Vents TT SILENT M 100 User manual

Category
Household fans
Type
User manual
20 31
www.vents-us.com
User’s
manual
Notice
d'utilisateur
Manual
de usuario
ES
EN
FR
IN-LINE MIXED TYPE
FANS OF VENTS TT SILENT M
SERIES
-
2
READ CAREFULLY AND SAVE THESE INSTRUCTIONS
EN
WARNING!
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND PERSONAL INJURY, READ AND UNDERSTAND
THE INSTRUCTIONS CAREFULLY
CAUTION!
1. Use the product only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
2. Before servicing or cleaning the unit, switch off the power at the main service panel and lock it to prevent the power
from accidentally being turned on. If the panel cannot be locked securely, fasten a prominent warning device, such as
tag, to it. If the unit is not hard-wired but rather plugged into a 120 volt outlet, simply unplug the cord from the receptacle.
3. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and
standards, include fire-rated construction codes and standards.
4. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
5. The fans must always be vented to the outdoors.
6. The fan may have sharp edges. Use caution to avoid being cut when installing and cleaning.
7. This fan must be grounded.
1. For general ventilation use only. Not for use in fire rated installations. Do not use the fan to exhaust hazardous or
explosive materials and vapors.
2. For interior use only. Mount with the lowest moving parts at least 8 feet (2.5 meters) above the floor or grade level.
3. To avoid the motor damage and noisy and/or unbalanced impeller, keep drywall spray, construction duct, etc.
off power unit.
4. Prior to installation operations make sure there is no visible damage to the impeller and housing.
Also make sure there are no foreign objects that may have accidentally gotten into the fan.
5. Please read specification label on product for further information and requirements.
6. To be installed by qualified personnel.
7. Connect the fan through breaker box.
8. Both the inlet and outlet must have no obstructions for the TT to work properly and be covered by the warranty.
9. When storing the fan keep it in a dry, weather-protected environment in the original packaging.
If the fan has been stored or set in a cold environment, wait 2 hours before connecting it to the power source.
3
The product described herein is a mixed flow fan for
exhaust ventilation.
Box includes:
1. Fan - 1;
2. Screws and countersinks 4;
3. User's manual;
The fans are compatible with 4” (100 mm), 5” (125 mm),
6” (150 mm), 8” (200 mm), 10” (250 mm), 12” (305 mm)
diameter ducts.
Understanding the Model Numbers:
The three digit number in all model names indicates the
following:
100 (100 mm) means it is used with 4” duct;
125 (125 mm) means it is used with 5” duct
150 (150 mm) means it is used with 6” duct;
200 (200 mm) means it is used with 8” duct;
250 (250 mm) means it is used with 10” duct;
305 (305 mm) means it is used with 12” duct.
- the basic fan model.
Equipped with an integrated speed switch and a power cord
with a plug for connection to a standard wall socket or with
a terminal box for direct connection to power.
It has the following operation modes (see fig. 29):
“0” turned off, the fan is not operating;
“I” the fan is operating at lowest speed;
“II” the fan is operating at highest speed.
- equipped with an
integrated speed controller with electronic thermostat,
a temperature sensor built into the air duct, and a power cord
with plug (fig. 30);
- equipped with
an integrated speed controller with electronic thermostat,
a remote temperature sensor on the end of a 13 feet
(4 meters) cable, and a power cord with plug (fig. 30)
- equipped with an integrated
speed controller and a power cord with plug (fig. 31).
The fans are suitable for vertical or horizontal mounting
(fig. 1).
VENTS TT SILENT-M_ _ _
VENTS TT SILENT-M_ _ _ U(U1, U2)
VENTS TT SILENT-M_ _ _ Un (U1n, U2n)
VENTS TT SILENT-M_ _ _ P
If mounting horizontally a duct at least 40 inches (1 meter) long
should be connected to the inlet side of the fan. If mounting
vertically a cap should be installed on the duct where it exits the
roof (fig. 2).
The outlet end should always be connected to a duct.
Mounting is shown in fig. 3-28.
The direction of the air must match the direction of the arrow
on the housing. Input: 120V AC 60Hz. Connection to the power
source is shown on figure 16, 20 and 26.
The fan is designed for continuous operation.
Protection rating from access to dangerous parts and water
penetration is IPX4.
The fans can be operated at ambient temperatures between
+37°F and +107°F (for the details, please, see the
manufacturer's catalog).
The fan surfaces need to be cleaned of dirt and dust regularly
by using a soft, wet cloth and mild detergent (Fig. 32-41).
Do not allow liquids to come in contact with the electric motor.
Wipe surfaces dry after cleaning.
fan adjusts air flow
depending on the temperature in the duct.
The "n" index models are equipped with a temperature sensor
on a 13 feet (4 meters) cable.
The terminal box cover incorporates two control dials and two
LED light indicators:
- speed dial
- thermostat dial
- yellow LED light thermostat indicator
- green LED light - power indicator
To increase the thermostat's set point rotate the dial clockwise.
To decrease the set point rotate the dial counter-clockwise.
To increase the fan speed rotate the speed dial clockwise.
To decrease the speed rotate the dial counter-clockwise.
Using the speed dial adjust the minimum required air flow so
it is below the thermostat set point.
The fan switches to low speed when the duct temperature drops
2° F below the thermostat set point.
This prevents possible frequent motor speed switches triggered
by crossing the temperature set point.
CONTROLLER OPERATION
VENTS TT SILENT-M_ _ _ U/U1/U2
TT SILENT U Operating mode-M
4
Following the instructions above will maintain the desired
temperature.
Using the speed dial adjust the minimum required air flow
so it is below the thermostat set point.
On reaching the pre-set temperature the motor switches
to high speed. The delay timer will start a 5-minute
countdown.
The motor will switch to low speed after the temperature
in the duct drops below the thermostat set point, but not
before the timer countdown is finished.
The minimum motor switching cycle in this mode is
5 minutes.
Set the desired fan speed by rotating the speed dial.
The fan will switch as soon as the temperature reaches the
thermostat set point.
The fan will stop as temperature drops 2° F below the
thermostat set point.
- equipped with a speed
controller that enables the fan switching on/off, smooth
motor speed (air capacity) control within the range of
minimum to maximum motor speed.
Fan construction is constantly being improved, that is why
some models can differ slightly from those described in t
his manual models.
TT SILENT-M U1 Operating mode
TT SILENT U2 Operating mode
VENTS TT SILENT-M_ _ _ P
-M
WARRANTY
Production meets standard operating requirements in the USA
and Canada.
VENTS US warrants to the original purchaser of the TT Silent-M
series fan that it will be free from defects in materials or
workmanship for a period of 60 months from the date of original
purchase.
THERE ARE NO OTHER WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE. During the stated warranty period,
VENTS US will, at its option, repair or replace, without charge,
any product or part which is found to be defective under normal
use and service. This warranty does not cover (a) normal
maintenance and normal service or (b) any products or parts
which have been subject to misuse, negligence, accident,
improper maintenance or repair (other than by VENTS US),
faulty installation or installation contrary to recommended
installation instructions. Labor to remove and replace products
is not covered. The duration of any implied warranty is limited
to the time period specified for the express warranty.
Some states do not allow limitations on how long an implied
warranty lasts, so the above limitation may not apply to you.
VENTS US OBLIGATION TO REPAIR OR REPLACE, AT
VENTS US OPTION, SHALL BE THE PURCHASER'S SOLE
AND EXCLUSIVE REMEDY UNDER THIS WARRANTY.
VENTS US SHALL NOT BE LIABLE FOR INCIDENTAL,
CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF
OR IN CONNECTION WITH PRODUCT USE OR
PERFORMANCE.
Some states do not allow the exclusion or limitations of incidental
or consequential damages, so the above limitation or exclusion
may not apply to you. This warranty gives you specific legal rights,
and you may also have other rights which vary from state to state.
This warranty supersedes all prior warranties.
If proof of sales date is absent, warranty period is calculated
from the production date.
The unit can be exchanged at the following address:
Bodor Vents, LLC
11013 Kenwood Road Cincinnati, Ohio 45242
Phone: (513)348-3853
Please follow guidelines in this manual for product problem-free
operation.
2
1
min 40 inches
min 40 inches
11
TT SILENT M 100/125/150/200-
5
7
4
5 6
QF
3
12
8
9
11
12
14
15
13
TT SILENT M- 250/305
QF
10
13
N
L
N
L
QF
X
~120V 60Hz
PE
TT SILENT M 100/125/150-
17
18 19
20
21 22
TO FAN
TO FAN
15
TT SILENT M 200/250/3 5-0
23
24 25
26
27 28
N
L
N
L
QF
X
~120V 60Hz
PE
16
31
Thermostat dial
Speed dial
Speed dial
min max
30
29
STANDARD
U/U1/U2
P
MAX
STOP
MIN
17
32
34
33
35
TT SILENT M 100/125/150/200-
18
100
1
150
0
25
200
250
35
Date of sale
Date de la vente
Fecha de venta
Manufactured on (date):
Vendu
(nom d'entreprise de commerce, cachet du magasin)
Fabriqué le (date)
Approval mark
Fecha de producion
Signe d'approbation
Marca de producción
Vendido
(Nombre de comercial, timbro o sello)de empresa
Sold
(n )ame of trading enterprise, stamp of store
ACCEPTANCE CERTIFICATE
CERTIFICAT D'ACCEPTATION
CERTIFICADO DE CALIDAD
The fan has been duly certified as serviceable.
.Le ventilateur a été certifié comme utilisable
Este ventilador está certificado para el uso normal.
TT S -ilent M
U
U1
U2
P
n
www.vents-us.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Vents TT SILENT M 100 User manual

Category
Household fans
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI