1. Using appropriate screws(by others), secure mounting plate to J-box(by others). Ensure gasket is smooth and compressed. Use
additional screws and bracing around J-box if necessary.
2. Hook ballast box plate to mounting plate bottom and carefully allow fixture to hang.
3. Attach wires and ensure all connections are properly matched.
4. Hide splice in J-box and push entire fixture up, covering the mounting plate. Secure fixture in place with #6-32 x1/2" pan head set
screw.
Outdoor J-box
(by others)
Gasket
Mounting plate
Fixture assembly
#6-32 x5/8"
Socket cap screw
(x2)
#6-32 x1/2"
Socket cap screw
Ballast box
mounting plate
#6-32 x1/2" Pan head
set screw
Mounting the fixtures
Yoke 03
Warning
: Before starting any work ensure
that all sources of power are turned off. All
work must meet local/national codes and be
performed by a certified electrician.
Installation Instructions
Vault
C-Scroll
Roundel
These installation instructions valid with the above Ametrix styles.
ADY071457 REV A(ECN070306)
Sheet 1 of 3
Large, OUTDOOR
YIxx
(Yoke mount, Integral ballast)
Visor and Non-Visor
Available yoke styles
Yoke 04Yoke 01
Yoke 02
96.71
13
"
16
3
3
1
2
"
89.03
3
1
2
"
88.90
(Dimensions valid for 16 1/2 [419] fixture head size)
3
281.43
32
11 "
"
32
5
22
562.86
33.03
5
"
16
32
52.83
"
32
6.83
"
127
5"
2
9
3
193.24
"7
32
19
1
6
1
4
"
158.75
(Dimensions valid for 22 1/2 [571.5], 30 1/2 [774.7] fixture head sizes)
9
25.40
2
1"
193.20
"
127
5"
7
32
19
410.46
"
12"
32
(x6)
5
16
304.80
33.03
5
"
16
3
52.83
"
32
"
32
6.83
1
8
3
32
"
205.23
Installation Instructions
Vault w/ visor
C-Scroll w/ visor
Roundel w/ visor
These installation instructions are valid with the above Ametrix styles
Mounting Plate Dimensions In [mm]
Warning
: Before starting any work ensure
that all sources of power are turned off. All
work must meet local/national codes and be
performed by a certified electrician.
Do not
mount fixtures vertically.
Large, OUTDOOR
YIxx
(Yoke mount, Integral ballast)
Visor and Non-Visor
Sheet 2 of 3
ADY071457 REV A(ECN070306)
Installation Instructions
Vault w/ visor
C-Scroll w/ visor
Roundel w/ visor
These installation instructions are valid with the above Ametrix styles
Lamping Size Chart
(lamps provided by others)
Warning
: Before starting any work ensure
that all sources of power are turned off. All
work must meet local/national codes and be
performed by a certified electrician.
Do not
mount fixtures vertically.
Large, OUTDOOR
YIxx
(Yoke mount, Integral ballast)
Visor and Non-Visor
Sheet 3 of 3
ADY071454 REV A(ECN070306)
FIXTURE SIZE
(inches/ mm) WATTAGE
# OF
LAMPS LAMP TYPE LAMP DESCRIPTION
Lamp
(not to scale)
16
1/2
/ 419.1 32 W 1 T4 Compact Flourescent
16
1/2
/ 419.1 42 W 1 T4 Compact Flourescent
16
1/2
/ 419.1 57 W 1 T4 Compact Flourescent
16
1/2
/ 419.1 100 W 1 ED17 Ceramic Metal Halide
16
1/2
/ 419.1 150 W 1 T6 Ceramic Metal Halide
16
1/2
/ 419.1 175 W 1 ED17 Ceramic Metal Halide
22
1/2
/571.5 mm 250 W 1 ET18 Metal Halide
22
1/2
/571.5 mm 400 W 1 ET18 Metal Halide
22
1/2
/571.5 mm 150 W 2 T6 Ceramic Metal Halide
22
1/2
/571.5 mm 32 W 2 T4 Compact Flourescent
22
1/2
/571.5 mm 42 W 2 T4 Compact Flourescent
22
1/2
/571.5 mm 250 W 1 ET18 Metal Halide
22
1/2
/571.5 mm 400 W 1 ET18 Metal Halide
22
1/2
/571.5 mm 150 W 2 T6 Ceramic Metal Halide
22
1/2
/571.5 mm 350 W 1 T3 Halogen(Double Ended)
22
1/2
/571.5 mm 500 W 1 T3 Halogen(Double Ended)
30
1/2
/ 774.7 36 W 1 T5 Twin Tube
30
1/2
/ 774.7 40 W 1 T5 Twin Tube
30
1/2
/ 774.7 50 W 1 T5 Twin Tube
30
1/2
/ 774.7 55 W 1 T5 Twin Tube
30
1/2
/ 774.7 36 W 2 T5 Twin Tube
30
1/2
/ 774.7 40 W 2 T5 Twin Tube
30
1/2
/ 774.7 50 W 2 T5 Twin Tube
30
1/2
/ 774.7 55 W 2 T5 Twin Tube
30
1/2
/ 774.7 250 W 2 ET18 Metal Halide
30
1/2
/ 774.7 400 W 2 ET18 Metal Halide
30
1/2
/ 774.7 900 W 1 T3 Halogen(Double Ended)
30
1/2
/ 774.7 1000 W 1 T3 Halogen(Double Ended)