SELECTING A MOUNTING LOCATION
1. Give consideration to the weight of the unit when operating (filled with water). Operating weights
of High Flow CSR Systems are:
• TwinSystem-45lbs(20.2kg)
• TripleSystem-47lbs(21.2kg)
• QuadSystem-49lbs(22.2kg)
• QuadPlusSystem-49lbs(21.2kg)+separatesurge/storagetank@60lbs(27.2kg)
2. Thelocationshouldallowfor(Seegures1-8):
• Minimumclearanceof2
1
2"underthecartridge(s)soitcanbeloweredforremovaland
replacement.
• Adequatespacefor“in”and“out”waterlineconnections.Benearadrainforushingandnear
a110VoutletiftheoptionalEverguard
LowPressureAlarmisused.
• AdditionalmountingandoorspacefortheseparateSR-XFeederandsurge/storagetank
(Quad
Plus).
OPERATING SPECIFICATIONS*
Combined Model Name
Replacement
Cartridge
Flow Rate Capacity
HighFlowCSRTwin-MC MC 3.3gpm(12.5lpm) 18,000gal.(68,000L)
HighFlowCSRTwin-MC
2
MC
2
3.3gpm(12.5lpm) 18,000gal.(68,000L)
HighFlowCSRTwin-XC XC 3.3gpm(12.5lpm) 18,000gal.(68,000L)
HighFlowCSRTwin-XC
2
XC
2
3.3gpm(12.5lpm) 18,000gal.(68,000L)
HighFlowCSRTwin-4CB5 4CB5 3.3gpm(12.5lpm) 12,000gal.(45,400L)
HighFlowCSRTwin-7CB5 7CB5 5.0gpm(18.9lpm) 20,000gal.(75,700L)
HighFlowCSRTriple-MC MC 5.0gpm(18.9lpm) 27,000gal.(102,000L)
HighFlowCSRTriple-MC
2
MC
2
5.0gpm(18.9lpm) 27,000gal.(102,000L)
HighFlowCSRTriple-XC XC 5.0gpm(18.9lpm) 36,000gal.(136,000L)
HighFlowCSRTriple-XC
2
XC
2
5.0gpm(18.9lpm) 36,000gal.(136,000L)
HighFlowCSRTriple-4CB5 4CB5 5.0gpm(18.9lpm) 18,000gal.(68,000L)
HighFlowCSRTriple-7CB5 7CB5 7.5gpm(28.5lpm) 30,000gal.(113,550L)
HighFlowCSRQuad-MC MC 6.6gpm(25.2lpm) 36,000gal.(136,000L)
HighFlowCSRQuad-MC
2
MC
2
6.6gpm(25.2lpm) 36,000gal.(136,000L)
HighFlowCSRQuadPlus-XC XC 6.6gpm(25.2lpm) 48,000gal.(181,600L)
HighFlowCSRQuadPlus-XC
2
XC
2
6.6gpm(25.2lpm) 48,000gal.(181,600L)
*Forindividualcartridgespecications,refertocartridgeliterature.
Temperature: 35-100°F(2-38°C)
Pressure: 10-125psi(0.7-8.6bar),non-shock
For cold water use only.
INSTALLATION
1. Usethepredrilledmountingholesinthemanifoldbracketasguides.Markanddrillanchorholes.
Mountsecurely.SeeFigures5-8.
2. Shutoffpowertoequipment.IfsystemisaHighFlowCSRQuadPlus(separateSR-XFeederand
surge/storagetank
),proceedtostep3b.
3a. ConnectoutletportsofHighFlowsystemtoequipmentservedpertheinstructionsbelow.Always
useNSFapprovedpipedopeorTeontapeatallconnections.Useabackupwrenchonallttings
while connecting to avoid stress on the system components.
• ThecrossttingbeforetheSR-XFeederhasathreadedoutletontop.Connectaminimum1/2"
I.D.linefromthisoutlettofountainbeverageequipment.
• Thecrossttinghasaushingvalveinstalledonthebottom.Connecttubingtotheushingvalve
andruntodrain.Note:Somemunicipalplumbingcodesandgoodsanitarypracticesrequirean
air gap at the drain termination point.
