Pinnacle Technology OS2CX User manual

Type
User manual

This manual is also suitable for

OS2X CHECKOUT SCALE
USER MANUAL
Pinnacle Technology Corp.
CONTENTS
1. SUMMARIZATION ............................................................................................................................... 1
1.1 ADVANCED FUNCTIONS ........................................................................................................ 1
1.2 EXCELLENT FUNCTIONS ....................................................................................................... 1
2. TECHNICAL SPECIFICATION ............................................................................................................ 2
3. APPEARANCE ...................................................................................................................................... 3
4. DIMENSION .......................................................................................................................................... 5
5. HOW TO FIX CUSTOMER DISPLAY TO CHECKOUT SCALE....................................................... 7
6. HOW TO INSTALL DISPLAY POLE ................................................................................................... 8
7. POWER CONNECTIONS ..................................................................................................................... 9
8. POWER ON/OFF ................................................................................................................................. 11
9. KEY EXPLANATION ......................................................................................................................... 11
10. WARNING ........................................................................................................................................ 12
11. SOFTWARE OPERATION .............................................................................................................. 12
12. USB VIRTUAL SERIAL PORT DRIVER INSTALLATION .......................................................... 13
13. COMMUNICATION PROTOCOL .................................................................................................. 15
1
1. SUMMARIZATION
1.1 ADVANCED FUNCTIONS
Communication platter which adopts patent insect-proof design can prevent the machine from
defects caused by insects.
Can be used as stand-alone, or connect with POS/ECR.
Imbedded design to save valuable counter space.
Optional wireless typeable to transmit weighting data to POS/ECR in time without lines.
Patent tempered glass platter, practical and good looking.
1.2 EXCELLENT FUNCTIONS
Two options of customer display: external or in-built, able to meet customers‟ need in all-round.
Tare, zero and other function keys on the display, easy to operate and convenient to check out the
weighting information.
Simple elegant design and compact internal process guarantee products‟ reliability and aesthetics.
Standard protocol, convenient to connect with POS/ECR.
Two optional measuring range: 15kge=2g/5gor 30kge=5g/10g.
2
2. TECHNICAL SPECIFICATION
Specification of types
Desktop Type OS2CX
Imbedded Type OS2IX
OS2CX
OS2CXK
OS2CXB
OS2CXP
OS2IXD
Basic Features
without display
without keys
without display;
with two keys
with pedestal display
& three keys
with display, pole
& three keys
With separate pole;
display & three keys
Dimension
344.93*262.54
*87.8mm
344.93*262.54
*87.8mm
344.93*343.2
*91.04mm
435.22*344.93
*337.87mm
Platter
370*288*
72.4mm
Display pole
415.72*111.57
*86.35mm
Customer/Operator Display
5*8 field LCD
Weighing Capacity (Max.)
6/15kg;15/30kg
Division Value
2/5g;5/10g
Weighing Capacity (Min.)
40g;100g
Tare (Max.)
-5.998kg;-14.995kg
Internal Resolution
1/30000
Accuracy Class
Interface
RS232
Optional
USB2.4G wifi communication
Power Supply
5V 1A
Working Temperature
0-40
Working Humidity
5%R.H.-85%R.H.
3
3. APPEARANCE
OS2CX
OS2CXK
OS2CXB
OS2IX
OS2CX is the type without display screen
& keys.
Without display screen, but with two key
(tare key and zero key)
Display screen is on the pedestal, with
three keys.
Embedded type, without display screen
but with two keys.
4
OS2CXP
OS2IXD
With display screen and three keys.
With separate display screen, three key.
Display screens position can be installed
according to actual needs.
5
4. DIMENSION
outline dimensional drawing
OS2CX/OS2CXK
OS2CXB
OS2CXP
OS2IX
6
Installing hole dimension figure of OS2IX type
OS2IXD
OS2IXD-platter
OS2IXD-display pole
7
5. HOW TO FIX CUSTOMER DISPLAY TO CHECKOUT SCALE
Please follow below steps to install the customer display, if the type you bought with it.
Insert the line to the port
Lock the screws
8
6. HOW TO INSTALL DISPLAY POLE
Please follow below steps to install the display pole, if the type you bought with it.
Lock the screws to
fix the display pole
on the pedestal
Lock the screws to
fix the display pole
on the bottom of
the platform.
Fix the pole
like the
picture shows.
9
7. POWER CONNECTIONS
There are 3 methods for OS2X to get power supply.
Method 1: Use the attached communication line to connect Aclas ECR as below picture.
Customer can self-define the length of communication line, if the line is too long,
customer can cut one end of crystal head short and follow the connection mode below to
make a new one.
PHONE4
Pin
Signal name
1
VDD
2
GND
3
TXD
4
RXD
PHONE4
Pin
Signal name
1
VDD
2
GND
3
RXD
4
TXD
Connect to
OS2X
Connect to Aclas ECR
or LP1X label printer
RS232 line
Able to self-define the length
Connection mode
10
Method 2If the external device or PC is attached with D9 interface, customer can use a
D9-4P communication cable with USB interface from Aclas to get power supply.
Connect the OS2X with the external device as below picture. If supply power is
available from the D9 interface of external device, there is no need to connect with other
power supply.
Method 3 If you purchased USB line, you can follow below picture to connect OS2X
and other terminal with USB port.
Note: To set the communication between the OS2X and the external device that has USB
interface, users should install USB virtual serial port driver first. Please refer to related
chapter for details.
Connect to USB
port of PC or
other terminal
Connect to
OS2X
Connect to D9
port of PC or
other terminal
Communication line, connect to
OS2 (Able to self-define the length)
Power plug
If the line is too short, use
USB cable to prolong it
Connect PC or
power supply
11
8. POWER ON/OFF
Power on: press the key to power on after soft turning off.
Power off: press the key to power off.
9. KEY EXPLANATION
: This key is to adjust the WEIGHT column to zero value.
Place the scale level steadily, if there are digits displayed on LCD when there is nothing on the
platter, you can press this key to adjust to zero.
Press this key and hold it for 1.5 seconds to turn on or turn off the backlight.
: This key is used to deduct the packing weight.
If you need to deduct the packing weight, put the container or wrapper on the scale first, and
then press this key to enter weight- deducting state. Then, take off the container and put the
commodity into the container and then place the packed goods on the pan again, now, the LCD will
display the net weight. Remove the merchandise and press this key, the scale will return to normal
weighting state.
Press this key and hold it for 1.5 seconds to enter into the unit switch function. Press the key
“ ”to shift the unit and press the key “ ” to confirm or exit the setting status.
: Press this key and hold it for 1.5 seconds to soft turn off the scale.
There is stable mark on the display
screen. When the weight is stable, the
triangle indicator will light which means it
is in the normal weighing status, at this
time you can put commodity on the platter
to sell.
RS232 port
Power on
Power off
English version
For Mexico
Power port
12
10. WARNING
Avoid overloading.
Do not operate the printer in a humid environment.
Do not operate the scale under the place of flammability and explosive.
11. SOFTWARE OPERATION
Double click , and then below interface will pop up
1 Select the corresponding
serial interfacebaud rate9600
2Click this
button
Information
area
Weight display
area
13
12. USB VIRTUAL SERIAL PORT DRIVER INSTALLATION
If you purchased optional accessory USB line, you must install USB virtual serial
driver to realize the communication between OS2X and external equipments. If you
purchased D9 line, you can skip this chapter.
Open disk and run softwareVCPDriver_V1.1_Setup.exe:
ClickNext
14
ClickNext
ClickFinish
15
13. COMMUNICATION PROTOCOL
Send communication protocol actively
Default send 10 times/s when power on. Frequency can be adjusted and the adjusting method is
same with OP box.
sending content is as follows
Head1
Head2
Flag1
Sign
Weight
Unit
CheckSum
Tail1
Tail2
Flag2
0
1
2
3
4~9
10,11
12
13
14
15
Head11 bytefixed as 0x01.
Head21 bytefixed as0x02.
Flag11 bytestatus F’: Weight is beyond the range or havent startup to zero.
S’: Weight is stable.
U’: Weight is unstable.
Sign1 bytesign ‘-’Weight is negative.
’: Weight is positive.
Weight6 bytesweight
Unit2 bytesunit
CheckSum: 12 bytes in front of the vision exclusive or and.
Tail11 bytefixed as 0x03.
Tail21 bytefixed as 0x04.
Flag21 bytestatus
Bit41 The current weight is zero. 0The current weight is not zero.
Bit51 current in the tare mode 0 Not in tare mode.
Bit61 Weight is beyond the range or havent startup to zero. 0 Weight is in normal and has
startup to zero.
Send communication protocol passively
1>PC Request the connection firstly
PC Send one byte command 0x05 firstly.
command
0x05
Scale response one byte command 0x06.
PC can confirm the scale has connected via these two commands firstly.
comman
d
0x06
2>PC Request to receive the weighing result.
PC sends one byte command 0x11.
command
0x11
scale response weighing resultresponse data format and the format of sending actively is basically the
same, just miss Flag2.
16
Head1
Head2
Flag1
Sign
Weight
Unit
CheckSum
Tail1
Tail2
0
1
2
3
4~9
10,11
12
13
14
Head11 bytefixed as 0x01.
Head21 byte, fixed as 0x02.
Flag11 bytestatus F’: Weight is beyond the range or havent startup to zero.
S’: Weight is stable.
U’: Weight is unstable.
Sign1 bytesign ‘-’Weight is negative.
’: Weight is positive.
Weight6 bytesweight
Unit2 bytesunit
CheckSum12 bytes in front of the vision exclusive or and.
Tail11 bytefixed as 0x03.
Tail21 bytefixed as 0x04.
tare zero by active or passive way
1. Tare or zero
PC sends
STX
Cmd
ETX1
ETX2
0
12
3
4
STX1 bytefixed as 0x3C.
Cmd2 bytes, tare fixed as 0x54, 0x4B.
zero fixed as 0x5A ,0x4B.
ETX11 bytefixed as 0x3E.
ETX21 bytefixed as 0x09.
Pinnacle scale DigitOpBox protocol
1Communication package format
1Communication package format
Awithout data columns formatnot including DATA and DT SUM
STX
ID
CMD
PARA
PGNO
LEN
SUM
0
1,2,3,4
5,6
7,8
9
10,11
12
SUM = Byte0 + Byte1 + Byte2 + + Byte10 + Byte11
Bwith data columns formatLEN > 0
STX
ID
CMD
PARA
PGNO
LEN
SUM
DATA
DT SUM
0
1,2,3,4
5,6
7,8
9
10,11
12
13 ~ (13+LEN-1)
(13+LEN ),
(14+LEN)
SUM = Byte0 + Byte1 + Byte2 + + Byte10 + Byte11
DT SUM = CRC16 ( Byte13 ~ Byte[13+LEN-1] )
Note:
1When LEN is 0, DATA column and DT SUM are empty, at this time, data Packet total
length is 13 bytes.
17
2When LRN is not 0, DT SUMs CRC checksum is only related with DATA column, and
is not related to the prior 13 bytes, at this time, data package total length is 13LEN2
byte.
3High order is in front and the low order is in rear to multi-byte column.
2 Communication package format explanation
3 .communication command
CMD1
CMD2
PARA1
PARA2
EXPLANATION
0x80
0x00
Baud Rate
0x00
Set communication baud rate
0x80
0x01
Frq
0x00
set measuring result sending frequency
0x80
0x02
0x00
0x00
read measuring result
0x80
0x03
0x00
0x00
start zero device
0x80
0x04
0x00
0x00
start tare device
0x80
0x05
Tare
start or stop preset tare device
0x80
0x06
Unit
0x00
set measuring unit
0x80
0x0d
0x00
0x00
The response of OP boxCommand failure
0x80
0x0e
0x00
0x00
The response of OP boxCommand success
2Command explanation:
4 Set communication baud rate:( Successful response 0x800EFailure response 0x800D
STX
ID
CMD
PARA
PGNO
LEN
SUM
0xAB
0x00000000
0x8000
0xXX00
0
0x00
X
Default the baud rate is 9600bps when power on. When the command is received successfully, change
baud rate by parameter PARA1.
XX = 0x01 : 115200 bps
XX = 0x02 : 57600 bps
XX = 0x03 : 38400 bps
XX = 0x06 : 19200 bps
XX = 0x0C : 9600 bps
Command use methodPC use the default baud rate 9600bps to send this command to OP box firstly, and
then continue to use 9600bps baud rate to response after OP box received the command. Then switch the
S/N
items
explanation
lengthbytes
mark
1
STX
Package head
1
Communications packet starting marks 0xAB
2
ID
Scale number
4
keepfill all with 0
3
CMD
command
2
Command classification
4
PARA
parameter
2
Parameter related with command
5
PGNO
Package
number
1
Data package numbersingle/last one fill with0
6
LEN
length
2
data length
7
SUM
checksum
1
The sum form item1to item6, total 12 bytes
8
DATA
data
LEN
Command dataMax 49 bytes
9
DT
SUM
Data
checksum
2
CRC checksum of 8
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Pinnacle Technology OS2CX User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI