ML Accessories OS001 User manual

Type
User manual

This manual is also suitable for

ML Accessories OS001B is a sensor that can be used with lights to detect motion and turn them on or off automatically. Here is some information that can help you to get the most out of your new sensor:

  • The OS001B has a built-in photosensor that allows you to set the light level at which the sensor will turn on.

  • Adjustable timer lets you set the amount of time that the lights will stay on after motion is detected.

  • The sensor has a detection range of up to 6 meters and a 120-degree detection angle.

  • The sensor can be mounted on a wall or ceiling, and it can be used indoors or outdoors.

ML Accessories OS001B is a sensor that can be used with lights to detect motion and turn them on or off automatically. Here is some information that can help you to get the most out of your new sensor:

  • The OS001B has a built-in photosensor that allows you to set the light level at which the sensor will turn on.

  • Adjustable timer lets you set the amount of time that the lights will stay on after motion is detected.

  • The sensor has a detection range of up to 6 meters and a 120-degree detection angle.

  • The sensor can be mounted on a wall or ceiling, and it can be used indoors or outdoors.

1
85
INSTALLATION & MAINTENANCE MANUAL
OS001 series
230V
50Hz
IP
55
2
These instructions should be read carefully and retained after installation by the end user for
future reference and maintenance.
These instructions should be used to aid installation of the following products:
OS001 / OS001B
GENERAL INSTRUCTIONS
SAFETY
INSTALLATION
Installation of this product should only be carried out by a qualified electrician or competent
person to the latest Building and current IEE Wiring Regulations (BS7671)
• Please isolate mains prior to installation/maintenance
Check the total load on the circuit (including when this product and load is fitted) does not
exceed the rating of the circuit cable, fuse or circuit breaker
Please note the IP (Ingress of Protection) rating of this product when deciding the location for
installation
• This unit is rated at IP55
• This product is Class II double insulated
• This product can be connected to slave units – product code OS003
Note: Avoid mounting this product in direct sunlight and close to luminaires as this will cause
sensing issues
• Provide power to the required point of installation
Horizontal and vertical surface mounting:
Using a slotted screwdriver, push on the base release tabs and pull the sensor away from the
base (see Fig 1)
Fig 1
OS001 series
These instructions should be read carefully and retained after installation by the end user for future reference and
maintenance.
These instructions should be used to aid installation of the following products:
OS001 / OS001B
SAFETY
Installation of this product should only be carried out by a qualified electrician or competent person to the
latest Building and current IEE Wiring Regulations (BS7671)
Please isolate mains prior to installation/maintenance
Check the total load on the circuit (including when this product and load is fitted) does not exceed the rating
of the circuit cable, fuse or circuit breaker
Please note the IP (Ingress of Protection) rating of this product when deciding the location for installation
This unit is rated at IP55
This product is Class I and requires an earth
INSTALLATION
Note: Avoid mounting this product: on non-stable surfaces; pointing directly at sunlight or bright surfaces or
near lamps or air vents
Provide power to the required point of installation
HORIZONTAL AND VERTICAL SURFACE MOUNTING
Using a slotted screwdriver, push on the base release tabs and pull the sensor away from the base (see Fig 1)
Fig 1
Using the base as a template, secure the base to the desired surface using the fixings supplied ensuring not to
infringe with any gas/water pipes or electrical cables (see Fig 2)
Fig 2
Ensuring correct polarity is observed, carefully wire as shown in Fig 3
3
• Ensuring correct polarity is observed, carefully wire as shown in Fig 3
Note: earth point is for continuity only and is non functional
• Push the sensor head back onto the base until secured into position (see Fig 4)
• Switch on power supply and check for correct operation
Fig 2
OS001 series
These instructions should be read carefully and retained after installation by the end user for future reference and
maintenance.
These instructions should be used to aid installation of the following products:
OS001 / OS001B
SAFETY
Installation of this product should only be carried out by a qualified electrician or competent person to the
latest Building and current IEE Wiring Regulations (BS7671)
Please isolate mains prior to installation/maintenance
Check the total load on the circuit (including when this product and load is fitted) does not exceed the rating
of the circuit cable, fuse or circuit breaker
Please note the IP (Ingress of Protection) rating of this product when deciding the location for installation
This unit is rated at IP55
This product is Class I and requires an earth
INSTALLATION
Note: Avoid mounting this product: on non-stable surfaces; pointing directly at sunlight or bright surfaces or
near lamps or air vents
Provide power to the required point of installation
HORIZONTAL AND VERTICAL SURFACE MOUNTING
Using a slotted screwdriver, push on the base release tabs and pull the sensor away from the base (see Fig 1)
Fig 1
Using the base as a template, secure the base to the desired surface using the fixings supplied ensuring not to
infringe with any gas/water pipes or electrical cables (see Fig 2)
Fig 2
Ensuring correct polarity is observed, carefully wire as shown in Fig 3
Using the base as a template, secure the base to the desired surface using the fixings supplied
ensuring not to infringe with any gas/water pipes or electrical cables (see Fig 2)
OS001 series
These instructions should be read carefully and retained after installation by the end user for future reference and
maintenance.
These instructions should be used to aid installation of the following products:
OS001 / OS001B
SAFETY
Installation of this product should only be carried out by a qualified electrician or competent person to the
latest Building and current IEE Wiring Regulations (BS7671)
Please isolate mains prior to installation/maintenance
Check the total load on the circuit (including when this product and load is fitted) does not exceed the rating
of the circuit cable, fuse or circuit breaker
Please note the IP (Ingress of Protection) rating of this product when deciding the location for installation
This unit is rated at IP55
This product is Class I and requires an earth
INSTALLATION
Note: Avoid mounting this product: on non-stable surfaces; pointing directly at sunlight or bright surfaces or
near lamps or air vents
Provide power to the required point of installation
HORIZONTAL AND VERTICAL SURFACE MOUNTING
Using a slotted screwdriver, push on the base release tabs and pull the sensor away from the base (see Fig 1)
Fig 1
Using the base as a template, secure the base to the desired surface using the fixings supplied ensuring not to
infringe with any gas/water pipes or electrical cables (see Fig 2)
Fig 2
Ensuring correct polarity is observed, carefully wire as shown in Fig 3
Fig 3
Push the sensor head back onto the base until secured into position (see Fig 4)
Fig 4
Switch on power supply and check for correct operation
INTERNAL OR EXTERNAL CORNER MOUNTING
This sensor can be corner-mounted by removing part of the base as shown (breakable areas) Screw the base
onto a suitable surface and insert the installation cables through the entry holes/grommets in the back of the
base and carefully wire as shown in Fig 3, ensuring the IP rating of the unit is maintained (silicone sealant may
need to be applied between the sensor and mounting surface) secure the sensor head onto the base (see Fig 5)
Fig 5
CEILING MOUNTING
For ceiling mounting follow instructions for horizontal/vertical mounting and angle head accordingly (see Fig 2)
BLANKING INSERTS
Blanking inserts are supplied that can be cut and attached to the lens to blank out areas of interference as
required i.e. heat sources, public pathways etc.
Fig 3
Fig 4
4
Internal or external corner mounting:
Note: sensor can be corner-mounted by removing part of the base as shown (breakable areas)
Screw the base onto a suitable surface and insert the installation cables through the entry holes/
grommets in the back of the base and carefully wire as shown in Fig 3, ensuring the IP rating of
the unit is maintained (silicone sealant may need to be applied between the sensor and mounting
surface)
• Secure the sensor head onto the base (see Fig 5)
Fig 3
Push the sensor head back onto the base until secured into position (see Fig 4)
Fig 4
Switch on power supply and check for correct operation
INTERNAL OR EXTERNAL CORNER MOUNTING
This sensor can be corner-mounted by removing part of the base as shown (breakable areas) Screw the base
onto a suitable surface and insert the installation cables through the entry holes/grommets in the back of the
base and carefully wire as shown in Fig 3, ensuring the IP rating of the unit is maintained (silicone sealant may
need to be applied between the sensor and mounting surface) secure the sensor head onto the base (see Fig 5)
Fig 5
CEILING MOUNTING
For ceiling mounting follow instructions for horizontal/vertical mounting and angle head accordingly (see Fig 2)
BLANKING INSERTS
Blanking inserts are supplied that can be cut and attached to the lens to blank out areas of interference as
required i.e. heat sources, public pathways etc.
Fig 3
Push the sensor head back onto the base until secured into position (see Fig 4)
Fig 4
Switch on power supply and check for correct operation
INTERNAL OR EXTERNAL CORNER MOUNTING
This sensor can be corner-mounted by removing part of the base as shown (breakable areas) Screw the base
onto a suitable surface and insert the installation cables through the entry holes/grommets in the back of the
base and carefully wire as shown in Fig 3, ensuring the IP rating of the unit is maintained (silicone sealant may
need to be applied between the sensor and mounting surface) secure the sensor head onto the base (see Fig 5)
Fig 5
CEILING MOUNTING
For ceiling mounting follow instructions for horizontal/vertical mounting and angle head accordingly (see Fig 2)
BLANKING INSERTS
Blanking inserts are supplied that can be cut and attached to the lens to blank out areas of interference as
required i.e. heat sources, public pathways etc.
Fig 5
Ceiling mounting:
For ceiling mounting follow instructions for horizontal/vertical mounting (see Fig 2) and angle
head accordingly
5
Blanking inserts are supplied that can be cut and attached to the lens to blank out areas of
interference as required i.e. heat sources, public pathways etc.
For initial setup of the sensor, turn the time control fully anti-clockwise to the minimum position
and the lux control fully clockwise to the maximum position
After the sensor has been switched on it will take up to 30 seconds to enter into automatic mode
Once in automatic mode, walk test the PIR by moving in front of the sensor at various positions of
the required field of view, checking that the luminaire is activated at each point
After the initial setup and walk test have been completed, adjust the time and lux setting to the
desired levels
TEST MODE
For initial setup of the sensor, turn the time control fully anti-clockwise to the minimum position and the lux control fully
clockwise to the maximum position
After the sensor has been switched on it will take up to 30 seconds to enter into automatic mode
Once in automatic mode, walk test the PIR by moving in front of the sensor at various positions of the required field of
view, checking that the luminaire is activated at each point
After the initial setup and walk test have been completed, adjust the time and lux setting to the desired levels
SENSOR SETUP
Note: When making adjustments to the PIR settings ensure the sensor is powered down
Time control: 3 seconds 30 minutes. Turn the dial clockwise to increase the length of time the luminaire will remain on
Lux control: 5 lux full daylight. This setting will adjust the ambient light level the sensor will operate at. If you require the
luminaire to operate in brighter conditions turn the dial clockwise (see Fig 6)
Fig 6
LOADING
Do not exceed the maximum loading requirements as listed below:
Incandescent 1800W
Fluorescent 1100W
LED 200W
MANUAL OVERRIDE
When in auto mode the product will operate to the settings of the lux and time controls
The unit can be manually overridden by switching the power off and on twice within 3 seconds, this will turn the luminaire
on permanently. After 6 hours the unit will revert back to auto mode or the unit can be put back into auto mode at any
time by switching the power off and on once
WARNING
This product must be disconnected from the circuit if subjected to any high voltage or insulation resistance testing.
Irreparable damage will occur if this instruction is not followed
GENERAL
The product should be recycled in the correct manner when it reaches the end of its life. Check local authorities for where
facilities exist. Clean with a soft dry cloth only, do not use other materials or solutions which may damage the product
WARRANTY
This product has a warranty of 1 year from date of purchase. Failure to install in accordance with the current edition of the
IEE Wiring Regulations, improper use, or removal of the batch codes will invalidate the warranty. If this product should fail
BLANKING INSERTS
TEST MODE
6
TEST MODE
For initial setup of the sensor, turn the time control fully anti-clockwise to the minimum position and the lux control fully
clockwise to the maximum position
After the sensor has been switched on it will take up to 30 seconds to enter into automatic mode
Once in automatic mode, walk test the PIR by moving in front of the sensor at various positions of the required field of
view, checking that the luminaire is activated at each point
After the initial setup and walk test have been completed, adjust the time and lux setting to the desired levels
SENSOR SETUP
Note: When making adjustments to the PIR settings ensure the sensor is powered down
Time control: 3 seconds 30 minutes. Turn the dial clockwise to increase the length of time the luminaire will remain on
Lux control: 5 lux full daylight. This setting will adjust the ambient light level the sensor will operate at. If you require the
luminaire to operate in brighter conditions turn the dial clockwise (see Fig 6)
Fig 6
LOADING
Do not exceed the maximum loading requirements as listed below:
Incandescent 1800W
Fluorescent 1100W
LED 200W
MANUAL OVERRIDE
When in auto mode the product will operate to the settings of the lux and time controls
The unit can be manually overridden by switching the power off and on twice within 3 seconds, this will turn the luminaire
on permanently. After 6 hours the unit will revert back to auto mode or the unit can be put back into auto mode at any
time by switching the power off and on once
WARNING
This product must be disconnected from the circuit if subjected to any high voltage or insulation resistance testing.
Irreparable damage will occur if this instruction is not followed
GENERAL
The product should be recycled in the correct manner when it reaches the end of its life. Check local authorities for where
facilities exist. Clean with a soft dry cloth only, do not use other materials or solutions which may damage the product
WARRANTY
This product has a warranty of 1 year from date of purchase. Failure to install in accordance with the current edition of the
IEE Wiring Regulations, improper use, or removal of the batch codes will invalidate the warranty. If this product should fail
Note: When making adjustments to the PIR settings ensure the sensor is powered down
Time control: 3 seconds – 30 minutes. Turn the dial clockwise to increase the length of time the
luminaire will remain on
Lux control: 2 lux – full daylight. This setting will adjust the ambient light level the sensor will
operate at. If you require the luminaire to operate in brighter conditions turn the dial clockwise
(see Fig 6)
Do not exceed the maximum load requirements as listed below:
Incandescent - 2000W
Fluorescent - 1000W
LED - 225W
When in auto mode the product will operate to the settings of the lux and time controls
The unit can be manually overridden by switching the power off and on twice within 3 seconds, this
will turn the luminaire on permanently. After 6 hours the unit will revert back to auto mode or the
unit can be put back into auto mode at any time by switching the power off and on once
This product must be disconnected from the circuit if subjected to any high voltage or insulation
resistance testing. Irreparable damage will occur if this instruction is not followed
SENSOR SETUP
LOAD
MANUAL OVERRIDE
WARNING
Fig 6
7
The product should be recycled in the correct manner when it reaches the end of its life. Check local
authorities for where facilities exist. Clean with a soft dry cloth only, do not use other materials or
solutions which may damage the product
This product has a warranty of 1 year from date of purchase. Failure to install in accordance with
the current edition of the IEE Wiring Regulations, improper use, or removal of the batch codes
will invalidate the warranty. If this product should fail within its warranty period it should be
returned to the place of purchase for a free of charge replacement. ML Accessories does not accept
responsibility for any installation costs associated with the replacement product. Your statutory
rights are not affected. ML Accessories reserve the right to alter product specification without prior
notice
GENERAL
WARRANTY
8
ML Accessories Limited
LU5 5TA
www.mlaccessories.co.uk AKJUN18_V2
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

ML Accessories OS001 User manual

Type
User manual
This manual is also suitable for

ML Accessories OS001B is a sensor that can be used with lights to detect motion and turn them on or off automatically. Here is some information that can help you to get the most out of your new sensor:

  • The OS001B has a built-in photosensor that allows you to set the light level at which the sensor will turn on.

  • Adjustable timer lets you set the amount of time that the lights will stay on after motion is detected.

  • The sensor has a detection range of up to 6 meters and a 120-degree detection angle.

  • The sensor can be mounted on a wall or ceiling, and it can be used indoors or outdoors.