Vetus VH4.65/4.80 Installation guide

Type
Installation guide
Installation
instructions
MP34
VH4.65
VH4.80
A
X4X3
X2
X6X5
STM6911
B B
Engine control panel c/w panel wiring
MPVB2
MP34BS12
MP34BN12
MPKA02
MPKB02
MPKA04 MPKA06
MPKB04 MPKB06
L = 2 m L = 4 m L = 6 m
MPKA12
MPKB12
L = 12 m
'34'
A B
MP34BS125
B
X2
C
X3
M2/M3
AD14-16
+ STM1062
+ STM7953
STM6341
M4
AD14-16
+ STM1062
+ STM7953
STM7581
Temp. switch and
oil pressure switch
Sending units to be installed
M2.C5
M2.D5
M2.06
M3.09
M4.15
M4.17
VH4.65
VH4.80
Standard Linea Nost.
VH4.80
Standard
M2.C5
M2.D5
M2.06
M3.09
M4.15
M4.17
VH4.65
Intermediate loom
Interface
Interface cable
STM8326
CT40083
Temperature sending unit Oil pressure sending unit
When using a panel model ‘34’ both warning lights and meters, for coolant temperature and oil pressure have to
be operated.
Installation of both switches for warning lights and sending units for meters into the engine block is not possible.
Therefor some minor modifications have to be carried out:
- At the panel the factory installed connection cables (X2->B and X3->C) have to be replaced by an interface
[STM 6911] and an interface cable [MPVB2].
- At the engine the factory installed switches have to be replaced by sending units, adaptors and washers are
required.
353102.01 (STM6965)
VH4.65
Replacing switches for send-
ing units
- On engine, loosen wire nr.
B5 (blue) from the thermo
switch.
Replace factory installed ther-
mo switch by: Temperature
sending unit, adaptor and
copper washers. Reconnect
wire B5 to temperature sen-
sor.
- Loosen wire nr. B2 (brown)
from the oil pressure switch.
Replace factory installed oil
pressure switch by: Oil pres-
sure sending unit, adaptor,
adaptorblock, bolt and wash-
ers. Reconnect wire B2 to oil
pressure sensor.
X2 - B
X3 - C
MPVB2MPVB2
STM6911
X2 - B
X3 - C
On panel, remove connection cables, X2 B and
X3 C, from warning light printed circuit board (pcb).
Install interface pcb [STM6911] onto warning light pcb.
Connect Interface cable [MPVB2] to warning light pcb
and to interface pcb.
Installation of interface and interface cable on ‘34’ model panel
STM8326
STM1062
VH4.65
VH4.80
CT40083
STM7580
STM2018
STM6341
STM2018
STM7582
STM7581
Max. 10 Nm
(89 lb.in.)
353102.01 (STM6965) 07-2012 Printed in the Netherlands
FOKKERSTRAAT 571 - 3125 BD SCHIEDAM - HOLLAND - TEL.: +31 10 4377700