General safety instructions
The device must only be used in accordance with its intendedpurpose
and within the scope of the specications.
The measuring tools and accessories are not toys.
Keep out of reach of children.
Modications or changes to the device are not permitted, this will
otherwise invalidate the approval and safety specications.
Do not expose the device to mechanical stress, extreme temperatures,
moisture or signicant vibration.
Safety instructions
Using class 2 lasers
Attention: Do not look into the direct or reected beam.
– Do not point the laser beam towards persons.
If a person‘s eyes are exposed to class 2 laser radiation, they should shut
their eyes and immediately move away from the beam.
Laser radiation!
Do not stare into the beam!
Class 2 laser
< 1 mW · 635 / 650 nm
EN 60825-1:2014
09
Function / Application
Cross-line laser vertical and horizontal alignment
The pivoted housing can be turned with a vernier adjustment
mechanism to permit exact positioning of laser lines.
– Adjustable feet with removable rubber caps
– Automatic levelling range 2.5°, accuracy 0,2 mm / m
A simple, precise plumb function is afforded by the additional
plumb laser at the bottom and the laser cross at the top.
The vertical lines are aligned at right angles to one another.
EN
Under no circumstances should optical instruments (magnifying glass,
microscope, binoculars) be used to look at the laser beam or reections.
– Do not use the laser at eye level (1.40 ... 1.90 m)
Reective, specular or shiny surfaces must be covered whilst laser devices
are in operation.
In public areas shield off the laser beam with barriers and partitions
wherever possible and identify the laser area with warning signs.
Safety instructions
Dealing with electromagnetic radiation
The measuring device complies with electromagnetic compatibility
regulations and limits in accordance with the EMC Directive 2014/30/EU.
Local operating restrictions – for example, in hospitals, aircraft, petrol
stations or in the vicinity of people with pacemakers – may apply. Electronic
devices can potentially cause hazards or interference or be subject to hazards
or interference.
10
Special product features
Automatic alignment of the device with a magnetically
dampened pendulum system. The device is brought into initial position
and aligns itself autonomously.
Transport LOCK: The device is protected with a pendelum
lock during transport.
Devices with PowerBright technology have special high-
performance diodes to produce super bright laser lines These remain
visible over longer distances, in bright ambient light and on dark surfaces.
RX-READY technology enables line lasers to be used even in
unfavourable light conditions.The laser lines pulsate at a high frequency
and this can be picked up by special laser receiversover long distances.
EN
AutoCross-Laser 3C
1H 2V 1D
6
3
2
5
4
1
7
10
8
9
11
12
11
For transport, the device must
always be switched off with the
transport securing device (2) so
as to protect device from damage.
!
1
Laser emitting window
2
ON / OFF switch;
Transport fastener
3
Vernier adjustment
4
5/8” thread (bottom)
5
Window for plumb laser (bottom)
6
Adjustable feet with
removable rubber caps
7
Tripod adapter
8
Vial for approximate alignment /
Low bat. display: Low battery
charge when bubble level flashes
9
Rechargeable battery
compartment
(ACL 3C Pro) /
Battery compartment (ACL 3C Plus)
10
Hand receiver mode
11
Horizontal laser lines
12
Vertical laser line
EN
Inserting the batteries
Open the battery compartment (9) and insert
the batteries in accordance with the installa-
tion symbols, ensuring the correct polarity.
1
Number and direction of the lasers
H = horizontal laser
V = vertical laser
D = downpoint
12
4
2
Hand receiver mode
Optional: Working with the laser receiver RX
Use an RX laser receiver (optional) to carry out levelling at great distances or
when the laser lines are no longer visible.
To work with a laser receiver, switch the line laser into hand receiver mode
with the Hand receiver mode button (10). The laser lines will now pulsate
with high frequency, making the laser lines darker. The laser receiver RX
can detect these pulsating laser lines.
Observe the laser receiver‘s operating instructions for line lasers.
!
Horizontal and vertical levelling
Turn the transport fastener (2) clockwise and release the pendulum lock.
The lasers are now automatically aligned by the pendulum system and the
horizontal laser lights constantly. The lasers can be switched on and off
individually with the H and V buttons. It is now ready for levelling in the
horizontal or vertical plane.
If the device is too far off the horizontal (more than 2.5°), the lasers
will blink. Align the device using the adjustable feet (6) or place on a
more level surface. The round vial (8) is provided as an aid to alignment.
!
Positioning laser lines
The top section of the laser unit can be turned on the plinth to align the
lasers approximately. Precise positioning can then be done with the Vernier
adjustment (3). The adjustable feet (6) allow the device to be positioned on
sloping surfaces.
3
EN
AutoCross-Laser 3C
13
A1
A2
2.
1.
Preparing the calibration check:
It is possible for you to check the calibration of the laser. To do this, position
the device midway between 2 walls, which must be at least 5 metres apart.
Do this by turning the unit on, thus releasing the transport restraint (cross
laser on). Please use a tripod.
1. Mark point A1 on the wall.
2. Turn the device through 180° and mark point A2.
You now have a horizontal reference between points A1 and A2.
A3
A2
A2
A1
4.
3.
A3
A2
<
0,2 mm / m = OK
Performing the calibration check:
3. Position the device as near as possible to the wall at the height
of point A1.
4. Turn the device through 180° and mark point A3. The difference
between points A2 and A3 is the tolerance.
When A2 and A3 are more than 0,2mm / m apart, an adjustment
is necessary. Contact your authorised dealer or else the UMAREX-
LASERLINER Service Department.
!
EN
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents,
scouring agents and solvents. Remove the battery(ies) before storing for
longer periods. Store the device in a clean and dry place.
Calibration
The meter needs to be calibrated and tested on a regular basis to ensure
it produces accurate measurement results. We recommend carrying out
calibration once a year.
14
B
C
2,5 m
< 1 mm = OK
Checking the vertical line:
Position the device about 5 m from a wall. Fix a plumb bob with a line of 2.5 m
length on the wall, making sure that the bob can swing freely. Switch on the
device and align the vertical laser to the plumb line. The precision is within
the specified tolerance if the deviation between the laser line and the plumb
line is not greater than ± 1 mm.
Checking the horizontal line:
Position the device about 5 m from a wall and
switch on the cross laser. Mark point B on the
wall. Turn the laser cross approx. 2.5 m to the
right and mark point C. Check whether the
horizontal line from point C is level with point B to within ± 1 mm.
Repeat the process by turning the laser to the left.
Regularly check the adjustment before use, after transport and after
extended periods of storage.
!
EN
AutoCross-Laser 3C
15
Technical data (Subject to technical alterations. 10.2017)
Self-levelling range ± 2,5°
Precision ± 0,2 mm / m
Laser wavelength linelaser / plumb laser 635 nm / 650 nm
Laser class 2 / < 1 mW
Power supply 3 x 1,5V AA
Operating time approx. 16 h
Operating conditions
0 ... 50°C, Max. humidity 80% rH,
no condensation, Max. working
altitude 4000 m above sea level
Storage conditions
-10 ... 70°C,
Max. humidity 80% rH
Weight (incl. batteries) 1,4 kg
Dimensions (W x H x D) 120 x 190 x 120 mm
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must be collected
separately for disposal according to the European
Directive on waste electrical and electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=acl3c
EN
AutoCross-Laser 3C
65
AutoCross-Laser 3C
67
AutoCross-Laser 3C
SERVICE
Umarex GmbH & Co. KG
– Laserliner –
Möhnestraße 149, 59755 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: +49 2932 638-333
info@laserliner.com
Umarex GmbH & Co. KG
Donnerfeld 2
59757 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: -333
www.laserliner.com
8.031.96.23.1 / Rev.1017
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68

Laserliner AutoCross-Laser 3C Owner's manual

Category
Laser levels
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI