  • Hello! I am an AI chatbot trained to assist you with the Marantec Protect-Opto 502 Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
EN
Signal transmission system Protect Opto / Rev.C 0.2 – 1
Operating Instructions
Signal transmission system Protect Opto 500|501|502
2 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 3
1. Contents
1. Contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2. Information in this document . . . . . . . . . . . . .3
3. General safety instructions . . . . . . . . . . . . . . .3
4. Overview of product . . . . . . . . . . . . . . . . . . . .4
4.1 General ...........................4
4.2 “1-channel“ system ..................4
4.3 “2-channel“ system ..................5
5. Initial operation . . . . . . . . . . . . . . . . . . . . . . . .6
5.1 General ...........................6
5.2 Externalinuences ...................6
5.3 Inputoftheclosingedgesystematthegate
control . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
6. 1-channel system . . . . . . . . . . . . . . . . . . . . . . .7
6.1 1-channeltransmitter[Tx1.0]...........7
6.2 Allocationofconnections ..............7
6.3 Adaptingthetransmissionfrequency......7
6.4 Plug-inreceiver[SRTMODBANDMFZ] ....8
6.5 Programming .......................8
6.6 Resetting the receiver .................8
6.7 Adaptingthetransmissionfrequency......8
6.8 DisplayLED2and3 ..................8
6.9 1-channelexternalreceiver[Rx1.0] ......9
6.10 Allocationofconnections ..............9
6.11 DIPswitchsetting...................10
6.12 Programming ......................10
6.13 Resetting the receiver ...............10
6.14 DisplayLED2 ......................10
7. 2-channel system . . . . . . . . . . . . . . . . . . . . . .11
7.1 2-channeltransmitter[Tx2.F] ..........11
7.2 AllocationofCHANNEL1connections....11
7.3 AllocationofCHANNEL2connections....11
7.4 Adaptingthetransmissionfrequency.....12
7.5 Plug-inreceiver[SRTMODBANDMFZ] ..13
7.6 Programming ......................13
7.7 Resetting the receiver ................13
7.8 Adaptingthetransmissionfrequency.....13
7.9 DisplayLED2and3 .................13
7.10 2-channelexternalreceiver[Rx2.F]......14
7.11 Allocationofchannel1connections .....14
7.12 Allocationofchannel2connections .....16
7.13 DIPswitchsetting...................18
7.14 Optosensor activation time ............18
7.15 Programming ......................18
7.16 Resetting the receiver ...............19
7.17 DisplayLED2 ......................19
8. Technical data . . . . . . . . . . . . . . . . . . . . . . . .19
8.1 System ...........................19
8.2 1-channel transmitter . . . . . . . . . . . . . . . . 19
8.3 2-channel transmitter . . . . . . . . . . . . . . . . 19
8.4 1 or 2-channel external receiver ........19
8.5 2-channelplug-inreceiver.............19
9. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . .20
10. Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
11. EC Declarations of conformity . . . . . . . . . . . .21
Signal transmission system Protect Opto / Rev.C 0.2 – 3
EN
2 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 3
Original operating instructions
Copyright.
Nopartoftheseinstructionsmaybereproducedwithout
ourpriorapproval.
Subjecttoalterationsintheinterestoftechnicalprogress.
Alldimensionsgiveninmm.
Thediagramsinthismanualarenottoscale.
Key to symbols
DANGER!
Indicatesahazardwithahighlevelofriskwhich,ifnot
avoided,willresultindeathorseriousinjury.
WARNING!
Indicatesahazardwithamediumlevelofriskwhich,ifnot
avoided,couldresultindeathorseriousinjury.
CAUTION!
Indicatesahazardwithalowlevelofriskwhich,ifnot
avoided,couldresultinminorormoderateinjury.
ATTENTION!
Indicatesanimminentdangerofdamageordestruction.
CHECK
Indicatesachecktobeperformed.
REFERENCE
Referencetoseparatedocumentswhichmustbecomplied
with.
Actionrequest
List,itemisation
Referencetoothersectionsofthisdocument
2. Information in this document 3. General safety instructions
DANGER!
Failure to comply with the documentation could
result in life-threatening danger!
Besuretofollowallthesafetyinstructionsinthis
document.
Warranty
Thefunctionandsafetyoftheequipmentisonlyguaranteed
ifthewarningandsafetyinstructionsincludedinthese
operatinginstructionsareadheredto.
