Marantec Protect-Opto 500 Owner's manual

Type
Owner's manual

This manual is also suitable for

EN
Signal transmission system Protect Opto / Rev.C 0.2 – 1
Operating Instructions
Signal transmission system Protect Opto 500|501|502
2 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 3
1. Contents
1. Contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2. Information in this document . . . . . . . . . . . . .3
3. General safety instructions . . . . . . . . . . . . . . .3
4. Overview of product . . . . . . . . . . . . . . . . . . . .4
4.1 General ...........................4
4.2 “1-channel“ system ..................4
4.3 “2-channel“ system ..................5
5. Initial operation . . . . . . . . . . . . . . . . . . . . . . . .6
5.1 General ...........................6
5.2 Externalinuences ...................6
5.3 Inputoftheclosingedgesystematthegate
control . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
6. 1-channel system . . . . . . . . . . . . . . . . . . . . . . .7
6.1 1-channeltransmitter[Tx1.0]...........7
6.2 Allocationofconnections ..............7
6.3 Adaptingthetransmissionfrequency......7
6.4 Plug-inreceiver[SRTMODBANDMFZ] ....8
6.5 Programming .......................8
6.6 Resetting the receiver .................8
6.7 Adaptingthetransmissionfrequency......8
6.8 DisplayLED2and3 ..................8
6.9 1-channelexternalreceiver[Rx1.0] ......9
6.10 Allocationofconnections ..............9
6.11 DIPswitchsetting...................10
6.12 Programming ......................10
6.13 Resetting the receiver ...............10
6.14 DisplayLED2 ......................10
7. 2-channel system . . . . . . . . . . . . . . . . . . . . . .11
7.1 2-channeltransmitter[Tx2.F] ..........11
7.2 AllocationofCHANNEL1connections....11
7.3 AllocationofCHANNEL2connections....11
7.4 Adaptingthetransmissionfrequency.....12
7.5 Plug-inreceiver[SRTMODBANDMFZ] ..13
7.6 Programming ......................13
7.7 Resetting the receiver ................13
7.8 Adaptingthetransmissionfrequency.....13
7.9 DisplayLED2and3 .................13
7.10 2-channelexternalreceiver[Rx2.F]......14
7.11 Allocationofchannel1connections .....14
7.12 Allocationofchannel2connections .....16
7.13 DIPswitchsetting...................18
7.14 Optosensor activation time ............18
7.15 Programming ......................18
7.16 Resetting the receiver ...............19
7.17 DisplayLED2 ......................19
8. Technical data . . . . . . . . . . . . . . . . . . . . . . . .19
8.1 System ...........................19
8.2 1-channel transmitter . . . . . . . . . . . . . . . . 19
8.3 2-channel transmitter . . . . . . . . . . . . . . . . 19
8.4 1 or 2-channel external receiver ........19
8.5 2-channelplug-inreceiver.............19
9. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . .20
10. Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
11. EC Declarations of conformity . . . . . . . . . . . .21
Signal transmission system Protect Opto / Rev.C 0.2 – 3
EN
2 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 3
Original operating instructions
Copyright.
Nopartoftheseinstructionsmaybereproducedwithout
ourpriorapproval.
Subjecttoalterationsintheinterestoftechnicalprogress.
Alldimensionsgiveninmm.
Thediagramsinthismanualarenottoscale.
Key to symbols
DANGER!
Indicatesahazardwithahighlevelofriskwhich,ifnot
avoided,willresultindeathorseriousinjury.
WARNING!
Indicatesahazardwithamediumlevelofriskwhich,ifnot
avoided,couldresultindeathorseriousinjury.
CAUTION!
Indicatesahazardwithalowlevelofriskwhich,ifnot
avoided,couldresultinminorormoderateinjury.
ATTENTION!
Indicatesanimminentdangerofdamageordestruction.
CHECK
Indicatesachecktobeperformed.
REFERENCE
Referencetoseparatedocumentswhichmustbecomplied
with.
Actionrequest
List,itemisation
Referencetoothersectionsofthisdocument
2. Information in this document 3. General safety instructions
DANGER!
Failure to comply with the documentation could
result in life-threatening danger!
Besuretofollowallthesafetyinstructionsinthis
document.
Warranty
Thefunctionandsafetyoftheequipmentisonlyguaranteed
ifthewarningandsafetyinstructionsincludedinthese
operatinginstructionsareadheredto.
MarantecGmbH+Co.KGisnotliableforpersonalinjuryor
damagetopropertyiftheseoccurasaresultofthewarnings
andsafetyadvicebeingdisregarded.
