AGA Masterchef Gas Conversion Owner's manual

Type
Owner's manual
F200126 - 01
GB
FR
NL
DE
SE
NO
IT
IE
DK
PT
PL
RU
ES
FI
GR
Conversion to Another Gas
GB
FR
NL
DE
SE
NO
IT
IE
DK
PT
PL
RU
ES
FI
GR
Modification en vue de l’Utilisation d’un Autre Gaz
GB
FR
NL
DE
SE
NO
IT
IE
DK
PT
PL
RU
ES
FI
GR
Ombouwen voor Gebruik met een Andere Gassoort
GB
FR
NL
DE
SE
NO
IT
IE
DK
PT
PL
RU
ES
FI
GR
Umstellung auf Eine Andere Gasart
GB
FR
NL
DE
SE
NO
IT
IE
DK
PT
PL
RU
ES
FI
GR
Konvertering till en Annan Typ av Gas
2
Warning - Servicing to be carried out by an authorised person
Disconnect from electricity and gas before servicing.
Check appliance is safe when you have nished.
ArtNo.311-0034 - Burner head off
A
B
C
D
A - Burner head, B - Base, C - Brass venturi, D - Burner ring
Fig. 1.1
Fig. 1.2
Fig. 1.3
Fig. 1.4
Conversion to Another Gas
Servicing - Warning
This conversion must be performed by a competent person.
After conversion the installation must comply with the
relevant regulations and also the local electricity supply
company requirements. Read the instructions before
converting this appliance.
Failure to convert the appliance correctly could invalidate any
warranty or liability claims and lead to prosecution.
This instruction must be used in conjunction with the rest
of the appliance instruction, in particular for information on
Standards, cooker positioning, connection hose suitability etc.
When servicing or replacing gas-carrying components
disconnect from gas before commencing operation and
check appliance is gas sound after completion.
Do not use re-conditioned or unauthorised gas controls.
Conversion
Disconnect from electricity and gas before servicing. Check
appliance is safe when you have nished.
This appliance is supplied set for G20 natural gas at 20 millibar.
A conversion kit for other gases is supplied with the cooker.
Check in the table that the appliance can be converted to
your gas type.
Injectors
Remove pan supports and burner heads.
Remove burner heads. Undo the large brass nuts and remove
the brass venturis and brass rings (Fig. 1.1).
Use a long box spanner to access and remove the old injectors.
Using the rubber tubing, provided in the conversion kit, t
over the end of the socket wrench (Fig. 1.2).
Carefully push the open end of the tubing onto the orice
(Fig. 1.3). Unscrew the orice fully and lift clear of the cooktop.
Save the injectors removed from the appliance for possible
future use. Fit the new injectors, see the table (Table 1.1) for
the correct type.
Insert the new orice into the open end of the rubber tube
which is attached to the socket wrench. Screw into the orice
carrier as far as possible and lift the socket wrench away
(Fig. 1.4).
Remove the rubber tubing from the socket wrench and
tighten all of the orices.
Replace the rings on the burners. Screw in the hexagon
headed venturi to make tting the burners easier. DO NOT
tighten yet.
When all the burner bases and venturis have been tted
tighten the venturi nuts.
Rubber tubing
GB
FR
NL
DE
SE
NO
IT
IE
DK
PT
PL
RU
ES
FI
GR
3
Warning - Servicing to be carried out by an authorised person
Disconnect from electricity and gas before servicing.
Check appliance is safe when you have nished.
Tap adjustment
Pull o all the control knobs and timer buttons.
Open both oven doors and remove the xing screws
underneath and top rear of the control panel
Pull forward and gently lift the control panel. Rest the control
panel on a cloth to protect the control panel from any
damage
Bypass screw adjustment
Turn the bypass screw on each control clockwise all the way
till it stops (Fig. 1.5).
Fit the control panel, over and push the control panel into
position. Replace the xing screws you removed.Ret the
knobs.
GB
FR
NL
DE
SE
NO
IT
IE
DK
PT
PL
RU
ES
FI
GR
ArtNo.0102-0011 - Screwing
the control valve bypass screw
Fig. 1.5
B
B
A
B
C
Burner venturis
For some gases, the venturi tubes will have to be changed, from the
standard 10.5 mm ones, to the smaller 7mm internal diameter ones
found in the conversion kit. Look in the table to see if they need to
be changed for your gas.
Gas Group Pressure Burner Burner venturi Burner ring
2H, 2E, 2E+
Natural Gas
20 mbar
20/25 mbar
A 95 10,5mm No
B 120 10,5mm No
C 165 10,5mm No
2ELL
Natural Gas
20 mbar
A 102 7mm No
B 130 7mm No
C 173 10,5mm No
2L
Natural Gas
25 mbar
A 96 7mm No
B 123 10,5mm No
C 163 10,5mm No
3+
Liquid Petroleum Gas
28-30 & 37 mbar
A 64 10,5mm No
B 82 10,5mm No
C 107 10,5mm
Large ring in conversion kit
3B/P
Liquid Petroleum Gas
30 mbar
A 64 10,5mm No
B 82 10,5mm No
C 107 10,5mm
Large ring in conversion kit
3B/P
Liquid Petroleum Gas
50 mbar
A 53 7mm No
B 71 10,5mm No
C 92 10,5mm
Large ring in conversion kit
Table 1.1
10.5mm 7mm
4
Warning - Servicing to be carried out by an authorised person
Disconnect from electricity and gas before servicing.
Check appliance is safe when you have nished.
GB
FR
NL
DE
SE
NO
IT
IE
DK
PT
PL
RU
ES
FI
GR
Liquid Petroleum Gas
If you are converting to Liquid Petroleum Gas the burner ring
in the centre burner must be changed for the large ring in the
conversion kit (Fig. 1.6).