Typical Characteristics
Specifications
Cell Type KR-DHL
Dimensions
of
Bare Cell
H
58.4
±0.4
mm
2.299
±0.016
inch
D
32.3
±0.3
mm
1.272
±0.012
inch
d
8.5 mm
0.335 inch
D
d
H
Nominal Capacity 4000mAh
Nominal Voltage 1.2V
Charging Current
Trickle 133mA
Standard 400mA
Charging Time
Trickle above 48Hrs.
Standard 14 to 16Hrs.
Ambient
Temperature
Charge 0°C to +70°C [+32°F to 158°F]
Discharge -20°C to +70°C [ -4°F to 158°F]
Storage -30°C to +70°C [ -22°F to 158°F]
Internal Impedance (Av.)
(at 50% discharge)
4.2m
Ω
(at 1000Hz)
Weight 145g/5.11oz
Dimensions(D)
×
(H)
(with tube)
Charge
1.6
1.5
1.4
1.3
0 6 12 18 24 30 36 42 48
Charge : 133mA
0˚C/32˚F
20˚C/68˚F
40˚C/104˚F
60˚C/140˚F
Cell Voltage (V)
Charge Time (Hrs.)
Charge
1.6
1.5
1.4
1.3
0246810121416
Charge : 400mA
0˚C/32˚F
20˚C/68˚F
40˚C/104˚F
60˚C/140˚F
Cell Voltage (V)
Charge Time (Hrs.)
Discharge
(at low rate)
1.4
1.2
1.0
0.8
0246810121416
Charge : 400mA×16Hrs.
at 20˚C/68˚F
(0.1 It)(0.2 It)(0.5 It)
Cell Voltage (V)
Discharge Time (Hrs.)
Discharge
(at high rate)
1.4
1.2
1.0
0.8
0 1020304050607080
Charge : 400mA×16Hrs.
at 20˚C/68˚F
(2 It)
(1 It)
Cell Voltage (V)
Discharge Time (Mins)
Discharge
Trickle charge (at high temperature)
1.4
1.2
1.0
0.8
0 1020304050607080
Charge : 133mA×48Hrs.
Charge : 133mA×24Hrs.
Discharge : 4000mA
at 45˚C/113˚F
Cell Voltage (V)
Discharge Time (Mins)
Temperature
(Charge & Discharge)
100
80
60
40
-20 70˚C
-4
-10
14
0
32
10
50
20
68
30
86
40
104
50
122
60
140 158˚F
Available Capacity (%)
Operating Temperature
90
70
50
Charge Characteristics
Discharge Characteristics
Condition Charge : 133mA×48Hrs.
Discharge : 800mA
(End Volt 1.0V)
33.2
0
×
59.5
0
mm
-0.9 -1.5
1.31
0
×
2.34
0
inch
-0.04 -0.06
CD010830