Marantecdoesnotacceptanyliabilityorwarrantyfordamage
duetotheuseofnon-approvedsparepartsandaccessories.
Intended use
Thesystemisforwirelesssignaltransmissionofsignalsto
doorsystemsandiscompatiblewithMaranteccontrols
CS255andCS310.Dependingonthesystem,signalscanbe
transmittedfromdifferentclosingedgesafetydevicesora
safetycircuit.
Theuseofaspiralcabletotransmitsignalsisnotnecessary.
Target group
Onlyqualiedandtrainedelectriciansmayconnect,
programmeandservicethesignaltransmissionsystem.
Qualiedandtrainedelectriciansmustmeetthefollowing
requirements:
knowledgeofthegeneralandspecicsafetyandaccident
preventionregulations,
knowledgeoftherelevantelectricalregulations,
trainingintheuseandcareofappropriatesafety
equipment,
capableofrecognisingthedangersassociatedwith
electricity.
Instructions regarding installation and connection
Thecontrolmustbedisconnectedfromtheelectricity
supplybeforecarryingoutanyelectricalwork.Itmustbe
ensuredthattheelectricitysupplyremainsdisconnectedfor
thedurationofthework.
Localprotectiveregulationsmustbecompliedwith.
4 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 5
4 – Signal transmission system Protect Opto / Rev.C 0.2
Information concerning operation
Unauthorisedpersons(particularlychildren)shouldnotbe
allowedtoplaywithpermanentlyinstalledadjustingor
controldevices.
Keepremotecontrolsbeyondthereachofchildren.
Observethevalidstandardsandregulations!
4. Overview of product
4.1 General
Thisisabidirectionalradiotransmissionsystemfor
connectingsafetydevicesforautomaticdoordrives.
Theradiocontactisbetweenareceiverunitwhichis
connectedtothedrivecontrolandatransmitterunitwhichis
attachedtothedoor.
Either
anenergy-savingoptoelectronic(lowpower)closingedge
safetydevice,
an8.2kΩresistanceswitchingstrip,or
aswitchingcontact
canbeconnectedtothetransmitterunit.
Eachreceiverunitcanmanageupto7transmitterunits.The
systemhasarangeofabout10metres.Theresponsetime
ofthesystemwhenaswitchingstripisactivatedislessthan
100 ms.
Itispossibletousemorethanoneradiotransmissionsystem
inabuildingprojectwithoutresultingininterferencebetween
the systems.
Thetransmitterunitsarebattery-poweredandunderideal
conditionshaveabatterylifeofabout2yearsiftwobatteries
areused.Intheeventofahighnumberofswitchingcycles,
orbadtransmittingconditionsoradverseweatherconditions,
thebatterywillhaveaconsiderablyshorterlife.
Itisrecommendedthatthebatteriesarereplacedduringthe
annualservice.
4.2 “1-channel“ system
The“1-channel“systemconsistsof
anexternaltransmitter,thatcantransmiteither1closing
edgesafetydeviceonan8.2kΩbasisorasafetycircuit
withapotential-freeNCcontact.
anexternalreceiverthatcanbeconnectedwithacableto
MaranteccontrolsCS255andCS310
or
aplug-inreceiverwhichcanonlybeusedinconjunction
withMaranteccontrolCS310.
General safety instructions
4 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 5
EN
4.3 “2-channel“ system
The“2-channel“systemconsistsof
anexternaltransmitterthatcantransmitthefollowing
combinationsofsafetycomponents:
1xoptosensorclosingedgesafetydeviceand
1x8.2kΩclosingedgesafetydevice
1xoptosensorclosingedgesafetydeviceand
1xNC/NOsafetycircuit
2x8.2kΩclosingedgesafetydevice
1x8.2kΩclosingedgesafetydeviceand
1xNC/NOsafetycircuit
anexternalreceiverthatcanbeconnectedwithacableto
MaranteccontrolsCS255andCS310
or
aplug-inreceiverwhichcanonlybeusedinconjunction
withMaranteccontrolCS310.
4.3 / 1 4.3 / 2 4.3 / 3
1-channel transmitter
Tx 1.0
“6.1 1-channel
transmitter[Tx1.0]“
2-channel transmitter
Tx2.F
“7.1 2-channel
transmitter[Tx2.F]“
4.3 / 4 4.3 / 5
1-channel external receiver Rx 1.0
“6.91-channelexternalreceiver[Rx1.0]“
4.3 / 6
4.3 / 7
2-channelexternalreceiverRx2.F
“7.102-channelexternalreceiver[Rx2.F]“
4.3 / 8
2-channelplug-inreceiver–>onlyforcontrolCS310
“6.4Plug-inreceiver[SRTMODBANDMFZ]“
“7.5Plug-inreceiver[SRTMODBANDMFZ]“
6 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 7
5.1 General
Toguaranteethattheequipmentfunctionsproperly,itmust
beensuredthat:
Thedoorisinstalledandoperational.
Thedrivemotorisinstalledandreadyforoperation.
Thedoorcontrolisinstalledandreadyforoperation.
Thecommandandsafetydevicesareinstalledandreadyfor
operation.
REFERENCE
Therelevantmanufacturers’instructionsmustbeadheredto
wheninstallingthedoor,theMarantecdrivemotor,andthe
commandandsafetydevices.
5.2 External inuences
Requirements
Toensureproperoperationofthesystem,thefollowing
conditionsmustbemet:
Theremustnotbeanymetalsurfacesbetweenthe
transmitterandthereceiver.
Theremustnotbeastrongmagneticeldorotherwireless
systemsinthedirectvicinityofthesystem.
Theremustbeadistanceofatleast1metrebetweenthe
transmitterandthereceiver.
ATTENTION!
Malfunctions due to external inuences!
Thesignaltransmissionsystemgenerallyhasarangeofat
least 10 metres.
Localconditionshowevercouldcauseareductioninthe
rangeeventothepointoftotalfailureofthesystem
(Examples:high-voltagelines,magneticelds,radio
masts,otherradiosystems,wallsandceilingsofreinforced
concrete,steelconstructionsinindustrialhalls,frequency-
controlledmachineryetc.).
5. Initial operation
5.3 Input of the closing edge system at the
gate control
Inordertoavoidmalfunctions,theinputoftheclosingedge
systemontheMarantecgatecontrolsCS310andCS255
mustbeequippedwithan8.2kΩresistorandcongured
accordingly.
Otherwise,anerrormessageisdisplayedconstantlyatthis
pointduetothe“missing”closingedgeprotectivedevice.
Pulseorautomaticoperationarethennolongerpossible.
Gate control CS310 (X4)
ParameterSKS=MOD2
8k2
1
2
3
4
5
6
7
8
9
12
11
10
X4
5.3 / 1
Gate control CS255 (XP74)
ParameterSKS=MOD2
XP74
45
40
47
+
8k2
5.3 / 2
NOTICE:
Whenusinggatecontrolsfromothermanufacturers:
Requestthenecessarycongurationorpre-settingsfromthe
technicalservicedepartmentoftherespectivemanufacturer.
6 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 7
EN
6.2 Allocation of connections
Connection of a 8.2 kΩ closing edge safety device
6.2 / 1
Closingedgesafetydevice DIP 1
Connection of a safety device
6.2 / 2
NCsafetydevice
e.g.slackropeswitch
DIP 1
6.3 Adapting the transmission frequency
FactorysettingDIP2=OFF
DIP 2
6.3 / 1
DIP 2
6.3 / 2
869.85MHz 868.95MHz
CHECK
Thesettingonthetransmitterandreceivermustbe
identical.
6. 1-channel system
6.1 1-channel transmitter [Tx1.0]
A
B
C
D
E
F
6.1 / 1
Key:
A Programmingbutton
B DIPswitches
C LED1
D Battery2
E Battery1
F TerminalX1
8 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 9
6.4 Plug-in receiver [SRTMODBANDMFZ]
Circuit board CS310 / plug-in socket X20
6.4 / 1
A
B
C
D
E
Key:
A LED3(red/channel2)
B DIPswitches
C LED2(red/channel1)
D Programmingbutton
E LED1(green/status)
OnlyinconjunctionwithMarantecCS310controlfrom
softwareversion1.30upwards.
Theplug-inreceiverisa2-channelreceiver.Ifa1-channel
transmitterisprogrammed(taught-in),channel1isalways
theprogrammedchannelandcorrespondstoparameter
CESD3.
REFERENCE
Moreinformationisgivenintheoperatinginstructionsfor
the CS310 control.
6.5 Programming
Keeptheprogrammingbuttononthereceiverpressedfor
about1second.
Releasetheprogrammingbuttononthereceiver.
LED1(green)lightsupforabout8seconds.
Duringthese8seconds,brieypresstheprogramming
buttononthetransmitteronce.
Afterabout4seconds,LED1(green)willgooff.
Iftheclosingedgesafetydevice/stopcircuitisworking
correctly,LED2(red)willlightupcontinuouslyandsignal
thatchannel1hasbeenprogrammed.Thetransmitterisnow
programmed(taught-in).
CHECK
Theremustbeadistanceofatleast1metrebetweenthe
transmitterandthereceiver.
NOTICE:
Eachreceiverunitcanmanageupto7transmitterunits.If
7transmittershavebeenprogrammeddirectlyonareceiver,
thememoryisfullandawarningsignalwillsoundfor
10seconds.
6.6 Resetting the receiver
Keeptheprogrammingbuttononthereceiverpressedfor
about3seconds.LED1(green)ashesforabout1second.
Releasetheprogrammingbuttononthereceiver.
LED1(green)lightsupforabout8seconds.
The receiver memory is empty.
6.7 Adapting the transmission frequency
FactorysettingDIP1=OFF
“6.3Adaptingthe
transmissionfrequency“
869,85 MHz
868,95 MHz
DIP 1
6.8 Display LED 2 and 3
ON: SystemOK,safetyfunctionworking.
OFF: Closingedgesafetydevicetriggeredorsafetycircuit
interrupted.
1-channel system
8 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 9
EN
6.9 1-channel external receiver [Rx 1.0]
A
B
C
D
E
6.9 / 1
Key:
A DIPswitches
B LED1(status)
C LED2
(channel1)
D Programming
button
E TerminalX1
6.10 Allocation of connections
Connection of an 8.2 kΩ closing edge safety device
Active in CLOSE direction
A
B
C
6.10 / 1
A
B
C
Connection to power supply
Control CS255/XB50-6/5
CS310/X4-1/2
A
B
C
Connection to a CESD 8.2 kΩ input
Control CS255/XP74-2/3
CS310/X4-5/6
“CESD“parametersetting–MOD 2
A
B
C
Test signal
Connectiontorelayoutput
CS255CS255/XH19
CS310/X5
“RELAY“parametersetting–MOD 22
Transmission of a 8.2 kΩ closing edge safety device
Active in OPEN direction
A
B
C
6.10 / 2
A
B
C
Connection to power supply
Control CS255/XB50-6/5
CS310/X4-1/2
A
B
C
Connection to programmable input 2
Control CS255/XP74-2/5
CS310/X4-11/12
“INPUT2“parametersetting
– MOD 3 (stop and reverse)
– MOD 4 (stop and reversing movement)
A
B
C
Test signal
Connectiontorelayoutput
Control CS255/XH19
CS310/X5
“RELAY“parametersetting–MOD 41
Transmission of a safety device
A
B
C
6.10 / 3
A
B
C
Connection to power supply
Control CS255/XB50-6/5
CS310/X4-1/2
A
B
C
Connection to a safety circuit
Control CS255/XR51-1/2
CS310/X3-1/2
A
B
C
Test signal
Connectiontorelayoutput
CS255CS255/XH19
CS310/X5
“RELAY“parametersetting– MOD 37
10 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 11
6.11 DIP switch setting
6.11 / 1
Safety application
ON: ActiveaccordingtoDINEN13849-1*
OFF: Inactive,safetyfunctionnotworking
Radioconnectionisnotmonitored
DIP1mustbesettoONforstandard-compliant
operation.
6.11 / 2
Transmission frequency
ON: 869.85MHz
OFF: 868.95MHz*
Thesettingsforthetransmitterandthereceivermust
beidentical.
“6.4Plug-inreceiver[SRTMODBANDMFZ]“
6.11 / 3
Type of test output contact
ON: NC
OFF: NO*
Thesettingdependsonthetypeoftestoutputcontact
on the control.
6.11 / 4
Automatic frequency adaptation
ON: Active
OFF: Inactive*
Onlyactivateifthereissevereradiointerference
*Factorysettings
6.12 Programming
Keeptheprogrammingbuttononthereceiverpressedfor
about2secondsuntilanacousticsignalsounds.
Releasetheprogrammingbuttononthereceiver.
LED1lightsupforabout8seconds.
Duringthese8seconds,brieypresstheprogramming
buttononthetransmitteronce.
Anacousticsignalsounds.
Afterabout4seconds,2acousticsignalswillsoundone
aftertheother.LED1goesoff.
Iftheclosingedgesafetydevice/stopcircuitisworking
correctly,LED2willlightupcontinuouslyandsignalthatthe
transmitterhasbeenprogrammed.
1-channel system
CHECK
Theremustbeadistanceofatleast1metrebetweenthe
transmitterandthereceiver.
NOTICE:
Eachreceiverunitcanmanageupto7transmitterunits.If
7transmittershavebeenprogrammeddirectlyonareceiver,
thememoryisfullandawarningsignalwillsoundfor
10seconds.
6.13 Resetting the receiver
Keeptheprogrammingbuttononthereceiverpressedfor
about2secondsuntilanacousticsignalsounds.
Keeptheprogrammingbuttononthereceiverpressedfor
about3secondsuntilseveralshortacousticsignalssound
oneaftertheother.
LED1ison.
Releasetheprogrammingbuttononthereceiver.
Afterabout10seconds,2acousticsignalswillsoundone
aftertheother.LED1goesoff.
The receiver memory is empty.
6.14 Display LED 2
ON: SystemOK,safetyfunctionworking.
OFF: Closingedgesafetydevicetriggeredorsafetycircuit
interrupted.
CHECK
Ifthebatterychargeistoolow,4consecutivewarning
signalswillsoundeverytimethatthetransmittersends
information.Thetransmitterunitbatteriesmustthenbe
replacedimmediately.Itisrecommendedthatthebatteries
arereplacedatleastonceayearduringtheperiodicdoor
inspection.
10 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 11
EN
7. 2-channel system
7.1 2-channel transmitter [Tx2.F]
D
C
F
B
A
E
7.1 / 1
Key:
A LED
B Programming
button
C DIPswitches
D Battery1
E Battery2
F TerminalX1
7.2 Allocation of CHANNEL 1 connections
Connection of a safety device
7.2 / 1
NCsafetydevice
e.g.slackropeswitch
TheNCtypeofcontactispreprogrammedinthefactoryand
cannotbereprogrammedtoaNOcontact.
Connection of an 8.2 kΩ closing edge safety device
7.2 / 2
Closingedgesafetydevice
NOTICE:
Ifchannel1isnotused:
Fitawirejumperonterminals1-2.
SetDIP1toOFF.
Bothchannelsarecheckedduringthetestroutine.
Ifnothingisconnectedtoachannel,anerrormessageis
issuedandthefunctionisnolongeravailable.
7.3 Allocation of CHANNEL 2 connections
Channel2canbeusedtoconnectandprogramme
differentcomponents:
Optosensor(OSE)closingedgesafetydevice
Electricalcontactbaroftheclosingedgesafetydevice
SafetydevicewithNCcontact
Componentselectioniscarriedoutin2stages.
Step 1:
Insertbatteries1and2.
AnLED(red)statusreportisgiven.
Flashes2times:
OneOSEsystemiscurrentlyprogrammed
(factorysetting).
Flashes5times:
One8.2kΩsystemand/oraNCcontactiscurrently
programmed.
Tochangethesystem,keeptheprogrammingbutton on the
transmitterpressedforatleast2seconds.
Thesettingischanged.
AnewstatusreportisgivenbytheLEDaboutthecurrent
status.
Flashes2times:OSEsystem
Flashes5times:8.2kΩ/NCcontact
Thecomponentselectionischanged.
12 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 13
After inserting battery 1, only 10 seconds time is left
to change the component selection.
Step 2:
UseDIPswitch2tomakethefurtherselection.
IftheOSEsystemisprogrammed,DIPswitch2must
generallybesetto ON.
Ifa8.2kΩsystemand/oraNCcontactisprogrammed,
DIPswitch2mustbesettoON
ifa8.2kΩsystemisconnected.
DIPswitch2mustbesettoOFF
ifaNCcontactisconnected.
Connection of an OSE closing edge safety device
7.3 / 1
Closingedgesafetydevice
4 white
5 green
6 brown
Connection of an 8.2 kΩ closing edge safety device
7.3 / 2
Closingedgesafetydevice
Connection of a safety device
7.3 / 3
NCsafetydevice
e.g.slackropeswitch
NOTICE:
Ifchannel2isnotused:
Fitawirejumperonterminals4-5.
SetDIP2toOFF.
Bothchannelsarecheckedduringthetestroutine.
Ifnothingisconnectedtoachannel,anerrormessageis
issuedandthefunctionisnolongeravailable.
7.4 Adapting the transmission frequency
FactorysettingDIP3=OFF
DIP 3
7.4 / 1
DIP 3
7.4 / 2
869.85MHz 868.95MHz
CHECK
Thesettingonthetransmitterandreceivermustbe
identical.
2-channel system
12 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 13
EN
7.5 Plug-in receiver [SRTMODBANDMFZ]
Circuit board CS310 / Plug-in socket X20
7.5 / 1
A
B
C
D
E
Key:
A LED3(red/channel2)
B DIPswitches
C LED2(red/channel1)
D Programmingbutton
E LED1(green/status)
OnlyinconjunctionwithMarantecCS310controlfrom
softwareversion1.30upwards.
Channel2correspondstoparameterCESD3oftheCS310.
Channel2correspondstoparameterCESD4oftheCS310.
Moreinformationisgivenintheoperatinginstructionsfor
the CS310 control.
7.6 Programming
Keeptheprogrammingbuttononthereceiverpressedfor
about1second.
Releasetheprogrammingbuttononthereceiver.
LED1(green)lightsupforabout8seconds.
Duringthese8seconds,brieypresstheprogramming
buttononthetransmitteronce.
Afterabout4seconds,LED1(green)willgooff.
Iftheclosingedgesafetydevice/stopcircuitisworking
correctly,LED2(red)andLED3(red)willlightup
continuouslyandsignalisethatchannel1hasbeen
programmed.Thetransmitterisnowprogrammed(taught-in).
NOTICE:
Eachreceiverunitcanmanageupto7transmitterunits.If
7transmittershavebeenprogrammeddirectlyonareceiver,
thememoryisfullandawarningsignalwillsoundfor
10seconds.
7.7 Resetting the receiver
Keeptheprogrammingbuttononthereceiverpressedfor
about3seconds.LED1(green)ashesforabout1second.
Releasetheprogrammingbuttononthereceiver.
LED1(green)lightsupforabout8seconds.
The receiver memory is empty.
7.8 Adapting the transmission frequency
FactorysettingDIP1=OFF
“7.4Adaptingthe
transmissionfrequency“
869,85 MHz
868,95 MHz
7.8 / 1
DIP 1
7.9 Display LED 2 and 3
ON: SystemOK,safetyfunctionworking.
OFF: Closingedgesafetydevicetriggeredorsafetycircuit
interrupted.
14 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 15
7.10 2-channel external receiver [Rx 2.F]
F
A B C D
E
G H
7.10 / 1
Key:
A LED1(channel1)
A LED2(channel2)
C Programmingbutton
B LED1(status)
E DIPswitches
F J1(channel1)
G J2(channel2)
H TerminalsX1
7.11 Allocation of channel 1 connections
Transmission of a 8.2 kΩ closing edge safety device
Active in CLOSE direction
A
B
C
7.11 / 1
A
B
C
Connection to power supply
Control CS255/XB50-6/5
CS310/X4-1/2
A
B
C
Connection to a CESD 8.2 kΩ input
Control CS255/XP74-2/3
CS310/X4-5/6
“CESD“parametersetting–MOD 2
A
B
C
Test signal
Connectiontorelayoutput
CS255CS255/XH19
CS310/X5
“RELAY“parametersetting–MOD 22
2-channel system
14 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 15
EN
Transmission of a 8.2 kΩ closing edge safety device
Active in OPEN direction
A
B
C
7.11 / 2
A
B
C
Connection to power supply
Control CS255/XB50-6/5
CS310/X4-1/2
A
B
C
Connection to programmable input 2
Control CS255/XP74-2/5
CS310/X4-11/12
“INPUT2“parametersetting
– MOD 3 (stop and reverse)
– MOD 4 (stop and reversing movement)
A
B
C
Test signal
Connectiontorelayoutput
Control CS255/XH19
CS310/X5
“RELAY“parametersetting–MOD 41
Transmission of a safety device
A
B
C
7.11 / 3
A
B
C
Connection to power supply
Control CS255/XB50-6/5
CS310/X4-1/2
A
B
C
Connection to a safety circuit
Control CS255/XR51-1/2
CS310/X3-1/2
A
B
C
Test signal
Connectiontorelayoutput
Control CS255/XH19
CS310/X5
“RELAY“parametersetting–MOD 37
16 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 17
7.12 Allocation of channel 2 connections
Transmission of an OSE closing edge safety device
Active in CLOSE direction
A
B
C
7.12 / 1
A
B
C
Connection to power supply
Control CS255/XB50-6/5
CS310/X4-1/2
A
B
C
Connection to a CESD 8.2 kΩ input
Control CS255/XP74-2/3
CS310/X4-5/6
“CESD“parametersetting–MOD 2
A
B
C
Test signal
Connectiontorelayoutput
Control CS255/XH19
CS310/X5
“RELAY“parametersetting– MOD 26
Transmission of a 8.2 kΩ closing edge safety device
Active in CLOSE direction
A
B
C
7.12 / 2
A
B
C
Connection to power supply
Control CS255/XB50-6/5
CS310/X4-1/2
A
B
C
Connection to a CESD 8.2 kΩ input
Control CS255/XP74-2/3
CS310/X4-5/6
“CESD“parametersetting–MOD 2
A
B
C
Test signal
Connectiontorelayoutput
Control CS255/XH19
CS310/X5
“RELAY“parametersetting–MOD 22
2-channel system
16 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 17
EN
Transmission of a 8.2 kΩ closing edge safety device
Active in OPEN direction
A
B
C
7.12 / 3
A
B
C
Connection to power supply
Control CS255/XB50-6/5
CS310/X4-1/2
A
B
C
Connection to programmable input 2
Control CS255/XP74-2/5
CS310/X4-11/12
“INPUT2“parametersetting
– MOD 3 (stop and reverse)
– MOD 4 (stop and reversing movement)
A
B
C
Test signal
Connectiontorelayoutput
Control CS255/XH19
CS310/X5
“RELAY“parametersetting–MOD 41
Transmission of a safety device
A
B
C
7.12 / 4
A
B
C
Connection to power supply
Control CS255/XB50-6/5
CS310/X4-1/2
A
B
C
Connection to a safety circuit
Control CS255/XR51-1/2
CS310/X3-1/2
A
B
C
Test signal
Connectiontorelayoutput
Control CS255/XH19
CS310/X5
“RELAY“parametersetting–MOD 37
18 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 19
7.13 DIP switch setting
7.13 / 1
Safety application
ON: ActiveaccordingtoDINEN13849-1*
OFF: Inactive,safetyfunctionnotworking
Radioconnectionisnotmonitored
DIP1mustbesettoONforstandard-compliant
operation.
7.13 / 2
Transmission frequency
ON: 869.85MHz
OFF: 868.95MHz*
Thesettingsforthetransmitterandthereceivermust
beidentical.
“6.4Plug-inreceiver[SRTMODBANDMFZ]“
7.13 / 3
Type of test output contact
ON: NC
OFF: NO*
Thesettingdependsonthetypeoftestoutputcontact
on the control.
7.13 / 4
Activation of channel 2 output
ON: Generallyactive
OFF: Activationthroughexternalswitching
signal*
Ifanoptosensorsystemisconnected,DIP4mustbe
settoONandanactivationtimeprogrammed.
“7.14 Optosensor activation time“
7.13 / 5
Optosensor activation
ON: Wake-upfunctionactive
OFF: Wake-upfunctioninactive*
Only acts on channel 2.
Activationtriggeredbyeverydrivecommand.
Ifanoptosensorisconnected,DIP5mustbesetto
ONonthetransmitterandreceiver.
*Factorysettings
7.14 Optosensor activation time
Ifanoptosensorsystemisconnectedandtransmittedto
channel2,thetimeforwhichitshouldbeactivatedmust
beset.Otherwise,thesystemwouldcontinuallytrytomake
aconnectionandconstantlysupplytheoptosensorwith
power.Thebatteriesinthetransmitterwouldthencompletely
dischargewithinaveryshorttime.
Byprogrammingtheactivationtime,theoptosensorswillonly
besuppliedwithbatterypowerforthepresettime.Premature
batterydischargeispreventedasaresult.
Thefactorysettingis30secondsandmustbeadaptedtothe
conditionsattheplaceofuse.
Thefollowingmustbetakenintoaccount:
Theactivationtimemustbe at leastequaltothedoorrunning
timeandcanbesettoamaximumof4minutes.
Setting the activation time
Keeptheprogrammingbuttononthereceiverpressedfor
about2secondsuntilanacousticsignalsounds.
Releasetheprogrammingbuttononthereceiver.
LED1ison.
Keeptheprogrammingbuttononthereceiverpressedfor
about2secondsandthenreleaseit.LED1ashes.
Afterthedesiredtimehaselapsed,presstheprogramming
buttononthereceiveragainforabout2secondsandthen
release it.
Theactivationtimehasbeenchanged.
7.15 Programming
Keeptheprogrammingbuttononthereceiverpressedfor
about2secondsuntilanacousticsignalsounds.
Releasetheprogrammingbuttononthereceiver.
LED1lightsupforabout8seconds.
Duringthese8seconds,brieypresstheprogramming
buttononthetransmitteronce.
Anacousticsignalsounds.
Afterabout4seconds,2acousticsignalswillsoundone
aftertheother.LED1goesoff.
Iftheclosingedgesafetydevice/stopcircuitisworking
correctly,LED2willlightupcontinuouslyandsignalthatthe
transmitterhasbeenprogrammed.
2-channel system
Signal transmission system Protect Opto / Rev.C 0.2 – 19
EN
18 – Signal transmission system Protect Opto / Rev.C 0.2 Signal transmission system Protect Opto / Rev.C 0.2 – 19
CHECK
Theremustbeadistanceofatleast1metrebetweenthe
transmitterandthereceiver.
NOTICE:
Eachreceiverunitcanmanageupto7transmitterunits.If
7transmittershavebeenprogrammeddirectlyonareceiver,
thememoryisfullandawarningsignalwillsoundfor
10seconds.
7.16 Resetting the receiver
Keeptheprogrammingbuttononthereceiverpressedfor
about2secondsuntilanacousticsignalsounds.
Keeptheprogrammingbuttononthereceiverpressedfor
about3secondsuntilseveralshortacousticsignalssound
oneaftertheother.
LED1ison.
Releasetheprogrammingbuttononthereceiver.
Afterabout10seconds,2acousticsignalswillsoundone
aftertheother.LED1goesoff.
The receiver memory is empty.
7.17 Display LED 2
ON: SystemOK,safetyfunctionworking
OFF: Closingedgesafetydevicetriggeredorsafetycircuit
interrupted.
Ifthebatterychargeistoolow,4warningsignalswillsound
inoneaftertheothereverytimethatthetransmittersends
information.Thetransmitterunitbatteriesmustthenbe
replacedimmediately.Itisrecommendedthatthebatteries
arereplacedatleastonceayearduringtheperiodicdoor
inspection.
8. Technical data
8.1 System
Frequencies: 868.95MHz
869.85MHz
Range: 10 m
Protection category IP 55
Dirtlevel: 2
Temperaturerange: -20°C…+55°C
8.2 1-channel transmitter
Batterypower: 2xlithium3V-typeCR2032
Powerconsumption: Transmissionmode: 17mA
Standby: 16μA
8.3 2-channel transmitter
Batterypower: 2xlithium3.6V-typeAA
Powerconsumption: Transmissionmode: 17mA
Standby: 16μA
8.4 1 or 2-channel external receiver
Supplyvoltage: 12/24VAC-DC
Transmittermemory: 7
Output: 1or2x24V/0.5Arelays
Micro-switch1B
Potential-freecontact
Powerconsumption: 0.5W/12V
1.2W/24V
Testsignalinput: 12/24VAC-DC
8.5 2-channel plug-in receiver
Supplyvoltage: 5VDCthroughCS310controlunit
Transmittermemory: 7
Output: Open collector
Testsignalinput: 3.3VDC
20 – Signal transmission system Protect Opto / Rev.C 0.2
9. Maintenance
Thetransmissionsystemmustbeinspectedduringtheannual
inspectionofthedoorsystemtocheckthatitisworking
correctlyandswitchesoffreliably.
Thebatteriesshouldbereplacedafternotmorethan
12months.
Life-threatening danger due to electric shock!
ThecontrolunitorswimmingpoolMUSTbedisconnected
fromtheelectricitysupplybeforecarryingoutany
electricalwork!Takemeasurestoensurethatthepower
supplyremainsdisconnectedforthedurationofthework.
Thefollowingpointsmustbetakenintoaccountwhen
carryingoutmaintenanceonthedoorsystem:
Maintenancemustonlybecarriedoutbyauthorised
persons.
Wornorfaultypartsmustbereplaced.
Onlyapprovedpartsmaybeinstalled.
Allmaintenanceworkmustbedocumented.
Replacedfaultpartsmustbedisposedofproperlyin
accordancewiththematerialstheycontainandlocal
regulations.
10. Disposal
Donotdisposeofoldequipmentor
batterieswiththenormalhousehold
waste!
Disposeofolddevicesatawastecollectioncentrefor
electronicwasteorviayourspecialistdealer.
Disposeofoldbatteriesinabatteryrecyclingcontaineror
viaaspecialistdealer.
Disposeofthepackagingmaterialinthespecialwaste
collectioncontainersforpaper,cardboardandplastic.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Marantec Protect-Opto 500 Owner's manual

Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI