Multiple light beam safety device
Described product
deTem4 C
ore Ex II 3GD
Manufacturer
SICK AG
Erwin-Sick-Str. 1
79183 Waldkirch
Germany
Legal information
This w
ork is protected by copyright. Any rights derived from the copyright shall be
reserved for SICK AG. Reproduction of this document or parts of this document is only
permissible within the limits of the legal determination of Copyright Law. Any modifica‐
tion, abridgment or translation of this document is prohibited without the express writ‐
ten permission of SICK AG.
The trademarks stated in this document are the property of their respective owner.
© SICK AG. All rights reserved.
Original document
T
his doc
ument is an original document of SICK AG.
2
O P E R A T I N G I N S T R U C T I O N S | deTem4 Core Ex II 3GD 8021811/12FF/2019-01-21 | SICK
Subject to change without notice
Contents
1 About this document........................................................................ 6
1.1 Function of this document....................................................................... 6
1.2 Scope......................................................................................................... 6
1.3 Target groups and structure of these operating instructions................ 6
1.4 Additional information.............................................................................. 7
1.5 Symbols and document conventions...................................................... 7
2 Safety information............................................................................ 9
2.1 General safety notes................................................................................ 9
2.2 Intended use............................................................................................. 10
2.3 Requirements for the qualification of personnel.................................... 10
3 Product description........................................................................... 12
3.1 Structure and function............................................................................. 12
3.2 Product characteristics............................................................................ 13
3.2.1 Status indicators...................................................................... 13
3.3 Example applications............................................................................... 15
4 Project planning................................................................................ 16
4.1 Manufacturer of the machine.................................................................. 16
4.2 Operating entity of the machine.............................................................. 16
4.3 Design........................................................................................................ 16
4.3.1 Minimum distance from the hazardous point....................... 17
4.3.2 Minimum distance from reflective surfaces.......................... 18
4.3.3 Protection against interference from systems in close prox‐
imity t
o each other................................................................... 19
4.4 Integrating into the electrical control....................................................... 20
4.4.1 Restart interlock...................................................................... 22
4.4.2 External device monitoring (EDM).......................................... 22
4.5 Testing plan............................................................................................... 23
4.5.1 Test rod check.......................................................................... 24
4.5.2 Visual check of the machine and the protective device........ 24
5 Mounting............................................................................................. 26
5.1 Safety......................................................................................................... 26
5.2 Unpacking.................................................................................................. 26
5.3 Mounting................................................................................................... 27
5.3.1 Mounting the QuickFix bracket............................................... 28
5.3.2 Mounting the FlexFix bracket.................................................. 30
5.4 Affixing labels............................................................................................ 34
6 Electrical installation........................................................................ 35
6.1 Safety......................................................................................................... 35
6.2 System connection (M12, 5-pin)............................................................. 36
CONTENTS
8021811/12FF/2019-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem4 Core Ex II 3GD
3
Subject to change without notice
7 Commissioning.................................................................................. 38
7.1 Safety......................................................................................................... 38
7.2 Overview.................................................................................................... 38
7.3 Switching on.............................................................................................. 39
7.4 Alignment of the sender and receiver..................................................... 39
7.4.1 Aligning the sender and receiver............................................ 39
7.4.2 Aligning the sender, receiver, and deflector mirror................ 40
7.4.3 Alignment with the QuickFix bracket...................................... 41
7.4.4 Alignment with the FlexFix bracket or with the upgrade
br
ac
ket...................................................................................... 42
7.4.5 Indication of the alignment quality......................................... 43
7.5 Check during commissioning and modifications.................................... 44
8 Operation............................................................................................ 45
8.1 Safety......................................................................................................... 45
8.2 Regular thorough check........................................................................... 45
9 Maintenance...................................................................................... 46
9.1 Safety......................................................................................................... 46
9.2 Regular cleaning....................................................................................... 46
9.3 Regular thorough check........................................................................... 47
10 Troubleshooting................................................................................. 48
10.1 Safety......................................................................................................... 48
