IMPORTANT, PLEASE READ.
This is an electrical appliance, use appropriate precautions
to reduce risk of fire, electrical shock or injury.
• Read all instructions before installing / using the unit.
• Do not use outdoors unless in protected area. (inquire)
• To disconnect unit, turn control OFF and disconnect
power at the service panel.
Always use a licensed electrician should new circuits or
outlets be needed.
• Disconnect power supply before performing any cleaning,
maintenance or relocation of unit.
INSTALLATION / ELECTRICAL
The AQ1000 and AQ500 come ready for hard wire installation
& manually lled water containers. (can be direct plumbed)
! NOTE :: A 15 Amp, 120 Volt circuit is required. A dedicated
circuit is preferred but not required.
Keep unit in OFF position before connecting electrical power.
! NOTE :: When preparing the opening for the unit provide
at least 1⁄4 inch of clearance from each side to make
installation easier.
Caution :: Use two conductor, non-metallic sheath
cable with ground wire (3 wires total) for incoming power
supply on cassette. Use appropriate wire to meet local and
national electrical codes for rated power.
! NOTE :: When installing multiple units in same
vicinity they will need to be wired in parallel.
The AQUAFIRE cassette allows for installation of a wall
switch to control incoming power to unit.
Connect black wire (live) from unit to live wire from power
supply. Connect white wire (neutral) from unit to neutral
wire from power supply. Connect green wire (ground) from
unit to ground wire from power supply.
Place all connectors inside unit and secure cable clamp
to unit, making sure that cable clamp grips only jacket of
service cable.
! Warning :: Ensure wiring is not pinched or against a sharp
edge, ensure power wiring is stored to avoid tripping or
snagging to reduce re risk, electric shock or injury.
Optional Direct Plumbing (see Figure 2)
Units are designed to be manually lled or direct plumbed.
One 1/4“ waterline can supply water for up to four units in
series. More than four units will require additional water lines.
• Use self-tapping saddle valve for 1/4“ copper
water water lines (recommended).
All plumbing connections should comply with
local building codes.
• Locate plumbing connection for easy access allowing
shut off during maintenance.
• Connect to cold water line.
• Use normal tap water. If water is ‘hard’, soften or lter it.
• Be sure tubing is cut square to prevent leaking.
Verify all connections are fully inserted and begin opening
each of the valves, checking for leaks.
! NOTE :: Unit has three levels of water control management.
Lumina Products Inc
www.luminaproducts.com
sales@luminaproducts.com
p: +1 877.395.0888
AQ1000 40“ AQUAFIRE MODULE
AQ500 20“ AQUAFIRE MODULE
AQUAFIRE MANUAL + SETUP GUIDE
IMPORTANT :: For your safety, read this manual rst before
attempting to install or use this AQUAFIRE unit. Failure to
comply with all warnings and safety instructions contained
in this manual could result in personal injury or property
damage. If you have questions, please call 877.395.0888.
Figure 1
Optional Direct Plumbing (continued)
New Construction:
Locate AQUAFIRE unit where effects of drafts, vents, ceiling
fans and air currents are minimized. If located where
air movement disrupts ame, a glass fence up to 10“ in
height can used to optimize performance. See Figure 3.
Building an enclosure.
• Use studs to frame and enclosure. (see Figure 3).
• Minimum air intake (from below) is 100 square inches
for AQ1000 and 50 square inches for AQ500 in order to
perform properly. More air intake is better.
• Electrical Connection. In back left corner of unit, locate
and remove electrical cover plate. (two screws)
• Install a 3⁄8 in. or 1⁄2 in. cable connector, not included,
suitable for mounting in a 7⁄8 in. hole, to cable plate and
feed supply cable through the connector.
Install into roughed-in framing so that unit is resting on two
framing sills, one at front & one at back on a level surface.
Level housing / right - left, front - back, using adjustable feet.
Secure unit to permanant framing using a minimum of
two holes located at each end. (Figure 1)
After surrounding area is completed, install tethered
controller into jack & run cord around internal components
and out through small opening in back panel. (Figure 1)
Locate tethered controller so: (a) it can be easily accessed, if
being used as main control, or (b) it is not obscured by brick,
stone or sheet metal that blocks signal from remote.
• Initialize the tethered controller to the remote.
Fill the unit:
• Rell Container(s): remove ll cap assemblies from inlet
to the reservoir tanks, then install rell container(s).
! NOTE :: During initial installation, water from rell container
will ll the reservoir; ll rell container a second time to
maximize operating time.
Hard Plumbed - prime reservoir(s) with 1 Quart (1L) water.
! NOTE :: Use normal tap water for AQUAFIRE unit(s). If
water is hard, soften water with 1/8 tsp of salt (0.5 ml)
added to water reservoir. (Only add more salt if you notice
unit is not producing mist as expected.)
! NOTE :: If rocks or other decorative materials are used
on top of units be carefull small particles cannot fall into
unit. Decorative objects should not exceed 5 lbs ,if so,
use Lumina AQUAFIRE Tray.
Bathroom Installation ::
AQUAFIRE must be protected by an accessable GFI circuit
to reset circuit if necessary. AQUAFIRE is not a watertight
electrical appliance. Prevent water from entering unit and
keep away from showers, tubs, etc.
Operation ::
Three different control options are available for unit:
(1) manual buttons (under media tray), (2) tethered controller
(must be connected to unit) and (3) remote control.
AQ1000 unit has two separate internal modules that are
controlled by settings entered on left side (primary). Fine
adjustment can be done using controls on right module to
have both modules operating at same level (secondary).
! NOTE :: When unit is used in a quiet environment, it
may be possible to hear a sound related to operation of
AQUAFIRE unit. This is normal and not a cause for concern.
! NOTE :: Always ensure appliance is xed to framing in a
level position.
Figure 2
Figure 3
Figure 4
Controls
! NOTE :: Icons with 1 dot indicate controls for primary and 2
dots indicate controls for secondary. Secondary controls
are not applicable for the AQ500.
A. On/Off Switch Supplies power to unit.
! NOTE :: When unit is rst turned on lights will come on
and mist will appear 45 seconds later.
B. Standby
Puts unit into standby mode where control by tethered
controller or remote is possible.
C. Blue tooth
Required for initializing remote, see initialization instructions.
D. Test Mode
Used for troubleshooting issues, see Troubleshooting.
E. Flame Intensity Control
Adjusts intensity of ame and smoke effect when unit has
been activated. Pressing will decrease ame effect and
pressing will increase ame.
! NOTE :: Allow one minute after adjustment to notice a change.
! NOTE :: During normal operation expect to see some
condensation of water on media tray. This will vary
depending on ambient conditions and is normal.
! NOTE :: When water tank is empty unit will turn OFF after
30 seconds.
F. Volume Control
Adjusts volume of wood re sound effects.
On the unit: Pressing will decrease volume and
pressing will increase volume.
On the Remote and Tethered Controller: Pressing turns
volume On and Off.
Remote Control
Tethered controller is used in same manner as remote but
houses blue tooth receiver for communication with remote.
Tethered controller must be connected and On/Off
Switch must be in ‘ON’ ( I ) position for remote to operate.
! NOTE :: To operate correctly remote control must be
initialized with unit.
Remote Control Initialization / Reprogram
For remote to communicate with unit blue tooth must be
setup, as outlined below:
1. Install tethered controller - plug into port and run wire
out of housing through opening in center of back panel.
2. Place On/Off Switch (Figure 5-callout A) in ON (“I”) position.
3. Press blue tooth initialization button on Primary controls
(left side).
4. Unit will beep and turn lights ON & OFF every 2.5 seconds
to indicate unit is in synchronization mode.
5. Within 20 seconds of pressing blue tooth button, press
any button on remote control (Figure 6).
! NOTE :: Last step must be performed in 20 seconds.
Failure to do so will require steps to be repeated.
6. If synchronization was successful LED’s will blink 5
times and beep 5 times then unit will go to Standby.
WARNING :: Disconnect power before attempting cleaning
or maintenance to reduce risk of re, electric shock or injury.
Filling the water tank
When water tank is empty, ame effect shuts OFF and will
be 2 audible beeps, follow these steps.
CAUTION :: Allow at least ve minutes for components
to cool before disassembling unit to rell.
1. Gently remove top tray and place it carefully aside.
2. Turn On/Off switch to OFF position (0) (Figure 5A)
3. Remove rell container, lift upwards.
4. Refill container with tap water.
! NOTE :: Normal tap water can be used in AQUAFIRE. In
event your tap water is hard, use distilled water or soften
with 1⁄8 tsp of salt added to water reservoir. (Use addi-
tional salt only if unit is not producing mist as expected.)
5. Screw cap back on, do not overtighten.
6. Return relled container to sump, with tank cap facing
down and at side of tank facing outward.
7. Turn On/Off switch to OFF position (I). (Figure 5A)
8. Gently place top tray back into position.
! NOTE: If units are not used for 2 weeks or longer, empty,
drain water, and dry all components.
Cleaning
Clean top cover assembly, sump and transducer with soap
and water on a monthly basis.
Figure 5
most amazing fireplace ever
AQUAFIRE
Transducer Replacement
After prolonged usage, ability for unit to produce mist may
diminish. When this occurs replacement of transducer is
needed. AQ1000 includes 2 additional transducers, AQ500
includes 1 additional transducer. They can be found inside
cabinet in white cardboard box(es) and are easily installed.
! NOTE: There is a small clip that holds the transducer in
place; release before removed.
CAUTION :: Do not put plastic components in dishwasher.
Air Filter Cleaning
Remove air lters and gently rinse with water to clean.
Dry lters on a towel before reinstalling.
! NOTE: Replace lter, course black lter facing back of unit.
Surface Cleaning: Use a warm damp cloth to clean
surfaces of unit. Do not use abrasive cleaners.
! NOTE: When moving unit, empty components containing
water before relocating.
Servicing
Except for installation and cleaning more advanced ser-
vice may require support from our technical team guiding
a qualied local handyman or electrician. Call our ofce at
877.395.0888 between 9 am and 6 pm EST.
Warranty / 2 Years
Lumina Products Inc
www.luminaproducts.com
sales@luminaproducts.com
p: +1 877.395.0888
Figure 6
AQ1000 / 40“ Module / Dimensions
AQ500 / 20“ Module / Dimensions
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Lumina AQAAFIRE AQ1000 Setup And User Manual

Category
Fireplaces
Type
Setup And User Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI