American Standard 2000.100.002 is a Centerset Lavatory Faucet with Pop-up Drain. This faucet is designed to be easy to install, with a Speed Connect drain that requires fewer parts and installs in less time. The faucet also features a Hot Limit Safety Stop that reduces the risk of accidental scalding, and a durable construction that is sure to last for years to come. With its stylish design and convenient features, the American Standard 2000.100.002 is the perfect choice for any bathroom.

American Standard 2000.100.002 is a Centerset Lavatory Faucet with Pop-up Drain. This faucet is designed to be easy to install, with a Speed Connect drain that requires fewer parts and installs in less time. The faucet also features a Hot Limit Safety Stop that reduces the risk of accidental scalding, and a durable construction that is sure to last for years to come. With its stylish design and convenient features, the American Standard 2000.100.002 is the perfect choice for any bathroom.

COLLAR ON
MOUNTING NUT
8
DOWN
WHITE FOAM
GASKET
NOT VISIBLE
DRAIN
FLANGE
Fig. A. Fig. B.
1
M 9 6 8 7 6 0 R e v . 1 . 3
M 9 6 8 7 6 0 R e v . 1 . 3
M 9 6 8 7 6 0 R e v . 1 . 3 M 9 6 8 7 6 0 R e v . 1 . 3
Certified to comply with ANSI A112.18.1
Installation
Instructions
Centerset Lavatory Faucet with
Speed Connect™ Drain
Adjustable Wrench Screwdriver Channel Locks
Recommended tools
CHECK OPERATION OF POP-UP
8
MAKE WATER SUPPLY AND WASTE CONNECTIONS
9
2
SERVICE
TEST INSTALLED FITTING
With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate HANDLE (1) to flush water lines thoroughly.
Replace AERATOR (3).
5
2
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (4) and fill lavatory with water.
Check that DRAIN STOPPER (5) makes a good seal
and retains water in SINK. If DRAIN STOPPER (5)
does not seal properly, please refer to Troubleshooting
section in these instructions.
Release POP-UP KNOB (4) down and check all drain
connections and "P" trap for leaks. Tighten
if necessary.
12
11
10
“P” TRAP
WASTE
OUTLET
Speed Connect™ Drain
Troubleshooting Guide
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled
as “Cam” and “Cam Cap” in the illustration. Fig. B.
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.
The Stopper can now be removed by lifting it out of the Drain. Fig. F.
CAM
CAM CAP
CABLE ADJUSTMENT PROCEDURE
If sink does not hold water even though Stopper is in the “down” position:
• Follow CABLE ADJUSTMENT PROCEDURE.
If Stopper does not raise up fully or sink drains too slowly:
• Follow CABLE ADJUSTMENT PROCEDURE.
If you need to remove the Stopper:
• Follow STOPPER REMOVAL PROCEDURE.
If you would like the ability to remove your Stopper simply by lifting it out of the drain:
Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.
Fig. B.
REMOVE
CAM
Fig. E.
Fig. F.
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as
“Cam” in the illustration. Fig. B.
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the
Stopper should be in the UP position. Fig. B, C.
Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the
Drain Body Connection (2) and hand-tighten. Fig. A.
STOPPER REMOVAL PROCEDURE
STOPPER INSTALLATION PROCEDURE
Locked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. G.
To install the stopper in “Locked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the rear of the
Sink and the American Standard logo is facing front. Rotate
Stopper slightly if necessary so that the Stopper slides all the
way down.Fig. G.
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
Troubling Shooting Guide to complete installation. Stopper will be
in “Locked” mode and not be removable.
Unlocked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. H.
To install the stopper in “Unlocked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the front of the
Sink and the American Standard logo is facing rear. Rotate Stopper
slightly if necessary so that the Stopper slides all the way down.
Fig. H.
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
“Troublingshooting Guide” to complete installation. Stopper will be
in “Unlocked” mode and removable.
Fig. J. Fig. K.
INSTALL
CAM CAP
CAM
INSTALL CAM
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be
removed) or “Unlock” Mode (Stopper is removable).
Unlocked Mode
LOOP TOWARD
FRONT OF SINK
180˚
LOGO
DRAIN
Fig. H.
Locked Mode
(Vandal Proof)
LOGO
DRAIN
Fig. G.
LOOP TOWARD
REAR OF SINK
2
1
RE-ATTACH
DISCONNECT
Fig. D.
REMOVE
CAM CAP
Thread CABLE CONNECTOR (1) clockwise
onto DRAIN BODY CONNECTION (2) and
hand tighten. Fig. A.
Your new POP-UP DRAIN installation is
now complete. Fig. B.
Note: Tailpeice on pop-up drain is 1-1/4” O.D.
Fig. B.
Fig. A.
ATTACH CABLE CONNECTOR
7
2
1
Fig. B.
1-1/4” O.D.
3
Fig. C.
STOPPER
1
DOWN
M961747-YYY0A
LIFT ROD
072574-0070A
EXTENSION ROD
066116-YYY0A
DRAIN STOPPER
M961711-0070A
TAILPIECE INSERT
070847-0070A
CLIP
066118-0070A
PIVOT ROD KIT
M953450-YYY0A
COMPLETE
DRAIN ASSEMBLY
070532-0040A
TAILPIECE
066117-YYY0A
2" FLANGE KIT
POP-UP DRAIN ASSEMBLY
BEFORE 01/07
1
3
4
5 6
2000.10X
2000.16X
Center -Set Lavatory Faucet
with Pop-up Drain
MODEL NUMBERS
2000.10X
2000.16X
T M
T M
© A m e r i c a n S t a n d a r d I n c . 2 0 0 2
Replace the "YYY" with
appropriate finish code
CHROME
WHITE
BONE
WHITE/CHROME
BLACK NICKEL
POLISHED BRASS
SATIN
SATIN/POL. BRASS
CHROME/POL. BRASS
002
020
021
025
062
099
295
297
299
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1-800 442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
Pr oduct n ames li sted he rein ar e tra de marks o f Ame ri can S ta ndard I nc.
IN MEXICO 01-800-839-12-00
2
1
5
2
4
1
Remove HANDLE (1), CAP (2), SCREWS (3) and
CARTRIDGE (4). Clean inlets and MANIFOLD (5).
Reassemble CARTRIDGE (4), alternately tightening
SCREWS (3). Replace CAP (2) and HANDLE (1).
Check flow.
If faucet drips, operate handle several times from
"off" to "on". Do not apply excessive force.
Clogged CARTRIDGE inlets may cause reduced flow
in "full on" hot or cold. To clean inlets, first turn off
water supply, then:
3
ADJUSTMENT WHEN
WATER IS TOO HOT
ADJUSTMENT WHEN
WATER IS TOO COLD
PRY RED RING FORWARD
AND ROTATE COUNTER-
CLOCKWISE ONE CLICK
PRY RED RING FORWARD
AND ROTATE CLOCKWISE
POINTER ON
HOT LIMIT STOP
"A"
"A"
"B"
"B"
RED RING HOT
LIMIT SAFETY
STOP
0
1
2
3
4
5
6
By restricting handle rotation and limiting the amount of hot
water allowed to mix with the cold, the HOT LIMIT SAFETY
STOP reduces risk of accidental scalding. To set the maximum
hot water temperature of your faucets, all you need
to do is adjust the setting on the HOT LIMIT SAFETY STOP.
Remove necessary trim parts. Use a flat blade screwdriver or
pull forward with your fingers to rotate red HOT LIMIT SAFETY
STOP. Follow Step "A" or "B" to adjust max./min. discharge
temperature. "0" being the hottest to "7" the coldest
temperature setting.
HOT LIMIT SAFETY STOP
IF FAUCET DRIPS
Fig. A.
M962430-0070A
CAM ASSEMBLY
M952430-0070A
CABLE ASSEMBLY
M952425-YYY0A
DRAIN ASSEMBLY
M962456-YYY0A
STOPPER
ASSEMBLY
M962457-YYY0A
FLANGE
ASSEMBLY
M962458-0070A
DRAIN MOUNTING KIT
A919661-0020A
TAILPIECE
M922872-0070A
CAM SEAT INSERT
M913207-0070A
TAILPIECE INSERT
M919660-0020A
6” TAILPIECE
(NOT INCLUDED
WITH FAUCET)
Thread FLANGE (1) counter-clockwise and remove
FLANGE (1) and FOAM GASKET (2) from drain
body. Fig. A.
Thread LOCKNUT (3) clock-wise to bottom of
drain body. Push GASKET (4) down against
LOCKNUT (3). Fig. B.
POP-UP DRAIN
Tighten TAILPIECE (4) on DRAIN BODY before
installing DRAIN BODY. Fig. B.
6
2
4
3
2
TIGHTEN LOCKNUT
1
REMOVE FLANGE
Remove CLEAR PLASTIC COVER (1).
Remove CARDBOARD SPACER (2) from under
DRAIN POP-UP (3).
2
2
3
3
1
2
4
3
1
9
1
Tighten LOCKNUT (1) firmly with Adjustable
Wrench or Channel Locks.
INSTALL DRAIN FROM
BELOW FIXTURE
5
From under side of SINK
install DRAIN BODY (1) up
through drain outlet.
Note: No plumber’s putty
or caulk is required.
The CABLE ATTACHMENT
POINT (2) must face towards
the rear of the SINK.
Install FOAM GASKET (3) and
FLANGE (4) onto drain body
from above SINK and tighten
FLANGE (4) firmly.
4
Fig. A. Fig. B.
Fig. A. Fig. B.
POP-UP KNOB (1) must be fully down. Fig. B.
FLANGE GASKET AND POP-UP KNOB
Check DRAIN FLANGE in SINK to ensure that
WHITE FOAM GASKET (3) is fully compressed
and not visible. Fig. A.
DRAIN
BODY
4
2
DRAIN
OUTLET
1
3
4
1
INSTALL FAUCET
Turn off hot and cold water
supplies before beginning.
CAUTION
GROOVE
(FAUCET
BASE)
6
4
7
5
Seat SEAL (1) into under side of FAUCET BASE (2).
Feed FAUCET SUPPLIES (3), MOUNTING STUD (4) and DRAIN
CABLE ASSEMBLY (8) through ESCUTCHEON (9) (optional) and the
mounting hole of lavatory or mounting surface. Fig. A.
From below, push GASKET (7) and RETAINING WASHER (5) onto
MOUNTING STUD (4). Secure Faucet with MOUNTING NUT (6),
pulling faucet to front of sink, so SUPPLIES (3) rests against
mounting hole. Before final tightening, make sure collar on
MOUNTING NUT (6) is seated into RETAINING WASHER (5).
Fig.B.
Adjust Faucet so that it is centered. Tighten MOUNTING NUT (6)
to complete faucet mounting.
REAR
OF SINK
Operate LIFT KNOB (1) to verify that STOPPER (2) opens and
closes.
Note: If STOPPER (2) does not open and close properly then
refer to the “troubleshooting section” of these instructions.
M 9 6 8 7 6 0 R e v . 1 . 3 M 9 6 8 7 6 0 R e v . 1 . 3 M 9 6 8 7 6 0 R e v . 1 . 3
M961741-YYY0A
HANDLE KIT
030126-0070A
HANDLE INDEX SET
A907086-YYY0A
CAP
918633-0070A
CARTRIDGE SCREWS
023529-0070A
CARTRIDGE KIT
M962492-0070A
MOUNTING KIT
911708-0070A
SEAL
M907671-YYY0A
ESCUTCHEON
M961745-0070A
MANIFOLD KIT
M962525-YYY0A
LIFT ROD
A922869-YYY0A
AERATOR
1
APPROX. 20"
2
COLD
HOT
3/8" COMPRESSION
RED
BAND
BLUE
BAND
Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies.
Connection on fitting supplies are 3/8" compression. Connect
left SUPPLY (1) to Hot (Marked with a Red Band) and right supply
to COLD (2) wall supply.
Faucet supplies are 20" long from faucet base.
Note: If additional supply length is required, installer must
purchase additional parts separately.
Important: If SUPPLY HOSES (1, 2) are to long, loop as
illustrated to avoid kinking.
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to
waste outlet.
1
4
7
Fig. B.
Fig. A.
Congratulations on purchasing your American Standard
faucet with Speed Connect drain, a feature found only on
American Standard faucets.
*Your new American Standard faucet is designed to work only with the Speed Connect drain. Heplful tips for
removing your current drain can be found in the Troubleshooting section of these instructions.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Speed Connect™ Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS:
COLLAR ON
MOUNTING NUT
8
DOWN
WHITE FOAM
GASKET
NOT VISIBLE
DRAIN
FLANGE
Fig. A. Fig. B.
1
M 9 6 8 7 6 0 R e v . 1 . 3
M 9 6 8 7 6 0 R e v . 1 . 3
M 9 6 8 7 6 0 R e v . 1 . 3 M 9 6 8 7 6 0 R e v . 1 . 3
Certified to comply with ANSI A112.18.1
Installation
Instructions
Centerset Lavatory Faucet with
Speed Connect™ Drain
Adjustable Wrench Screwdriver Channel Locks
Recommended tools
CHECK OPERATION OF POP-UP
8
MAKE WATER SUPPLY AND WASTE CONNECTIONS
9
2
SERVICE
TEST INSTALLED FITTING
With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate HANDLE (1) to flush water lines thoroughly.
Replace AERATOR (3).
5
2
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (4) and fill lavatory with water.
Check that DRAIN STOPPER (5) makes a good seal
and retains water in SINK. If DRAIN STOPPER (5)
does not seal properly, please refer to Troubleshooting
section in these instructions.
Release POP-UP KNOB (4) down and check all drain
connections and "P" trap for leaks. Tighten
if necessary.
12
11
10
“P” TRAP
WASTE
OUTLET
Speed Connect™ Drain
Troubleshooting Guide
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled
as “Cam” and “Cam Cap” in the illustration. Fig. B.
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.
The Stopper can now be removed by lifting it out of the Drain. Fig. F.
CAM
CAM CAP
CABLE ADJUSTMENT PROCEDURE
If sink does not hold water even though Stopper is in the “down” position:
• Follow CABLE ADJUSTMENT PROCEDURE.
If Stopper does not raise up fully or sink drains too slowly:
• Follow CABLE ADJUSTMENT PROCEDURE.
If you need to remove the Stopper:
• Follow STOPPER REMOVAL PROCEDURE.
If you would like the ability to remove your Stopper simply by lifting it out of the drain:
Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.
Fig. B.
REMOVE
CAM
Fig. E.
Fig. F.
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as
“Cam” in the illustration. Fig. B.
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the
Stopper should be in the UP position. Fig. B, C.
Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the
Drain Body Connection (2) and hand-tighten. Fig. A.
STOPPER REMOVAL PROCEDURE
STOPPER INSTALLATION PROCEDURE
Locked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. G.
To install the stopper in “Locked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the rear of the
Sink and the American Standard logo is facing front. Rotate
Stopper slightly if necessary so that the Stopper slides all the
way down.Fig. G.
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
Troubling Shooting Guide to complete installation. Stopper will be
in “Locked” mode and not be removable.
Unlocked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. H.
To install the stopper in “Unlocked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the front of the
Sink and the American Standard logo is facing rear. Rotate Stopper
slightly if necessary so that the Stopper slides all the way down.
Fig. H.
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
“Troublingshooting Guide” to complete installation. Stopper will be
in “Unlocked” mode and removable.
Fig. J. Fig. K.
INSTALL
CAM CAP
CAM
INSTALL CAM
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be
removed) or “Unlock” Mode (Stopper is removable).
Unlocked Mode
LOOP TOWARD
FRONT OF SINK
180˚
LOGO
DRAIN
Fig. H.
Locked Mode
(Vandal Proof)
LOGO
DRAIN
Fig. G.
LOOP TOWARD
REAR OF SINK
2
1
RE-ATTACH
DISCONNECT
Fig. D.
REMOVE
CAM CAP
Thread CABLE CONNECTOR (1) clockwise
onto DRAIN BODY CONNECTION (2) and
hand tighten. Fig. A.
Your new POP-UP DRAIN installation is
now complete. Fig. B.
Note: Tailpeice on pop-up drain is 1-1/4” O.D.
Fig. B.
Fig. A.
ATTACH CABLE CONNECTOR
7
2
1
Fig. B.
1-1/4” O.D.
3
Fig. C.
STOPPER
1
DOWN
M961747-YYY0A
LIFT ROD
072574-0070A
EXTENSION ROD
066116-YYY0A
DRAIN STOPPER
M961711-0070A
TAILPIECE INSERT
070847-0070A
CLIP
066118-0070A
PIVOT ROD KIT
M953450-YYY0A
COMPLETE
DRAIN ASSEMBLY
070532-0040A
TAILPIECE
066117-YYY0A
2" FLANGE KIT
POP-UP DRAIN ASSEMBLY
BEFORE 01/07
1
3
4
5 6
2000.10X
2000.16X
Center -Set Lavatory Faucet
with Pop-up Drain
MODEL NUMBERS
2000.10X
2000.16X
T M
T M
© A m e r i c a n S t a n d a r d I n c . 2 0 0 2
Replace the "YYY" with
appropriate finish code
CHROME
WHITE
BONE
WHITE/CHROME
BLACK NICKEL
POLISHED BRASS
SATIN
SATIN/POL. BRASS
CHROME/POL. BRASS
002
020
021
025
062
099
295
297
299
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1-800 442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
Pr oduct n ames li sted he rein ar e tra de marks o f Ame ri can S ta ndard I nc.
IN MEXICO 01-800-839-12-00
2
1
5
2
4
1
Remove HANDLE (1), CAP (2), SCREWS (3) and
CARTRIDGE (4). Clean inlets and MANIFOLD (5).
Reassemble CARTRIDGE (4), alternately tightening
SCREWS (3). Replace CAP (2) and HANDLE (1).
Check flow.
If faucet drips, operate handle several times from
"off" to "on". Do not apply excessive force.
Clogged CARTRIDGE inlets may cause reduced flow
in "full on" hot or cold. To clean inlets, first turn off
water supply, then:
3
ADJUSTMENT WHEN
WATER IS TOO HOT
ADJUSTMENT WHEN
WATER IS TOO COLD
PRY RED RING FORWARD
AND ROTATE COUNTER-
CLOCKWISE ONE CLICK
PRY RED RING FORWARD
AND ROTATE CLOCKWISE
POINTER ON
HOT LIMIT STOP
"A"
"A"
"B"
"B"
RED RING HOT
LIMIT SAFETY
STOP
0
1
2
3
4
5
6
By restricting handle rotation and limiting the amount of hot
water allowed to mix with the cold, the HOT LIMIT SAFETY
STOP reduces risk of accidental scalding. To set the maximum
hot water temperature of your faucets, all you need
to do is adjust the setting on the HOT LIMIT SAFETY STOP.
Remove necessary trim parts. Use a flat blade screwdriver or
pull forward with your fingers to rotate red HOT LIMIT SAFETY
STOP. Follow Step "A" or "B" to adjust max./min. discharge
temperature. "0" being the hottest to "7" the coldest
temperature setting.
HOT LIMIT SAFETY STOP
IF FAUCET DRIPS
Fig. A.
M962430-0070A
CAM ASSEMBLY
M952430-0070A
CABLE ASSEMBLY
M952425-YYY0A
DRAIN ASSEMBLY
M962456-YYY0A
STOPPER
ASSEMBLY
M962457-YYY0A
FLANGE
ASSEMBLY
M962458-0070A
DRAIN MOUNTING KIT
A919661-0020A
TAILPIECE
M922872-0070A
CAM SEAT INSERT
M913207-0070A
TAILPIECE INSERT
M919660-0020A
6” TAILPIECE
(NOT INCLUDED
WITH FAUCET)
Thread FLANGE (1) counter-clockwise and remove
FLANGE (1) and FOAM GASKET (2) from drain
body. Fig. A.
Thread LOCKNUT (3) clock-wise to bottom of
drain body. Push GASKET (4) down against
LOCKNUT (3). Fig. B.
POP-UP DRAIN
Tighten TAILPIECE (4) on DRAIN BODY before
installing DRAIN BODY. Fig. B.
6
2
4
3
2
TIGHTEN LOCKNUT
REMOVE FLANGE
Remove CLEAR PLASTIC COVER (1).
Remove CARDBOARD SPACER (2) from under
DRAIN POP-UP (3).
2
2
3
3
1
2
4
3
1
9
1
Tighten LOCKNUT (1) firmly with Adjustable
Wrench or Channel Locks.
INSTALL DRAIN FROM
BELOW FIXTURE
5
From under side of SINK
install DRAIN BODY (1) up
through drain outlet.
Note: No plumber’s putty
or caulk is required.
The CABLE ATTACHMENT
POINT (2) must face towards
the rear of the SINK.
Install FOAM GASKET (3) and
FLANGE (4) onto drain body
from above SINK and tighten
FLANGE (4) firmly.
4
Fig. A. Fig. B.
Fig. A. Fig. B.
POP-UP KNOB (1) must be fully down. Fig. B.
FLANGE GASKET AND POP-UP KNOB
Check DRAIN FLANGE in SINK to ensure that
WHITE FOAM GASKET (3) is fully compressed
and not visible. Fig. A.
DRAIN
BODY
4
2
DRAIN
OUTLET
1
3
4
1
INSTALL FAUCET
Turn off hot and cold water
supplies before beginning.
CAUTION
GROOVE
(FAUCET
BASE)
6
4
7
5
Seat SEAL (1) into under side of FAUCET BASE (2).
Feed FAUCET SUPPLIES (3), MOUNTING STUD (4) and DRAIN
CABLE ASSEMBLY (8) through ESCUTCHEON (9) (optional) and the
mounting hole of lavatory or mounting surface. Fig. A.
From below, push GASKET (7) and RETAINING WASHER (5) onto
MOUNTING STUD (4). Secure Faucet with MOUNTING NUT (6),
pulling faucet to front of sink, so SUPPLIES (3) rests against
mounting hole. Before final tightening, make sure collar on
MOUNTING NUT (6) is seated into RETAINING WASHER (5).
Fig.B.
Adjust Faucet so that it is centered. Tighten MOUNTING NUT (6)
to complete faucet mounting.
REAR
OF SINK
Operate LIFT KNOB (1) to verify that STOPPER (2) opens and
closes.
Note: If STOPPER (2) does not open and close properly then
refer to the “troubleshooting section” of these instructions.
M 9 6 8 7 6 0 R e v . 1 . 3 M 9 6 8 7 6 0 R e v . 1 . 3 M 9 6 8 7 6 0 R e v . 1 . 3
M961741-YYY0A
HANDLE KIT
030126-0070A
HANDLE INDEX SET
A907086-YYY0A
CAP
918633-0070A
CARTRIDGE SCREWS
023529-0070A
CARTRIDGE KIT
M962492-0070A
MOUNTING KIT
911708-0070A
SEAL
M907671-YYY0A
ESCUTCHEON
M961745-0070A
MANIFOLD KIT
M962525-YYY0A
LIFT ROD
A922869-YYY0A
AERATOR
1
APPROX. 20"
2
COLD
HOT
3/8" COMPRESSION
RED
BAND
BLUE
BAND
Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies.
Connection on fitting supplies are 3/8" compression. Connect
left SUPPLY (1) to Hot (Marked with a Red Band) and right supply
to COLD (2) wall supply.
Faucet supplies are 20" long from faucet base.
Note: If additional supply length is required, installer must
purchase additional parts separately.