10.2 Diagnostic LEDs........................................................................................ 48
10.2.1 Fault indicators........................................................................ 48
11 Decommissioning............................................................................. 51
11.1 Protection of the environment................................................................. 51
11.2 Disposal..................................................................................................... 51
12 Technical data.................................................................................... 52
12.1 Data sheet................................................................................................. 52
12.2 Table of weights........................................................................................ 55
12.3 Dimensional drawings.............................................................................. 55
13 Ordering information........................................................................ 56
13.1 Scope of delivery....................................................................................... 56
13.2 Ordering information deTem4 Core Ex II 3GD......................................... 56
14 Accessories........................................................................................ 57
14.1 Brackets.................................................................................................... 57
14.2 Mounting accessories.............................................................................. 58
14.3 Connectivity............................................................................................... 58
14.4 Alignment aid............................................................................................ 59
14.5 Deflector mirrors....................................................................................... 60
14.5.1 Function and use..................................................................... 60
CONTENTS
4
O P E R A T I N G I N S T R U C T I O N S | deTem4 Core Ex II 3GD 8021811/12FF/2019-01-21 | SICK
Subject to change without notice
14.5.2 Change in scanning range using deflector mirrors................ 60
14.5.3 Deflector mirror – ordering information................................. 60
14.5.4 Deflector mirror PNS75 - ordering information...................... 60
14.5.5 Deflector mirror PNS125 - ordering information................... 61
14.6 Mirror columns.......................................................................................... 61
14.7 Device columns......................................................................................... 61
14.8 Accessories for mirror columns and device columns............................. 61
14.9 Cleaning agent.......................................................................................... 61
14.10 Test rods.................................................................................................... 62
15 Annex.................................................................................................. 63
15.1 Compliance with EU directives................................................................. 63
15.2 Note on specified standards.................................................................... 64
15.3 Checklist for initial commissioning and commissioning........................ 65
16 List of figures..................................................................................... 66
17 List of tables....................................................................................... 67
CONTENTS
8021811/12FF/2019-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem4 Core Ex II 3GD
5
Subject to change without notice
1 About this document
1.1 Function of this document
These operating instructions contain the information needed during the life cycle of the
multiple li
ght beam safety device.
Operating instructions of the multiple light beam safety device must be made available
to all people who work with the device.
Please read these operating instructions carefully and make sure that you understand
the content fully before working with the multiple light beam safety device.
1.2 Scope
These operating instructions only apply to the deTem4 Core Ex II 3GD multiple light
be
am s
afety device with the following type label entry in the Operating Instructions
field:
8021809
This document is included with the following SICK part numbers (this document in all
available language versions):
8021809
1.3 Target groups and structure of these operating instructions
These operating instructions are intended for the following target groups: project devel‐
oper
s (
planners, developers, designers), installers, electricians, safety experts (such as
CE authorized representatives, compliance officers, people who test and approve the
application), operators, and maintenance personnel.
The structure of these operating instructions is based on the life cycle phases of the
multiple light beam safety device: project planning, mounting, electrical installation,
commissioning, operation, and maintenance.
In many applications, therefore, the target groups consist of the manufacturer and the
operating entity of the machine in which the multiple light beam safety device is inte‐
grated:
Area of responsibility Target group Special chapters of these operating instruc‐
tions
1
Manuf
acturer Project developers
(planners, developers,
designers)
Project planning, page 16
Technical data, page 52
Accessories, page 57
Installers Mounting, pa
g
e 26
Electricians Electrical installation, page 35
Safety experts Project planning, pag
e 16
Commissioning, page 38
Technical data, page 52
Checklist for initial commissioning and com‐
missioning, page 65
Operating entity Operators Operation, pa
ge 45
Troubleshooting, page 48
Maintenance person‐
nel
Maint
enance, page 46
Troubleshooting, page 48
Ordering information, page 56
1
Chapters not listed here are intended for all target groups. All target groups must understand the safety
not
es in all of the operating instructions!
1 ABOUT THIS DOCUMENT
6
O P E R A T I N G I N S T R U C T I O N S | deTem4 Core Ex II 3GD 8021811/12FF/2019-01-21 | SICK
Subject to change without notice
In other applications, the operating organization is also the manufacturer of the equip‐
ment wit
h the corresponding allocation of the target groups.
1.4 Additional information
www.sick.com
The f
ollowing information is available on the Internet:
This document in other languages
Data sheets and application examples
CAD data and dimensional drawings
Certificates (e.g. EU declaration of conformity)
Guide for Safe Machinery Six steps to a safe machine
1.5 Symbols and document conventions
The following symbols and conventions are used in this document:
Safety notes and other notes
DANGER
Indica
tes a situation presenting imminent danger, which will lead to death or serious
injuries if not prevented.
WARNING
Indicates a situation presenting possible danger, which may lead to death or serious
injuries if not prevented.
CAUTION
Indica
tes a situation presenting possible danger, which may lead to moderate or minor
injuries if not prevented.
NOTICE
Indica
tes a situation presenting possible danger, which may lead to property damage if
not prevented.
NOTE
Indica
tes useful tips and recommendations.
Instructions to action
b
The ar
row denotes instructions to action.
1. The sequence of instructions for action is numbered.
2. Follow the order in which the numbered instructions are given.
The check mark denotes the result of an instruction.
LED symbols
These symbols indicate the status of an LED:
o
The LED is off.
Ö
The LED is flashing.
O
The LED is illuminated continuously.
ABOUT THIS DOCUMENT 1
8021811/12FF/2019-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem4 Core Ex II 3GD
7
Subject to change without notice
Sender and receiver
The
se symbols indicate the sender and receiver of the device:
s
The symbol indicates the sender.
r
The symbol indicates the receiver.
1 A
BOUT THIS DOCUMENT
8
O P E R A T I N G I N S T R U C T I O N S | deTem4 Core Ex II 3GD 8021811/12FF/2019-01-21 | SICK
Subject to change without notice
2 Safety information
2.1 General safety notes
DANGER
Ha
zard due to lack of effectiveness of the protective device
In the case of non-compliance, it is possible that the dangerous state of the machine
may not be stopped or not stopped in a timely manner.
b
Please read this document carefully and make sure that you understand the con‐
tent fully before working with the device.
b
Follow all safety notes in this document.
WARNING
Risk of ineffectiveness of the protective device
Please observe the following information to ensure safe and correct use of the device.
b
Special national and international regulations and guidelines apply for the mount‐
ing, use, commissioning, and regular technical inspection of electrical devices in
explosion-hazardous areas, in particular ATEX Directive 2014/34/EU and the
IECEx scheme. Manufacturers of and entities operating machines using the multi‐
ple light beam safety device are responsible for ensuring that all applicable safety
regulations and guidelines are complied with.
b
These operating instructions must be made available to the operator of the
machine on which the device is used. Qualified safety personnel must instruct the
operator on how to use the device. The operator must also be directed to read and
follow the operating instructions.
DANGER
Risk of i
gnition
Failure to observe this instruction can result in a risk of ignition from potential sparking.
b
Ensure that only accessories that are approved for explosion-hazardous areas are
used.
NOTICE
UV r
adiation can reduce the service life and resistance of the front screen. When used
in an explosion proof area, the front screen may not be exposed to any UV radiation
(e.g., sunlight).
b
Select a mounting position in which the front screen is not exposed to UV radia‐
tion.
NOTICE
Mec
hanic
al loads
The device passes the impact test required by the applicable standards.
Plastic device components must not be subjected to mechanical loads greater than
4 joules.
Transparent parts (front screen) must not be subjected to mechanical loads greater
than 2 joules.
SAFETY INFORMATION 2
8021811/12FF/2019-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem4 Core Ex II 3GD
9
Subject to change without notice
2.2 Intended use
Overview
T
he deT
em4 Core Ex II 3GD multiple light beam safety device is an electro-sensitive pro‐
tective device (ESPE) and is suitable for the following applications:
Single-sided access protection
Multi-sided access protection
The deTem4 Core Ex II 3GD multiple light beam safety device must only be used within
the limits of the prescribed and specified technical data and operating conditions at all
times.
Any instance of improper use, incorrect modification, or manipulation of the deTem4
Core Ex II 3GD multiple light beam safety device shall void any warranty provided by
SICK AG; furthermore, SICK AG shall not accept any responsibility or liability for any
resulting damage and consequential damage.
Important information
DANGER
Ha
zard due to lack of effectiveness of the protective device
Persons and parts of the body to be protected may not be recognized in case of non-
observance.
The multiple light beam safety device works as an indirect protective measure and can‐
not provide protection from pieces thrown from application nor from emitted radiation.
Transparent objects are not detected.
b
Only use the multiple light beam safety device as an indirect protective measure.
Improper use
Among o
thers, the deTem4 Core Ex II 3GD multiple light beam safety device is not suit‐
able for the following applications:
Outdoors
Underwater
At altitudes over 3,000 m above sea level
In environments with increased levels of ionizing radiation
2.3 Requirements for the qualification of personnel
The multiple light beam safety device must be configured, installed, connected, com‐
missioned
, and serviced only by qualified safety personnel.
Project planning
For project planning, a person is considered competent when he/she has expertise and
experience in the selection and use of protective devices on machines and is familiar
with the relevant technical rules and national work safety regulations.
Mechanical mounting, electrical installation, and commissioning
For the task, a person is considered qualified when he/she has the expertise and expe‐
rience in the relevant field and is sufficiently familiar with the application of the protec‐
tive device on the machine to be able to assess whether it is in an operationally safe
state.
2 SAFETY INFORMATION
10
O P E R A T I N G I N S T R U C T I O N S | deTem4 Core Ex II 3GD 8021811/12FF/2019-01-21 | SICK
Subject to change without notice
Operation and maintenance
For oper
ation and maintenance, a person is considered competent when he/she has
the expertise and experience in the relevant field and is sufficiently familiar with the
application of the protective device on the machine and has been instructed by the
machine operator in its operation.
SAFETY INFORMATION 2
8021811/12FF/2019-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem4 Core Ex II 3GD
11
Subject to change without notice
3 Product description
3.1 Structure and function
The deTem4 Core Ex II 3GD multiple light beam safety device is an electro-sensitive pro‐
tec
tive device (ESPE) consisting of a sender and receiver.
Parallel infrared light beams between the sender and receiver protect the hazardous
area. When one or more light beams are completely interrupted, the multiple light beam
safety device reports the interruption in the light path to the secure output signal
switching devices (OSSDs) by a signal change. The machine or its control must safely
analyze the signals (for example using a safe control or safety relays) and stop the dan‐
gerous state.
Sender and receiver automatically synchronize themselves optically. An electrical con‐
nection between both components is not required.
Figure 1: Sender and receiver
Beam separation and number of beams
The be
am separation is the distance between two adjacent light beams, measured
from the center of one beam to the center of the next.
The beam separation and number of beams depend on the device variant.
Scanning range
The sc
anning range is the maximum dimension of the light path between sender and
receiver. It depends on the device variant.
3 PRODUCT DESCRIPTION
12
O P E R A T I N G I N S T R U C T I O N S | deTem4 Core Ex II 3GD 8021811/12FF/2019-01-21 | SICK
Subject to change without notice
Information regarding beam separation and the dimension of the light path: see "Tec
h‐
nical data", page 52.
The scanning range is reduced by using deflector mirrors.
3.2 Product characteristics
3.2.1 Status indicators
The sender and receiver LEDs indicate the operational status of the safety light curtain.
Sender indicators
ERR
PWR
2
1
Figure 2: Sender indicators
Tw
o light emitting diodes on the sender indicate the operational status:
Position LED color Display Labeling
1
Yellow Status indicator PWR
2
Red Fault indicator ERR
Complete overview of the light emitting diode statuses and their meanings: see "Diag‐
nostic LEDs", page 48.
PRODUCT DESCRIPTION 3
8021811/12FF/2019-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem4 Core Ex II 3GD
13
Subject to change without notice
Receiver indicators
ERR
OSSD
1 2 3 4
2
1
3
Figure 3: Receiver indicators
Six li
ght emitting diodes on the receiver indicate the operational status:
Position LED color Display Labeling
1
Red/green OSSD status OSSD
2
Red Fault indicator ERR
3
Blue Alignment quality 1, 2, 3, 4
The blue alignment quality light emitting diodes in combination with the red flashing
ERR LED also deno
te faults.
Complete overview of the light emitting diode statuses and their meanings: see "Diag‐
nostic LEDs", page 48.
3 PRODUCT DESCRIPTION
14
O P E R A T I N G I N S T R U C T I O N S | deTem4 Core Ex II 3GD 8021811/12FF/2019-01-21 | SICK
Subject to change without notice
3.3 Example applications
Figure 4: Single-sided access protection
Figure 5: Multi-sided access protection
PRODUCT DESCRIPTION 3
8021811/12FF/2019-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem4 Core Ex II 3GD
15
Subject to change without notice
4 Project planning
4.1 Manufacturer of the machine
DANGER
Ha
zard due to lack of effectiveness of the protective device
Persons and parts of the body to be protected may not be recognized in case of non-
observance.
b
Use of the multiple light beam safety device requires a risk assessment. Check
whether additional protective measures are required.
b
Comply with the applicable national regulations derived from the application (e.g.,
work safety regulations, safety rules, or other relevant safety guidelines).
b
Do not combine the components of the multiple light beam safety device with
components from other multiple light beam safety devices.
b
Apart from the procedures described in this document, the components of the
multiple light beam safety device must not be opened.
b
The components of the multiple light beam safety device must not be tampered
with or changed.
b
Improper repair of the protective device can lead to a loss of the protective func‐
tion. Do not carry out any repairs on the device components.
4.2 Operating entity of the machine
DANGER
Ha
zard due to lack of effectiveness of the protective device
Persons and parts of the body to be protected may not be recognized in case of non-
observance.
b
Changes to the electrical integration of the multiple light beam safety device in the
machine control and changes to the mechanical mounting of the multiple light
beam safety device necessitate a new risk assessment. The results of this risk
assessment may require the operating entity of the machine to meet a manufac‐
turer’s obligations.
b
Apart from the procedures described in this document, the components of the
multiple light beam safety device must not be opened.
b
The components of the multiple light beam safety device must not be tampered
with or changed.
b
Improper repair of the protective device can lead to a loss of the protective func‐
tion. Do not carry out any repairs on the device components.
4.3 Design
This chapter contains important information about the design.
Information on the individual steps for mounting the device: see "Mounting", page 26.
4 PROJECT PLANNING
16
O P E R A T I N G I N S T R U C T I O N S | deTem4 Core Ex II 3GD 8021811/12FF/2019-01-21 | SICK
Subject to change without notice
DANGER
Ha
zard due to lack of effectiveness of the protective device
Persons and parts of the body to be protected may not be recognized in case of non-
observance.
b
Make sure that the following design requirements are met so that the multiple
light beam safety device can fulfill its protective function.
°
Sender and receiver must be arranged such that persons or parts of the body
are reliably detected when they enter the hazardous area.
°
Ensure that nobody can pass under the lowest light beam, pass over the
highest light beam, get between two light beams, or pass by the side of the
protective device.
°
If people can stay between the protective device and the hazardous point
without being detected, check if additional protective measures (e.g., restart
interlock) are required.
DANGER
Ha
zard due to lack of effectiveness of the protective device
Certain types of light radiation can influence the protective device, e.g., light radiation
from fluorescent lamps with electronic ballast installed in the path of the beam, or
beams from laser pointers directed at the receiver.
b
If this type of light radiation is present in the environment of the protective device,
take additional measures to ensure that the protective device does not become
dangerous.
4.3.1 Minimum distance from the hazardous point
A minimum distance must be maintained between the multiple light beam safety
dev
ice and the hazardous point. This distance is required to prevent a person or part of
the body from reaching the hazardous area before the dangerous state of the machine
state has completed.
Calculating the minimum distance according to ISO 13855
The calculation of the minimum distance is based on international or national stan‐
dards and statutory requirements applicable at the place of installation of the machine.
If the minimum distance is calculated according to ISO 13855, then it depends on the
following points:
Machine stopping time (time interval between triggering the sensor function and
the end of the machine’s dangerous state)
Response time of the protective device, see "Technical data", page 52
Approach speed of personnel
Type of approach: orthogonal (at right angles)
Parameters specified based on the application
For the USA (scope of OSHA and ANSI), different regulations may apply, e.g.:
a) Laws: Code of Federal Regulations, Title 29 (CFR29) Part 1910.217
b) Standards: ANSI B11.19
Complementary information
A
ddit
ional information is available in the ISO 13855 standard and in the Guidelines
Safe Machinery.
SICK offers a stopping/run-down time measurement service in many countries.
PROJECT PLANNING 4
8021811/12FF/2019-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem4 Core Ex II 3GD
17
Subject to change without notice
4.3.2 Minimum distance from reflective surfaces
Overview
T
he li
ght beams from the sender may be deflected by reflective surfaces and dispersive
media. This can prevent an object from being detected.
Therefore, all reflective surfaces and objects (e.g., material bins, machine table, etc.)
must maintain a minimum distance (a) from the light beams. This minimum distance
(a) must be maintained on all sides of the light beams. This applies in horizontal, verti‐
cal, and diagonal directions as well as at the ends of the multiple light beam safety
device. The same area must be free of dispersive media (e.g., dust, fog, or smoke).
The minimum distance (a) depends on the distance (D) between sender and receiver.
rs
D
a
Figure 6: Minimum distance from reflective surfaces
Important information
DANGER
H
a
zard due to lack of effectiveness of the protective device
Reflective surfaces and dispersive media can prevent persons or parts of the body to
be protected from being properly reflected and therefore, they remain undetected.
b
Make sure that all reflective surfaces and objects maintain a minimum distance
from the light beams.
b
Make sure that no dispersive media (e.g., dust, fog, or smoke) are within the calcu‐
lated minimum distance from the light beams.
Determining minimum distance to reflective surfaces
The minimum dis
tance can be determined as follows:
1. Determine the distance between the sender and receiver D in meters (m).
2. Locate the minimum distance a in millimeters (mm) on the graph, or calculate it
using the appropriate formulatable 1:
4 PROJECT PLANNING
18
O P E R A T I N G I N S T R U C T I O N S | deTem4 Core Ex II 3GD 8021811/12FF/2019-01-21 | SICK
Subject to change without notice
10 20 30 40 50 60 70 D/
m
500
1000
2000
1500
2500
3000
3500
a/mm
131
3
Figure 7: Graph of minimum distance from reflective surfaces
Table 1: F
ormula for calculating the minimum distance from reflective surfaces
Distance (D) between sender and
rec
eiver in m
Calculation of the minimum distance (a) from reflective
surfaces in mm
D ≤ 3 m a = 131 mm
D > 3 m a = tan (2.5°) × 1,000 mm/m × D = 43.66 × 1 mm/m ×
D
4.3.3 Protection against interference from systems in close proximity to each other
Overview
s
rs
r
!
"
Figure 8: Preventing mutual interference from system
1
and system
2
The infrared light beams of the sender of system 1 can interfere with the receiver of
system 2. This can disrupt the protective function of system 2. This would mean that
the operator is at risk.
Avoid such installation situations or take appropriate action, e.g., install optically
opaque partitions or reverse the direction of transmission of a system.
Important information
DANGER
Ha
zard due to lack of effectiveness of the protective device
Systems of multiple light beam safety devices in close proximity to each other can
mutually interfere with each other.
b
Use suitable measures to prevent interference between systems in close proximity
to each other.
PROJECT PLANNING 4
8021811/12FF/2019-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem4 Core Ex II 3GD
19
Subject to change without notice
4.4 Integrating into the electrical control
This chapter contains important information about integration in the electrical control.
Inf
or
mation about the individual steps for electrical installation of the device: see "Elec‐
trical installation", page 35.
Requirements for use
The output signals of the protective device must be analyzed by downstream controllers
in such a way that the dangerous state of the machine is ended safely. Depending on
the safety concept, the signal is analyzed by, e.g., safety relays or a safety controller.
DANGER
Ha
zard due to lack of effectiveness of the protective device
In the case of non-compliance, it is possible that the dangerous state of the machine
may not be stopped or not stopped in a timely manner.
b
Make sure that the following control and electrical requirements are met so that
the multiple light beam safety device can fulfill its protective function.
It must be pos
sible to electrically influence the control of the machine.
The electrical control of the machine must meet the requirements of IEC 60204-1.
Depending on the regulations which apply at the place of installation, a restart
interlock may be required. Because the multiple light beam safety device does not
have this function, it must be implemented in the external control if required.
When using a safety controller, different signal levels of both OSSDs must be
detected depending on the regulations which apply at the place of installation or
the required reliability of the safety function. The maximum discrepancy time toler‐
ated by the control must be selected according to the application.
The OSSD1 and OSSD2 output signals must not be connected to each other.
In the machine controller, the signals of both OSSDs must be processed sepa‐
rately.
Figure 9: Dual-channel and isolated connection of OSSD1 and OSSD2
T
he mac
hine must switch to the safe state at any time if at least one of the two
OSSDs switches to the OFF state.
4 PROJECT PLANNING
20
O P E R A T I N G I N S T R U C T I O N S | deTem4 Core Ex II 3GD 8021811/12FF/2019-01-21 | SICK
Subject to change without notice
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68

SICK deTem4 Core Ex II 3GD Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI