De Dietrich EFU C 40 / EFU C 50 User manual

Category
Heat pumps
Type
User manual
EASYLIFE
S U S T A I N A B L E C O M F O R T
®
Neovo
MW-8000030-5
Jordan LebanonSyria
en
User Guide
Oil-fired Condensing Boiler
NeOvo Condens
EFU C 40
EFU C 50
Dear Customer,
Thank you very much for buying this appliance.
Please read through the manual carefully before using the product, and keep it in a safe place for later reference. In order to
ensure continued safe and efficient operation we recommend that the product is serviced regularly. Our service and customer
service organisation can assist with this.
We hope you enjoy years of problem-free operation with the product.
Contents
1 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.1 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.2 Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.3 Liabilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.3.1 Manufacturer's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.3.2 Installer's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.3.3 User's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
2 About this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.1 Symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.1.1 Symbols used in the manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.1.2 Symbols used on the appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
3 Technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.1 Homologations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.1.1 Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.1.2 Oil categories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
3.2 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
4 Description of the product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4.1 General description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
4.2 Main components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4.2.1 Boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4.3 Description of the control panel B-Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4.3.1 Description of the keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4.3.2 Description of the display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
4.4 Description of the control panel IniControl 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
4.4.1 Description of the keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
4.4.2 Description of the display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
5 Utilisation with the control panel B-Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5.1 Browsing in the menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5.2 Start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5.3 Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5.3.1 Switching off the heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5.3.2 Stopping domestic hot water production . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
5.3.3 Shutting down the installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
5.4 Frost protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
6 Utilisation with the control panel IniControl 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
6.1 Browsing in the menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
6.2 Start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
6.2.1 Description of the PCBs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
6.2.2 Selecting a PCB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
6.3 Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
6.3.1 Switching off the heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
6.3.2 Stopping domestic hot water production . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
6.3.3 Shutting down the installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
6.4 Frost protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
7 Control panel settings B-Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
7.1 List of parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
7.1.1 Information menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
7.2 Setting the parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
7.2.1 Setting the heating water temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
7.2.2 Modifying the domestic hot water temperature setpoint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
8 Control panel settings IniControl 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
8.1 List of parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
8.1.1 User Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
8.1.2 COUNTERS /TIME PROG / CLOCK menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
8.2 Setting the parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
8.2.1 Modifying the User parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Contents
7642053 - v05 - 31072017 EFU C 3
8.2.2 Setting the heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
8.2.3 Setting the domestic hot water temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
8.2.4 Setting the timer programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
8.2.5 Activating Manual Forcing for heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8.3 Reading out measured values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8.3.1 Control system sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
9 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
9.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
9.2 Maintenance instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
9.2.1 Check the hydraulic pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
9.2.2 Topping up the installation with water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
9.3 Venting the installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
10 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
10.1 Error messages B-Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
10.1.1 Error code display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
10.1.2 Fault code display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
10.2 Error messages IniControl 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
10.2.1 Error messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
10.2.2 Accessing the error log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
11 Environmental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
11.1 Disposal and Recycling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
11.2 Energy savings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
12 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
12.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
12.2 Terms of warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
13 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
13.1 Product fiche . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
13.2 Product fiche - Temperature Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
13.3 Product data sheet - Temperature controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
13.4 Product fiche . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Contents
4 EFU C 7642053 - v05 - 31072017
1 Safety
1.1 General safety instructions
Danger
This appliance is not intended for use by persons
(including children) with reduced physical, senso
ry or mental capabilities, or lack of experience
and knowledge, unless they have been given su
pervision or instruction concerning use of the ap
pliance by a person responsible for their safety.
Children should be supervised to ensure that they
do not play with the appliance.
Danger of electric shock
Before any work, switch off the mains supply to
the boiler.
Caution
Only genuine spare parts may be used.
Important
Only qualified professionals are permitted to in
stall the boiler, in accordance with prevailing local
and national regulations.
Important
Allow the space required to correctly install the
boiler. Refer to the Overall space needed for the
boiler section in the installation and service man
ual.
Warning
Do not touch the flue gas pipes. Depending on
the boiler settings, the temperature of the flue gas
pipes may exceed 60°C.
Warning
Do not touch the radiators for long periods. De
pending on the boiler settings, the temperature of
the radiators may exceed 60°C.
Warning
Take precautions with the domestic hot water.
Depending on the boiler settings, the domestic
hot water temperature may exceed 65°C.
Warning
Only qualified professionals are authorised to
work on the boiler and the heating system.
1 Safety
7642053 - v05 - 31072017 EFU C 5
Important
The installation must comply on all points with
prevailing regulations and directives, which gov
ern work and interventions in individual homes,
blocks of flats and other buildings.
Hydraulic safety
Important
Respect the minimum and maximum water inlet
pressure to ensure correct operation of the boiler:
refer to the chapter Technical Specifications.
Electrical safety
Caution
A disconnection method must be allowed in the
fixed pipes in accordance with the rules on instal
lation in force in the country.
Caution
If a power cord comes with the appliance and it
turns out to be damaged, it must be replaced by
the manufacturer, its after sales service or per
sons with similar qualifications in order to obviate
any danger.
Important
The installation must comply on all points with
prevailing regulations and directives, which gov
ern work and interventions in individual homes,
blocks of flats and other buildings.
Caution
The boiler must always be connected to the pro
tective earthing.
Earthing must comply with the prevailing instal
lation standards.
Earth the appliance before making any electrical
connections.
For the type and calibre of the protective equip
ment, refer to the chapter Electrical Connections
in the Installation and Service Manual.
Danger of electric shock
Only qualified professionals are permitted access
to the inside of the appliance, in accordance with
the prevailing electrical safety standard.
1 Safety
6 EFU C 7642053 - v05 - 31072017
Danger
If you smell flue gases:
1. Switch off the appliance.
2. Open the windows.
3. Evacuate the premises.
4. Contact a qualified professional.
Caution
Do not neglect to service the boiler. Contact a
qualified professional or take out a maintenance
contract for the obligatory annual servicing of the
boiler.
Failure to service the appliance voids the warran
ty.
Important
This manual can also be found on our internet
site.
1.2
Recommendations
Caution
The system must satisfy each point in the rules
(DTU, EN and others, etc.) that govern works and
interventions in individual homes, blocks of flats
or other buildings.
Note
Keep the boiler accessible at all times.
Caution
Install the boiler in a frost-free environment.
Note
Regularly check the presence of water and pres
sure in the heating installation.
Important
Never remove or cover labels and data plates af
fixed to the appliances. Labels and data plates
must be legible throughout the entire lifetime of
the appliance.
Damaged or illegible instructions and warning
stickers must be replaced immediately.
Important
Remove the casing only to perform maintenance
and repair work. Put the casing back in place af
ter maintenance and repair work.
1 Safety
7642053 - v05 - 31072017 EFU C 7
Important
Insulate the pipes to reduce heat losses to a mini
mum.
Caution
Have the boiler and heating system drained by a
qualified professional if the home is left empty for
a long period of time and there is a chance of
frost.
1.3
Liabilities
1.3.1
Manufacturer's liability
Our products are manufactured in compliance with the
requirements of the various Directives applicable. They
are therefore delivered with the
marking and any
documents necessary. In the interests of the quality of
our products, we strive constantly to improve them. We
therefore reserve the right to modify the specifications
given in this document.
Our liability as manufacturer may not be invoked in the
following cases:
Failure to abide by the instructions on installing the
appliance.
Failure to abide by the instructions on using the appli
ance.
Faulty or insufficient maintenance of the appliance.
1.3.2
Installer's liability
The installer is responsible for the installation and initial
commissioning of the appliance. The installer must ob
serve the following instructions:
Read and follow the instructions given in the manuals
provided with the appliance.
Install the appliance in compliance with prevailing leg
islation and standards.
Carry out initial commissioning and any checks neces
sary.
Explain the installation to the user.
If maintenance is necessary, warn the user of the obli
gation to check the appliance and keep it in good
working order.
Give all the instruction manuals to the user.
1 Safety
8 EFU C 7642053 - v05 - 31072017
1.3.3
User's liability
To guarantee optimum operation of the system, you
must abide by the following instructions:
Read and follow the instructions given in the manuals
provided with the appliance.
Call on a qualified professional to carry out installation
and initial commissioning.
Get your installer to explain your installation to you.
Have the required inspections and maintenance car
ried out by a qualified installer.
Keep the instruction manuals in good condition close
to the appliance.
1 Safety
7642053 - v05 - 31072017 EFU C 9
2 About this manual
2.1 Symbols used
2.1.1 Symbols used in the manual
This manual uses various danger levels to draw attention to special in
structions. We do this to improve user safety, to prevent problems and to
guarantee correct operation of the appliance.
Danger
Risk of dangerous situations that may result in serious personal
injury.
Danger of electric shock
Risk of electric shock.
Warning
Risk of dangerous situations that may result in minor personal in
jury.
Caution
Risk of material damage.
Important
Please note: important information.
See
Reference to other manuals or pages in this manual.
2.1.2 Symbols used on the appliance
1 Alternating current.
2 Protective earthing.
3 Before installing and commissioning the appliance, carefully read
the instruction manuals provided.
4 Dispose of used products through an appropriate recovery and re
cycling structure.
5 Caution: danger of electric shock, live parts. Disconnect the mains
power prior to carrying out any work.
6 Connect the appliance to the protective earthing.
Fig.1
1 2
MW-1000123-2
1
2
3
4
5
6
2 About this manual
10 EFU C 7642053 - v05 - 31072017
3 Technical specifications
3.1 Homologations
3.1.1 Certifications
The boiler complies with current standards.
CE identification number: 0085CQ0002
3.1.2 Oil categories
Tab.1
Type of oil that can be used Maximum viscosity
GNR
Non-road diesel with a maximum FAME content of 7 %
(1)
Note
To be used exclusively for a boiler fitted with a burner with a heater.
6 mm
2
/s at 20 °C
Standard fuel oil
6 mm
2
/s at 20 °C
Low-sulphur oil
6 mm
2
/s at 20 °C
Bio-oil B10
Mixture of low-sulphur oil (<50 mg/kg) plus 5.9 to 10.9% (in volume) of FAME
(1)
6 mm
2
/s at 20 °C
Bio-oil B5 (or Bio 5)
Mixture of low-sulphur oil (<50 mg/kg) plus 3 to 5.9% (in volume) of FAME
(1)
6 mm
2
/s at 20 °C
(1) Liquid petroleum products — Fatty Acid Methyl Esters used as heating fuel
3.2
Technical data
Tab.2 Technical parameters for boiler space heaters
Product name EFU C 40 EFU C 50
Condensing boiler Yes Yes
Low-temperature boiler
(1)
No No
B1 boiler No No
Cogeneration space heater No No
Combination heater No No
Rated heat output
Prated
kW 39 48
Useful heat output at rated heat output and high tem
perature regime
(2)
P
4
kW 38.5 48.2
Useful heat output at 30% of rated heat output and low
temperature regime
(1)
P
1
kW 12.1 15.1
Seasonal space heating energy efficiency
ƞ
s
% 88 89
Useful efficiency at rated heat output and high temper
ature regime
(2)
ƞ
4
% 90.2 90.4
Useful efficiency at 30% of rated heat output and low
temperature regime
(1)
ƞ
1
% 94.8 94.6
Auxiliary electricity consumption
Full load
elmax
kW 0.365 0.379
3 Technical specifications
7642053 - v05 - 31072017 EFU C 11
Product name EFU C 40 EFU C 50
Part load
elmin
kW 0.134 0.137
Stand-by
P
SB
kW 0.004 0.004
Other specifications
Standby heat loss
P
stby
kW 0.115 0.130
Ignition burner power consumption
P
ign
kW - -
Annual energy consumption
Q
HE
GJ 128 155
Sound power level, indoors
L
WA
dB 57 65
Emissions of nitrogen oxides NO
X
mg/kWh 90 91
(1) Low temperature means for condensing boilers 30°C, for low temperature boilers 37°C and for other heaters 50°C return temperature
(at heater inlet).
(2) High temperature regime means 60°C return temperature at heater inlet and 80°C feed temperature at heater outlet.
See
The back cover for contact details.
3 Technical specifications
12 EFU C 7642053 - v05 - 31072017
4 Description of the product
4.1 General description
Floor-standing condensing oil boilers from the EFU C range have the fol
lowing specifications:
Heating only with possibility to produce domestic hot water by combining
them with a domestic hot water tank
High-efficiency heating
Low polluting emissions
Heating body in cast iron
Condenser with ceramic pipes and stainless steel walls
Pre-assembled and pre-set oil burner
Electronic control panel
Flue gas discharge via a chimney type connection
4.2
Main components
4.2.1
Boiler
1
Control panel
2
On/Off switch
3 Access to the burner manual reset button
4
Data plate
4.3 Description of the control panel B-Control
4.3.1 Description of the keys
Heating temperature setting button
Level access key: Information, Installer or Chimney Sweep
Manual reset key
Domestic hot water temperature setting button
Fig.2
MW-5000451-1
2
1
3
4
Fig.3
MW-5000031-3
4 Description of the product
7642053 - v05 - 31072017 EFU C 13
4.3.2 Description of the display
Hour run meter
Malfunctions
Maintenance
Reset necessary
Burner status
Heating mode
Outside temperature sensor
Domestic hot water mode
4.4 Description of the control panel IniControl 2
4.4.1 Description of the keys
1
h
: back to the previous level without saving the modifications
made
: manual reset
2
: accessing the heating parameters
: lowering the value
3
: accessing the domestic hot water parameters
: raising the value
4
: MODE display
: accessing the menu selected or confirming the value modifi
cation
4.4.2 Description of the display
Burner Operation
Burner ON
Operating modes
Steady symbol: heating function enabled
Flashing symbol: heating production running
Steady symbol: domestic hot water function enabled
Flashing symbol: domestic hot water production running
Heating function disabled
Domestic hot water function disabled
Fig.4
MW-3000235-3
Fig.5
MW-1000043-5
1 2 3 4
Fig.6
MW-1000085-4
Fig.7
MW-1000083-5
4 Description of the product
14 EFU C 7642053 - v05 - 31072017
Menu display
Information menu: displays the measured values and the statuses
of the appliance
User menu: provides access to the User level setting parameters
Installer menu: provides access to the Installer level setting param
eters
Manual Forcing menu: the appliance runs at the set point dis
played, the pumps operate and the three-way valves are not con
trolled.
Malfunction menu: the appliance has malfunctioned. This informa
tion is signalled by an error code and a flashing display.
Sub-Menu COUNTERS
TIME PROG sub-menu: Timer programming dedicated to heat
ing and domestic hot water production
Sub-Menu CLOCK
PCB selection menu: access to information on the additional PCBs
connected
Display of PCB names
The name of the PCB for which the parameters are displayed is
shown as 3 characters.
CU-OH04 central unit PCB for the boiler
SCB-04B additional PCB: 2
nd
circuit
SCB-04C additional PCB: 3
rd
circuit
COUNTERS / TIME PROG / Sub-Menus CLOCK
COUNTERS sub-menu (CNT)
TIME PROG sub-menu: Timer programming dedicated to heat
ing and domestic hot water production (CIRC A, CIRC B, ECS)
Timer program for Monday
Timer program for Tuesday
Timer program for Wednesday
Timer program for Thursday
Timer program for Friday
Timer program for Saturday
Timer program for Sunday
CLOCK sub-menu (CLK)
Fig.8
Fig.9
MW-1000670-1
Fig.10
MW-1000683-2
...CUO / H04...
Fig.11
MW-1000687-1
...SCB / 04- / B...
Fig.12
MW-1000686-1
...SCB / 04- / C...
Fig.13
MW-1000575-2
4 Description of the product
7642053 - v05 - 31072017 EFU C 15
Temperature sensors
Outside temperature sensor connected:
fixed symbol for WINTER mode,
flashing symbol for SUMMER mode.
Other Information
Chimney Sweep Menu: forced operation in full load mode
Three-way valve connected
Three-way valve closed
Three-way valve open
Pump running
Fig.14
MW-1001083-1
Fig.15
MW-5000038-4
4 Description of the product
16 EFU C 7642053 - v05 - 31072017
5 Utilisation with the control panel B-Control
5.1 Browsing in the menus
Press any key to turn on the backlight for the control panel screen.
Important
If no key is pressed within 3 minutes, the backlight will go out.
The key is used to access the various menus:
Tab.3 Menus available
Information menu
Chimney Sweep menu
Press the key to access the Information menu.
Press the key for 2 seconds to access the Chimney Sweep menu.
Keep pressing the key to scroll through the information.
Note
Thirty minutes after the key is pressed for the last time, the dis
play reverts to the main display.
5.2 Start-up
If the boiler was powered off:
1. Check that the heating system and the boiler are adequately primed
with water. Recommended pressure between 0.15 and 0.2 MPa (1.5
and 2.0 bar).
2. Check that the storage tank is filled with fuel.
3. Open the oil inlet valve.
4. Switch on the boiler.
A venting cycle is run automatically.
The display shows the operating status of the boiler, the heating flow tem
perature and any error codes.
5.3
Shutdown
5.3.1 Switching off the heating
1. Turn the setting button all the way to the left until is dis
played.
Note
The frost protection function continues to run
Fig.16
Fig.17
MW-1000667-1
2’’
Fig.18
Fig.19
MW-3000241-3
5 Utilisation with the control panel B-Control
7642053 - v05 - 31072017 EFU C 17
5.3.2 Stopping domestic hot water production
1. Turn the setting button all the way to the left until is dis
played.
Note
Frost protection continues to run on the domestic hot water tank.
The venting cycle is not tripped when domestic hot water produc
tion is shut down.
For more information, see
Setting the timer programming, page 31
5.3.3 Shutting down the installation
It is recommended that the boiler is kept powered on to ensure frost pro
tection.
5.4
Frost protection
Caution
The frost protection function does not work if the boiler is powered
off.
Caution
The integrated protection system only protects the boiler, not the
heating system.
Caution
Have the boiler and heating system drained by a qualified profes
sional if the home is left empty for a long period of time and there
is a chance of frost.
Important
To prevent the radiators and the installation from freezing in pla
ces where that risk exists (e.g. in a garage or an equipment room),
we recommend the connection of an outside temperature sensor
to the boiler.
If the temperature of the water in the boiler falls too much, the integrated
protection device switches itself on. This device functions as follows:
If the water temperature is lower than 7°C, the circulation pump starts
up.
The water temperature is lower than 4°C, the boiler starts up and
switches off when the water temperature is above 35°C.
If the water temperature is higher than 10°C, the boiler shuts down and
the circulating pump continues to run for a short time.
Fig.20
MW-3000242-3
5 Utilisation with the control panel B-Control
18 EFU C 7642053 - v05 - 31072017
6 Utilisation with the control panel IniControl 2
6.1 Browsing in the menus
Press any key to turn on the backlight for the control panel screen.
Important
If no key is pressed within 3 minutes, the backlight will go out.
Press the 2 right-hand keys together to access the different menus:
Tab.4 Menus available
Information menu
User menu
Installer menu
Manual Forcing menu
Malfunction menu
COUNTERS sub-menu
TIME PROG sub-menu
CLOCK sub-menu
PCB selection menu
Note
The icon is displayed only if an optional PCB has
been installed.
Note
The different menus are only accessible when the icons flash.
Press the key to:
access the next menu,
access the next sub-menu,
access the next parameter,
increase the value.
Press the key to:
access the previous menu,
access the previous sub-menu,
access the previous parameter
decrease the value.
Press the confirmation key to confirm:
a menu,
a sub-menu,
a parameter,
a value.
When the temperature is displayed, briefly pressing the back key
h
will
return to the time display.
6.2
Start-up
If the boiler was powered off:
1. Check that the heating system and the boiler are adequately primed
with water. Recommended pressure between 0.15 and 0.2 MPa (1.5
and 2.0 bar).
2. Check that the storage tank is filled with fuel.
3. Open the oil inlet valve.
Fig.21
MW-2000369-1
Fig.22
MW-1000576-1
Fig.23
MW-2000370-1
Fig.24
MW-2000371-1
6 Utilisation with the control panel IniControl 2
7642053 - v05 - 31072017 EFU C 19
4. Switch on the boiler.
A venting cycle is run automatically.
The display shows the operating status of the boiler, the heating flow tem
perature and any error codes.
6.2.1 Description of the PCBs
When commissioning the boiler, the PCB displayed is the CU-OH04.
The primary circuit is managed by the CU-OH04 central unit PCB. The
name of the PCB is displayed on the screen: .
See
Boiler instructions for setting the boiler parameters
Only the installer can access the parameters and settings for each PCB.
In order to control an installation that has an additional circuit, it will be
necessary to install the SCB-04 PCB. The name of the PCB is displayed
on the screen:
.
Note
Given that numerous settings can be made on the 2 PCBs, de
pending on the circuit concerned, the name of the PCB will be rep
resented by in the rest of the manual.
6.2.2
Selecting a PCB
1. Access the menus by pressing the two keys on the right simultane
ously.
2. Access the PCB selection menu (only when several PCBs are
present).
Important
The PCB selection menu is available only when the icon flash
es.
3. Scroll through the names of the connected additional PCBs by
pressing the
or keys.
The names of the installed PCBs will be displayed in sequence.
4. Confirm the required PCB by pressing the key.
Note
The flow temperature for the selected PCB is displayed by default,
as well as the status of the pump(s) and the status of the valve
connected to the selected PCB.
5. Go back to the main display by pressing the
h
key.
For more information, see
Modifying the User parameters, page 30
User Menu, page 26
COUNTERS /TIME PROG / CLOCK menus, page 28
Fig.25
MW-1001085-1
...CU- /-OH /-04...
Fig.26
Management of a second
circuit
MW-1001084-1
...SCb /-04 /-B...
Fig.27
MW-2000369-1
Fig.28
MW-5000137-2
MW-5000137-2
6 Utilisation with the control panel IniControl 2
20 EFU C 7642053 - v05 - 31072017
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

De Dietrich EFU C 40 / EFU C 50 User manual

Category
Heat pumps
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI