ
isī€ƒpoweredī€ƒonī€ƒorī€ƒoī‰ˆī€ƒandī€ƒtheī€ƒmodeī€ƒitī€ƒisī€ƒin).
ā—ī€ƒ Turningī€ƒtheī€ƒunitī€ƒONī€ƒorī€ƒOFFī€ƒatī€ƒanyī€ƒtimeī€ƒorī€ƒ
adjustingī€ƒtheī€ƒtimerī€ƒsettingī€ƒtoī€ƒ0.0ī€ƒwillī€ƒcancelī€ƒtheī€ƒ
Autoī€ƒStart/Stopī€ƒprogram.
A NOTE ABOUT THE TIMER:
When you set the timer, the
unitī€ƒwillī€ƒonlyī€ƒgoī€ƒonī€ƒonceī€ƒandī€ƒoī‰ˆī€ƒonce.ī€ƒIfī€ƒyouī€ƒwantī€ƒtheī€ƒ
airī€ƒconditionerī€ƒtoī€ƒcycleī€ƒonī€ƒandī€ƒoī‰ˆī€ƒbasedī€ƒonī€ƒdesiredī€ƒ
room temperature, you do not need to set the timer.
Instead, set your desired temperature and the unit will
cycleī€ƒonī€ƒandī€ƒoī‰ˆī€ƒbasedī€ƒonī€ƒthatī€ƒtemperatureī€ƒsetting.
Light
Flashing
Follow Me
14
DISPLAY:
Shows the set temperature in Ā°F or Ā°C and the Auto-
timer settings. While on FAN only mode, it shows the
room temperature.
TEMP/TIMER
ERROR CODES:
AS - Room Temperature Sensor Error - Unplug the
unitī€ƒandī€ƒplugī€ƒitī€ƒbackī€ƒin.ī€ƒIfī€ƒerrorī€ƒrepeats,ī€ƒcallī€ƒ
Consumer Services at 844-472-2473.
HS - Electric Heating Sensor Error - Unplug the
unitī€ƒandī€ƒplugī€ƒitī€ƒbackī€ƒin.ī€ƒIfī€ƒerrorī€ƒrepeats,ī€ƒcallī€ƒ
Consumer Services at 844-472-2473.
ā—ī€ƒ-ī€ƒī€ƒī€ƒ Evaporator Temperature Sensor Error - Unplug
theī€ƒunitī€ƒandī€ƒplugī€ƒitī€ƒbackī€ƒin.ī€ƒIfī€ƒerrorī€ƒrepeats,ī€ƒcallī€ƒ
Consumer Services at 844-472-2473.
NOTE: If an error code occurs in Fan only mode, the
unitī€ƒwillī€ƒdisplayī€ƒā€œLOā€ī€ƒ(looseī€ƒconnection)ī€ƒorī€ƒā€œHIā€ī€ƒ
(shortī€ƒcircuit).
NOTE:
Ifī€ƒtheī€ƒunitī€ƒbreaksī€ƒoī‰ˆī€ƒunexpectedlyī€ƒdueī€ƒtoī€ƒpowerī€ƒbeingī€ƒ
cut, it will restart with the previous function setting
automatically when the power resumes.
AIR DIRECTIONAL LOUVERS:
Use the 4-way directional louvers to direct the air
īƒ…owī€ƒupī€ƒorī€ƒdownī€ƒandī€ƒleftī€ƒorī€ƒrightī€ƒthroughoutī€ƒtheī€ƒroomī€ƒ
as needed.
Move the center handles from side to side until the
desiredī€ƒLeft/Rightī€ƒdirectionī€ƒisī€ƒobtained.
ADDITIONAL THINGS YOU
SHOULD KNOW:
ā—ī€ƒ Theī€ƒCoolī€ƒcircuitī€ƒhasī€ƒanī€ƒautomaticī€ƒ3ī€ƒminuteī€ƒtime-
delayedī€ƒstartī€ƒifī€ƒtheī€ƒunitī€ƒisī€ƒturnedī€ƒoī‰ˆī€ƒandī€ƒonī€ƒquickly.ī€ƒī€ƒ
Afterī€ƒunitī€ƒisī€ƒturnedī€ƒoī‰ˆ,ī€ƒleaveī€ƒunitī€ƒoī‰ˆī€ƒforī€ƒaī€ƒminimumī€ƒ
ofī€ƒ3ī€ƒminutesī€ƒbeforeī€ƒattemptingī€ƒtoī€ƒturnī€ƒbackī€ƒon.ī€ƒ
This prevents overheating of the compressor
andī€ƒpossibleī€ƒcircuitī€ƒbreakerī€ƒtripping.ī€ƒTheī€ƒfanī€ƒwillī€ƒ
continue to run during this time.
ā—ī€ƒ Theī€ƒcontrolī€ƒisī€ƒcapableī€ƒofī€ƒdisplayingī€ƒtemperatureī€ƒinī€ƒ
degrees Fahrenheit or degrees Celsius. To convert
from one to the other, press and hold the Up and
Downī€ƒTemp/Timerī€ƒbuttonsī€ƒatī€ƒtheī€ƒsameī€ƒtimeī€ƒforī€ƒ
3 seconds.
EXHAUST CONTROL
Close Open
Auto Low
Med High
On
Exhaust
Fan
This Exhaust Control allows the air conditioner to
eitherī€ƒcirculateī€ƒinsideī€ƒairī€ƒ(Closed)ī€ƒorī€ƒexhaustī€ƒairī€ƒtoī€ƒtheī€ƒ
outsideī€ƒ(Open).
The Closed position is used when maximum cooling
is desired. It may also be used for air recirculation
without cooling when the air conditioner is set in any
FAN position.
Theī€ƒOpenī€ƒpositionī€ƒremovesī€ƒstaleī€ƒairī€ƒfromī€ƒtheī€ƒroomī€ƒ
and exhausts it to the outside. Fresh air is drawn in
through normal passages in the home.
Display
Evaporator Temperature Sensor Error
Air Direction (4-way)
15
CARE AND CLEANING
CAUTION
Cleanī€ƒairī€ƒconditionerī€ƒoccasionallyī€ƒtoī€ƒkeepī€ƒitī€ƒlookingī€ƒandī€ƒoperatingī€ƒlikeī€ƒnew.ī€ƒ
Be sure to unplug the unit before cleaning to prevent shock or fire hazards.
AIR FILTER CLEANING
Theī€ƒairī€ƒīƒ„lterī€ƒshouldī€ƒbeī€ƒcleanedī€ƒatī€ƒleastī€ƒeveryī€ƒtwoī€ƒweeksī€ƒorī€ƒas
necessary.ī€ƒTrappedī€ƒparticlesī€ƒinī€ƒtheī€ƒīƒ„lterī€ƒcanī€ƒbuildī€ƒupī€ƒandī€ƒcauseī€ƒan
accumulationī€ƒofī€ƒfrostī€ƒonī€ƒtheī€ƒcoolingī€ƒcoils,ī€ƒreducingī€ƒeī‰‰ciency.
ā—ī€ƒ Graspī€ƒtheī€ƒīƒ„lterī€ƒbyī€ƒtheī€ƒcenterī€ƒandī€ƒpullī€ƒupī€ƒandī€ƒout.
ā—ī€ƒ Washī€ƒtheī€ƒīƒ„lterī€ƒusingī€ƒliquidī€ƒdish-washingī€ƒdetergentī€ƒandī€ƒwarmī€ƒwater.ī€ƒ
Rinseī€ƒīƒ„lterī€ƒthoroughly.
ā—ī€ƒ Gentlyī€ƒshakeī€ƒexcessī€ƒwaterī€ƒfromī€ƒtheī€ƒīƒ„lter.ī€ƒBeī€ƒsureī€ƒtheī€ƒīƒ„lterī€ƒisī€ƒthoroughlyī€ƒ
dry before replacing.
ā—ī€ƒ Asī€ƒanī€ƒalternativeī€ƒtoī€ƒwashingī€ƒtheī€ƒīƒ„lter,ī€ƒvacuumī€ƒtheī€ƒīƒ„lterī€ƒclean.
NOTE: Neverī€ƒuseī€ƒhotī€ƒwaterī€ƒoverī€ƒ104Ā°Fī€ƒ(40Ā°C)ī€ƒtoī€ƒcleanī€ƒtheī€ƒairī€ƒfilter.ī€ƒNeverī€ƒ
attempt to operate the unit without the air filter.
CABINET CLEANING
ā—ī€ƒ Beī€ƒsureī€ƒtoī€ƒunplugī€ƒtheī€ƒairī€ƒconditionerī€ƒtoī€ƒpreventī€ƒshockī€ƒorī€ƒīƒ„reī€ƒhazard.ī€ƒ
The cabinet and front may be dusted with an oil-free cloth or with
aī€ƒclothī€ƒdampenedī€ƒinī€ƒaī€ƒsolutionī€ƒofī€ƒwarmī€ƒwaterī€ƒandī€ƒmildī€ƒliquidī€ƒdish-
washing detergent. Rinse thoroughly and wipe dry.
ā—ī€ƒ Neverī€ƒuseī€ƒharshī€ƒcleaners,ī€ƒwaxī€ƒorī€ƒpolishī€ƒonī€ƒtheī€ƒcabinetī€ƒfront.
ā—ī€ƒ Beī€ƒsureī€ƒtoī€ƒwringī€ƒexcessī€ƒwaterī€ƒfromī€ƒtheī€ƒclothī€ƒbeforeī€ƒwipingī€ƒtheī€ƒ
controls. Excess water in or around the controls may cause damage to
the air conditioner.
ā—ī€ƒ Plugī€ƒinī€ƒairī€ƒconditionerī€ƒafterī€ƒunitī€ƒhasī€ƒdriedī€ƒcompletely.
WINTER STORAGE
If air conditioner will be stored during the winter, remove it carefully from
the window according to the installation instructions. Cover it with plastic
or return it to the original carton.
ALWAYS STORE UNIT IN AN UPRIGHT POSITION AND IN A COOL, DRY LOCATION.
The design and speciļ¬cations are subject to change without prior notice for
product improvement. Consult with the sales agency or manufacturer for details.
16
NOTE
Aī€ƒhighlyī€ƒrecommendedī€ƒtroubleshootī€ƒforī€ƒanyī€ƒissueī€ƒinī€ƒgeneralī€ƒconsistsī€ƒofī€ƒturningī€ƒoī‰ˆī€ƒunitī€ƒandī€ƒunpluggingī€ƒforī€ƒ5ī€ƒ
minutes. It is also recommended to try another wall outlet. For further assistance, contact Consumer Services
at 844-472-2473.
TROUBLESHOOTING
BEFORE CALLING FOR SERVICE, PLEASE REVIEW THE CHART BELOW
ISSUE POSSIBLE CAUSES
AIR CONDITIONER NOT
COOLING ROOM, OR NOT BLOWING
COLD AIR
ā€¢ī€ƒBeī€ƒsureī€ƒunitī€ƒisī€ƒnotī€ƒtooī€ƒlargeī€ƒorī€ƒtooī€ƒsmallī€ƒforī€ƒtheī€ƒareaī€ƒofī€ƒtheī€ƒroom.
ā€¢ī€ƒVerifyī€ƒthatī€ƒallī€ƒdoors,ī€ƒwindows,ī€ƒcurtainsī€ƒandī€ƒanyī€ƒotherī€ƒopeningsī€ƒareī€ƒclosedī€ƒoī‰ˆ.ī€ƒ
Verify nothing is obstructing the front grille of unit, such as curtains, etc.
ā€¢ī€ƒAllowī€ƒenoughī€ƒtimeī€ƒforī€ƒroomī€ƒtoī€ƒcool,ī€ƒespeciallyī€ƒifī€ƒoutsideī€ƒtempī€ƒisī€ƒveryī€ƒhigh.
ā€¢ī€ƒCheckī€ƒthatī€ƒtheī€ƒīƒ„lterī€ƒisī€ƒnotī€ƒdirtyī€ƒandī€ƒlouversī€ƒareī€ƒopenī€ƒallī€ƒtheī€ƒwayī€ƒandī€ƒblowingī€ƒinī€ƒtheī€ƒ
desired direction.
ā€¢ī€ƒCheckī€ƒthatī€ƒunitī€ƒisī€ƒsetī€ƒtoī€ƒCOOLī€ƒmodeī€ƒandī€ƒthatī€ƒtemperatureī€ƒisī€ƒdownī€ƒenoughī€ƒ(butī€ƒ
notī€ƒtooī€ƒlow).
ā€¢ī€ƒIfī€ƒunitī€ƒisī€ƒnearī€ƒaī€ƒheatī€ƒsource,ī€ƒsuchī€ƒasī€ƒaī€ƒstove,ī€ƒetc.,ī€ƒrelocateī€ƒunit.
ā€¢ī€ƒIfī€ƒairī€ƒcomingī€ƒfromī€ƒunitī€ƒisī€ƒcoolī€ƒtoī€ƒtheī€ƒtouch,ī€ƒthenī€ƒunitī€ƒisī€ƒworkingī€ƒproperly;ī€ƒpleaseī€ƒ
doubleī€ƒcheckī€ƒtheī€ƒīƒ„rstī€ƒthreeī€ƒbulletī€ƒpointsī€ƒabove.
ā€¢ī€ƒIfī€ƒusingī€ƒFollowī€ƒMeī€ƒremoteī€ƒfeature,ī€ƒmoveī€ƒremoteī€ƒawayī€ƒfromī€ƒunit.
ā€¢ī€ƒTemperatureī€ƒsensorī€ƒbehindī€ƒairī€ƒīƒ„lterī€ƒtouchingī€ƒcoldī€ƒcoil.ī€ƒTheseī€ƒtwoī€ƒelementsī€ƒshouldī€ƒ
not be touching. Carefully straighten tube away from coil.
ā€¢ī€ƒUnplugī€ƒunitī€ƒforī€ƒatī€ƒleastī€ƒ5ī€ƒminutes.ī€ƒFollowī€ƒResetī€ƒinstructionsī€ƒonī€ƒplug.
AIR CONDITIONER COOLING
BUT ROOM IS TOO WARM - ICE
FORMING ON COOLING COIL
BEHIND DECORATIVE FRONT
ā€¢ī€ƒOutdoorī€ƒtemperatureī€ƒisī€ƒbelowī€ƒ64ĀŗFī€ƒ(18ĀŗC).ī€ƒToī€ƒdefrostī€ƒtheī€ƒcoil,ī€ƒsetī€ƒtoī€ƒFANī€ƒ
only mode.
ā€¢ī€ƒAirī€ƒīƒ„lterī€ƒmayī€ƒbeī€ƒdirty.ī€ƒCleanī€ƒīƒ„lter.ī€ƒReferī€ƒtoī€ƒCareī€ƒandī€ƒCleaningī€ƒsection.ī€ƒToī€ƒdefrost,ī€ƒ
set to FAN only mode.
ā€¢ī€ƒThermostatī€ƒisī€ƒsetī€ƒtooī€ƒcoldī€ƒforī€ƒnight-timeī€ƒcooling.ī€ƒToī€ƒdefrostī€ƒtheī€ƒcoil,ī€ƒsetī€ƒtoī€ƒFANī€ƒ
only mode. Then, set temperature to a higher setting.
AIR CONDITIONER CYCLING ON
AND OFF TOO FREQUENTLY OR
NOT ENOUGH
ā€¢ī€ƒBeī€ƒsureī€ƒunitī€ƒisī€ƒnotī€ƒtooī€ƒlargeī€ƒorī€ƒtooī€ƒsmallī€ƒforī€ƒtheī€ƒareaī€ƒofī€ƒtheī€ƒroom.
ā€¢ī€ƒRemoveī€ƒgrilleī€ƒandī€ƒmakeī€ƒsureī€ƒtheī€ƒtemperatureī€ƒsensorī€ƒisī€ƒnotī€ƒtooī€ƒcloseī€ƒtoī€ƒtheī€ƒcoils.ī€ƒ
These two elements should not be touching. Carefully straighten tube away
from coil.
ā€¢ī€ƒMakeī€ƒsureī€ƒnothingī€ƒisī€ƒblockingī€ƒtheī€ƒgrilleī€ƒorī€ƒsideī€ƒvents.
ā€¢ī€ƒMakeī€ƒsureī€ƒthereī€ƒisī€ƒnoī€ƒdirtī€ƒorī€ƒdebrisī€ƒinsideī€ƒtheī€ƒunitī€ƒorī€ƒonī€ƒtheī€ƒīƒ„lter.
UNIT WILL NOT TURN ON
ā€¢ī€ƒResetī€ƒcircuitī€ƒbreaker.ī€ƒMakeī€ƒsureī€ƒthereī€ƒareī€ƒnotī€ƒtooī€ƒmanyī€ƒitemsī€ƒ(i.e.ī€ƒlamps,ī€ƒTVā€™s,ī€ƒ
etc.)ī€ƒworkingī€ƒoī‰ˆī€ƒtheī€ƒsameī€ƒbreaker.
ā€¢ī€ƒCheckī€ƒplugī€ƒconnection.
ā€¢ī€ƒIfī€ƒplugī€ƒisī€ƒoperatingī€ƒonī€ƒanī€ƒon/oī‰ˆī€ƒswitch,ī€ƒbeī€ƒsureī€ƒthatī€ƒtheī€ƒswitchī€ƒisī€ƒā€˜onā€™.
ā€¢ī€ƒTryī€ƒpluggingī€ƒunitī€ƒintoī€ƒanotherī€ƒoutlet.
ā€¢ī€ƒUnplugī€ƒunitī€ƒforī€ƒatī€ƒleastī€ƒ5ī€ƒminutes.ī€ƒFollowī€ƒResetī€ƒinstructionsī€ƒonī€ƒplug.
UNIT BLOWS FUSES OR POPS
CIRCUIT BREAKER
ā€¢ī€ƒMakeī€ƒsureī€ƒthereī€ƒareī€ƒenoughī€ƒavailableī€ƒampsī€ƒonī€ƒtheī€ƒcircuitī€ƒforī€ƒtheī€ƒairī€ƒconditioner.
ā€¢ī€ƒLargeī€ƒunitsī€ƒwhichī€ƒrunī€ƒonī€ƒaī€ƒ230vī€ƒwillī€ƒrequireī€ƒaī€ƒdedicatedī€ƒ20ī€ƒorī€ƒ30ī€ƒampī€ƒcircuit.
AIR CONDITIONER IS
MAKING NOISES
ā€¢ī€ƒCheckī€ƒtoī€ƒbeī€ƒsureī€ƒtheī€ƒunitī€ƒisī€ƒfreeī€ƒfromī€ƒdebrisī€ƒsuchī€ƒasī€ƒleaves,ī€ƒsticks,ī€ƒetc.ī€ƒVerifyī€ƒ
nothing is obstructing the unit.
ā€¢ī€ƒCheckī€ƒtheī€ƒfanī€ƒbladeī€ƒforī€ƒcracksī€ƒorī€ƒchips.
ā€¢ī€ƒMakeī€ƒsureī€ƒtheī€ƒunitī€ƒisī€ƒproperlyī€ƒandī€ƒsecurelyī€ƒmountedī€ƒinsideī€ƒtheī€ƒwindowī€ƒorī€ƒwall.
ā€¢ī€ƒCleanī€ƒtheī€ƒairī€ƒīƒ„lter.
WATER PUDDLES INSIDE UNIT OR IS
COMING INTO ROOM
ā€¢ī€ƒAdjustī€ƒtheī€ƒslopeī€ƒofī€ƒtheī€ƒunitī€ƒsoī€ƒthatī€ƒitī€ƒdrainsī€ƒdownwardī€ƒtowardī€ƒtheī€ƒexteriorī€ƒofī€ƒtheī€ƒ
home.ī€ƒ(Seeī€ƒInstallationī€ƒInstructions.)
ā€¢ī€ƒMakeī€ƒsureī€ƒthatī€ƒthereī€ƒisī€ƒnoī€ƒdebrisī€ƒblockingī€ƒtheī€ƒdrainageī€ƒareaī€ƒofī€ƒtheī€ƒunit.
WATER DRIPPING OUTSIDE ā€¢ī€ƒUnitī€ƒisī€ƒremovingī€ƒaī€ƒlargeī€ƒquantityī€ƒofī€ƒmoistureī€ƒfromī€ƒaī€ƒhumidī€ƒroom.ī€ƒThisī€ƒisī€ƒnormalī€ƒ
during excessively humid days.
REMOTE SENSING / FOLLOW ME
DEACTIVATING PREMATURELY
ā€¢ī€ƒRemoteī€ƒcontrolī€ƒnotī€ƒlocatedī€ƒwithinī€ƒrange.ī€ƒPlaceī€ƒremoteī€ƒcontrolī€ƒwithinī€ƒ20ī€ƒftī€ƒandī€ƒ
180Āŗ radius of the front of the unit.
ā€¢ī€ƒRemoteī€ƒcontrolī€ƒsignalī€ƒobstructed.ī€ƒRemoveī€ƒobstruction.
Perfect Aire, LLC
5151 Belt Line Rd.
Suite 878
Dallas, TX 75254
Distributed by:
844-4PA-AIRE | 844-472-2473
www.perfectaire.us
WINDOW
AIR CONDITIONER
FOR MODEL:
3PASC10000
Before using your air conditioner, please
read this manual carefully and keep it for
future reference, along with your receipt.
Speciļ¬cation and performance data is subject to change without notice.
Printed in China
PA/User_3PASC10000/10162017
USER MANUAL
/