Important: If SUPPLY HOSES (1, 2) are to long, loop as
illustrated to avoid kinking.
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to
waste outlet.
1
4
7
Fig. B.
Fig. A.
Congratulations on purchasing your American Standard
faucet with Speed Connect drain, a feature found only on
American Standard faucets.
*Your new American Standard faucet is designed to work only with the Speed Connect drain. Heplful tips for
removing your current drain can be found in the Troubleshooting section of these instructions.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Speed Connect™ Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS:
COLLAR ON
MOUNTING NUT
8
DOWN
WHITE FOAM
GASKET
NOT VISIBLE
DRAIN
FLANGE
Fig. A. Fig. B.
1
M 9 6 8 7 6 0 R e v . 1 . 3
M 9 6 8 7 6 0 R e v . 1 . 3
M 9 6 8 7 6 0 R e v . 1 . 3 M 9 6 8 7 6 0 R e v . 1 . 3
Certified to comply with ANSI A112.18.1
Installation
Instructions
Centerset Lavatory Faucet with
Speed Connect™ Drain
Adjustable Wrench Screwdriver Channel Locks
Recommended tools
CHECK OPERATION OF POP-UP
8
MAKE WATER SUPPLY AND WASTE CONNECTIONS
9
2
SERVICE
TEST INSTALLED FITTING
With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate HANDLE (1) to flush water lines thoroughly.
Replace AERATOR (3).
5
2
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (4) and fill lavatory with water.
Check that DRAIN STOPPER (5) makes a good seal
and retains water in SINK. If DRAIN STOPPER (5)
does not seal properly, please refer to Troubleshooting
section in these instructions.
Release POP-UP KNOB (4) down and check all drain
connections and "P" trap for leaks. Tighten
if necessary.
12
11
10
“P” TRAP
WASTE
OUTLET
Speed Connect™ Drain
Troubleshooting Guide
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled
as “Cam” and “Cam Cap” in the illustration. Fig. B.
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.
The Stopper can now be removed by lifting it out of the Drain. Fig. F.
CAM
CAM CAP
CABLE ADJUSTMENT PROCEDURE
If sink does not hold water even though Stopper is in the “down” position:
• Follow CABLE ADJUSTMENT PROCEDURE.
If Stopper does not raise up fully or sink drains too slowly:
• Follow CABLE ADJUSTMENT PROCEDURE.
If you need to remove the Stopper:
• Follow STOPPER REMOVAL PROCEDURE.
If you would like the ability to remove your Stopper simply by lifting it out of the drain:
Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.
Fig. B.
REMOVE
CAM
Fig. E.
Fig. F.
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as
“Cam” in the illustration. Fig. B.
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the
Stopper should be in the UP position. Fig. B, C.
Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the
Drain Body Connection (2) and hand-tighten. Fig. A.
STOPPER REMOVAL PROCEDURE
STOPPER INSTALLATION PROCEDURE
Locked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. G.
To install the stopper in “Locked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the rear of the
Sink and the American Standard logo is facing front. Rotate
Stopper slightly if necessary so that the Stopper slides all the
way down.Fig. G.
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
Troubling Shooting Guide to complete installation. Stopper will be
in “Locked” mode and not be removable.
Unlocked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. H.
To install the stopper in “Unlocked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the front of the
Sink and the American Standard logo is facing rear. Rotate Stopper
slightly if necessary so that the Stopper slides all the way down.
Fig. H.
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
“Troublingshooting Guide” to complete installation. Stopper will be
in “Unlocked” mode and removable.
Fig. J. Fig. K.
INSTALL
CAM CAP
CAM
INSTALL CAM
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be
removed) or “Unlock” Mode (Stopper is removable).
Unlocked Mode
LOOP TOWARD
FRONT OF SINK
180˚
LOGO
DRAIN
Fig. H.
Locked Mode
(Vandal Proof)
LOGO
DRAIN
Fig. G.
LOOP TOWARD
REAR OF SINK
2
1
RE-ATTACH
DISCONNECT
Fig. D.
REMOVE
CAM CAP
Thread CABLE CONNECTOR (1) clockwise
onto DRAIN BODY CONNECTION (2) and
hand tighten. Fig. A.
Your new POP-UP DRAIN installation is
now complete. Fig. B.
Note: Tailpeice on pop-up drain is 1-1/4” O.D.
Fig. B.
Fig. A.
ATTACH CABLE CONNECTOR
7
2
1
Fig. B.
1-1/4” O.D.
3
Fig. C.
STOPPER
1
DOWN
M961747-YYY0A
LIFT ROD
072574-0070A
EXTENSION ROD
066116-YYY0A
DRAIN STOPPER
M961711-0070A
TAILPIECE INSERT
070847-0070A
CLIP
066118-0070A
PIVOT ROD KIT
M953450-YYY0A
COMPLETE
DRAIN ASSEMBLY
070532-0040A
TAILPIECE
066117-YYY0A
2" FLANGE KIT
POP-UP DRAIN ASSEMBLY
BEFORE 01/07
1
3
4
5 6
2000.10X
2000.16X
Center -Set Lavatory Faucet
with Pop-up Drain
MODEL NUMBERS
2000.10X
2000.16X
T M
T M
© A m e r i c a n S t a n d a r d I n c . 2 0 0 2
Replace the "YYY" with
appropriate finish code
CHROME
WHITE
BONE
WHITE/CHROME
BLACK NICKEL
POLISHED BRASS
SATIN
SATIN/POL. BRASS
CHROME/POL. BRASS
002
020
021
025
062
099
295
297
299
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1-800 442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
Pr oduct n ames li sted he rein ar e tra de marks o f Ame ri can S ta ndard I nc.
IN MEXICO 01-800-839-12-00
2
1
5
2
4
1
Remove HANDLE (1), CAP (2), SCREWS (3) and
CARTRIDGE (4). Clean inlets and MANIFOLD (5).
Reassemble CARTRIDGE (4), alternately tightening
SCREWS (3). Replace CAP (2) and HANDLE (1).
Check flow.
If faucet drips, operate handle several times from
"off" to "on". Do not apply excessive force.
Clogged CARTRIDGE inlets may cause reduced flow
in "full on" hot or cold. To clean inlets, first turn off
water supply, then:
3
ADJUSTMENT WHEN
WATER IS TOO HOT
ADJUSTMENT WHEN
WATER IS TOO COLD
PRY RED RING FORWARD
AND ROTATE COUNTER-
CLOCKWISE ONE CLICK
PRY RED RING FORWARD
AND ROTATE CLOCKWISE
POINTER ON
HOT LIMIT STOP
"A"
"A"
"B"
"B"
RED RING HOT
LIMIT SAFETY
STOP
0
1
2
3
4
5
6
By restricting handle rotation and limiting the amount of hot
water allowed to mix with the cold, the HOT LIMIT SAFETY
STOP reduces risk of accidental scalding. To set the maximum
hot water temperature of your faucets, all you need
to do is adjust the setting on the HOT LIMIT SAFETY STOP.
Remove necessary trim parts. Use a flat blade screwdriver or
pull forward with your fingers to rotate red HOT LIMIT SAFETY
STOP. Follow Step "A" or "B" to adjust max./min. discharge
temperature. "0" being the hottest to "7" the coldest
temperature setting.
HOT LIMIT SAFETY STOP
IF FAUCET DRIPS
Fig. A.
M962430-0070A
CAM ASSEMBLY
M952430-0070A
CABLE ASSEMBLY
M952425-YYY0A
DRAIN ASSEMBLY
M962456-YYY0A
STOPPER
ASSEMBLY
M962457-YYY0A
FLANGE
ASSEMBLY
M962458-0070A
DRAIN MOUNTING KIT
A919661-0020A
TAILPIECE
M922872-0070A
CAM SEAT INSERT
M913207-0070A
TAILPIECE INSERT
M919660-0020A
6” TAILPIECE
(NOT INCLUDED
WITH FAUCET)
Thread FLANGE (1) counter-clockwise and remove
FLANGE (1) and FOAM GASKET (2) from drain
body. Fig. A.
Thread LOCKNUT (3) clock-wise to bottom of
drain body. Push GASKET (4) down against
LOCKNUT (3). Fig. B.
POP-UP DRAIN
Tighten TAILPIECE (4) on DRAIN BODY before
installing DRAIN BODY. Fig. B.
6
2
4
3
2
TIGHTEN LOCKNUT
1
REMOVE FLANGE
Remove CLEAR PLASTIC COVER (1).
Remove CARDBOARD SPACER (2) from under
DRAIN POP-UP (3).
2
2
3
3
1
2
4
3
1
9
1
Tighten LOCKNUT (1) firmly with Adjustable
Wrench or Channel Locks.
INSTALL DRAIN FROM
BELOW FIXTURE
5
From under side of SINK
install DRAIN BODY (1) up
through drain outlet.
Note: No plumber’s putty
or caulk is required.
The CABLE ATTACHMENT
POINT (2) must face towards
the rear of the SINK.
Install FOAM GASKET (3) and
FLANGE (4) onto drain body
from above SINK and tighten
FLANGE (4) firmly.
4
Fig. A. Fig. B.
Fig. A. Fig. B.
POP-UP KNOB (1) must be fully down. Fig. B.
FLANGE GASKET AND POP-UP KNOB
Check DRAIN FLANGE in SINK to ensure that
WHITE FOAM GASKET (3) is fully compressed
and not visible. Fig. A.
DRAIN
BODY
4
2
DRAIN
OUTLET
1
3
4
1
INSTALL FAUCET
Turn off hot and cold water
supplies before beginning.
CAUTION
GROOVE
(FAUCET
BASE)
6
4
7
5
Seat SEAL (1) into under side of FAUCET BASE (2).
Feed FAUCET SUPPLIES (3), MOUNTING STUD (4) and DRAIN
CABLE ASSEMBLY (8) through ESCUTCHEON (9) (optional) and the
mounting hole of lavatory or mounting surface. Fig. A.
From below, push GASKET (7) and RETAINING WASHER (5) onto
MOUNTING STUD (4). Secure Faucet with MOUNTING NUT (6),
pulling faucet to front of sink, so SUPPLIES (3) rests against
mounting hole. Before final tightening, make sure collar on
MOUNTING NUT (6) is seated into RETAINING WASHER (5).
Fig.B.
Adjust Faucet so that it is centered. Tighten MOUNTING NUT (6)
to complete faucet mounting.
REAR
OF SINK
Operate LIFT KNOB (1) to verify that STOPPER (2) opens and
closes.
Note: If STOPPER (2) does not open and close properly then
refer to the “troubleshooting section” of these instructions.
M 9 6 8 7 6 0 R e v . 1 . 3 M 9 6 8 7 6 0 R e v . 1 . 3 M 9 6 8 7 6 0 R e v . 1 . 3
M961741-YYY0A
HANDLE KIT
030126-0070A
HANDLE INDEX SET
A907086-YYY0A
CAP
918633-0070A
CARTRIDGE SCREWS
023529-0070A
CARTRIDGE KIT
M962492-0070A
MOUNTING KIT
911708-0070A
SEAL
M907671-YYY0A
ESCUTCHEON
M961745-0070A
MANIFOLD KIT
M962525-YYY0A
LIFT ROD
A922869-YYY0A
AERATOR
1
APPROX. 20"
2
COLD
HOT
3/8" COMPRESSION
RED
BAND
BLUE
BAND
Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies.
Connection on fitting supplies are 3/8" compression. Connect
left SUPPLY (1) to Hot (Marked with a Red Band) and right supply
to COLD (2) wall supply.
Faucet supplies are 20" long from faucet base.
Note: If additional supply length is required, installer must
purchase additional parts separately.
Important: If SUPPLY HOSES (1, 2) are to long, loop as
illustrated to avoid kinking.
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to
waste outlet.
1
4
7
Fig. B.
Fig. A.
Congratulations on purchasing your American Standard
faucet with Speed Connect drain, a feature found only on
American Standard faucets.
*Your new American Standard faucet is designed to work only with the Speed Connect drain. Heplful tips for
removing your current drain can be found in the Troubleshooting section of these instructions.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Speed Connect™ Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS:
COLLAR ON
MOUNTING NUT
8
DOWN
WHITE FOAM
GASKET
NOT VISIBLE
DRAIN
FLANGE
Fig. A. Fig. B.
1
M 9 6 8 7 6 0 R e v . 1 . 3
M 9 6 8 7 6 0 R e v . 1 . 3
M 9 6 8 7 6 0 R e v . 1 . 3 M 9 6 8 7 6 0 R e v . 1 . 3
Certified to comply with ANSI A112.18.1
Installation
Instructions
Centerset Lavatory Faucet with
Speed Connect™ Drain
Adjustable Wrench Screwdriver Channel Locks
Recommended tools
CHECK OPERATION OF POP-UP
8
MAKE WATER SUPPLY AND WASTE CONNECTIONS
9
2
SERVICE
TEST INSTALLED FITTING
With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate HANDLE (1) to flush water lines thoroughly.
Replace AERATOR (3).
5
2
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (4) and fill lavatory with water.
Check that DRAIN STOPPER (5) makes a good seal
and retains water in SINK. If DRAIN STOPPER (5)
does not seal properly, please refer to Troubleshooting
section in these instructions.
Release POP-UP KNOB (4) down and check all drain
connections and "P" trap for leaks. Tighten
if necessary.
12
11
10
“P” TRAP
WASTE
OUTLET
Speed Connect™ Drain
Troubleshooting Guide
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled
as “Cam” and “Cam Cap” in the illustration. Fig. B.
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.
The Stopper can now be removed by lifting it out of the Drain. Fig. F.
CAM
CAM CAP
CABLE ADJUSTMENT PROCEDURE
If sink does not hold water even though Stopper is in the “down” position:
• Follow CABLE ADJUSTMENT PROCEDURE.
If Stopper does not raise up fully or sink drains too slowly:
• Follow CABLE ADJUSTMENT PROCEDURE.
If you need to remove the Stopper:
• Follow STOPPER REMOVAL PROCEDURE.
If you would like the ability to remove your Stopper simply by lifting it out of the drain:
Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.
Fig. B.
REMOVE
CAM
Fig. E.
Fig. F.
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as
“Cam” in the illustration. Fig. B.
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the
Stopper should be in the UP position. Fig. B, C.
Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the
Drain Body Connection (2) and hand-tighten. Fig. A.
STOPPER REMOVAL PROCEDURE
STOPPER INSTALLATION PROCEDURE
Locked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. G.
To install the stopper in “Locked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the rear of the
Sink and the American Standard logo is facing front. Rotate
Stopper slightly if necessary so that the Stopper slides all the
way down.Fig. G.
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
Troubling Shooting Guide to complete installation. Stopper will be
in “Locked” mode and not be removable.
Unlocked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. H.
To install the stopper in “Unlocked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the front of the
Sink and the American Standard logo is facing rear. Rotate Stopper
slightly if necessary so that the Stopper slides all the way down.
Fig. H.
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
“Troublingshooting Guide” to complete installation. Stopper will be
in “Unlocked” mode and removable.
Fig. J. Fig. K.
INSTALL
CAM CAP
CAM
INSTALL CAM
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be
removed) or “Unlock” Mode (Stopper is removable).
Unlocked Mode
LOOP TOWARD
FRONT OF SINK
180˚
LOGO
DRAIN
Fig. H.
Locked Mode
(Vandal Proof)
LOGO
DRAIN
Fig. G.
LOOP TOWARD
REAR OF SINK
2
1
RE-ATTACH
DISCONNECT
Fig. D.
REMOVE
CAM CAP
Thread CABLE CONNECTOR (1) clockwise
onto DRAIN BODY CONNECTION (2) and
hand tighten. Fig. A.
Your new POP-UP DRAIN installation is
now complete. Fig. B.
Note: Tailpeice on pop-up drain is 1-1/4” O.D.
Fig. B.
Fig. A.
ATTACH CABLE CONNECTOR
7
2
1
Fig. B.
1-1/4” O.D.
3
Fig. C.
STOPPER
1
DOWN
M961747-YYY0A
LIFT ROD
072574-0070A
EXTENSION ROD
066116-YYY0A
DRAIN STOPPER
M961711-0070A
TAILPIECE INSERT
070847-0070A
CLIP
066118-0070A
PIVOT ROD KIT
M953450-YYY0A
COMPLETE
DRAIN ASSEMBLY
070532-0040A
TAILPIECE
066117-YYY0A
2" FLANGE KIT
POP-UP DRAIN ASSEMBLY
BEFORE 01/07
1
3
4
5 6
2000.10X
2000.16X
Center -Set Lavatory Faucet
with Pop-up Drain
MODEL NUMBERS
2000.10X
2000.16X
T M
T M
© A m e r i c a n S t a n d a r d I n c . 2 0 0 2
Replace the "YYY" with
appropriate finish code
CHROME
WHITE
BONE
WHITE/CHROME
BLACK NICKEL
POLISHED BRASS
SATIN
SATIN/POL. BRASS
CHROME/POL. BRASS
002
020
021
025
062
099
295
297
299
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1-800 442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
Pr oduct n ames li sted he rein ar e tra de marks o f Ame ri can S ta ndard I nc.
IN MEXICO 01-800-839-12-00
2
1
5
2
4
1
Remove HANDLE (1), CAP (2), SCREWS (3) and
CARTRIDGE (4). Clean inlets and MANIFOLD (5).
Reassemble CARTRIDGE (4), alternately tightening
SCREWS (3). Replace CAP (2) and HANDLE (1).
Check flow.
If faucet drips, operate handle several times from
"off" to "on". Do not apply excessive force.
Clogged CARTRIDGE inlets may cause reduced flow
in "full on" hot or cold. To clean inlets, first turn off
water supply, then:
3
ADJUSTMENT WHEN
WATER IS TOO HOT
ADJUSTMENT WHEN
WATER IS TOO COLD
PRY RED RING FORWARD
AND ROTATE COUNTER-
CLOCKWISE ONE CLICK
PRY RED RING FORWARD
AND ROTATE CLOCKWISE
POINTER ON
HOT LIMIT STOP
"A"
"A"
"B"
"B"
RED RING HOT
LIMIT SAFETY
STOP
0
1
2
3
4
5
6
By restricting handle rotation and limiting the amount of hot
water allowed to mix with the cold, the HOT LIMIT SAFETY
STOP reduces risk of accidental scalding. To set the maximum
hot water temperature of your faucets, all you need
to do is adjust the setting on the HOT LIMIT SAFETY STOP.
Remove necessary trim parts. Use a flat blade screwdriver or
pull forward with your fingers to rotate red HOT LIMIT SAFETY
STOP. Follow Step "A" or "B" to adjust max./min. discharge
temperature. "0" being the hottest to "7" the coldest
temperature setting.
HOT LIMIT SAFETY STOP
IF FAUCET DRIPS
Fig. A.
M962430-0070A
CAM ASSEMBLY
M952430-0070A
CABLE ASSEMBLY
M952425-YYY0A
DRAIN ASSEMBLY
M962456-YYY0A
STOPPER
ASSEMBLY
M962457-YYY0A
FLANGE
ASSEMBLY
M962458-0070A
DRAIN MOUNTING KIT
A919661-0020A
TAILPIECE
M922872-0070A
CAM SEAT INSERT
M913207-0070A
TAILPIECE INSERT
M919660-0020A
6” TAILPIECE
(NOT INCLUDED
WITH FAUCET)
Thread FLANGE (1) counter-clockwise and remove
FLANGE (1) and FOAM GASKET (2) from drain
body. Fig. A.
Thread LOCKNUT (3) clock-wise to bottom of
drain body. Push GASKET (4) down against
LOCKNUT (3). Fig. B.
POP-UP DRAIN
Tighten TAILPIECE (4) on DRAIN BODY before
installing DRAIN BODY. Fig. B.
6
2
4
3
2
TIGHTEN LOCKNUT
1
REMOVE FLANGE
Remove CLEAR PLASTIC COVER (1).
Remove CARDBOARD SPACER (2) from under
DRAIN POP-UP (3).
2
2
3
3
1
2
4
3
1
9
1
Tighten LOCKNUT (1) firmly with Adjustable
Wrench or Channel Locks.
INSTALL DRAIN FROM
BELOW FIXTURE
5
From under side of SINK
install DRAIN BODY (1) up
through drain outlet.
Note: No plumber’s putty
or caulk is required.
The CABLE ATTACHMENT
POINT (2) must face towards
the rear of the SINK.
Install FOAM GASKET (3) and
FLANGE (4) onto drain body
from above SINK and tighten
FLANGE (4) firmly.
4
Fig. A. Fig. B.
Fig. A. Fig. B.
POP-UP KNOB (1) must be fully down. Fig. B.
FLANGE GASKET AND POP-UP KNOB
Check DRAIN FLANGE in SINK to ensure that
WHITE FOAM GASKET (3) is fully compressed
and not visible. Fig. A.
DRAIN
BODY
4
2
DRAIN
OUTLET
1
3
4
1
INSTALL FAUCET
Turn off hot and cold water
supplies before beginning.
CAUTION
GROOVE
(FAUCET
BASE)
6
4
7
5
Seat SEAL (1) into under side of FAUCET BASE (2).
Feed FAUCET SUPPLIES (3), MOUNTING STUD (4) and DRAIN
CABLE ASSEMBLY (8) through ESCUTCHEON (9) (optional) and the
mounting hole of lavatory or mounting surface. Fig. A.
From below, push GASKET (7) and RETAINING WASHER (5) onto
MOUNTING STUD (4). Secure Faucet with MOUNTING NUT (6),
pulling faucet to front of sink, so SUPPLIES (3) rests against
mounting hole. Before final tightening, make sure collar on
MOUNTING NUT (6) is seated into RETAINING WASHER (5).
Fig.B.
Adjust Faucet so that it is centered. Tighten MOUNTING NUT (6)
to complete faucet mounting.
REAR
OF SINK
Operate LIFT KNOB (1) to verify that STOPPER (2) opens and
closes.
Note: If STOPPER (2) does not open and close properly then
refer to the “troubleshooting section” of these instructions.
M 9 6 8 7 6 0 R e v . 1 . 3 M 9 6 8 7 6 0 R e v . 1 . 3 M 9 6 8 7 6 0 R e v . 1 . 3
M961741-YYY0A
HANDLE KIT
030126-0070A
HANDLE INDEX SET
A907086-YYY0A
CAP
918633-0070A
CARTRIDGE SCREWS
023529-0070A
CARTRIDGE KIT
M962492-0070A
MOUNTING KIT
911708-0070A
SEAL
M907671-YYY0A
ESCUTCHEON
M961745-0070A
MANIFOLD KIT
M962525-YYY0A
LIFT ROD
A922869-YYY0A
AERATOR
1
APPROX. 20"
2
COLD
HOT
3/8" COMPRESSION
RED
BAND
BLUE
BAND
Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies.
Connection on fitting supplies are 3/8" compression. Connect
left SUPPLY (1) to Hot (Marked with a Red Band) and right supply
to COLD (2) wall supply.
Faucet supplies are 20" long from faucet base.
Note: If additional supply length is required, installer must
purchase additional parts separately.
Important: If SUPPLY HOSES (1, 2) are to long, loop as
illustrated to avoid kinking.
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to
waste outlet.
1
4
7
Fig. B.
Fig. A.
Congratulations on purchasing your American Standard
faucet with Speed Connect drain, a feature found only on
American Standard faucets.
*Your new American Standard faucet is designed to work only with the Speed Connect drain. Heplful tips for
removing your current drain can be found in the Troubleshooting section of these instructions.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Speed Connect™ Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS:
COLLAR ON
MOUNTING NUT
8
DOWN
WHITE FOAM
GASKET
NOT VISIBLE
DRAIN
FLANGE
Fig. A. Fig. B.
1
M 9 6 8 7 6 0 R e v . 1 . 3
M 9 6 8 7 6 0 R e v . 1 . 3
M 9 6 8 7 6 0 R e v . 1 . 3 M 9 6 8 7 6 0 R e v . 1 . 3
Certified to comply with ANSI A112.18.1
Installation
Instructions
Centerset Lavatory Faucet with
Speed Connect™ Drain
Adjustable Wrench Screwdriver Channel Locks
Recommended tools
CHECK OPERATION OF POP-UP
8
MAKE WATER SUPPLY AND WASTE CONNECTIONS
9
2
SERVICE
TEST INSTALLED FITTING
With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate HANDLE (1) to flush water lines thoroughly.
Replace AERATOR (3).
5
2
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (4) and fill lavatory with water.
Check that DRAIN STOPPER (5) makes a good seal
and retains water in SINK. If DRAIN STOPPER (5)
does not seal properly, please refer to Troubleshooting
section in these instructions.
Release POP-UP KNOB (4) down and check all drain
connections and "P" trap for leaks. Tighten
if necessary.
12
11
10
“P” TRAP
WASTE
OUTLET
Speed Connect™ Drain
Troubleshooting Guide
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled
as “Cam” and “Cam Cap” in the illustration. Fig. B.
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.
The Stopper can now be removed by lifting it out of the Drain. Fig. F.
CAM
CAM CAP
CABLE ADJUSTMENT PROCEDURE
If sink does not hold water even though Stopper is in the “down” position:
• Follow CABLE ADJUSTMENT PROCEDURE.
If Stopper does not raise up fully or sink drains too slowly:
• Follow CABLE ADJUSTMENT PROCEDURE.
If you need to remove the Stopper:
• Follow STOPPER REMOVAL PROCEDURE.
If you would like the ability to remove your Stopper simply by lifting it out of the drain:
Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.
Fig. B.
REMOVE
CAM
Fig. E.
Fig. F.
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as
“Cam” in the illustration. Fig. B.
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the
Stopper should be in the UP position. Fig. B, C.
Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the
Drain Body Connection (2) and hand-tighten. Fig. A.
STOPPER REMOVAL PROCEDURE
STOPPER INSTALLATION PROCEDURE
Locked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. G.
To install the stopper in “Locked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the rear of the
Sink and the American Standard logo is facing front. Rotate
Stopper slightly if necessary so that the Stopper slides all the
way down.Fig. G.
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
Troubling Shooting Guide to complete installation. Stopper will be
in “Locked” mode and not be removable.
Unlocked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. H.
To install the stopper in “Unlocked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the front of the
Sink and the American Standard logo is facing rear. Rotate Stopper
slightly if necessary so that the Stopper slides all the way down.
Fig. H.
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
“Troublingshooting Guide” to complete installation. Stopper will be
in “Unlocked” mode and removable.
Fig. J. Fig. K.
INSTALL
CAM CAP
CAM
INSTALL CAM
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be
removed) or “Unlock” Mode (Stopper is removable).
Unlocked Mode
LOOP TOWARD
FRONT OF SINK
180˚
LOGO
DRAIN
Fig. H.
Locked Mode
(Vandal Proof)
LOGO
DRAIN
Fig. G.
LOOP TOWARD
REAR OF SINK
2
1
RE-ATTACH
DISCONNECT
Fig. D.
REMOVE
CAM CAP
Thread CABLE CONNECTOR (1) clockwise
onto DRAIN BODY CONNECTION (2) and
hand tighten. Fig. A.
Your new POP-UP DRAIN installation is
now complete. Fig. B.
Note: Tailpeice on pop-up drain is 1-1/4” O.D.
Fig. B.
Fig. A.
ATTACH CABLE CONNECTOR
7
2
1
Fig. B.
1-1/4” O.D.
3
Fig. C.
STOPPER
1
DOWN
M961747-YYY0A
LIFT ROD
072574-0070A
EXTENSION ROD
066116-YYY0A
DRAIN STOPPER
M961711-0070A
TAILPIECE INSERT
070847-0070A
CLIP
066118-0070A
PIVOT ROD KIT
M953450-YYY0A
COMPLETE
DRAIN ASSEMBLY
070532-0040A
TAILPIECE
066117-YYY0A
2" FLANGE KIT
POP-UP DRAIN ASSEMBLY
BEFORE 01/07
1
3
4
5 6
2000.10X
2000.16X
Center -Set Lavatory Faucet
with Pop-up Drain
MODEL NUMBERS
2000.10X
2000.16X
T M
T M
© A m e r i c a n S t a n d a r d I n c . 2 0 0 2
Replace the "YYY" with
appropriate finish code
CHROME
WHITE
BONE
WHITE/CHROME
BLACK NICKEL
POLISHED BRASS
SATIN
SATIN/POL. BRASS
CHROME/POL. BRASS
002
020
021
025
062
099
295
297
299
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1-800 442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
Pr oduct n ames li sted he rein ar e tra de marks o f Ame ri can S ta ndard I nc.
IN MEXICO 01-800-839-12-00
2
1
5
2
4
1
Remove HANDLE (1), CAP (2), SCREWS (3) and
CARTRIDGE (4). Clean inlets and MANIFOLD (5).
Reassemble CARTRIDGE (4), alternately tightening
SCREWS (3). Replace CAP (2) and HANDLE (1).
Check flow.
If faucet drips, operate handle several times from
"off" to "on". Do not apply excessive force.
Clogged CARTRIDGE inlets may cause reduced flow
in "full on" hot or cold. To clean inlets, first turn off
water supply, then:
3
ADJUSTMENT WHEN
WATER IS TOO HOT
ADJUSTMENT WHEN
WATER IS TOO COLD
PRY RED RING FORWARD
AND ROTATE COUNTER-
CLOCKWISE ONE CLICK
PRY RED RING FORWARD
AND ROTATE CLOCKWISE
POINTER ON
HOT LIMIT STOP
"A"
"A"
"B"
"B"
RED RING HOT
LIMIT SAFETY
STOP
0
1
2
3
4
5
6
By restricting handle rotation and limiting the amount of hot
water allowed to mix with the cold, the HOT LIMIT SAFETY
STOP reduces risk of accidental scalding. To set the maximum
hot water temperature of your faucets, all you need
to do is adjust the setting on the HOT LIMIT SAFETY STOP.
Remove necessary trim parts. Use a flat blade screwdriver or
pull forward with your fingers to rotate red HOT LIMIT SAFETY
STOP. Follow Step "A" or "B" to adjust max./min. discharge
temperature. "0" being the hottest to "7" the coldest
temperature setting.
HOT LIMIT SAFETY STOP
IF FAUCET DRIPS
Fig. A.
M962430-0070A
CAM ASSEMBLY
M952430-0070A
CABLE ASSEMBLY
M952425-YYY0A
DRAIN ASSEMBLY
M962456-YYY0A
STOPPER
ASSEMBLY
M962457-YYY0A
FLANGE
ASSEMBLY
M962458-0070A
DRAIN MOUNTING KIT
A919661-0020A
TAILPIECE
M922872-0070A
CAM SEAT INSERT
M913207-0070A
TAILPIECE INSERT
M919660-0020A
6” TAILPIECE
(NOT INCLUDED
WITH FAUCET)
Thread FLANGE (1) counter-clockwise and remove
FLANGE (1) and FOAM GASKET (2) from drain
body. Fig. A.
Thread LOCKNUT (3) clock-wise to bottom of
drain body. Push GASKET (4) down against
LOCKNUT (3). Fig. B.
POP-UP DRAIN
Tighten TAILPIECE (4) on DRAIN BODY before
installing DRAIN BODY. Fig. B.
6
2
4
3
2
TIGHTEN LOCKNUT
1
REMOVE FLANGE
Remove CLEAR PLASTIC COVER (1).
Remove CARDBOARD SPACER (2) from under
DRAIN POP-UP (3).
2
2
3
3
1
2
4
3
1
9
1
Tighten LOCKNUT (1) firmly with Adjustable
Wrench or Channel Locks.
INSTALL DRAIN FROM
BELOW FIXTURE
5
From under side of SINK
install DRAIN BODY (1) up
through drain outlet.
Note: No plumber’s putty
or caulk is required.
The CABLE ATTACHMENT
POINT (2) must face towards
the rear of the SINK.
Install FOAM GASKET (3) and
FLANGE (4) onto drain body
from above SINK and tighten
FLANGE (4) firmly.
4
Fig. A. Fig. B.
Fig. A. Fig. B.
POP-UP KNOB (1) must be fully down. Fig. B.
FLANGE GASKET AND POP-UP KNOB
Check DRAIN FLANGE in SINK to ensure that
WHITE FOAM GASKET (3) is fully compressed
and not visible. Fig. A.
DRAIN
BODY
4
2
DRAIN
OUTLET
1
3
4
1
INSTALL FAUCET
Turn off hot and cold water
supplies before beginning.
CAUTION
GROOVE
(FAUCET
BASE)
6
4
7
5
Seat SEAL (1) into under side of FAUCET BASE (2).
Feed FAUCET SUPPLIES (3), MOUNTING STUD (4) and DRAIN
CABLE ASSEMBLY (8) through ESCUTCHEON (9) (optional) and the
mounting hole of lavatory or mounting surface. Fig. A.
From below, push GASKET (7) and RETAINING WASHER (5) onto
MOUNTING STUD (4). Secure Faucet with MOUNTING NUT (6),
pulling faucet to front of sink, so SUPPLIES (3) rests against
mounting hole. Before final tightening, make sure collar on
MOUNTING NUT (6) is seated into RETAINING WASHER (5).
Fig.B.
Adjust Faucet so that it is centered. Tighten MOUNTING NUT (6)
to complete faucet mounting.
REAR
OF SINK
Operate LIFT KNOB (1) to verify that STOPPER (2) opens and
closes.
Note: If STOPPER (2) does not open and close properly then
refer to the “troubleshooting section” of these instructions.
M 9 6 8 7 6 0 R e v . 1 . 3 M 9 6 8 7 6 0 R e v . 1 . 3 M 9 6 8 7 6 0 R e v . 1 . 3
M961741-YYY0A
HANDLE KIT
030126-0070A
HANDLE INDEX SET
A907086-YYY0A
CAP
918633-0070A
CARTRIDGE SCREWS
023529-0070A
CARTRIDGE KIT
M962492-0070A
MOUNTING KIT
911708-0070A
SEAL
M907671-YYY0A
ESCUTCHEON
M961745-0070A
MANIFOLD KIT
M962525-YYY0A
LIFT ROD
A922869-YYY0A
AERATOR
1
APPROX. 20"
2
COLD
HOT
3/8" COMPRESSION
RED
BAND
BLUE
BAND
Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies.
Connection on fitting supplies are 3/8" compression. Connect
left SUPPLY (1) to Hot (Marked with a Red Band) and right supply
to COLD (2) wall supply.
Faucet supplies are 20" long from faucet base.
Note: If additional supply length is required, installer must
purchase additional parts separately.
Important: If SUPPLY HOSES (1, 2) are to long, loop as
illustrated to avoid kinking.
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to
waste outlet.
1
4
7
Fig. B.
Fig. A.
Congratulations on purchasing your American Standard
faucet with Speed Connect drain, a feature found only on
American Standard faucets.
*Your new American Standard faucet is designed to work only with the Speed Connect drain. Heplful tips for
removing your current drain can be found in the Troubleshooting section of these instructions.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Speed Connect™ Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS:
COLLAR ON
MOUNTING NUT
8
DOWN
WHITE FOAM
GASKET
NOT VISIBLE
DRAIN
FLANGE
Fig. A. Fig. B.
1
M 9 6 8 7 6 0 R e v . 1 . 3
M 9 6 8 7 6 0 R e v . 1 . 3
M 9 6 8 7 6 0 R e v . 1 . 3 M 9 6 8 7 6 0 R e v . 1 . 3
Certified to comply with ANSI A112.18.1
Installation
Instructions
Centerset Lavatory Faucet with
Speed Connect™ Drain
Adjustable Wrench Screwdriver Channel Locks
Recommended tools
CHECK OPERATION OF POP-UP
8
MAKE WATER SUPPLY AND WASTE CONNECTIONS
9
2
SERVICE
TEST INSTALLED FITTING
With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate HANDLE (1) to flush water lines thoroughly.
Replace AERATOR (3).
5
2
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (4) and fill lavatory with water.
Check that DRAIN STOPPER (5) makes a good seal
and retains water in SINK. If DRAIN STOPPER (5)
does not seal properly, please refer to Troubleshooting
section in these instructions.
Release POP-UP KNOB (4) down and check all drain
connections and "P" trap for leaks. Tighten
if necessary.
12
11
10
“P” TRAP
WASTE
OUTLET
Speed Connect™ Drain
Troubleshooting Guide
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled
as “Cam” and “Cam Cap” in the illustration. Fig. B.
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.
The Stopper can now be removed by lifting it out of the Drain. Fig. F.
CAM
CAM CAP
CABLE ADJUSTMENT PROCEDURE
If sink does not hold water even though Stopper is in the “down” position:
• Follow CABLE ADJUSTMENT PROCEDURE.
If Stopper does not raise up fully or sink drains too slowly:
• Follow CABLE ADJUSTMENT PROCEDURE.
If you need to remove the Stopper:
• Follow STOPPER REMOVAL PROCEDURE.
If you would like the ability to remove your Stopper simply by lifting it out of the drain:
Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.
Fig. B.
REMOVE
CAM
Fig. E.
Fig. F.
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as
“Cam” in the illustration. Fig. B.
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the
Stopper should be in the UP position. Fig. B, C.
Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the
Drain Body Connection (2) and hand-tighten. Fig. A.
STOPPER REMOVAL PROCEDURE
STOPPER INSTALLATION PROCEDURE
Locked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. G.
To install the stopper in “Locked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the rear of the
Sink and the American Standard logo is facing front. Rotate
Stopper slightly if necessary so that the Stopper slides all the
way down.Fig. G.
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
Troubling Shooting Guide to complete installation. Stopper will be
in “Locked” mode and not be removable.
Unlocked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. H.
To install the stopper in “Unlocked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the front of the
Sink and the American Standard logo is facing rear. Rotate Stopper
slightly if necessary so that the Stopper slides all the way down.
Fig. H.
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
“Troublingshooting Guide” to complete installation. Stopper will be
in “Unlocked” mode and removable.
Fig. J. Fig. K.
INSTALL
CAM CAP
CAM
INSTALL CAM
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be
removed) or “Unlock” Mode (Stopper is removable).
Unlocked Mode
LOOP TOWARD
FRONT OF SINK
180˚
LOGO
DRAIN
Fig. H.
Locked Mode
(Vandal Proof)
LOGO
DRAIN
Fig. G.
LOOP TOWARD
REAR OF SINK
2
1
RE-ATTACH
DISCONNECT
Fig. D.
REMOVE
CAM CAP
Thread CABLE CONNECTOR (1) clockwise
onto DRAIN BODY CONNECTION (2) and
hand tighten. Fig. A.
Your new POP-UP DRAIN installation is
now complete. Fig. B.
Note: Tailpeice on pop-up drain is 1-1/4” O.D.
Fig. B.
Fig. A.
ATTACH CABLE CONNECTOR
7
2
1
Fig. B.
1-1/4” O.D.
3
Fig. C.
STOPPER
1
DOWN
M961747-YYY0A
LIFT ROD
072574-0070A
EXTENSION ROD
066116-YYY0A
DRAIN STOPPER
M961711-0070A
TAILPIECE INSERT
070847-0070A
CLIP
066118-0070A
PIVOT ROD KIT
M953450-YYY0A
COMPLETE
DRAIN ASSEMBLY
070532-0040A
TAILPIECE
066117-YYY0A
2" FLANGE KIT
POP-UP DRAIN ASSEMBLY
BEFORE 01/07
1
3
4
5 6
2000.10X
2000.16X
Center -Set Lavatory Faucet
with Pop-up Drain
MODEL NUMBERS
2000.10X
2000.16X
T M
T M
© A m e r i c a n S t a n d a r d I n c . 2 0 0 2
Replace the "YYY" with
appropriate finish code
CHROME
WHITE
BONE
WHITE/CHROME
BLACK NICKEL
POLISHED BRASS
SATIN
SATIN/POL. BRASS
CHROME/POL. BRASS
002
020
021
025
062
099
295
297
299
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1-800 442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
Pr oduct n ames li sted he rein ar e tra de marks o f Ame ri can S ta ndard I nc.
IN MEXICO 01-800-839-12-00
2
1
5
2
4
1
Remove HANDLE (1), CAP (2), SCREWS (3) and
CARTRIDGE (4). Clean inlets and MANIFOLD (5).
Reassemble CARTRIDGE (4), alternately tightening
SCREWS (3). Replace CAP (2) and HANDLE (1).
Check flow.
If faucet drips, operate handle several times from
"off" to "on". Do not apply excessive force.
Clogged CARTRIDGE inlets may cause reduced flow
in "full on" hot or cold. To clean inlets, first turn off
water supply, then:
3
ADJUSTMENT WHEN
WATER IS TOO HOT
ADJUSTMENT WHEN
WATER IS TOO COLD
PRY RED RING FORWARD
AND ROTATE COUNTER-
CLOCKWISE ONE CLICK
PRY RED RING FORWARD
AND ROTATE CLOCKWISE
POINTER ON
HOT LIMIT STOP
"A"
"A"
"B"
"B"
RED RING HOT
LIMIT SAFETY
STOP
0
1
2
3
4
5
6
By restricting handle rotation and limiting the amount of hot
water allowed to mix with the cold, the HOT LIMIT SAFETY
STOP reduces risk of accidental scalding. To set the maximum
hot water temperature of your faucets, all you need
to do is adjust the setting on the HOT LIMIT SAFETY STOP.
Remove necessary trim parts. Use a flat blade screwdriver or
pull forward with your fingers to rotate red HOT LIMIT SAFETY
STOP. Follow Step "A" or "B" to adjust max./min. discharge
temperature. "0" being the hottest to "7" the coldest
temperature setting.
HOT LIMIT SAFETY STOP
IF FAUCET DRIPS
Fig. A.
M962430-0070A
CAM ASSEMBLY
M952430-0070A
CABLE ASSEMBLY
M952425-YYY0A
DRAIN ASSEMBLY
M962456-YYY0A
STOPPER
ASSEMBLY
M962457-YYY0A
FLANGE
ASSEMBLY
M962458-0070A
DRAIN MOUNTING KIT
A919661-0020A
TAILPIECE
M922872-0070A
CAM SEAT INSERT
M913207-0070A
TAILPIECE INSERT
M919660-0020A
6” TAILPIECE
(NOT INCLUDED
WITH FAUCET)
Thread FLANGE (1) counter-clockwise and remove
FLANGE (1) and FOAM GASKET (2) from drain
body. Fig. A.
Thread LOCKNUT (3) clock-wise to bottom of
drain body. Push GASKET (4) down against
LOCKNUT (3). Fig. B.
POP-UP DRAIN
Tighten TAILPIECE (4) on DRAIN BODY before
installing DRAIN BODY. Fig. B.
6
2
4
3
2
TIGHTEN LOCKNUT
REMOVE FLANGE
Remove CLEAR PLASTIC COVER (1).
Remove CARDBOARD SPACER (2) from under
DRAIN POP-UP (3).
2
2
3
3
1
2
4
3
1
9
1
Tighten LOCKNUT (1) firmly with Adjustable
Wrench or Channel Locks.
INSTALL DRAIN FROM
BELOW FIXTURE
5
From under side of SINK
install DRAIN BODY (1) up
through drain outlet.
Note: No plumber’s putty
or caulk is required.
The CABLE ATTACHMENT
POINT (2) must face towards
the rear of the SINK.
Install FOAM GASKET (3) and
FLANGE (4) onto drain body
from above SINK and tighten
FLANGE (4) firmly.
4
Fig. A. Fig. B.
Fig. A. Fig. B.
POP-UP KNOB (1) must be fully down. Fig. B.
FLANGE GASKET AND POP-UP KNOB
Check DRAIN FLANGE in SINK to ensure that
WHITE FOAM GASKET (3) is fully compressed
and not visible. Fig. A.
DRAIN
BODY
4
2
DRAIN
OUTLET
1
3
4
1
INSTALL FAUCET
Turn off hot and cold water
supplies before beginning.
CAUTION
GROOVE
(FAUCET
BASE)
6
4
7
5
Seat SEAL (1) into under side of FAUCET BASE (2).
Feed FAUCET SUPPLIES (3), MOUNTING STUD (4) and DRAIN
CABLE ASSEMBLY (8) through ESCUTCHEON (9) (optional) and the
mounting hole of lavatory or mounting surface. Fig. A.
From below, push GASKET (7) and RETAINING WASHER (5) onto
MOUNTING STUD (4). Secure Faucet with MOUNTING NUT (6),
pulling faucet to front of sink, so SUPPLIES (3) rests against
mounting hole. Before final tightening, make sure collar on
MOUNTING NUT (6) is seated into RETAINING WASHER (5).
Fig.B.
Adjust Faucet so that it is centered. Tighten MOUNTING NUT (6)
to complete faucet mounting.
REAR
OF SINK
Operate LIFT KNOB (1) to verify that STOPPER (2) opens and
closes.
Note: If STOPPER (2) does not open and close properly then
refer to the “troubleshooting section” of these instructions.
M 9 6 8 7 6 0 R e v . 1 . 3 M 9 6 8 7 6 0 R e v . 1 . 3 M 9 6 8 7 6 0 R e v . 1 . 3
M961741-YYY0A
HANDLE KIT
030126-0070A
HANDLE INDEX SET
A907086-YYY0A
CAP
918633-0070A
CARTRIDGE SCREWS
023529-0070A
CARTRIDGE KIT
M962492-0070A
MOUNTING KIT
911708-0070A
SEAL
M907671-YYY0A
ESCUTCHEON
M961745-0070A
MANIFOLD KIT
M962525-YYY0A
LIFT ROD
A922869-YYY0A
AERATOR
1
APPROX. 20"
2
COLD
HOT
3/8" COMPRESSION
RED
BAND
BLUE
BAND
Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies.
Connection on fitting supplies are 3/8" compression. Connect
left SUPPLY (1) to Hot (Marked with a Red Band) and right supply
to COLD (2) wall supply.
Faucet supplies are 20" long from faucet base.
Note: If additional supply length is required, installer must
purchase additional parts separately.
Important: If SUPPLY HOSES (1, 2) are to long, loop as
illustrated to avoid kinking.
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to
waste outlet.
1
4
7
Fig. B.
Fig. A.
Congratulations on purchasing your American Standard
faucet with Speed Connect drain, a feature found only on
American Standard faucets.
*Your new American Standard faucet is designed to work only with the Speed Connect drain. Heplful tips for
removing your current drain can be found in the Troubleshooting section of these instructions.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Speed Connect™ Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS:
COLLAR ON
MOUNTING NUT
8
DOWN
WHITE FOAM
GASKET
NOT VISIBLE
DRAIN
FLANGE
Fig. A. Fig. B.
1
M 9 6 8 7 6 0 R e v . 1 . 3
M 9 6 8 7 6 0 R e v . 1 . 3
M 9 6 8 7 6 0 R e v . 1 . 3 M 9 6 8 7 6 0 R e v . 1 . 3
Certified to comply with ANSI A112.18.1
Installation
Instructions
Centerset Lavatory Faucet with
Speed Connect™ Drain
Adjustable Wrench Screwdriver Channel Locks
Recommended tools
CHECK OPERATION OF POP-UP
8
MAKE WATER SUPPLY AND WASTE CONNECTIONS
9
2
SERVICE
TEST INSTALLED FITTING
With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate HANDLE (1) to flush water lines thoroughly.
Replace AERATOR (3).
5
2
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (4) and fill lavatory with water.
Check that DRAIN STOPPER (5) makes a good seal
and retains water in SINK. If DRAIN STOPPER (5)
does not seal properly, please refer to Troubleshooting
section in these instructions.
Release POP-UP KNOB (4) down and check all drain
connections and "P" trap for leaks. Tighten
if necessary.
12
11
10
“P” TRAP
WASTE
OUTLET
Speed Connect™ Drain
Troubleshooting Guide
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled
as “Cam” and “Cam Cap” in the illustration. Fig. B.
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.
The Stopper can now be removed by lifting it out of the Drain. Fig. F.
CAM
CAM CAP
CABLE ADJUSTMENT PROCEDURE
If sink does not hold water even though Stopper is in the “down” position:
• Follow CABLE ADJUSTMENT PROCEDURE.
If Stopper does not raise up fully or sink drains too slowly:
• Follow CABLE ADJUSTMENT PROCEDURE.
If you need to remove the Stopper:
• Follow STOPPER REMOVAL PROCEDURE.
If you would like the ability to remove your Stopper simply by lifting it out of the drain:
Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.
Fig. B.
REMOVE
CAM
Fig. E.
Fig. F.
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as
“Cam” in the illustration. Fig. B.
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the
Stopper should be in the UP position. Fig. B, C.
Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the
Drain Body Connection (2) and hand-tighten. Fig. A.
STOPPER REMOVAL PROCEDURE
STOPPER INSTALLATION PROCEDURE
Locked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. G.
To install the stopper in “Locked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the rear of the
Sink and the American Standard logo is facing front. Rotate
Stopper slightly if necessary so that the Stopper slides all the
way down.Fig. G.
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
Troubling Shooting Guide to complete installation. Stopper will be
in “Locked” mode and not be removable.
Unlocked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. H.
To install the stopper in “Unlocked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the front of the
Sink and the American Standard logo is facing rear. Rotate Stopper
slightly if necessary so that the Stopper slides all the way down.
Fig. H.
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
“Troublingshooting Guide” to complete installation. Stopper will be
in “Unlocked” mode and removable.
Fig. J. Fig. K.
INSTALL
CAM CAP
CAM
INSTALL CAM
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be
removed) or “Unlock” Mode (Stopper is removable).
Unlocked Mode
LOOP TOWARD
FRONT OF SINK
180˚
LOGO
DRAIN
Fig. H.
Locked Mode
(Vandal Proof)
LOGO
DRAIN
Fig. G.
LOOP TOWARD
REAR OF SINK
2
1
RE-ATTACH
DISCONNECT
Fig. D.
REMOVE
CAM CAP
Thread CABLE CONNECTOR (1) clockwise
onto DRAIN BODY CONNECTION (2) and
hand tighten. Fig. A.
Your new POP-UP DRAIN installation is
now complete. Fig. B.
Note: Tailpeice on pop-up drain is 1-1/4” O.D.
Fig. B.
Fig. A.
ATTACH CABLE CONNECTOR
7
2
1
Fig. B.
1-1/4” O.D.
3
Fig. C.
STOPPER
1
DOWN
M961747-YYY0A
LIFT ROD
072574-0070A
EXTENSION ROD
066116-YYY0A
DRAIN STOPPER
M961711-0070A
TAILPIECE INSERT
070847-0070A
CLIP
066118-0070A
PIVOT ROD KIT
M953450-YYY0A
COMPLETE
DRAIN ASSEMBLY
070532-0040A
TAILPIECE
066117-YYY0A
2" FLANGE KIT
POP-UP DRAIN ASSEMBLY
BEFORE 01/07
1
3
4
5 6
2000.10X
2000.16X
Center -Set Lavatory Faucet
with Pop-up Drain
MODEL NUMBERS
2000.10X
2000.16X
T M
T M
© A m e r i c a n S t a n d a r d I n c . 2 0 0 2
Replace the "YYY" with
appropriate finish code
CHROME
WHITE
BONE
WHITE/CHROME
BLACK NICKEL
POLISHED BRASS
SATIN
SATIN/POL. BRASS
CHROME/POL. BRASS
002
020
021
025
062
099
295
297
299
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1-800 442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
Pr oduct n ames li sted he rein ar e tra de marks o f Ame ri can S ta ndard I nc.
IN MEXICO 01-800-839-12-00
2
1
5
2
4
1
Remove HANDLE (1), CAP (2), SCREWS (3) and
CARTRIDGE (4). Clean inlets and MANIFOLD (5).
Reassemble CARTRIDGE (4), alternately tightening
SCREWS (3). Replace CAP (2) and HANDLE (1).
Check flow.
If faucet drips, operate handle several times from
"off" to "on". Do not apply excessive force.
Clogged CARTRIDGE inlets may cause reduced flow
in "full on" hot or cold. To clean inlets, first turn off
water supply, then:
3
ADJUSTMENT WHEN
WATER IS TOO HOT
ADJUSTMENT WHEN
WATER IS TOO COLD
PRY RED RING FORWARD
AND ROTATE COUNTER-
CLOCKWISE ONE CLICK
PRY RED RING FORWARD
AND ROTATE CLOCKWISE
POINTER ON
HOT LIMIT STOP
"A"
"A"
"B"
"B"
RED RING HOT
LIMIT SAFETY
STOP
0
1
2
3
4
5
6
By restricting handle rotation and limiting the amount of hot
water allowed to mix with the cold, the HOT LIMIT SAFETY
STOP reduces risk of accidental scalding. To set the maximum
hot water temperature of your faucets, all you need
to do is adjust the setting on the HOT LIMIT SAFETY STOP.
Remove necessary trim parts. Use a flat blade screwdriver or
pull forward with your fingers to rotate red HOT LIMIT SAFETY
STOP. Follow Step "A" or "B" to adjust max./min. discharge
temperature. "0" being the hottest to "7" the coldest
temperature setting.
HOT LIMIT SAFETY STOP
IF FAUCET DRIPS
Fig. A.
M962430-0070A
CAM ASSEMBLY
M952430-0070A
CABLE ASSEMBLY
M952425-YYY0A
DRAIN ASSEMBLY
M962456-YYY0A
STOPPER
ASSEMBLY
M962457-YYY0A
FLANGE
ASSEMBLY
M962458-0070A
DRAIN MOUNTING KIT
A919661-0020A
TAILPIECE
M922872-0070A
CAM SEAT INSERT
M913207-0070A
TAILPIECE INSERT
M919660-0020A
6” TAILPIECE
(NOT INCLUDED
WITH FAUCET)
Thread FLANGE (1) counter-clockwise and remove
FLANGE (1) and FOAM GASKET (2) from drain
body. Fig. A.
Thread LOCKNUT (3) clock-wise to bottom of
drain body. Push GASKET (4) down against
LOCKNUT (3). Fig. B.
POP-UP DRAIN
Tighten TAILPIECE (4) on DRAIN BODY before
installing DRAIN BODY. Fig. B.
6
2
4
3
2
TIGHTEN LOCKNUT
1
REMOVE FLANGE
Remove CLEAR PLASTIC COVER (1).
Remove CARDBOARD SPACER (2) from under
DRAIN POP-UP (3).
2
2
3
3
1
2
4
3
1
9
1
Tighten LOCKNUT (1) firmly with Adjustable
Wrench or Channel Locks.
INSTALL DRAIN FROM
BELOW FIXTURE
5
From under side of SINK
install DRAIN BODY (1) up
through drain outlet.
Note: No plumber’s putty
or caulk is required.
The CABLE ATTACHMENT
POINT (2) must face towards
the rear of the SINK.
Install FOAM GASKET (3) and
FLANGE (4) onto drain body
from above SINK and tighten
FLANGE (4) firmly.
4
Fig. A. Fig. B.
Fig. A. Fig. B.
POP-UP KNOB (1) must be fully down. Fig. B.
FLANGE GASKET AND POP-UP KNOB
Check DRAIN FLANGE in SINK to ensure that
WHITE FOAM GASKET (3) is fully compressed
and not visible. Fig. A.
DRAIN
BODY
4
2
DRAIN
OUTLET
1
3
4
1
INSTALL FAUCET
Turn off hot and cold water
supplies before beginning.
CAUTION
GROOVE
(FAUCET
BASE)
6
4
7
5
Seat SEAL (1) into under side of FAUCET BASE (2).
Feed FAUCET SUPPLIES (3), MOUNTING STUD (4) and DRAIN
CABLE ASSEMBLY (8) through ESCUTCHEON (9) (optional) and the
mounting hole of lavatory or mounting surface. Fig. A.
From below, push GASKET (7) and RETAINING WASHER (5) onto
MOUNTING STUD (4). Secure Faucet with MOUNTING NUT (6),
pulling faucet to front of sink, so SUPPLIES (3) rests against
mounting hole. Before final tightening, make sure collar on
MOUNTING NUT (6) is seated into RETAINING WASHER (5).
Fig.B.
Adjust Faucet so that it is centered. Tighten MOUNTING NUT (6)
to complete faucet mounting.
REAR
OF SINK
Operate LIFT KNOB (1) to verify that STOPPER (2) opens and
closes.
Note: If STOPPER (2) does not open and close properly then
refer to the “troubleshooting section” of these instructions.
M 9 6 8 7 6 0 R e v . 1 . 3 M 9 6 8 7 6 0 R e v . 1 . 3 M 9 6 8 7 6 0 R e v . 1 . 3
M961741-YYY0A
HANDLE KIT
030126-0070A
HANDLE INDEX SET
A907086-YYY0A
CAP
918633-0070A
CARTRIDGE SCREWS
023529-0070A
CARTRIDGE KIT
M962492-0070A
MOUNTING KIT
911708-0070A
SEAL
M907671-YYY0A
ESCUTCHEON
M961745-0070A
MANIFOLD KIT
M962525-YYY0A
LIFT ROD
A922869-YYY0A
AERATOR
1
APPROX. 20"
2
COLD
HOT
3/8" COMPRESSION
RED
BAND
BLUE
BAND
Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies.
Connection on fitting supplies are 3/8" compression. Connect
left SUPPLY (1) to Hot (Marked with a Red Band) and right supply
to COLD (2) wall supply.
Faucet supplies are 20" long from faucet base.
Note: If additional supply length is required, installer must
purchase additional parts separately.
Important: If SUPPLY HOSES (1, 2) are to long, loop as
illustrated to avoid kinking.
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to
waste outlet.
1
4
7
Fig. B.
Fig. A.
Congratulations on purchasing your American Standard
faucet with Speed Connect drain, a feature found only on
American Standard faucets.
*Your new American Standard faucet is designed to work only with the Speed Connect drain. Heplful tips for
removing your current drain can be found in the Troubleshooting section of these instructions.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Speed Connect™ Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS:
COLLAR ON
MOUNTING NUT
8
DOWN
WHITE FOAM
GASKET
NOT VISIBLE
DRAIN
FLANGE
Fig. A. Fig. B.
1
M 9 6 8 7 6 0 R e v . 1 . 3
M 9 6 8 7 6 0 R e v . 1 . 3
M 9 6 8 7 6 0 R e v . 1 . 3 M 9 6 8 7 6 0 R e v . 1 . 3
Certified to comply with ANSI A112.18.1
Installation
Instructions
Centerset Lavatory Faucet with
Speed Connect™ Drain
Adjustable Wrench Screwdriver Channel Locks
Recommended tools
CHECK OPERATION OF POP-UP
8
MAKE WATER SUPPLY AND WASTE CONNECTIONS
9
2
SERVICE
TEST INSTALLED FITTING
With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate HANDLE (1) to flush water lines thoroughly.
Replace AERATOR (3).
5
2
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (4) and fill lavatory with water.
Check that DRAIN STOPPER (5) makes a good seal
and retains water in SINK. If DRAIN STOPPER (5)
does not seal properly, please refer to Troubleshooting
section in these instructions.
Release POP-UP KNOB (4) down and check all drain
connections and "P" trap for leaks. Tighten
if necessary.
12
11
10
“P” TRAP
WASTE
OUTLET
Speed Connect™ Drain
Troubleshooting Guide
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled
as “Cam” and “Cam Cap” in the illustration. Fig. B.
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.
The Stopper can now be removed by lifting it out of the Drain. Fig. F.
CAM
CAM CAP
CABLE ADJUSTMENT PROCEDURE
If sink does not hold water even though Stopper is in the “down” position:
• Follow CABLE ADJUSTMENT PROCEDURE.
If Stopper does not raise up fully or sink drains too slowly:
• Follow CABLE ADJUSTMENT PROCEDURE.
If you need to remove the Stopper:
• Follow STOPPER REMOVAL PROCEDURE.
If you would like the ability to remove your Stopper simply by lifting it out of the drain:
Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.
Fig. B.
REMOVE
CAM
Fig. E.
Fig. F.
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as
“Cam” in the illustration. Fig. B.
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the
Stopper should be in the UP position. Fig. B, C.
Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the
Drain Body Connection (2) and hand-tighten. Fig. A.
STOPPER REMOVAL PROCEDURE
STOPPER INSTALLATION PROCEDURE
Locked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. G.
To install the stopper in “Locked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the rear of the
Sink and the American Standard logo is facing front. Rotate
Stopper slightly if necessary so that the Stopper slides all the
way down.Fig. G.
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
Troubling Shooting Guide to complete installation. Stopper will be
in “Locked” mode and not be removable.
Unlocked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. H.
To install the stopper in “Unlocked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the front of the
Sink and the American Standard logo is facing rear. Rotate Stopper
slightly if necessary so that the Stopper slides all the way down.
Fig. H.
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
“Troublingshooting Guide” to complete installation. Stopper will be
in “Unlocked” mode and removable.
Fig. J. Fig. K.
INSTALL
CAM CAP
CAM
INSTALL CAM
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be
removed) or “Unlock” Mode (Stopper is removable).
Unlocked Mode
LOOP TOWARD
FRONT OF SINK
180˚
LOGO
DRAIN
Fig. H.
Locked Mode
(Vandal Proof)
LOGO
DRAIN
Fig. G.
LOOP TOWARD
REAR OF SINK
2
1
RE-ATTACH
DISCONNECT
Fig. D.
REMOVE
CAM CAP
Thread CABLE CONNECTOR (1) clockwise
onto DRAIN BODY CONNECTION (2) and
hand tighten. Fig. A.
Your new POP-UP DRAIN installation is
now complete. Fig. B.
Note: Tailpeice on pop-up drain is 1-1/4” O.D.
Fig. B.
Fig. A.
ATTACH CABLE CONNECTOR
7
2
1
Fig. B.
1-1/4” O.D.
3
Fig. C.
STOPPER
1
DOWN
M961747-YYY0A
LIFT ROD
072574-0070A
EXTENSION ROD
066116-YYY0A
DRAIN STOPPER
M961711-0070A
TAILPIECE INSERT
070847-0070A
CLIP
066118-0070A
PIVOT ROD KIT
M953450-YYY0A
COMPLETE
DRAIN ASSEMBLY
070532-0040A
TAILPIECE
066117-YYY0A
2" FLANGE KIT
POP-UP DRAIN ASSEMBLY
BEFORE 01/07
1
3
4
5 6
2000.10X
2000.16X
Center -Set Lavatory Faucet
with Pop-up Drain
MODEL NUMBERS
2000.10X
2000.16X
T M
T M
© A m e r i c a n S t a n d a r d I n c . 2 0 0 2
Replace the "YYY" with
appropriate finish code
CHROME
WHITE
BONE
WHITE/CHROME
BLACK NICKEL
POLISHED BRASS
SATIN
SATIN/POL. BRASS
CHROME/POL. BRASS
002
020
021
025
062
099
295
297
299
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1-800 442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
Pr oduct n ames li sted he rein ar e tra de marks o f Ame ri can S ta ndard I nc.
IN MEXICO 01-800-839-12-00
2
1
5
2
4
1
Remove HANDLE (1), CAP (2), SCREWS (3) and
CARTRIDGE (4). Clean inlets and MANIFOLD (5).
Reassemble CARTRIDGE (4), alternately tightening
SCREWS (3). Replace CAP (2) and HANDLE (1).
Check flow.
If faucet drips, operate handle several times from
"off" to "on". Do not apply excessive force.
Clogged CARTRIDGE inlets may cause reduced flow
in "full on" hot or cold. To clean inlets, first turn off
water supply, then:
3
ADJUSTMENT WHEN
WATER IS TOO HOT
ADJUSTMENT WHEN
WATER IS TOO COLD
PRY RED RING FORWARD
AND ROTATE COUNTER-
CLOCKWISE ONE CLICK
PRY RED RING FORWARD
AND ROTATE CLOCKWISE
POINTER ON
HOT LIMIT STOP
"A"
"A"
"B"
"B"
RED RING HOT
LIMIT SAFETY
STOP
0
1
2
3
4
5
6
By restricting handle rotation and limiting the amount of hot
water allowed to mix with the cold, the HOT LIMIT SAFETY
STOP reduces risk of accidental scalding. To set the maximum
hot water temperature of your faucets, all you need
to do is adjust the setting on the HOT LIMIT SAFETY STOP.
Remove necessary trim parts. Use a flat blade screwdriver or
pull forward with your fingers to rotate red HOT LIMIT SAFETY
STOP. Follow Step "A" or "B" to adjust max./min. discharge
temperature. "0" being the hottest to "7" the coldest
temperature setting.
HOT LIMIT SAFETY STOP
IF FAUCET DRIPS
Fig. A.
M962430-0070A
CAM ASSEMBLY
M952430-0070A
CABLE ASSEMBLY
M952425-YYY0A
DRAIN ASSEMBLY
M962456-YYY0A
STOPPER
ASSEMBLY
M962457-YYY0A
FLANGE
ASSEMBLY
M962458-0070A
DRAIN MOUNTING KIT
A919661-0020A
TAILPIECE
M922872-0070A
CAM SEAT INSERT
M913207-0070A
TAILPIECE INSERT
M919660-0020A
6” TAILPIECE
(NOT INCLUDED
WITH FAUCET)
Thread FLANGE (1) counter-clockwise and remove
FLANGE (1) and FOAM GASKET (2) from drain
body. Fig. A.
Thread LOCKNUT (3) clock-wise to bottom of
drain body. Push GASKET (4) down against
LOCKNUT (3). Fig. B.
POP-UP DRAIN
Tighten TAILPIECE (4) on DRAIN BODY before
installing DRAIN BODY. Fig. B.
6
2
4
3
2
TIGHTEN LOCKNUT
1
REMOVE FLANGE
Remove CLEAR PLASTIC COVER (1).
Remove CARDBOARD SPACER (2) from under
DRAIN POP-UP (3).
2
2
3
3
1
2
4
3
1
9
1
Tighten LOCKNUT (1) firmly with Adjustable
Wrench or Channel Locks.
INSTALL DRAIN FROM
BELOW FIXTURE
5
From under side of SINK
install DRAIN BODY (1) up
through drain outlet.
Note: No plumber’s putty
or caulk is required.
The CABLE ATTACHMENT
POINT (2) must face towards
the rear of the SINK.
Install FOAM GASKET (3) and
FLANGE (4) onto drain body
from above SINK and tighten
FLANGE (4) firmly.
4
Fig. A. Fig. B.
Fig. A. Fig. B.
POP-UP KNOB (1) must be fully down. Fig. B.
FLANGE GASKET AND POP-UP KNOB
Check DRAIN FLANGE in SINK to ensure that
WHITE FOAM GASKET (3) is fully compressed
and not visible. Fig. A.
DRAIN
BODY
4
2
DRAIN
OUTLET
1
3
4
1
INSTALL FAUCET
Turn off hot and cold water
supplies before beginning.
CAUTION
GROOVE
(FAUCET
BASE)
6
4
7
5
Seat SEAL (1) into under side of FAUCET BASE (2).
Feed FAUCET SUPPLIES (3), MOUNTING STUD (4) and DRAIN
CABLE ASSEMBLY (8) through ESCUTCHEON (9) (optional) and the
mounting hole of lavatory or mounting surface. Fig. A.
From below, push GASKET (7) and RETAINING WASHER (5) onto
MOUNTING STUD (4). Secure Faucet with MOUNTING NUT (6),
pulling faucet to front of sink, so SUPPLIES (3) rests against
mounting hole. Before final tightening, make sure collar on
MOUNTING NUT (6) is seated into RETAINING WASHER (5).
Fig.B.
Adjust Faucet so that it is centered. Tighten MOUNTING NUT (6)
to complete faucet mounting.
REAR
OF SINK
Operate LIFT KNOB (1) to verify that STOPPER (2) opens and
closes.
Note: If STOPPER (2) does not open and close properly then
refer to the “troubleshooting section” of these instructions.
M 9 6 8 7 6 0 R e v . 1 . 3 M 9 6 8 7 6 0 R e v . 1 . 3 M 9 6 8 7 6 0 R e v . 1 . 3
M961741-YYY0A
HANDLE KIT
030126-0070A
HANDLE INDEX SET
A907086-YYY0A
CAP
918633-0070A
CARTRIDGE SCREWS
023529-0070A
CARTRIDGE KIT
M962492-0070A
MOUNTING KIT
911708-0070A
SEAL
M907671-YYY0A
ESCUTCHEON
M961745-0070A
MANIFOLD KIT
M962525-YYY0A
LIFT ROD
A922869-YYY0A
AERATOR
1
APPROX. 20"
2
COLD
HOT
3/8" COMPRESSION
RED
BAND
BLUE
BAND
Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies.
Connection on fitting supplies are 3/8" compression. Connect
left SUPPLY (1) to Hot (Marked with a Red Band) and right supply
to COLD (2) wall supply.
Faucet supplies are 20" long from faucet base.
Note: If additional supply length is required, installer must
purchase additional parts separately.
Important: If SUPPLY HOSES (1, 2) are to long, loop as
illustrated to avoid kinking.
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to
waste outlet.
1
4
7
Fig. B.
Fig. A.
Congratulations on purchasing your American Standard
faucet with Speed Connect drain, a feature found only on
American Standard faucets.
*Your new American Standard faucet is designed to work only with the Speed Connect drain. Heplful tips for
removing your current drain can be found in the Troubleshooting section of these instructions.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Speed Connect™ Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS:
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

American Standard 2000.100.002 Installation guide

Category
Sanitary ware
Type
Installation guide
This manual is also suitable for

American Standard 2000.100.002 is a Centerset Lavatory Faucet with Pop-up Drain. This faucet is designed to be easy to install, with a Speed Connect drain that requires fewer parts and installs in less time. The faucet also features a Hot Limit Safety Stop that reduces the risk of accidental scalding, and a durable construction that is sure to last for years to come. With its stylish design and convenient features, the American Standard 2000.100.002 is the perfect choice for any bathroom.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI