Heat & Glo See-Through/Pier TRB IFT Install Manual

Category
Fireplaces
Type
Install Manual
1
Heat & Glo • ST-36TRB-IFT, PIER-36TRB-IFT Installation Manual • 2484-980 Rev. H • 11/21
Installation Manual
Installation and Appliance Setup
INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
NOTICE: DO NOT discard this manual!
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
DO NOT store or use gasoline or other am-
mable vapors and liquids in the vicinity of this
or any other appliance.
What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor’s phone. Follow the gas sup-
plier’s instructions.
- If you cannot reach your gas supplier, call
the re department.
Installation and service must be performed
by a qualied installer, service agency, or the
gas supplier.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
Models:
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer’s
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certied kit is used.
ST-36TRB-IFT
PIER-36TRB-IFT
DANGER
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and must be installed for
the protection of children and other at-risk
individuals.
2Heat & Glo • ST-36TRB-IFT, PIER-36TRB-IFT Installation Manual • 2484-980 Rev. H • 11/21
Table of Contents
Installation Standard Work Checklist ....................3
1 Product Specic and Important Safety Information
A. Appliance Certication ............................ 4
B. Glass Specications ..............................4
C. BTU Specications ...............................4
D. High Altitude Installations ..........................4
E. Non-Combustible Materials Specication. . . . . . . . . . . . . . 4
F. Combustible Materials Specication ................. 4
G. Electrical Codes .................................4
H. California ......................................4
I. Requirements for the Commonwealth of Massachusetts . . 5
2 Getting Started
A. Design and Installation Considerations ...............6
B. Good Faith Wall Surface/TV Guidelines ..............6
C. Tools and Supplies Needed ........................6
D. Inspect Appliance and Components ..................7
3 Framing and Clearances
A. Appliance/Decorative Front Dimension Diagrams ....... 8
B. Clearances to Combustibles ......................14
C. Constructing the Appliance Chase ..................17
D. Floor Protection ................................17
4 Termination Location and Vent Information
A. Vent Termination Minimum Clearances ..............18
B. Chimney Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
C. Approved Pipe .................................20
D. Use of Elbows ................................. 21
E. Measuring Standards ............................22
F. Vent Diagrams .................................22
5 Vent Clearances and Framing
A. Pipe Clearances to Combustibles .................. 35
B. Wall Penetration Framing .........................35
C. Ceiling Firestop/Floor Penetration Framing ...........36
D. Install Attic Insulation Shield .......................36
6 Appliance Preparation
A. Vent Collar Preparation ..........................37
B. Securing and Leveling the Appliance ................39
C. Non-Combustible Material Installation ...............40
7 Venting and Chimneys
A. Assemble Vent Sections .........................41
B. Assemble Vent Sections .........................42
C. Assemble Slip Sections (SLP & DVP) ............... 43
D. Secure the Vent Sections .........................43
E. Disassemble Vent Sections ....................... 44
F. Vertical Termination Requirements ..................45
G. Horizontal Termination Requirements ............... 46
8 Electrical Information
A. General Information ............................. 48
B. IntelliFire Touch® Ignition System Wiring .............49
C: Fan (Optional) .................................52
9 Gas Information
A. Fuel Conversion ................................53
B. Gas Pressure ..................................53
C. Gas Connection ................................53
D. High Altitude Installations .........................53
E. Air Shutter Setting .............................. 54
10 Finishing
A. Facing Material .................................55
B. Mantel and Wall Projections .......................56
C. Finishing Material ...............................57
11 Appliance Setup
A. Remove Fixed Glass Assembly .................... 59
B. Remove the Shipping Materials ...................59
C. Clean the Appliance .............................61
D. Glowing Ember and Lava Rock Placement ........... 62
E. Install the Log Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . 63
F. Install Fixed Glass Assembly ......................64
12 Reference Materials
A. Vent Components Diagrams ......................65
B. Accessories ...................................77
= Contains updated information.
Safety Alert Key:
DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.
WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.
CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE: Used to address practices not related to personal injury.
Note: The term “recommend” or “recommended” does not indicate a requirement. It is a best practice suggested by
Hearth & Home Technologies®.
3
Heat & Glo • ST-36TRB-IFT, PIER-36TRB-IFT Installation Manual • 2484-980 Rev. H • 11/21
Installation Standard Work Checklist
Customer:
Lot/Address:
Model (circle one): ST-36TRB-IFT
PIER-36TRB-IFT
Date Installed:
Location of Fireplace:
Installer:
Dealer/Distributor Phone #
Serial #:
Comments: Further description of the issues, who is responsible (Installer/ Builder/ Other Trades, etc) and corrective
action needed _____________________________________________________________________________________
_________________________________________________________________________________________________
_________________________________________________________________________________________________
Comments Communicated to party responsible ____________________ by ______________________on ___________
(Builder / Gen. Contractor/) (Installer) (Date)
Appliance Install YES IF NO, WHY?
Veried that the chase is insulated and sealed. (Pg. 17) ___________________________
Required non-combustible board is installed. (Pg. 40) ___________________________
Veried clearances to combustibles. (Pg. 14-17) ___________________________
Fireplace is leveled and secured. (Pg. 39) ___________________________
Venting/Chimney Section 7 (Pg 41-47)
Venting conguration complies to vent diagrams. ___________________________
Venting installed, locked and secured in place with proper clearance. ___________________________
Firestops installed. ___________________________
Attic insulation shield installed. ___________________________
Exterior wall/Roof ashing installed and sealed. ___________________________
Terminations installed and sealed. ___________________________
Electrical Section 8 (Pg 48-52)
Unswitched power (110-120 VAC) provided to the appliance. ___________________________
Switch wires properly installed. ___________________________
Gas Section 9 (Pg 53-54)
Proper appliance for fuel type. ___________________________
Was a conversion performed? ___________________________
Leak check performed and inlet pressure veried. ___________________________
Veried proper air shutter setting for installation type. ___________________________
Finishing Section 10 (Pg 55-58)
Combustible materials not installed in non-combustible areas. ___________________________
Veried all clearances meet installation manual requirements. ___________________________
Mantels and wall projections comply with installation manual requirements. ___________________________
Appliance Setup Section 11 (Pg 59-64)
All packaging and protective materials removed (inside & outside of appliance). ___________________________
Refractories, logs, media and embers installed correctly. ___________________________
Glass assembly installed and secured. ___________________________
Accessories installed properly. ___________________________
Mesh, doors, or decorative front properly installed. ___________________________
Manual bag and all of its contents are removed from inside/under
the appliance and given to party responsible for use and operation. ___________________________
Started appliance and veried no gas leaks exist. ___________________________
2484-982B 3/19
= Contains updated information.
Hearth & Home Technologies recommends the following:
• Photographing the installation and copying this checklist for your le.
• That this checklist remain visible at all times on the appliance until the installation is complete.
This standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this
installation manual.
WARNING! Risk of Fire or Explosion! Failure to install appliance according to these instructions could
lead to a re or explosion.
ATTENTION INSTALLER:
Follow this Standard Work Checklist
4Heat & Glo • ST-36TRB-IFT, PIER-36TRB-IFT Installation Manual • 2484-980 Rev. H • 11/21
B. Glass Specications
Hearth & Home Technologies appliances manufactured
with tempered glass may be installed in hazardous lo-
cations such as bathtub enclosures as dened by the
Consumer Product Safety Commission (CPSC). The
tempered glass has been tested and certied to the re-
quirements of ANSI Z97.1 and CPSC 16 CFR 1202
(Safety Glazing Certication Council SGCC# 1595 and
1597. Architectural Testing, Inc. Reports 02-31919.01
and 02-31917.01).
This statement is in compliance with CPSC 16 CFR Sec-
tion 1201.5 “Certication and labeling requirements”
which refers to 15 U.S. Code (USC) 2063 stating “…Such
certicate shall accompany the product or shall otherwise
be furnished to any distributor or retailer to whom the
product is delivered.”
Some local building codes require the use of tempered
glass with permanent marking in such locations. Glass
meeting this requirement is available from the factory.
Please contact your dealer or distributor to order.
C. BTU Specications
This product is listed to ANSI standards for “Vented Gas
Fireplace Heaters” and applicable sections of “Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles”, and “Gas Fired Appliances for
Use at High Altitudes”.
A. Appliance Certication
E. Non-Combustible Materials Specication
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in
a Vertical Tube Furnace at 750 ºC shall be considered
non-combustible materials.
F. Combustible Materials Specication
Materials made of or surfaced with wood, compressed pa-
per, plant bers, plastics, or other material that can ignite
and burn, whether ame proofed or not, or plastered or
unplastered shall be considered combustible materials.
G. Electrical Codes
NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with National Electric Code
ANSI/NFPA 70-latest edition or the Canadian Electric
Code CSA C22.1.
A 110-120 VAC circuit for this product must be pro-
tected with ground-fault circuit-interrupter protection,
in compliance with the applicable electrical codes,
when it is installed in locations such as in bathrooms
or near sinks.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
NOTICE: This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.
1 1 Product Specic and Important Safety Information
D. High Altitude Installations
NOTICE: If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility
or authorities having jurisdiction.
When installing above 2000 feet elevation:
In the USA: Reduce input rate 4% for each 1000 feet
above 2000 feet.
In CANADA: Input ratings are certied without a reduction
of input rate for elevations up to 4500 feet (1370 m)
above sea level. Please consult provincial and/or
local authorities having jurisdiction for installations at
elevations above 4500 feet (1370 m).
Check with your local gas utility to determine proper
orice size.
MODELS: ST-36TRB-IFT, PIER-36TRB-IFT
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Direct Vent Heater
STANDARD: CSA / ANSI Z21.88-2019 • CSA 2.33-2019
Models
(U.S. or Canada)
Maximum
Input
BTU/h
Minimum
Input BTU/h
Orice
Size
(DMS)
ST-36TRB-IFT
(NG) (0-2000 FT) 38,000 21,000 32
ST-36TRB-IFT
(Propane) (0-2000 FT) 35,500 20,000 50
PIER-36TRB-IFT
(NG) (0-2000 FT) 38,000 21,000 32
PIER-36TRB-IFT
(Propane) (0-2000 FT) 35,500 20,000 50
H. California
WARNING: This product and the fuels used to
operate this product (liquid propane or natural
gas), and the products of combustion of such fuels, can
expose you to chemicals including benzene, which is
known to the State of California to cause cancer and
reproductive harm. For more information go to: www.
P65Warnings.ca.gov.
5
Heat & Glo • ST-36TRB-IFT, PIER-36TRB-IFT Installation Manual • 2484-980 Rev. H • 11/21
I. Requirements for the Commonwealth of
Massachusetts
For all side wall horizontally vented gas fueled equipment
installed in every dwelling, building or structure used in
whole or in part for residential purposes, including those
owned or operated by the Commonwealth and where the
side wall exhaust vent termination is less than seven (7)
feet above nished grade in the area of the venting, in-
cluding but not limited to decks and porches, the following
requirements shall be satised:
Installation of Carbon Monoxide Detectors
At the time of installation of the side wall horizontal vented
gas fueled equipment, the installing plumber or gas tter
shall observe that a hard wired carbon monoxide detector
with an alarm and battery back-up is installed on the oor
level where the gas equipment is to be installed. In addi-
tion, the installing plumber or gas tter shall observe that
a battery operated or hard wired carbon monoxide detec-
tor with an alarm is installed on each additional level of
the dwelling, building or structure served by the side wall
horizontal vented gas fueled equipment. It shall be the
responsibility of the property owner to secure the services
of qualied licensed professionals for the installation of
hard wired carbon monoxide detectors.
In the event that the side wall horizontally vented gas fu-
eled equipment is installed in a crawl space or an attic,
the hard wired carbon monoxide detector with alarm and
battery back-up may be installed on the next adjacent
oor level.
In the event that the requirements of this subdivision can
not be met at the time of completion of installation, the
owner shall have a period of thirty (30) days to comply
with the above requirements; provided, however, that dur-
ing said thirty (30) day period, a battery operated carbon
monoxide detector with an alarm shall be installed.
Approved Carbon Monoxide Detectors
Each carbon monoxide detector as required in accor-
dance with the above provisions shall comply with NFPA
720 and be ANSI/UL 2034 listed and IAS certied.
Signage
A metal or plastic identication plate shall be permanent-
ly mounted to the exterior of the building at a minimum
height of eight (8) feet above grade directly in line with the
exhaust vent terminal for the horizontally vented gas fu-
eled heating appliance or equipment. The sign shall read,
in print size no less than one-half (1/2) in. in size, “GAS
VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB-
STRUCTIONS”.
Inspection
The state or local gas inspector of the side wall horizon-
tally vented gas fueled equipment shall not approve the
installation unless, upon inspection, the inspector ob-
serves carbon monoxide detectors and signage installed
in accordance with the provisions of 248 CMR 5.08(2)(a)1
through 4.
Exemptions
The following equipment is exempt from 248 CMR 5.08(2)
(a)1 through 4:
The equipment listed in Chapter 10 entitled “Equipment
Not Required To Be Vented” in the most current edition
of NFPA 54 as adopted by the Board; and
• Product Approved side wall horizontally vented gas fu-
eled equipment installed in a room or structure separate
from the dwelling, building or structure used in whole or
in part for residential purposes.
MANUFACTURER REQUIREMENTS
Gas Equipment Venting System Provided
When the manufacturer of Product Approved side wall
horizontally vented gas equipment provides a venting
system design or venting system components with the
equipment, the instructions provided by the manufacturer
for installation of the equipment and the venting system
shall include:
Detailed instructions for the installation of the venting
system design or the venting system components; and
A complete parts list for the venting system design or
venting system.
Gas Equipment Venting System NOT Provided
When the manufacturer of a Product Approved side wall
horizontally vented gas fueled equipment does not pro-
vide the parts for venting the ue gases, but identies
“special venting systems”, the following requirements
shall be satised by the manufacturer:
• The referenced “special venting system” instructions
shall be included with the appliance or equipment in-
stallation instructions; and
• The “special venting systems” shall be Product Ap-
proved by the Board, and the instructions for that sys-
tem shall include a parts list and detailed installation
instructions.
A copy of all installation instructions for all Product Ap-
proved side wall horizontally vented gas fueled equip-
ment, all venting instructions, all parts lists for venting
instructions, and/or all venting design instructions shall
remain with the appliance or equipment at the completion
of the installation.
See Gas Connection section for additional Common-
wealth of Massachusetts requirements.
Note: The following requirements reference various
Massachusetts and national codes not contained in this
document.
6Heat & Glo • ST-36TRB-IFT, PIER-36TRB-IFT Installation Manual • 2484-980 Rev. H • 11/21
2 2 Getting Started
A. Design and Installation Considerations
Heat & Glo direct vent gas appliances are designed to
operate with all combustion air siphoned from outside of
the building and all exhaust gases expelled to the outside.
No additional outside air source is required.
Installation MUST comply with local, regional, state and
national codes and regulations. Consult insurance carrier,
local building inspector, re ocials or authorities having
jurisdiction over restrictions, installation inspection and
permits.
Before installing, determine the following:
• Where the appliance is to be installed.
• The vent system conguration to be used.
• Gas supply piping requirements.
• Electrical wiring requirements.
• Framing and nishing details.
Whether optional accessories—devices such as a fan,
wall switch, or remote control—are desired.
C. Tools and Supplies Needed
Before beginning the installation be sure that the following
tools and building supplies are available.
Tape measure Framing material
Pliers Hammer
Phillips screwdriver Manometer
Gloves Framing square
Voltmeter Electric drill and bits (1/4 in.)
Plumb line Safety glasses
Level Reciprocating saw
Flat blade screwdriver
Non-corrosive leak check solution
1/2 - 3/4 in. length, #6 or #8 Self-drilling screws
Caulking material (300ºF minimum continuous exposure
rating)
One 1/4 in. female connection (for optional fan).
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. For
assistance or additional information, consult a qualied
service technician, service agency or your dealer.
Figure 2.1 Good Faith Wall Surface Temperatures Above Appliance
B. Good Faith Wall Surface/TV Guidelines
NOTICE: Temperatures listed above are taken with a
temperature measuring probe as prescribed by the test
standard used for appliance certication. Temperatures
on walls or mantels taken with an infrared thermometer
may yield increased temperatures of up to 30 degrees or
more depending on the thermometer settings and material
characteristics being measured.
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
6 in.
18 in.
24 in.
30 in.
36 in.
48 in.
TO CEILING
42 in.
12 in.
130°F
APPLIANCE FRONT
FIREPLACE
OPENING
120°F
110°F
100°F
95°F
95°F
90°F
90°F
Installation and service of this appliance should be performed by
qualied personnel. Hearth & Home Technologies recommends
HHT Factory Trained or NFI certied professionals.
7
Heat & Glo • ST-36TRB-IFT, PIER-36TRB-IFT Installation Manual • 2484-980 Rev. H • 11/21
D. Inspect Appliance and Components
Carefully remove the appliance and components from
the packaging.
The vent system components and decorative doors and
fronts may be shipped in separate packages.
• If packaged separately, the log set and appliance grate
must be installed.
Report to your dealer any parts damaged in shipment,
particularly the condition of the glass.
Read all of the instructions before starting the instal-
lation. Follow these instructions carefully during the
installation to ensure maximum safety and benet.
WARNING! Risk of Fire or Explosion! Damaged parts
could impair safe operation. DO NOT install damaged, in-
complete or substitute components. Keep appliance dry.
Hearth & Home Technologies disclaims any responsibility for,
and the warranty will be voided by, the following actions:
Installation and use of any damaged appliance or vent
system component.
Modication of the appliance or vent system.
Installation other than as instructed by Hearth & Home
Technologies.
Improper positioning of the gas logs or the glass door.
Installation and/or use of any component part not approved
by Hearth & Home Technologies.
Any such action may cause a re hazard.
WARNING! Risk of Fire, Explosion or Electric Shock!
DO NOT use this appliance if any part has been under
water. Call a qualied service technician to inspect the
appliance and to replace any part of the control system
and/or gas control which has been under water.
8Heat & Glo • ST-36TRB-IFT, PIER-36TRB-IFT Installation Manual • 2484-980 Rev. H • 11/21
3 3 Framing and Clearances
A. Appliance/Decorative Front Dimension Diagrams
Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5.
Figure 3.1 Appliance Dimensions - ST-36TRB-IFT
B
C
FRONT VIEW RIGHT VIEW
ELECTRICAL
ACCESS
GAS LINE
ACCESS
LEFT VIEW
A
P
J
Ø K
L
Ø K
D
F
GH
M
O
i
N
E
TOP VIEW
Q
Location Inches Millimeters
I1-1/2 38
J 27 686
K 8 203
L 12 305
M9-1/2 241
N 38 965
O34-5/8 880
P24 610
Q38-1/8 968
Location Inches Millimeters
A 36 914
B42-1/2 1080
C24-1/2 622
D33-1/2 851
E 1 25
F 2-1/8 54
G4-1/8 105
H4-1/4 108
9
Heat & Glo • ST-36TRB-IFT, PIER-36TRB-IFT Installation Manual • 2484-980 Rev. H • 11/21
Location Inches Millimeters
I1-1/2 38
J 27 686
K 8 203
L 12 305
M9-1/2 241
N 38 965
O34-5/8 880
P24 610
Q38-1/8 968
Location Inches Millimeters
A37-1/8 943
B40-1/2 1029
C24-1/2 622
D33-1/2 851
E 1 25
F 2-1/8 54
G4-1/8 105
H4-1/4 108
Figure 3.2 Appliance Dimensions - PIER-36TRB-IFT
FRONT VIEW RIGHT VIEW
LEFT VIEW
L
Ø K
M
N
ELECTRICAL
ACCESS J
Ø K
F
GH
i
TOP VIEW
B
A
E
C
D
P
O
Q
GAS LINE
ACCESS
10 Heat & Glo • ST-36TRB-IFT, PIER-36TRB-IFT Installation Manual • 2484-980 Rev. H • 11/21
DECORATIVE FRONT - ARCADIA
(Model: ST-36TRB-IFT, PIER-36TRB-IFT)
Figure 3.3 Decorative Front Dimensions - ARCADIA and CHATEAU
Location ARC-36
Inches Millimeters
A32-7/16 824
B20-1/2 521
C37-1/16 941
D1-3/16 30
E7-5/8 194
F 32-7/8 835
G34-1/4 870
DECORATIVE FRONT - CHATEAU
(Model: ST-36TRB-IFT, PIER-36TRB-IFT)
Location CHA-36
Inches Millimeters
A32-7/16 824
B20-1/2 521
C37-1/16 941
D1-3/16 30
E 7-13-16 198
F 32-7/8 835
G34-1/16 865
B
A
C
E
D
G
F
B
A
C
E
D
G
F
11
Heat & Glo • ST-36TRB-IFT, PIER-36TRB-IFT Installation Manual • 2484-980 Rev. H • 11/21
DECORATIVE FRONT - FOLIO
(Model: ST-36TRB-IFT, PIER-36TRB-IFT)
Figure 3.4 Decorative Front Dimensions - FOLIO and HALSTON
Location FOL-36
Inches Millimeters
A32-3/8 822
B23-1/8 587
C35-13/16 910
D1-3/8 35
E8-1/8 206
F 32-1/16 814
G33-7/16 849
DECORATIVE FRONT - HALSTON
(Model: ST-36TRB-IFT)
Location HAL-36
Inches Millimeters
A32-7/16 824
B21-1/4 540
C37-1/16 941
D1-3/16 30
E7-3/8 187
F 32-7/8 835
G34-1/16 865
C
B
A
G
F
E
D
G
F
D
E
B
A
C
12 Heat & Glo • ST-36TRB-IFT, PIER-36TRB-IFT Installation Manual • 2484-980 Rev. H • 11/21
Figure 3.5 Decorative Front Dimensions - GALLERIA
DECORATIVE FRONT - GALLERIA-6
(Model: ST-36TRB-IFT)
Location GALLERIA-6
Inches Millimeters
A31-9/16 802
B20-7/8 530
C37-1/8 943
D1-1/4 32
E7-3/4 197
F 32-7/8 835
G34-1/16 865
H 15 381
Figure 3.6 End Panel Dimensions - EP-ARC36
EP-ARC36
Location Inches Millimeters
A20-1/8 511
B20-3/8 518
C27-1/16 687
D1-3/8 35
E7-13/16 198
F 32-7/8 835
G34-1/4 870
END PANEL - EP-ARC36
(Model: PIER-36TRB-IFT)
B
A
H
C
E
D
G
F
AB
C
D
E
G
F
13
Heat & Glo • ST-36TRB-IFT, PIER-36TRB-IFT Installation Manual • 2484-980 Rev. H • 11/21
END PANEL - EP-CHA36
(Model: PIER-36TRB-IFT)
END PANEL - EP-FOL36
(Model: PIER-36TRB-IFT)
EP-FOL36
Location Inches Millimeters
A20-1/8 511
B 23 584
C26-13/16 681
D1-3/8 35
E8-1/8 206
F 32-1/16 813
G33-7/16 849
Figure 3.7 End Panel Dimensions - EP-CHA36 and EP-FOL36
EP-CHA36
Location Inches Millimeters
A20-1/16 510
B20-9/16 522
C 27 686
D1-3/16 30
E8-1/8 206
F 32-7/8 835
G34-1/16 865
B
A
C
E
D
G
F
B
A
C
G
F
E
D
14 Heat & Glo • ST-36TRB-IFT, PIER-36TRB-IFT Installation Manual • 2484-980 Rev. H • 11/21
B. Clearances to Combustibles
When selecting a location for the appliance it is important
to consider the required clearances to walls (see Figure
3.8).
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be lo-
cated out of trac and away from furniture and draperies.
NOTICE: Illustrations reect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
Figure 3.8 Appliance Locations
NOTICE: This See-Through appliance is NOT designed
or approved for an indoor/outdoor application.
PIER-36TRB-IFT
ST-36TRB-IFT
36 in.
914 mm
36 in.
914 mm
36 in.
914 mm
36 in.
914 mm
36 in.
914 mm
15
Heat & Glo • ST-36TRB-IFT, PIER-36TRB-IFT Installation Manual • 2484-980 Rev. H • 11/21
Figure 3.9 Clearances to Combustibles - ST-36TRB-IFT
C
A
B
D
F
E
I
G*
H
ST-36TRB-IFT
A B C D E F G* H I
DVP Pipe SLP Pipe
Rough
Opening
(Height)
Rough
Opening
(Depth)
Rough
Opening
(Width)
Clearance
to Ceiling
Combustible
Floor
Combustible
Flooring
Ends of
Appliance
Sides of
Appliance
Rough
Opening
(Width)
Rough
Opening
(Width)
Inches 10 9 38-1/8 23 43 31 0 0 1/2 36
Millimeters 254 229 968 584 1092 787 0 0 13 914
NOTICE: Install appliance on hard metal or wood surfaces
extending full width and depth. DO NOT install directly
on carpeting, vinyl, tile or any combustible material other
than wood.
WARNING! Risk of Fire! Maintain specied air space
clearances to appliance and vent pipe:
Insulation and other materials must be secured to prevent
accidental contact.
• The chase must be properly blocked to prevent blown
insulation or other combustibles from entering and
making contact with replace or chimney.
• Failure to maintain airspace may cause overheating and
a re.
NOTICE: Illustrations reect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
Adjust framing dimensions for interior sheathing (such as sheetrock).
G* For installations with vinyl ooring, see Section 3.D.
16 Heat & Glo • ST-36TRB-IFT, PIER-36TRB-IFT Installation Manual • 2484-980 Rev. H • 11/21
C
A
B
D
Figure 3.10 Clearances to Combustibles - PIER-36TRB-IFT
PIER-36TRB-IFT
A B C D E F G* H I
DVP Pipe SLP Pipe
Rough
Opening
(Height)
Rough
Opening
(Depth)
Rough
Opening
(Width)
Clearance
to Ceiling
Combustible
Floor
Combustible
Flooring
End of
Appliance
Sides of
Appliance
Rough
Opening
(Width)
Rough
Opening
(Width)
Inches 10 9 38-1/8 23 40 31 0 0 1/2 36
Millimeters 254 229 968 584 1016 787 0 0 13 914
NOTICE: Illustrations reect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
G*
F
I
I
E
H
Adjust framing dimensions for interior sheathing (such as sheetrock).
G* For installations with vinyl ooring, see Section 3.D.
17
Heat & Glo • ST-36TRB-IFT, PIER-36TRB-IFT Installation Manual • 2484-980 Rev. H • 11/21
C. Constructing the Appliance Chase
A chase is a vertical box-like structure built to enclose the
gas appliance and/or its vent system. In cooler climates
the vent should be enclosed inside the chase.
NOTICE: Treatment of ceiling restops and wall shield
restops and construction of the chase may vary with the
type of building. These instructions are not substitutes
for the requirements of local building codes. Therefore,
you MUST check local building codes to determine the
requirements to these steps.
NOTICE: When installing a sprinkler head in a replace
chase, it is recommended to use a sprinkler head with a
sprinkler activation temperature classied as Extra High.
Keep sprinkler head away from vent and chimney.
Chases should be constructed in the manner of all out-
side walls of the home to prevent cold air drafting prob-
lems. The chase should not break the outside building
envelope in any manner.
NOTICE: Install appliance on hard metal or wood surfaces
extending full width and depth. DO NOT install directly
on carpeting, vinyl, tile or any combustible material other
than wood.
WARNING! Risk of Fire! Maintain specied air space
clearances to appliance and vent pipe:
Insulation and other materials must be secured to prevent
accidental contact.
• The chase must be properly blocked to prevent blown
insulation or other combustibles from entering and
making contact with replace or chimney.
• Failure to maintain airspace may cause overheating and
a re.
Figure 3.11 Non-Combustible Zone
FACTORY-INSTALLED
NON-COMBUSTIBLE BOARD
= AIR SPACE REQUIRED
3-7/8 in.
Walls, ceiling, base plate and cantilever oor of the chase
should be insulated. Vapor and air inltration barriers
should be installed in the chase as per regional codes for
the rest of the home. Additionally, in regions where cold
air inltration may be an issue, the inside surfaces may be
sheetrocked and taped (or an equivalent method may be
used) to achieve maximum air tightness.
To further prevent drafts, the wall shield and ceiling re-
stops should be caulked with caulk with a minimum of
300ºF continuous exposure rating to seal gaps. Gas
line holes and other openings should be caulked with
caulk with a minimum of 300ºF continuous exposure rating
or stued with unfaced insulation. If the appliance is being
installed on a cement surface, a layer of plywood may be
placed underneath to prevent conducting cold up into the
room.
D. Floor Protection
Vinyl Flooring
Vinyl ooring is sensitive to heat. Hearth and Home
Technologies does not recommend adhesive based vinyl
ooring due to thermal expansion. Floating-style ooring
can be used, but will reach temperatures up to to 110 °F
in a room with ambient temperature of 70 °F. Consult
ooring specications to ensure compatibility.
18 Heat & Glo • ST-36TRB-IFT, PIER-36TRB-IFT Installation Manual • 2484-980 Rev. H • 11/21
A. Vent Termination Minimum Clearances
Roof Pitch H (Min.) Ft.
Flat to 6/12...........................................................1.0*
Over 6/12 to 7/12 .................................................1.25*
Over 7/12 to 8/12 .................................................1.5*
Over 8/12 to 9/12 .................................................2.0*
Over 9/12 to 10/12 ...............................................2.5*
Over 10/12 to 11/12 .............................................3.25
Over 11/12 to 12/12 .............................................4.0
Over 12/12 to 14/12 .............................................5.0
Over 14/12 to 16/12 .............................................6.0
Over 16/12 to 18/12 .............................................7.0
Over 18/12 to 20/12 .............................................7.5
Over 20/12 to 21/12 .............................................8.0
Figure 4.1 Minimum Height From Roof to Lowest Discharge
Opening
HORIZONTAL
OVERHANG
VERTICAL
WALL
GAS DIRECT VENT
TERMINATION CAP
12
X
ROOF PITCH
IS X/ 12
LOWEST
DISCHARGE
OPENING
2 FT.
MIN.
20 INCHES MIN.
H (MIN.) - MINIMUM HEIGHT FROM ROOF
TO LOWEST DISCHARGE OPENING
4 4 Termination Location and Vent Information
Fire Risk.
Maintain vent clearance to combustibles as
specied.
DO NOT pack air space with insulation or other
materials.
Failure to keep insulation or other materials away
from vent pipe could cause overheating and re.
WARNING
Figure 4.2 Staggered Termination Caps
Gas, Wood or Fuel Oil
Termination Cap
B
Gas
Termination
Cap **
A *
*If using decorative cap cover(s), this distance may need to be
increased. Refer to the installation instructions supplied with the
decorative cap cover.
**
A B
6 in. (minimum) up to 20 in.
152 mm/508 mm
18 in. minimum
457 mm
20 in. and over 0 in. minimum
In a staggered installation with both gas and wood or fuel oil
terminations, the wood or fuel oil termination cap must be
higher than the gas termination cap.
* H minimum may vary depending on regional snowfall.
Refer to local codes.
19
Heat & Glo • ST-36TRB-IFT, PIER-36TRB-IFT Installation Manual • 2484-980 Rev. H • 11/21
Figure 4.3 Minimum Clearances for Termination
O
N
P
R
Q
X= AIR SUPPLY INLET
A = 12 inches.................clearances above grade, veranda,
porch, deck or balcony
B = 12 inches.................clearance to window or door that may
be opened, or to permanently closed
window
C = 18 inches.................clearance below unventilated sot
18 inches.................clearance below ventilated sot
30 inches .................clearance below vinyl soffits and
electrical service
D = 6 inches...................clearance to outside corner
E = 6 inches...................clearance to inside corner
F = 3 ft. (Canada) ..........not to be installed above a gas me-
ter/regulator assembly within 3 feet
horizontally from the center-line of the
regulator
G = 3 ft ...........................clearance to gas service regulator
vent outlet
H = 12 inches.................clearance to non-mechanical (unpow-
ered) air supply inlet, combustion air
inlet or direct-vent termination
i = 3 ft. (U.S.A.)
6 ft. (Canada) ...........clearance to a mechanical (powered)
air supply inlet
All mechanical air intakes within 10 feet of a termination cap
must be a minimum of 3 feet below termination.
J = 7 ft. ......................... On public property: clearance above
paved sidewalk or a paved driveway.
A vent shall not terminate directly above a sidewalk or paved
driveway which is located between two single family dwellings
and serves both dwellings.
V= VENT TERMINAL
= AREA WHERE TERMINAL IS NOT PERMITTED
C
JB
D
B
F
B
A
E
V
V
V
V
V
V
M
H or i
V
G
X
VH
A
VV
H
Electrical
Service
V
K
V K
V
L
C
V
N = 6 inches ........... non-vinyl sidewalls
12 inches ......... vinyl sidewalls
O = 18 inches ......... non-vinyl sot and overhang
42 inches ......... vinyl sot and overhang
P = 8 ft.
QMIN RMAX
1 cap 3 feet 2 x Q ACTUAL
2 caps 6 feet 1 x Q ACTUAL
3 caps 9 feet 2/3 x Q ACTUAL
4 caps 12 feet 1/2 x Q ACTUAL
QMIN = # termination caps x 3 RMAX = (2 / # termination caps) x QACTUAL
Covered Alcove Applications
(Spaces open only on one side and with an overhang)
Measure horizontal clearances from this surface.
Measure vertical clearances from this surface.
CLEARANCE = 6 IN.
CAUTION! Risk of Burns! Termination caps are HOT,
consider proximity to doors, trac areas or where people
may pass or gather (sidewalk, deck, patio, etc.). Listed cap
shields available. Contact your dealer.
Local codes or regulations may require different
clearances.
Vent system termination is NOT permitted in screened
porches.
Vent system termination is permitted in porch areas with
two or more sides open.
Hearth & Home Technologies assumes no responsibility
for the improper performance of the appliance when the
venting system does not meet these requirements.
Vinyl protection kits are suggested for use with vinyl siding.
M = 18 inches .................... clearance under veranda, porch, deck,
balcony or overhang
42 inches ................vinyl or composite overhang
Permitted when veranda, porch, deck or balcony is fully open
on a minimum of 2 sides beneath the oor.
K = 6 inches................. clearance from sides of electrical
service
L = 12 inches................ clearance above electrical service
Location of the vent termination must not interfere with access to the
electrical service.
B. Chimney Diagram
20 Heat & Glo • ST-36TRB-IFT, PIER-36TRB-IFT Installation Manual • 2484-980 Rev. H • 11/21
C. Approved Pipe
This appliance is approved for use with Hearth & Home
Technologies DVP or SLP venting systems. Refer to Sec-
tion 12.A for vent component information and dimensions.
Only use listed decorative termination caps/shrouds with
Hearth & Home Technologies approved venting systems.
DO NOT mix pipe, ttings or joining methods from dier-
ent manufacturers.
The pipe is tested to be run inside an enclosed wall.
There is no requirement for inspection openings at each
joint within the wall.
WARNING! Risk of Fire or Asphyxiation. This appli-
ance requires a separate vent. DO NOT vent to a pipe
serving a separate solid fuel burning appliance.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77

Heat & Glo See-Through/Pier TRB IFT Install Manual

Category
Fireplaces
Type
Install Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI