Important Safety Instructions
Read all safety information before operating the
equipment. Save these instructions.
Indicates a hazardous situation which, if not avoided, could result in
death or serious injury.
To reduce the risks of re or explosion, electrical shock and the
injury to persons, read and understand all instructions included in
this manual. Be familiar with the controls and proper usage of the
equipment.
WARNING: EXPLOSION OR FIRE
Solvent and paint fumes can explode or ignite. Property damage and/
or severe injury can occur.
PREVENTION:
• Donotsprayammableorcombustiblematerialsnearanopename,
pilotlightsorsourcesofignitionsuchashotobjects,cigarettes,motors,
electrical equipment and electrical appliances. Avoid creating sparks from
connecting and disconnecting power cords.
• Forunitsintendedforusewithonlywater-basedormineralspirit-type
materialswithaminimumashpointof38ºC(100ºF)—Donotsprayor
cleanwithliquidshavingaashpointoflessthan38ºC(100ºF).Flashpoint
isthetemperatureatwhichauidcanproduceenoughvaportoignite.
• Useextremecautionwhenusingmaterialswithaashpointbelow100ºF
(38ºC).Refer to your pump manual to determine if these materials can
be sprayed.
• Paintorsolventowingthroughtheequipmentisabletoresultinstatic
electricity. Static electricity creates a risk of re or explosion in the presence
ofpaintorsolventfumes.Allpartsofthespraysystem,includingthe
pump,hoseassembly,spraygunandobjectsinandaroundthesprayarea
shallbeproperlygroundedtoprotectagainststaticdischargeandsparks.
Useonlyconductiveorgroundedhigh-pressureairlesspaintsprayerhoses
speciedbythemanufacturer.
• Verifythatallcontainersandcollectionsystemsaregroundedtoprevent
static discharge.
• Connecttoagroundedoutletandusegroundedextensioncords(electric
modelsonly).Donotusea3to2adapter.
• Donotuseapaintorsolventcontaininghalogenatedhydrocarbons.Such
aschlorine,bleachmildewcide,methylenechlorideandtrichloroethane.
Theyarenotcompatiblewithaluminum.Contactthecoatingsupplier
aboutcompatibilityofmaterialwithaluminum.
• Keepsprayareawellventilated.Keepagoodsupplyoffreshair
moving through the area to keep the air within the spray area free from
accumulationofammablevapors.Keeppumpassemblyinwellventilated
area.Donotspraypumpassembly.
• Donotsmokeinthesprayarea.
• Donotoperatelightswitches,engines,orsimilarsparkproducingproducts
in the spray area.
• Keepareacleanandfreeofpaintorsolventcontainers,rags,andother
ammablematerials.
• Knowthecontentsofthepaintandsolventsbeingsprayed.Readall
materialSafetyDataSheets(SDS)andcontainerlabelsprovidedwiththe
paintsandsolvents.Followthepaintandsolventmanufacture’ssafety
instructions.
• Placepumpatleast25feet(7.62meters)fromthesprayobjectinawell
ventilatedarea(addmorehoseifnecessary).Flammablevaporsareoften
heavierthanair.Floorareamustbeextremelywellventilated.Thepump
contains arcing parts that emit sparks and can ignite vapors.
• Plasticcancausestaticsparks.Neverhangplastictoenclosesprayarea.Do
notuseplasticdropclothswhensprayingammablematerial.
• Fireextinguisherequipmentshallbepresentandworking.
WARNING: INJECTION INJURY
Ahighpressurepaintstreamproducedbythisequipmentcanpierce
theskinandunderlyingtissues,leadingtoseriousinjuryandpossible
amputation. See a physician immediately.
PREVENTION:
• Donotaimthegunat,orsprayanypersonoranimal.
• Keephandsandotherbodypartsawayfromthedischarge.Forexample,do
nottrytostopleakswithanypartofthebody.
• NEVERputyourhandinfrontofthegun.Gloveswillnotprovideprotection
against an injection injury.
• ALWAYSkeepthetipguardinplacewhilespraying.Thetipguardprovides
someprotectionbutismainlyawarningdevice.
• Onlyuseanozzletipspeciedbythemanufacturer.
• Usecautionwhencleaningandchangingnozzletips.Inthecasewherethe
nozzletipclogswhilespraying,ALWAYSlockguntrigger,shutpumpo,
andreleaseallpressurebeforeservicing,cleaningtiporguard,orchanging
tip.Pressurewillnotbereleasedbyturningothemotor.ThePRIME/
SPRAYvalveorpressurebleedvalvemustbeturnedtotheirappropriate
positionstorelievesystempressure.RefertoPRESSURERELIEFPROCEDURE
describedinthepumpmanual.
• Donotleavetheunitenergizedorunderpressurewhileunattended.
Whentheunitisnotinuse,turnotheunitandrelievethepressurein
accordancewiththemanufacturer’sinstructions.
• High-pressuresprayisabletoinjecttoxinsintothebodyandcauseserious
bodilyinjury.Intheeventthatinjectionoccurs,seekmedicalattention
immediately.
• Checkhosesandpartsforsignsofdamage,aleakcaninjectmaterialinto
theskin.Inspecthosebeforeeachuse.Replaceanydamagedhosesor
parts.OnlyuseTITANoriginal-high-pressurehosesinordertoensure
functionality,safetyanddurability.
• Thissystemiscapableofproducing3600PSI/248Bar.Onlyuse
replacementpartsoraccessoriesthatarespeciedbythemanufacturer
andthatareratedaminimumof3600PSI.Thisincludesspraytips,nozzle
guards,guns,extensions,ttings,andhose.
• Alwaysengagethetriggerlockwhennotspraying.Verifythetriggerlockis
functioning properly.
• Verifythatallconnectionsaresecurebeforeoperatingtheunit.
• Knowhowtostoptheunitandbleedpressurequickly.Bethoroughly
familiarwiththecontrols.Pressurewillnotbereleasedbyturningothe
motor.ThePRIME/SPRAYvalveorpressurebleedvalvemustbeturnedto
theirappropriatepositionstorelievesystempressure.RefertoPRESSURE
RELIEFPROCEDUREdescribedinthepumpmanual.
• Alwaysremovethespraytipbeforeushingorcleaningthesystem.
NOTE TO PHYSICIAN: Injection into the skin is a traumatic injury which can
lead to possible amputation. It is important to treat the injury as soon as
possible. DO NOT delay treatment to research toxicity. Toxicity is a concern
with some coatings injected directly into the blood stream. Consultation
with a plastic surgeon or reconstructive hand surgeon may be advisable.
WARNING: GENERAL
Cancausesevereinjuryorpropertydamage.
PREVENTION:
• Alwayswearappropriategloves,eyeprotection,clothingandarespiratoror
mask when painting.
• Donotoperateorspraynearchildren.Keepchildrenawayfromequipment
at all times.
• Donotoverreachorstandonanunstablesupport.Keepeectivefooting
andbalanceatalltimes.
• Stayalertandwatchwhatyouaredoing.
• Donotoperatetheunitwhenfatiguedorundertheinuenceofdrugsor
alcohol.
• Donotkinkorover-bendthehose.Airlesshosecandevelopleaksfrom
wear,kinkingandabuse.Aleakcaninjectmaterialintotheskin.
• Donotexposethehosetotemperaturesorpressuresinexcessofthose
speciedbymanufacturer.
• Donotusethehoseasastrengthmembertopullorlifttheequipment.
• Uselowestpossiblepressuretoushequipment.
• Followallappropriatelocal,stateandnationalcodesgoverningventilation,
re prevention and operation.
• TheUnitedStatesGovernmentSafetyStandardshavebeenadopted
undertheOccupationalSafetyandHealthAct(OSHA).Thesestandards,
particularlypart1910oftheGeneralStandardsandpart1926ofthe
ConstructionStandardsshouldbeconsulted.
• Beforeeachuse,checkallhosesforcuts,leaks,abrasionorbulgingofcover.
Checkfordamageormovementofcouplings.Immediatelyreplacehose
ifanyofthoseconditionsexist.Neverrepairapainthose.Replacewitha
conductivehigh-pressurehose.
• Donotsprayoutdoorsonwindydays.
• Alwaysunplugcordfromoutletbeforeworkingonequipment(electric
modelsonly).
for professional use only • instruction sheet
LX-75 ProfessionaL airLess gun
4’ gun 550-495
8’ gun 550-500
0318 • Form No. 313-2684E