Astria Fireplaces BRT40 Instruction Sheet

Category
Fireplaces
Type
Instruction Sheet
AK4 OUTSIDE COMBUSTION AIR KIT
[FOR USE WITH APPLIANCE MODELS MISSION36/42, ALPHA32/36, MARQUEE36/42/50, TAURUSST/PF, VALIANT32, VEGA32/36/42, PLANTATION48, GEORGIAN36/42/50, INGLENOOK36, WINSDORST, MONTEREYPF,
CRAFTSMANST, CRAFTSMAN36/42, BRT4536/42, BRT4336/42, BRT4536/42, BRT4036/42, BRT2532/36, BRT2032, BRT2332, VRT4032/36, VCT4032/36, VCM3026, VRT6036/42/50, VRT4536/42/50, VRT43ST/PF, VRT3032/36/42,
VCT3032/36/42, VRT2036/42, VCT2036/42, WRT6842/50, WRT6036/42/50, WRT4842/50, WRT4536/42/50, WRT40CR/CL, WCT40CR/CL, WRT40ST/PF, WRT35ST, WRT3836, WCT3836, WRT3036/42, WCT3036/42, WRT2036/42,
WCT2036/42, BELMONT36/42/50, COLUMBUS36/42, BLACKSTONE36/42, BARKLEYST/PF, CUMBERLAND32/36/42, OAKRIDGE36/42]
AK4 OUTSIDE COMBUSTION AIR KIT
P/N 127169-01
Rev. B, 03/2017
HEARTH PRODUCTS
KITS AND ACCESSORIES
GENERAL INFORMATION
Combustion Air Kit model AK4 is designed to provide outside air to
the fi re for combustion.
READ ALL THE STEPS BEFORE STARTING THE INSTALLATION
THE FIREPLACE MUST BE OFF AND COLD BEFORE BEGINNING.
ALL WARNINGS, PRECAUTIONS AND INSTRUCTIONS IN THE
INSTALLATION AND OPERATION MANUAL PROVIDED WITH THE
APPLIANCE APPLY TO THESE INSTRUCTIONS.
If you encounter any problems, need clarifi cation of these instructions
or are not qualifi ed to properly install this kit, contact you local
distributor or dealer.
If any of these parts are missing or damaged, contact your dealer or
IHP.us.com for referral information.
KIT CONTENTS
1 ea. Collar
1 ea. Hood
1 ea. Flex Duct, 4" x 3'
1 ea. Instruction Sheet
Cat. No. Model Description
F1091 AK4 Complete 4" Air Kit with Collar, Hood and 3' Flex
1
INSTALLATION INSTRUCTIONS
1. Locate air inlet cover plate on fi replace's outer surround and remove
it. Cut-out any visible insulation that may obstruct air fl ow. Air inlet
tube may be installed in two positions (Figure 2) (AK4E only). In-
sert inner tab of inlet tube into the mating slot next to the opening
(Figure 1). Place outer tab of inlet tube over mating hole next to the
opening and secure with a screw previously removed from cover
plate. Seal any remaining gaps around inlet tube with hi-temp duct
tape or noncombustible sealant (Figure 3 or 4).
2. Construct a 4 1/2" x 4 1/2" framing or opening on exterior wall (see
Figure 3 or 4). Install the outside air vent termination in a location
that would not eventually be obstructed by bushes, snow, or other
obstructions.
Also, locate the vent near the fi replace to make fl ex duct instal-
lation easier. The fl ex duct supplied measures approximately 10"
compressed and up to approximately 3 feet extended (Figures 3 or
4).
Be very careful not to distort fl ex duct when extending and watch for
sharpness at the edges (use gloves). Slip fl ex duct onto inlet collar
and vent collar. Clean fl ex duct surface of oil and dirt at the ends
and secure fl ex duct to collars with hi-temp duct tape to provide a
good seal.
Cut Out Any
Visible
Insulation
Insert Inner Tab of
Inlet Tube into Slot
on Outer Surround
Figure 1
CAUTION
AIR INLET DUCTS ARE NOT TO TERMINATE IN ATTIC
SPACE.
DO NOT INSTALL VENT TERMINATION IN A LOCATION
THAT WOULD DRAW AIR FROM GARAGE OR ATTIC
SPACES.
NOTICE
The maximum height for the air vent can not exceed
3 feet below the fl ue gas outlet of the termination.
IHP.us.com
2
Figure 3
Figure 4
Figure 2
Seal with Hi-Temp Duct Tape
Air Inlet Tube
Air Vent
Flex Duct
Flex duct extends
up to 3 feet
Air vent location must allow for bushes, snow,
and other possible obstructions
4-1/2" x 4-1/2"
Framed opening
Outside air vent
termination
Secure and seal duct to col-
lars with hi-temp duct tape
(both ends) remove oil at
ends of duct to ensure proper
adhesion of duct tape to be
applied
Seal gaps with non-
combustible hi-temp
sealant or duct tape
Secure and seal duct to collars
with hi-temp duct tape (both
ends). Remove oil at ends of
duct to ensure proper adhe-
sion of duct tape to be applied
Flex duct extends up
to 3 feet
Air vent location must allow for
bushes snow and other possible
obstructions
Remove Air inlet
cover (2 screws) Cut and remove any
blocking insulation
Bend tabs out
before installing
Outside air vent termination
Tabs
Printed in U.S.A. © 2014 Innovative Hearth Products
P/N 127169-01 Rev. B 02/2017
IHP reserves the right to make changes at any time, without notice, in design, materials, specifi cations, prices and also to discontinue colors, styles and products. Consult your local distributor for
replace code information.
IHP
1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210
  • Page 1 1
  • Page 2 2

Astria Fireplaces BRT40 Instruction Sheet

Category
Fireplaces
Type
Instruction Sheet

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI