Safety Device Wiring Manual
Closed Gate
Wall / Fence Close Beam
Entrapment Area
OPEN BEAM
TRANSMITTER SOLUTIONS PHOTO EYES TRANSMITTER SOLUTIONS PHOTO EYES
123 4 567
12- 30V DC/AC 60 Hz
NC
NC
NO
COM
TP1
TP2
Non polarity
Dip Switch 1: ON
10kΩ
Resistor
UL 325
Terminal
UL 325 DIP-Switches
1
Closed Gate
Wall / Fence
Open Beam
Entrapment Area
OPEN Beam Stop: Obstructed opening-direction photo beam
will stop the gate during the opening-direction only. Gate will resume
the open cycle when the obstructed photo beam has been cleared.
In addition to the inherent reversing sensor system, this operator has a UL 325 terminal for the connection of photo sensors-Type B1
and/or reversing edges-Type B2 entrapment protection required by UL 325 standards. At least ONE external entrapment protection
device MUST be installed or the operator will NOT function. Install these devices where the risk of entrapment or a safety hazard exists,
examples of which are shown below. Specific installations will vary.
2CLOSE Beam Reverse: Obstructed closing-direction photo
beam will reverse the gate to the open position and reset the close-timer
during the closing-direction only. Gate will close when timer times out.
External Entrapment Protection Devices:
DOORKING® - Entrapment and Safety Protection
Only 1 monitored Device can
be connected to each input.
An OPTIONAL Expansion Kit
(sold separately) will allow
connection for additional devices.
Common
Full Open
24 VDC
GND
GND
CE
OE
CB
OB
1 2 3 4 5 6
7 8 9 10
1234
ON
CLOSED BEAM
123 4 567
12- 30V DC/AC 60 Hz
NC
NC
NO
COM
TP1
TP2
Non polarity
Dip Switch 2: ON
10kΩ
Resistor
UL 325
Terminal
UL 325 DIP-Switches
iGAZE: R50LR-UL, R32P-UL, SR66HD, or SR33HDiGAZE: R50LR-UL, R32P-UL, SR66HD, or SR33HD
Common
Full Open
24 VDC
GND
GND
CE
OE
CB
OB
1 2 3 4 5 6
7 8 9 10
1234
ON
1234567 8
ON
12345678
ON
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
EXIT
LOOP
REVERSE
LOOP
IN POWER/BATT
PWR
SEL
REV SENSE
JUMPER ON
SOLAR MODE
P3
SELF TEST
RESET
RED=CHARGING
GREEN=CHARGED
KEY
SWITCH
NO
NC
3 BUTTON
CONTROL
SW1
SW2
OFF ON
POWER
P4
P2
61
TIME DELAY
1 2 3 4 5 6 7 8 9 10
1234
ON
OPEN BEAM
CLOSE BEAM
OPEN EDGE
CLOSE EDGE
DIP-switches
MUST be turned
ON for each device
wired to terminal.
1234
ON
OPEN BEAM
CLOSE BEAM
OPEN EDGE
CLOSE EDGE
ONLY connect
monitored devices.
Connect ONLY MONITORED Devices
Ground (Common)
Ground (Common)
CLOSE Edge
OPEN Edge
CLOSE Beam
OPEN Beam
Note:
All safety devices are wired to the
primary operator when using dual
gate operators.
1 2 3 4 5 6 7 8 9 10
UL 325 Terminal
DoorKing 9024 20-PIN
Main Terminal