Figure1–Twin
EV3112-78RevEAP08
Installation and Operation Guide
High Flow CSR Filter Systems
Figure2–Triple
Figure4–QuadPlus
Figure3–Quad
ManufacturedbyEverpure
• ConnecttheoutletoftheSR-XFeedertotheicemachinemake-upwater(notcondenserwater)
lineandcoffeebrewingequipment.Proceedtostep4.
3b.ForHighFlowCSRQuadPlusSystem,connectoutlettoequipmentservedpertheinstructionsbe-
low.AlwaysuseaNSFapprovedpipedopeorTeontapeatallconnections.Useabackupwrench
on all fittings while connecting to avoid stress on the system components.
• LocateandmounttheseparateSR-XFeederbetweentheHighFlowCSRsystemandtheice
machine.Make-upwater(notcondenserwater)lineandcoffeebrewingequipment.
• Ateettingislocatedinthesystemheaderbeforethesurgetankisolationandushingvalve.
Usingminimum1/2"I.D.line,connecttheoutletofthisteetothefountainbeverageandremote
SR-XFeederline.Important: Install a tee in this service water line to separate the fountain
water feed from the ice machine/coffee brewer water feed.
In Massachusetts, a backflow preventer is required for this installation.
• Connectonebranchoftheservicewaterteetothefountainbeverageequipment.Connectthe
otherbranchoftheteetotheinletoftheSR-XFeeder.ConnecttheoutletoftheSR-XFeederto
theicemachinemake-upwater(notcondenserwater)lineandcoffeebrewingequipment.
• Thesurgetankisolationandushingvalveislocatedattheendofthesystemheader.Using
ttingsandhoseprovided,connectonebranchofthevalvetothesurge/storagetank.Connect
ahosefromtheother(ushing)branchandruntodrain.Note: Some municipal plumbing codes
and good sanitary practices require an air gap at the drain termination point.
4. Thesurge/storagetankispre-pressurizedto20psi.Checkpressureandadjustasnecessary.
5. Installamanualshut-offvalveleadingtothesystemforservicingandconnectminimum1/2"I.D.
(3/4"forquad)waterlinetothesysteminlet.
6. TheoptionalEverguard
LowPressureAlarm(LPA)consistsofapressureswitch,audible/visual
alarmboxandapoweradapter.Itisdesignedtodetectaxedlowpressure(approx.20psi)
conditionasanindicationoflossofsystemoutletpressureeitherduetoanintentionalshut-down
orexcessfoulingofthewaterlters,thusindicatingtheneedforltercartridgechange-out.Ifthe
systemisequippedwiththeLPA,followthesesteps:
• Determinelocationofaconvenient110VACoutlettoplugintheLPApoweradapter.
• Removetheprotectiverubbercapfromthepressureswitchinstalledinthesystemheader
assembly.InsertthewiresfromtheLPAunitthroughthecapandconnectthemtotheterminals
onthepressureswitch.Eitherwirecanbeconnectedtoeitherterminal.Replacethecap.
• PlugtheLPApoweradapterintoanoutlet.Theaudiblealarmshouldactivate.Pushthereset
switch to silence.
• UnplugtheLPAunit.
7. Shutoffthesysteminletvalvelocatedontheinletoftheprelterhead.
8. Checktobesuretheo-ringontheprelterhousingissufcientlylubricated.Useagoodgradeof
siliconelubricant,ifneeded.PositiontheEC210preltercartridgeonguideseatinthebottomof
thebowl.Thenthreadthebowlintotheheadbyhand.Useasumpwrenchtosnugthebowlonto
the head.
9. InstallonlygenuineEverpure™carbonltercartridge(s)intothelterhead(s)followingdirections
onthecartridgelabelorasshownintheCartridgeChangeillustrations.InstalltheSS-10Scale
InhibitorcartridgeintotheSR-Xhousing.
10.Turnoninletwatertotheltersystemandcheckforleaks.
11.Opentheushingvalveandushthecartridge(s)byrunningwaterthroughatfullforceforve
minutes.Thiswillsetthelteringmediaandpurgeanyairandnes,insuringmaximumlterlife.
See illustrations.
12.Afterushing,closetheushingvalve,turnonpowertoequipmentandplugtheLPA(ifso
equipped)intotheelectricaloutlet.Thesystemisreadyforoperation.
Figure5–HighFlowCSRTwin
25.80"
ICE MACHINE/
COFFEE
OUTLET
3/4" FNPT
INLET
3/4" FNPT
FOUNTAIN
OUTLET
3/4" FNPT
25.59"
Figure6–HighFlowCSRTriple
25.59"
30"
INLET
3/4" FNPT
ICE MACHINE/
COFFEE
OUTLET
3/4" FNPT
FOUNTAIN
OUTLET
3/4" FNPT
Figure8–HighFlowCSRQuadPlus
29.69"
OUTLET
3/4" FNPT
INLET
3/4" FNPT
ICE MACHINE/
COFFEE
OUTLET
3/4" FNPT
INLET
3/4" FNPT
INSERT TEE FITTING.
ONE OUTLET TO FOUNTAIN,
ONE OUTLET TO SRX.
31.38"
Figure7–HighFlowCSRQuad
34"
INLET
3/4" FNPT
ICE MACHINE/
COFFEE
OUTLET
3/4" FNPT
FOUNTAIN
OUTLET
3/4" FNPT
25.69"
Checkforcompliancewithstateandlocallawsand
regulations.TheCommonwealthofMassachusetts
PlumbingCode248CMRshallbeadheredto.Consultyour
locallicensedplumberforinstallationofthissystem.Do
notusewithwaterthatismicrobiologicallyunsafeorof
unknownqualitywithoutadequatedisinfectionbeforeor
after the system. Systems certified for cyst reduction may
beusedondisinfectedwatersthatmaycontainlterable
cysts.
FLUSHING
For maximum life, all carbon filter cartridges must be flushed for five minutes at full flow before use. ALL
NEW CARTRIDGES MUST BE FLUSHED AFTER EACH CARTRIDGE CHANGE BEFORE BEING PUT INTO SERVICE!
Ifthecartridgesarenew,havebeenproperlyushedandbothneedleandfollowerregisterinadequatepressure,or
theLPAissounding,youmaybeexperiencinginadequatewaterpressureorsomerestrictionmayexistintheinlet
waterline.Ineithercase,theincomingwaterpressuremustbeimprovedtoreceiveoptimumlterlife.
COMPLETECARTRIDGECHANGEINSTRUCTIONSCANBEFOUNDONTHEFILTERCARTRIDGELABEL.
Not for residential use. For food service applications only.
CARTRIDGE CHANGE PROCEDURE
E-Series Prelter Cartridge Change
1. Shutoffpowertoequipment.Shut
off inlet water ahead of system.
2. Pushredreliefvalve.Unscrew
bowl.Removepreltercartridge.
3. Cleanbowlwithlteredwateronly;
NOSPECIALCLEANERS.
4. Feelheado-ring.Ifdry,lubricate
withhighqualitysiliconelubricant.
5. Installnewpreltercartridgein
bowl.Handtightenbowlontohead.
6. Turnonwater.Turnonpowerto
equipment.
Everpure Carbon Filter Cartridge
Change
1. Shutoffpowertoequipment.Shut
off inlet water ahead of system.
2. Openushingvalvetorelieve
pressure.
3. Hold head firmly and push upward.
Turncartridgetoleftuntilitstops.
4. Pullcartridgedownwardandoutof
head.
5. Holdheadrmly.Aligncartridge
lugwithlabel.Insertnewcartridge
firmly into head.
6. Turncartridgeright90˚until
rotation stops.
7. Repeatsteps3-6forremaining
cartridges.
Flushing
8. Withushingvalvefullyopen,open
inlet water at full force for five
minutes.Closeushingvalve.
9. Turnonpowertoequipment
PRESSURE GAUGES
Low Inlet
Pressure
Adequate Inlet
Pressure
Low Outlet
Pressure
Adequate Outlet
Pressure
SR-X Feeder Cartridge Change
1. Shutoffpowertoequipment.Shut
off inlet water ahead of system.
2. Pressredpressurereliefbuttonon
head.
3. Unscrewbowl.
4. Removeoldcartridge.
5. Feelbowlo-ring;ifdry,lubricate
withsiliconelubricant.
6. InstallnewSS-10cartridgeinto
head.
7. Handtightenbowlintohead.
8. Turnonwater.
9. Pressredpressurereliefbutton
until water comes out of valve port.
10.Turnonpowertoequipment.
For installations in Massachusetts, the Commonwealth of Massachusetts Plumbing Code 248 CMR shall be adhered to. Consult your licensed
plumber for installation of the system. This system and its installation must comply with state and local regulations.
CARTRIDGE CHANGE DETERMINATION
Replacethepreltercartridgewheneveritbecomesexcessivelydirty(observedvisuallyorbyowrestriction).Followthechangeinstructionsprovidedwith
thecartridge.Replacecarbonltercartridgeswhencapacityisreachedorwhenowbecomesinadequate,butatleastannually.Allcarbonltercartridges
onmultiplecartridgesystemsshouldbechangedatthesametime.ChangetheSS-10cartridgewhenproductlevelinthecartridgedropsbelow1/2"from
thebottomofthebowl.
ThesystempressuregaugeoroptionalEverguard
LowPressureAlarm(LPA)providesaquick,simplemeansofdeterminingwhentheltercartridge(s)
shouldbechecked.Installedonthesystemoutletmanifold,thegaugeorLPAcanbeusedtomonitorbothdynamic(owing)andstatic(line)pressure.The
cartridge(s)shouldbechangedwhenthepressuregaugeisintheredareawhileequipmentisinoperation,andyettheneedleshowsadequatelinepressure
betweencycles.Observetheneedleduringthenextequipmentoncycle.Iftheneedleregistersadequatepressure,itcanbeassumedthatthetemporary
low-pressureconditionwascausedbyabriefpowerfailureorotherincomingpressuredisruption.Ifthelowpressureconditionisnotduetoanexternal
condition,check/changetheprelterrst.Ifthelowpressureconditionisstillnotcorrected,changethecarbonltercartridges.
For sales, replacement components, and service, contact your Everpure dealer or:
Everpure, LLC: 1040MuireldDrive•HanoverPark,Illinois60133•800.323.7873
In Europe: Toekomstlaan30•B-2200Herentals,Belguim
In Japan: HashimotoMNBldg.7F•3-25-1HashimotoSagamihara-Shi•Kanagawa229-1103,Japan
PrintedinU.S.A. EV3112-78RevEAP08
Technical Service
800.942.1153
www.everpure.com
LIMITED WARRANTY
COMMERCIAL WATER TREATMENT EQUIPMENT
Youhavejustpurchasedoneofthenestwatertreatmentunitsmade.AsanexpressionofourcondenceinEverpureproducts,thisproductiswarrantedagainstdefectsin
materialandworkmanshiptotheoriginalend-userwheninstalledinaccordancewithEverpurespecications.Thewarrantyperiodcommencesfromthedateofpurchase
and is administered as follows:
For a period of ONE YEAR Replaceable elements (i.e., filter & water treatment cartridges)*
For a period of FIVE YEARS The entire system (excluding replaceable elements)
*This is for material & workmanship, not filter or water treatment cartridge life.
TheunitmustbeusedinoperatingconditionsthatconformtoEverpure’srecommendeddesignguidelines.Thiswarrantywillnotapplyiftheunithasbeenmodied,repaired
oralteredbysomeonenotauthorizedbyEverpure.
If a part described above is found defective within the specified period, you should notify Everpure technical service at the phone number listed below. Any part
found defective within the terms of this warranty will be repaired or replaced (at Everpure’s discretion) by your local dealer or Everpure technical service. You
pay only freight from our factory and local dealer charges. Any repaired or replaced warranty item will be incorporated under the original warranty terms of the
existing system.
Wearenotresponsiblefordamagecausedbyaccident,re,ood,freezing,ActofGod,misuse,misapplication,neglect,oxidizingagents(suchaschlorine,ozone,
chloraminesandotherrelatedcomponents),alteration,installationoroperationcontrarytoourprintedinstructions,orbytheuseofaccessoriesorcomponentswhichdonot
meetEverpure’sspecications.RefertothespecicationssectionintheInstallationandOperatingmanualforapprovedapplicationparameters.
Ourproductperformancespecicationsarefurnishedwitheachwatertreatmentunit.TOTHEEXTENTPERMITTEDBYLAW,EVERPUREDISCLAIMSALLIMPLIEDWARRANTIES,
INCLUDINGWITHOUTLIMITATIONWARRANTIESOFMERCHANTABILITYANDFITNESSFORPARTICULARPURPOSE;TOTHEEXTENTREQUIREDBYLAW,ANYSUCHIMPLIED
WARRANTIESARELIMITEDINDURATIONTOTHEPERIODSPECIFIEDABOVEFORTHEENTIREWATERTREATMENTUNIT.Asamanufacturer,wedonotknowthecharacteristics
ofyourwatersupplyorthepurposeforwhichyouarepurchasingthisproduct.Thequalityofwatersuppliesmayvaryseasonallyoroveraperiodoftime,andyourwater
usageratemayvaryaswell.Watercharacteristicscanalsodifferconsiderablyifthisproductismovedtoanewlocation.Forthesereasons,weassumenoliabilityforthe
determinationoftheproperequipmentnecessarytomeetyourrequirements,andwedonotauthorizeotherstoassumesuchobligationsforus.Further,weassumeno
liabilityandextendnowarranties,expressorimplied,fortheuseofthisproductwithanon-potablewatersourceorawatersourcewhichdoesnotmeettheconditionsfor
usedescribedintheowner’sguideorperformancedatasheetforthisproduct.OUROBLIGATIONSUNDERTHISWARRANTYARELIMITEDTOTHEREPAIRORREPLACEMENT
(ATEVERPURE’SDISCRETION)OFTHEFAILEDPARTSOFTHEWATERTREATMENTUNIT,ANDWEASSUMENOLIABILITYWHATSOEVERFORDIRECT,INDIRECT,INCIDENTAL,
CONSEQUENTIAL,SPECIAL,GENERALOROTHERDAMAGES.
Somestatesdonotallowtheexclusionofimpliedwarrantiesorlimitationsonhowlonganimpliedwarrantylasts,sotheabovelimitationmaynotapplytoyou.Similarly,
somestatesdonotallowtheexclusionofincidentalorconsequentialdamages,sotheabovelimitationorexclusionmaynotapplytoyou.Thiswarrantygivesyouspecic
legalrights,andyoumayalsohaveotherrightswhichvaryfromstatetostate.ConsultyourtelephonedirectoryforyourlocalindependentlyoperatedEverpuredealer,or
writeEverpureforwarrantyandserviceinformation.
REPLACEMENT PARTS
ContactyourlocalEverpuredealerforltercartridgesorsystemreplace-
ment parts.
Description Part Number
Inlet/outletpressuregauge EV3114-09
Inlet/ushingvalve EV3114-07
O-ringforprelterorSR-X EV3112-40
Prelterbowl EV3112-38
SR-Xbowl EV3112-39
LPApressureswitch EV3016-41
Wrench EV3112-41
System Tested and Certied by NSF International against
NSF/ANSI Standards 42 and 53 for the reduction of:
Standard No. 42 —
Aesthetic Effects
Chemical Reduction
Taste and Odor
Chlorine
Mechanical Filtration
Particulate Class I: 99.2% reduction of particles
one-half micron and larger in size
Standard No. 53 —
Health Effects
Mechanical Filtration
Turbidity (MC, MC
2
only)
Cyst (MC, MC
2
, XC, XC
2
only)
Asbestos (MC, MC
2
only)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Everpure EV3112 User manual

Category
Water filters
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI