4 Operation (for BUS and video alarm controllers)
Warning:
Content of this chapter is keyboard operation of BUS alarm controller (ARC9016C)
and video alarm controller (ARC5408C, ARC5808C).
4.1 Select Model and 485 Address
Warning:
The device supports hot swap function. When the controller operates as normal,
connect keyboard wiring end to port at keyboard bottom, the COM indicator flashes
saying the function is normal.
Note:
When you first connect to controller, you need to select language and controller model,
you can use it once being successfully registered to controller.
Step 1. Separately connect two ends of wire to keyboard port and power port on alarm
controller.
Step 2. Press key, meantime insert one end of wire into keyboard port.
Keyboard interface is ON and shoes language option.
Step 3. By pressing or key, select appropriate language, press
button. Enter alarm controller model selection page.
Step 4. By pressing or , select “6-485 Addr”, press key.
Enter keyboard address, and press key.
It returns to model selection and address setup page.
Note:
485 address is shown in decimal system, range is 00-15.
485 address cannot be repeated when connecting to more than one
keyboards.
Step 5. By pressing or key, select corresponding product model,
click button. The keyboard generate a sound, shows homepage and COM
indicator flashes, means auto registration is successful. Keyboard and alarm
controller can have communication.