MarantecGmbH+Co.KGisnotliableforpersonalinjuryor
damagetopropertyiftheseoccurasaresultofthewarnings
andsafetyadvicebeingdisregarded.
Marantecdoesnotacceptanyliabilityorwarrantyfordamage
duetotheuseofnon-approvedsparepartsandaccessories.
Intended use
Thesystemisforwirelesssignaltransmissionofsignalsto
doorsystemsandiscompatiblewithMaranteccontrols
CS255andCS310.Dependingonthesystem,signalscanbe
transmittedfromdifferentclosingedgesafetydevicesora
safetycircuit.
Theuseofaspiralcabletotransmitsignalsisnotnecessary.
Target group
Onlyqualiedandtrainedelectriciansmayconnect,
programmeandservicethesignaltransmissionsystem.
Qualiedandtrainedelectriciansmustmeetthefollowing
requirements:
knowledgeofthegeneralandspecicsafetyandaccident
preventionregulations,
knowledgeoftherelevantelectricalregulations,
trainingintheuseandcareofappropriatesafety
equipment,
capableofrecognisingthedangersassociatedwith
electricity.
Instructions regarding installation and connection
Thecontrolmustbedisconnectedfromtheelectricity
supplybeforecarryingoutanyelectricalwork.Itmustbe
ensuredthattheelectricitysupplyremainsdisconnectedfor
thedurationofthework.
Localprotectiveregulationsmustbecompliedwith.
4 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 5
4 – Signal transmission system Protect Opto / Rev.C 0.2
Information concerning operation
Unauthorisedpersons(particularlychildren)shouldnotbe
allowedtoplaywithpermanentlyinstalledadjustingor
controldevices.
Keepremotecontrolsbeyondthereachofchildren.
Observethevalidstandardsandregulations!
4. Overview of product
4.1 General
Thisisabidirectionalradiotransmissionsystemfor
connectingsafetydevicesforautomaticdoordrives.
Theradiocontactisbetweenareceiverunitwhichis
connectedtothedrivecontrolandatransmitterunitwhichis
attachedtothedoor.
Either
anenergy-savingoptoelectronic(lowpower)closingedge
safetydevice,
an8.2kΩresistanceswitchingstrip,or
aswitchingcontact
canbeconnectedtothetransmitterunit.
Eachreceiverunitcanmanageupto7transmitterunits.The
systemhasarangeofabout10metres.Theresponsetime
ofthesystemwhenaswitchingstripisactivatedislessthan
100 ms.
Itispossibletousemorethanoneradiotransmissionsystem
inabuildingprojectwithoutresultingininterferencebetween
the systems.
Thetransmitterunitsarebattery-poweredandunderideal
conditionshaveabatterylifeofabout2yearsiftwobatteries
areused.Intheeventofahighnumberofswitchingcycles,
orbadtransmittingconditionsoradverseweatherconditions,
thebatterywillhaveaconsiderablyshorterlife.
Itisrecommendedthatthebatteriesarereplacedduringthe
annualservice.
4.2 “1-channel“ system
The“1-channel“systemconsistsof
anexternaltransmitter,thatcantransmiteither1closing
edgesafetydeviceonan8.2kΩbasisorasafetycircuit
withapotential-freeNCcontact.
anexternalreceiverthatcanbeconnectedwithacableto
MaranteccontrolsCS255andCS310
or
aplug-inreceiverwhichcanonlybeusedinconjunction
withMaranteccontrolCS310.
General safety instructions
4 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 5
EN
4.3 “2-channel“ system
The“2-channel“systemconsistsof
anexternaltransmitterthatcantransmitthefollowing
combinationsofsafetycomponents:
1xoptosensorclosingedgesafetydeviceand
1x8.2kΩclosingedgesafetydevice
1xoptosensorclosingedgesafetydeviceand
1xNC/NOsafetycircuit
2x8.2kΩclosingedgesafetydevice
1x8.2kΩclosingedgesafetydeviceand
1xNC/NOsafetycircuit
anexternalreceiverthatcanbeconnectedwithacableto
MaranteccontrolsCS255andCS310
or
aplug-inreceiverwhichcanonlybeusedinconjunction
withMaranteccontrolCS310.
4.3 / 1 4.3 / 2 4.3 / 3
1-channel transmitter
Tx 1.0
“6.1 1-channel
transmitter[Tx1.0]“
2-channel transmitter
Tx2.F
“7.1 2-channel
transmitter[Tx2.F]“
4.3 / 4 4.3 / 5
1-channel external receiver Rx 1.0
“6.91-channelexternalreceiver[Rx1.0]“
4.3 / 6
4.3 / 7
2-channelexternalreceiverRx2.F
“7.102-channelexternalreceiver[Rx2.F]“
4.3 / 8
2-channelplug-inreceiver–>onlyforcontrolCS310
“6.4Plug-inreceiver[SRTMODBANDMFZ]“
“7.5Plug-inreceiver[SRTMODBANDMFZ]“
6 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 7
5.1 General
Toguaranteethattheequipmentfunctionsproperly,itmust
beensuredthat:
Thedoorisinstalledandoperational.
Thedrivemotorisinstalledandreadyforoperation.
Thedoorcontrolisinstalledandreadyforoperation.
Thecommandandsafetydevicesareinstalledandreadyfor
operation.
REFERENCE
Therelevantmanufacturers’instructionsmustbeadheredto
wheninstallingthedoor,theMarantecdrivemotor,andthe
commandandsafetydevices.
5.2 External inuences
Requirements
Toensureproperoperationofthesystem,thefollowing
conditionsmustbemet:
Theremustnotbeanymetalsurfacesbetweenthe
transmitterandthereceiver.
Theremustnotbeastrongmagneticeldorotherwireless
systemsinthedirectvicinityofthesystem.
Theremustbeadistanceofatleast1metrebetweenthe
transmitterandthereceiver.
ATTENTION!
Malfunctions due to external inuences!
Thesignaltransmissionsystemgenerallyhasarangeofat
least 10 metres.
Localconditionshowevercouldcauseareductioninthe
rangeeventothepointoftotalfailureofthesystem
(Examples:high-voltagelines,magneticelds,radio
masts,otherradiosystems,wallsandceilingsofreinforced
concrete,steelconstructionsinindustrialhalls,frequency-
controlledmachineryetc.).
5. Initial operation
5.3 Input of the closing edge system at the
gate control
Inordertoavoidmalfunctions,theinputoftheclosingedge
systemontheMarantecgatecontrolsCS310andCS255
mustbeequippedwithan8.2kΩresistorandcongured
accordingly.
Otherwise,anerrormessageisdisplayedconstantlyatthis
pointduetothe“missing”closingedgeprotectivedevice.
Pulseorautomaticoperationarethennolongerpossible.
Gate control CS310 (X4)
ParameterSKS=MOD2
8k2
1
2
3
4
5
6
7
8
9
12
11
10
X4
5.3 / 1
Gate control CS255 (XP74)
ParameterSKS=MOD2
XP74
45
40
47
+
8k2
5.3 / 2
NOTICE:
Whenusinggatecontrolsfromothermanufacturers:
Requestthenecessarycongurationorpre-settingsfromthe
technicalservicedepartmentoftherespectivemanufacturer.
6 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 7
EN
6.2 Allocation of connections
Connection of a 8.2 kΩ closing edge safety device
6.2 / 1
Closingedgesafetydevice DIP 1
Connection of a safety device
6.2 / 2
NCsafetydevice
e.g.slackropeswitch
DIP 1
6.3 Adapting the transmission frequency
FactorysettingDIP2=OFF
DIP 2
6.3 / 1
DIP 2
6.3 / 2
869.85MHz 868.95MHz
CHECK
Thesettingonthetransmitterandreceivermustbe
identical.
6. 1-channel system
6.1 1-channel transmitter [Tx1.0]
A
B
C
D
E
F
6.1 / 1
Key:
A Programmingbutton
B DIPswitches
C LED1
D Battery2
E Battery1
F TerminalX1
8 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 9
6.4 Plug-in receiver [SRTMODBANDMFZ]
Circuit board CS310 / plug-in socket X20
6.4 / 1
A
B
C
D
E
Key:
A LED3(red/channel2)
B DIPswitches
C LED2(red/channel1)
D Programmingbutton
E LED1(green/status)
OnlyinconjunctionwithMarantecCS310controlfrom
softwareversion1.30upwards.
Theplug-inreceiverisa2-channelreceiver.Ifa1-channel
transmitterisprogrammed(taught-in),channel1isalways
theprogrammedchannelandcorrespondstoparameter
CESD3.
REFERENCE
Moreinformationisgivenintheoperatinginstructionsfor
the CS310 control.
6.5 Programming
Keeptheprogrammingbuttononthereceiverpressedfor
about1second.
Releasetheprogrammingbuttononthereceiver.
LED1(green)lightsupforabout8seconds.
Duringthese8seconds,brieypresstheprogramming
buttononthetransmitteronce.
Afterabout4seconds,LED1(green)willgooff.
Iftheclosingedgesafetydevice/stopcircuitisworking
correctly,LED2(red)willlightupcontinuouslyandsignal
thatchannel1hasbeenprogrammed.Thetransmitterisnow
programmed(taught-in).
CHECK
Theremustbeadistanceofatleast1metrebetweenthe
transmitterandthereceiver.
NOTICE:
Eachreceiverunitcanmanageupto7transmitterunits.If
7transmittershavebeenprogrammeddirectlyonareceiver,
thememoryisfullandawarningsignalwillsoundfor
10seconds.
6.6 Resetting the receiver
Keeptheprogrammingbuttononthereceiverpressedfor
about3seconds.LED1(green)ashesforabout1second.
Releasetheprogrammingbuttononthereceiver.
LED1(green)lightsupforabout8seconds.
The receiver memory is empty.
6.7 Adapting the transmission frequency
FactorysettingDIP1=OFF
“6.3Adaptingthe
transmissionfrequency“
869,85 MHz
868,95 MHz
DIP 1
6.8 Display LED 2 and 3
ON: SystemOK,safetyfunctionworking.
OFF: Closingedgesafetydevicetriggeredorsafetycircuit
interrupted.
1-channel system
8 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 9
EN
6.9 1-channel external receiver [Rx 1.0]
A
B
C
D
E
6.9 / 1
Key:
A DIPswitches
B LED1(status)
C LED2
(channel1)
D Programming
button
E TerminalX1
6.10 Allocation of connections
Connection of an 8.2 kΩ closing edge safety device
Active in CLOSE direction
A
B
C
6.10 / 1
A
B
C
Connection to power supply
Control CS255/XB50-6/5
CS310/X4-1/2
A
B
C
Connection to a CESD 8.2 kΩ input
Control CS255/XP74-2/3
CS310/X4-5/6
“CESD“parametersetting–MOD 2
A
B
C
Test signal
Connectiontorelayoutput
CS255CS255/XH19
CS310/X5
“RELAY“parametersetting–MOD 22
Transmission of a 8.2 kΩ closing edge safety device
Active in OPEN direction
A
B
C
6.10 / 2
A
B
C
Connection to power supply
Control CS255/XB50-6/5
CS310/X4-1/2
A
B
C
Connection to programmable input 2
Control CS255/XP74-2/5
CS310/X4-11/12
“INPUT2“parametersetting
– MOD 3 (stop and reverse)
– MOD 4 (stop and reversing movement)
A
B
C
Test signal
Connectiontorelayoutput
Control CS255/XH19
CS310/X5
“RELAY“parametersetting–MOD 41
Transmission of a safety device
A
B
C
6.10 / 3
A
B
C
Connection to power supply
Control CS255/XB50-6/5
CS310/X4-1/2
A
B
C
Connection to a safety circuit
Control CS255/XR51-1/2
CS310/X3-1/2
A
B
C
Test signal
Connectiontorelayoutput
CS255CS255/XH19
CS310/X5
“RELAY“parametersetting– MOD 37
10 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 11
6.11 DIP switch setting
6.11 / 1
Safety application
ON: ActiveaccordingtoDINEN13849-1*
OFF: Inactive,safetyfunctionnotworking
Radioconnectionisnotmonitored
DIP1mustbesettoONforstandard-compliant
operation.
6.11 / 2
Transmission frequency
ON: 869.85MHz
OFF: 868.95MHz*
Thesettingsforthetransmitterandthereceivermust
beidentical.
“6.4Plug-inreceiver[SRTMODBANDMFZ]“
6.11 / 3
Type of test output contact
ON: NC
OFF: NO*
Thesettingdependsonthetypeoftestoutputcontact
on the control.
6.11 / 4
Automatic frequency adaptation
ON: Active
OFF: Inactive*
Onlyactivateifthereissevereradiointerference
*Factorysettings
6.12 Programming
Keeptheprogrammingbuttononthereceiverpressedfor
about2secondsuntilanacousticsignalsounds.
Releasetheprogrammingbuttononthereceiver.
LED1lightsupforabout8seconds.
Duringthese8seconds,brieypresstheprogramming
buttononthetransmitteronce.
Anacousticsignalsounds.
Afterabout4seconds,2acousticsignalswillsoundone
aftertheother.LED1goesoff.
Iftheclosingedgesafetydevice/stopcircuitisworking
correctly,LED2willlightupcontinuouslyandsignalthatthe
transmitterhasbeenprogrammed.
1-channel system
CHECK
Theremustbeadistanceofatleast1metrebetweenthe
transmitterandthereceiver.
NOTICE:
Eachreceiverunitcanmanageupto7transmitterunits.If
7transmittershavebeenprogrammeddirectlyonareceiver,
thememoryisfullandawarningsignalwillsoundfor
10seconds.
6.13 Resetting the receiver
Keeptheprogrammingbuttononthereceiverpressedfor
about2secondsuntilanacousticsignalsounds.
Keeptheprogrammingbuttononthereceiverpressedfor
about3secondsuntilseveralshortacousticsignalssound
oneaftertheother.
LED1ison.
Releasetheprogrammingbuttononthereceiver.
Afterabout10seconds,2acousticsignalswillsoundone
aftertheother.LED1goesoff.
The receiver memory is empty.
6.14 Display LED 2
ON: SystemOK,safetyfunctionworking.
OFF: Closingedgesafetydevicetriggeredorsafetycircuit
interrupted.
CHECK
Ifthebatterychargeistoolow,4consecutivewarning
signalswillsoundeverytimethatthetransmittersends
information.Thetransmitterunitbatteriesmustthenbe
replacedimmediately.Itisrecommendedthatthebatteries
arereplacedatleastonceayearduringtheperiodicdoor
inspection.
10 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 11
EN
7. 2-channel system
7.1 2-channel transmitter [Tx2.F]
D
C
F
B
A
E
7.1 / 1
Key:
A LED
B Programming
button
C DIPswitches
D Battery1
E Battery2
F TerminalX1
7.2 Allocation of CHANNEL 1 connections
Connection of a safety device
7.2 / 1
NCsafetydevice
e.g.slackropeswitch
TheNCtypeofcontactispreprogrammedinthefactoryand
cannotbereprogrammedtoaNOcontact.
Connection of an 8.2 kΩ closing edge safety device
7.2 / 2
Closingedgesafetydevice
NOTICE:
Ifchannel1isnotused:
Fitawirejumperonterminals1-2.
SetDIP1toOFF.
Bothchannelsarecheckedduringthetestroutine.
Ifnothingisconnectedtoachannel,anerrormessageis
issuedandthefunctionisnolongeravailable.
7.3 Allocation of CHANNEL 2 connections
Channel2canbeusedtoconnectandprogramme
differentcomponents:
Optosensor(OSE)closingedgesafetydevice
Electricalcontactbaroftheclosingedgesafetydevice
SafetydevicewithNCcontact
Componentselectioniscarriedoutin2stages.
Step 1:
Insertbatteries1and2.
AnLED(red)statusreportisgiven.
Flashes2times:
OneOSEsystemiscurrentlyprogrammed
(factorysetting).
Flashes5times:
One8.2kΩsystemand/oraNCcontactiscurrently
programmed.
Tochangethesystem,keeptheprogrammingbutton on the
transmitterpressedforatleast2seconds.
Thesettingischanged.
AnewstatusreportisgivenbytheLEDaboutthecurrent
status.
Flashes2times:OSEsystem
Flashes5times:8.2kΩ/NCcontact
Thecomponentselectionischanged.
12 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 13
After inserting battery 1, only 10 seconds time is left
to change the component selection.
Step 2:
UseDIPswitch2tomakethefurtherselection.
IftheOSEsystemisprogrammed,DIPswitch2must
generallybesetto ON.
Ifa8.2kΩsystemand/oraNCcontactisprogrammed,
DIPswitch2mustbesettoON
ifa8.2kΩsystemisconnected.
DIPswitch2mustbesettoOFF
ifaNCcontactisconnected.
Connection of an OSE closing edge safety device
7.3 / 1
Closingedgesafetydevice
4 white
5 green
6 brown
Connection of an 8.2 kΩ closing edge safety device
7.3 / 2
Closingedgesafetydevice
Connection of a safety device
7.3 / 3
NCsafetydevice
e.g.slackropeswitch
NOTICE:
Ifchannel2isnotused:
Fitawirejumperonterminals4-5.
SetDIP2toOFF.
Bothchannelsarecheckedduringthetestroutine.
Ifnothingisconnectedtoachannel,anerrormessageis
issuedandthefunctionisnolongeravailable.
7.4 Adapting the transmission frequency
FactorysettingDIP3=OFF
DIP 3
7.4 / 1
DIP 3
7.4 / 2
869.85MHz 868.95MHz
CHECK
Thesettingonthetransmitterandreceivermustbe
identical.
2-channel system
12 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 13
EN
7.5 Plug-in receiver [SRTMODBANDMFZ]
Circuit board CS310 / Plug-in socket X20
7.5 / 1
A
B
C
D
E
Key:
A LED3(red/channel2)
B DIPswitches
C LED2(red/channel1)
D Programmingbutton
E LED1(green/status)
OnlyinconjunctionwithMarantecCS310controlfrom
softwareversion1.30upwards.
Channel2correspondstoparameterCESD3oftheCS310.
Channel2correspondstoparameterCESD4oftheCS310.
Moreinformationisgivenintheoperatinginstructionsfor
the CS310 control.
7.6 Programming
Keeptheprogrammingbuttononthereceiverpressedfor
about1second.
Releasetheprogrammingbuttononthereceiver.
LED1(green)lightsupforabout8seconds.
Duringthese8seconds,brieypresstheprogramming
buttononthetransmitteronce.
Afterabout4seconds,LED1(green)willgooff.
Iftheclosingedgesafetydevice/stopcircuitisworking
correctly,LED2(red)andLED3(red)willlightup
continuouslyandsignalisethatchannel1hasbeen
programmed.Thetransmitterisnowprogrammed(taught-in).
NOTICE:
Eachreceiverunitcanmanageupto7transmitterunits.If
7transmittershavebeenprogrammeddirectlyonareceiver,
thememoryisfullandawarningsignalwillsoundfor
10seconds.
7.7 Resetting the receiver
Keeptheprogrammingbuttononthereceiverpressedfor
about3seconds.LED1(green)ashesforabout1second.
Releasetheprogrammingbuttononthereceiver.
LED1(green)lightsupforabout8seconds.
The receiver memory is empty.
7.8 Adapting the transmission frequency
FactorysettingDIP1=OFF
“7.4Adaptingthe
transmissionfrequency“
869,85 MHz
868,95 MHz
7.8 / 1
DIP 1
7.9 Display LED 2 and 3
ON: SystemOK,safetyfunctionworking.
OFF: Closingedgesafetydevicetriggeredorsafetycircuit
interrupted.
14 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 15
7.10 2-channel external receiver [Rx 2.F]
F
A B C D
E
G H
7.10 / 1
Key:
A LED1(channel1)
A LED2(channel2)
C Programmingbutton
B LED1(status)
E DIPswitches
F J1(channel1)
G J2(channel2)
H TerminalsX1
7.11 Allocation of channel 1 connections
Transmission of a 8.2 kΩ closing edge safety device
Active in CLOSE direction
A
B
C
7.11 / 1
A
B
C
Connection to power supply
Control CS255/XB50-6/5
CS310/X4-1/2
A
B
C
Connection to a CESD 8.2 kΩ input
Control CS255/XP74-2/3
CS310/X4-5/6
“CESD“parametersetting–MOD 2
A
B
C
Test signal
Connectiontorelayoutput
CS255CS255/XH19
CS310/X5
“RELAY“parametersetting–MOD 22
2-channel system
14 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 15
EN
Transmission of a 8.2 kΩ closing edge safety device
Active in OPEN direction
A
B
C
7.11 / 2
A
B
C
Connection to power supply
Control CS255/XB50-6/5
CS310/X4-1/2
A
B
C
Connection to programmable input 2
Control CS255/XP74-2/5
CS310/X4-11/12
“INPUT2“parametersetting
– MOD 3 (stop and reverse)
– MOD 4 (stop and reversing movement)
A
B
C
Test signal
Connectiontorelayoutput
Control CS255/XH19
CS310/X5
“RELAY“parametersetting–MOD 41
Transmission of a safety device
A
B
C
7.11 / 3
A
B
C
Connection to power supply
Control CS255/XB50-6/5
CS310/X4-1/2
A
B
C
Connection to a safety circuit
Control CS255/XR51-1/2
CS310/X3-1/2
A
B
C
Test signal
Connectiontorelayoutput
Control CS255/XH19
CS310/X5
“RELAY“parametersetting–MOD 37
16 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 17
7.12 Allocation of channel 2 connections
Transmission of an OSE closing edge safety device
Active in CLOSE direction
A
B
C
7.12 / 1
A
B
C
Connection to power supply
Control CS255/XB50-6/5
CS310/X4-1/2
A
B
C
Connection to a CESD 8.2 kΩ input
Control CS255/XP74-2/3
CS310/X4-5/6
“CESD“parametersetting–MOD 2
A
B
C
Test signal
Connectiontorelayoutput
Control CS255/XH19
CS310/X5
“RELAY“parametersetting– MOD 26
Transmission of a 8.2 kΩ closing edge safety device
Active in CLOSE direction
A
B
C
7.12 / 2
A
B
C
Connection to power supply
Control CS255/XB50-6/5
CS310/X4-1/2
A
B
C
Connection to a CESD 8.2 kΩ input
Control CS255/XP74-2/3
CS310/X4-5/6
“CESD“parametersetting–MOD 2
A
B
C
Test signal
Connectiontorelayoutput
Control CS255/XH19
CS310/X5
“RELAY“parametersetting–MOD 22
2-channel system
16 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 17
EN
Transmission of a 8.2 kΩ closing edge safety device
Active in OPEN direction
A
B
C
7.12 / 3
A
B
C
Connection to power supply
Control CS255/XB50-6/5
CS310/X4-1/2
A
B
C
Connection to programmable input 2
Control CS255/XP74-2/5
CS310/X4-11/12
“INPUT2“parametersetting
– MOD 3 (stop and reverse)
– MOD 4 (stop and reversing movement)
A
B
C
Test signal
Connectiontorelayoutput
Control CS255/XH19
CS310/X5
“RELAY“parametersetting–MOD 41
Transmission of a safety device
A
B
C
7.12 / 4
A
B
C
Connection to power supply
Control CS255/XB50-6/5
CS310/X4-1/2
A
B
C
Connection to a safety circuit
Control CS255/XR51-1/2
CS310/X3-1/2
A
B
C
Test signal
Connectiontorelayoutput
Control CS255/XH19
CS310/X5
“RELAY“parametersetting–MOD 37
18 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 19
7.13 DIP switch setting
7.13 / 1
Safety application
ON: ActiveaccordingtoDINEN13849-1*
OFF: Inactive,safetyfunctionnotworking
Radioconnectionisnotmonitored
DIP1mustbesettoONforstandard-compliant
operation.
7.13 / 2
Transmission frequency
ON: 869.85MHz
OFF: 868.95MHz*
Thesettingsforthetransmitterandthereceivermust
beidentical.
“6.4Plug-inreceiver[SRTMODBANDMFZ]“
7.13 / 3
Type of test output contact
ON: NC
OFF: NO*
Thesettingdependsonthetypeoftestoutputcontact
on the control.
7.13 / 4
Activation of channel 2 output
ON: Generallyactive
OFF: Activationthroughexternalswitching
signal*
Ifanoptosensorsystemisconnected,DIP4mustbe
settoONandanactivationtimeprogrammed.
“7.14 Optosensor activation time“
7.13 / 5
Optosensor activation
ON: Wake-upfunctionactive
OFF: Wake-upfunctioninactive*
Only acts on channel 2.
Activationtriggeredbyeverydrivecommand.
Ifanoptosensorisconnected,DIP5mustbesetto
ONonthetransmitterandreceiver.
*Factorysettings
7.14 Optosensor activation time
Ifanoptosensorsystemisconnectedandtransmittedto
channel2,thetimeforwhichitshouldbeactivatedmust
beset.Otherwise,thesystemwouldcontinuallytrytomake
aconnectionandconstantlysupplytheoptosensorwith
power.Thebatteriesinthetransmitterwouldthencompletely
dischargewithinaveryshorttime.
Byprogrammingtheactivationtime,theoptosensorswillonly
besuppliedwithbatterypowerforthepresettime.Premature
batterydischargeispreventedasaresult.
Thefactorysettingis30secondsandmustbeadaptedtothe
conditionsattheplaceofuse.
Thefollowingmustbetakenintoaccount:
Theactivationtimemustbe at leastequaltothedoorrunning
timeandcanbesettoamaximumof4minutes.
Setting the activation time
Keeptheprogrammingbuttononthereceiverpressedfor
about2secondsuntilanacousticsignalsounds.
Releasetheprogrammingbuttononthereceiver.
LED1ison.
Keeptheprogrammingbuttononthereceiverpressedfor
about2secondsandthenreleaseit.LED1ashes.
Afterthedesiredtimehaselapsed,presstheprogramming
buttononthereceiveragainforabout2secondsandthen
release it.
Theactivationtimehasbeenchanged.
7.15 Programming
Keeptheprogrammingbuttononthereceiverpressedfor
about2secondsuntilanacousticsignalsounds.
Releasetheprogrammingbuttononthereceiver.
LED1lightsupforabout8seconds.
Duringthese8seconds,brieypresstheprogramming
buttononthetransmitteronce.
Anacousticsignalsounds.
Afterabout4seconds,2acousticsignalswillsoundone
aftertheother.LED1goesoff.
Iftheclosingedgesafetydevice/stopcircuitisworking
correctly,LED2willlightupcontinuouslyandsignalthatthe
transmitterhasbeenprogrammed.
2-channel system
Signal transmission system Protect Opto / Rev.C 0.2 – 19
EN
18 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 19
CHECK
Theremustbeadistanceofatleast1metrebetweenthe
transmitterandthereceiver.
NOTICE:
Eachreceiverunitcanmanageupto7transmitterunits.If
7transmittershavebeenprogrammeddirectlyonareceiver,
thememoryisfullandawarningsignalwillsoundfor
10seconds.
7.16 Resetting the receiver
Keeptheprogrammingbuttononthereceiverpressedfor
about2secondsuntilanacousticsignalsounds.
Keeptheprogrammingbuttononthereceiverpressedfor
about3secondsuntilseveralshortacousticsignalssound
oneaftertheother.
LED1ison.
Releasetheprogrammingbuttononthereceiver.
Afterabout10seconds,2acousticsignalswillsoundone
aftertheother.LED1goesoff.
The receiver memory is empty.
7.17 Display LED 2
ON: SystemOK,safetyfunctionworking
OFF: Closingedgesafetydevicetriggeredorsafetycircuit
interrupted.
Ifthebatterychargeistoolow,4warningsignalswillsound
inoneaftertheothereverytimethatthetransmittersends
information.Thetransmitterunitbatteriesmustthenbe
replacedimmediately.Itisrecommendedthatthebatteries
arereplacedatleastonceayearduringtheperiodicdoor
inspection.
8. Technical data
8.1 System
Frequencies: 868.95MHz
869.85MHz
Range: 10 m
Protection category IP 55
Dirtlevel: 2
Temperaturerange: -20°C…+55°C
8.2 1-channel transmitter
Batterypower: 2xlithium3V-typeCR2032
Powerconsumption: Transmissionmode: 17mA
Standby: 16μA
8.3 2-channel transmitter
Batterypower: 2xlithium3.6V-typeAA
Powerconsumption: Transmissionmode: 17mA
Standby: 16μA
8.4 1 or 2-channel external receiver
Supplyvoltage: 12/24VAC-DC
Transmittermemory: 7
Output: 1or2x24V/0.5Arelays
Micro-switch1B
Potential-freecontact
Powerconsumption: 0.5W/12V
1.2W/24V
Testsignalinput: 12/24VAC-DC
8.5 2-channel plug-in receiver
Supplyvoltage: 5VDCthroughCS310controlunit
Transmittermemory: 7
Output: Open collector
Testsignalinput: 3.3VDC
20 – Signal transmission system Protect Opto / Rev.C 0.2
9. Maintenance
Thetransmissionsystemmustbeinspectedduringtheannual
inspectionofthedoorsystemtocheckthatitisworking
correctlyandswitchesoffreliably.
Thebatteriesshouldbereplacedafternotmorethan
12months.
Life-threatening danger due to electric shock!
ThecontrolunitorswimmingpoolMUSTbedisconnected
fromtheelectricitysupplybeforecarryingoutany
electricalwork!Takemeasurestoensurethatthepower
supplyremainsdisconnectedforthedurationofthework.
Thefollowingpointsmustbetakenintoaccountwhen
carryingoutmaintenanceonthedoorsystem:
Maintenancemustonlybecarriedoutbyauthorised
persons.
Wornorfaultypartsmustbereplaced.
Onlyapprovedpartsmaybeinstalled.
Allmaintenanceworkmustbedocumented.
Replacedfaultpartsmustbedisposedofproperlyin
accordancewiththematerialstheycontainandlocal
regulations.
10. Disposal
Donotdisposeofoldequipmentor
batterieswiththenormalhousehold
waste!
Disposeofolddevicesatawastecollectioncentrefor
electronicwasteorviayourspecialistdealer.
Disposeofoldbatteriesinabatteryrecyclingcontaineror
viaaspecialistdealer.
Disposeofthepackagingmaterialinthespecialwaste
collectioncontainersforpaper,cardboardandplastic.
/