  • Hello! I've reviewed the datasheet for the SCE-TSH25, SCE-TSH50, SCE-TSH75, SCE-TSH100 and SCE-TSH150 Touch Safe Heaters. This document provides detailed information on model selection based on enclosure surface area, installation guidelines including safety gaps, and the maximum surface temperature for the heaters. I'm ready to answer any questions you have about these heaters.
  • What is the maximum surface temperature of the heater?
    What is the minimum thermal safety gap required?
    Where should the heater be installed in the enclosure?
FT2 AREA TSH-25 TSH-50 TSH-75 TSH-100 TSH-150
0 – 8 One
9 – 16 One
17 – 24 One
25 – 32 One
33 – 40 One
41 – 48 One
49 – 56 One
57 – 64 One
65 – 72 One
73 – 80 One
81 – 88 One
89 – 120 One
1.61”
1.61”
4.92”
5.51”
2.48”
2.76”
8.66”
2.76”
2.76”
MODEL SELECTION:
• Determine the surface area of the enclosure in square feet.
• Select the Touch Safe Heater unit from
the chart based on square feet of the enclosure.
• Units should be installed in the lower quarter of the enclosure.
• When enclosure width is greater than height, two smaller
units will heat the area more efficiently than one larger unit.
SURFACE AREA EQUATION:
2[(Height x Width)+(Height x Depth)+(Width x Depth)] ÷ 144
HEATER ELEMENT
SUPPLY
CONNECTOR N L
2 1
BK
AWG18
RD
AWG18
• All heaters are delivered with a DIN rail Clip 1.37”.
• Maximum Surface Temperature on casting: 80C/176F.
• 4.75” Minimum Thermal Safety gap required
above or to side of this device.
Touch Safe Heaters
SCE-TSH25 & SCE-TSH50
SCE-TSH75 & SCE-TSH100
SCE-TSH150
CIRCUIT DIAGRAM
NOTES
/