inVENTer GS62 Installation And Operating Instructions Manual

Type
Installation And Operating Instructions Manual
Installation and Operating Instructions 09/2013
GS62 Air Extractor System
GS62 Air Extraction System Installation and Operating Instructions 09/2013
2
LEGAL NOTICES
WARNING CONCEPT
These instructions contain information for your personal safety and to prevent material damage. Information for your
personal safety is denoted by a warning triangle. Information pertaining to material damage only has no warning
triangle. The warnings are grouped according to these levels of risk:
DANGER indicates that death or serious injury will result if proper precautions are not taken.
WARNING indicates that death or serious injury can result if proper precautions are not taken.
CAUTION with warning triangle denotes that minor injury can result if proper precautions are not
taken.
CAUTION
without warning triangle denotes that material damage can result if proper precautions
are not taken.
BEWARE denotes that an undesirable event or state can result if the relevant advisory is not heeded.
Should there be more than one level of risk, the warning for the highest level of risk is always used. A warning about
personal injury with a warning triangle may also include a warning about material damage.
NOTE denotes further, useful information.
QUALIFIED PERSONNEL
The unit/system may only be installed and operated in conjunction with this documentation. Installation, electrical
connection and initial startup of the unit/system may only be performed by qualified personnel. Qualified personnel
within the context of safety-related information in this documentation are those authorized to install, start up and
identify equipment, systems and electrical circuits in accordance with safety engineering standards.
INTENDED USE > WARNING
When installing the equipment/system, observe the applicable building codes, fire protection
regulations and accident prevention regulations of the Employer's Liability Insurance Association. Only
use the equipment/system as intended for the applications described in this documentation and only
in conjunction with the components recommended, approved and specified in this documentation
by Öko-Haustechnik inVENTer GmbH. Changes and modifications to the equipment/system are not
permitted. Trouble free and safe operation of the equipment/ system requires proper transportation,
proper storage and assembly, as well as careful operation and maintenance. This documentation is
part of the equipment/system and must be accessible at all times. Observe all safety regulations in
this documentation.
TRADEMARKS
inVENTer® is a registered trademark of ÖkoHaustechnik inVENTer GmbH. Other names used in this documentation
may be trademarks whose use by third parties may infringe upon the rights of the owner.
EXEMPTION FROM LIABILITY
The content of this documentation has been reviewed for compliance with the hardware and software described.
However, discrepancies cannot be ruled out and so liability cannot be assumed for full compliance. This
documentation is updated regularly. Necessary corrections and appropriate additions are always included in
subsequent versions.
As of: 07/2013
13 GS62 Air Extraction System Installation and Operating Instructions 09/2013
3
TABLE OF CONTENTS
1 System overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
2 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
2.1 Features ..................................................................................................................7
2.2 Assembly ................................................................................................................7
3 Operating conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
3.1 Telescopic tube .......................................................................................................8
3.2 Flat duct (GS62-Corner) .........................................................................................8
4 Functional elements / interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
4.1 GS61 PSU ..............................................................................................................9
5 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
5.1 Installation preparation ...........................................................................................9
5.2 PSU .......................................................................................................................10
5.3 Telescopic tube ....................................................................................................10
5.4 Fitting the telescopic tube into the wall ................................................................12
5.5 Protective hood.....................................................................................................13
5.6 Nonreturn valve .....................................................................................................14
5.7 Fan housing ..........................................................................................................14
5.8 Inner baffle ............................................................................................................16
5.9 Flat duct (GS62-Corner) .......................................................................................17
5.10 Dimensional drawings...........................................................................................18
5.10.1 GS62 with protective hood ...................................................................................18
5.10.2 GS62 with GS62-Corner .......................................................................................20
6 Electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
7 Technical details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
7.1 GS62 air extraction system ..................................................................................24
7.2 GS61 PSU ............................................................................................................25
7.3 Fan ........................................................................................................................25
7.4 Telescopic tube .....................................................................................................25
7.5 Inner baffle ............................................................................................................26
7.6 Protective hood.....................................................................................................26
7.7 Flat duct ................................................................................................................26
7.8 Grate with sleeve ..................................................................................................26
7.9 Fan housing ..........................................................................................................26
7.10 Nonreturn valve .....................................................................................................26
8 Deliverables, accessories and spare parts . . . . . . . . . . . . . . . . . . . . . . . . . . .27
8.1 Deliverables ..........................................................................................................27
8.2 Accessories ..........................................................................................................27
8.3 Spare parts ...........................................................................................................27
4
GS62 Air Extraction System Installation and Operating Instructions 09/2013
TABLE OF CONTENTS
9 Maintenance and repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
10 Troubleshooting and disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
10.1 Troubleshooting .......................................................................................................... 29
10.1.1 GS62 air extraction system ........................................................................................ 29
10.1.2 Functional modules .................................................................................................... 29
10.2 Disposal ...................................................................................................................... 29
11 Warranty and service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
11.1 Terms of warranty ....................................................................................................... 30
11.2 Service ........................................................................................................................ 30
Legal notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
5
13 GS62 Air Extraction System Installation and Operating Instructions 09/2013
SYSTEM OVERVIEW
3
2
1
1 SYSTEM OVERVIEW
The GS62 was developed for the ventilation of rooms with outside windows in single and multiple occupancy
houses, hotels and guest houses. It is an air extraction system that works without heat recovery and with direct
current.
Application areas
The GS62 is fitted into the outside wall of a building and can be used for:
• Bathrooms / toilets
• Kitchens
• Utility rooms
• Hallways
Variants
The base element of every variant is the combination of wall mounting sleeve (1), fan housing (2) with integrated
fan (3) and the GS61 PSU.
GS62 base element GS61 PSU
The GS62 can optionally be connected to the following modules, offering extended functionality as compared
to a standard On/Off switch*
)
:
• R60 controller
• Delay switch
• Hygrostat
Note - The description and connection options of these modules are in additional,
accompanying installation and operating instructions for the GS61 air extraction system.
Interior room side
The ventilation system is covered by a baffle on the interior wall side. Inside baffles can be
ordered:
in colors white/silver/stainless/gold (material: is plastic, curved shape)
in opaque glass (straight shape)
as a frame for affixing a glass or ceramic tile (material: plastic, straight shape)
*) The On/Off switch is not included in the delivery
6
GS62 Air Extraction System Installation and Operating Instructions 09/2013
SYSTEM OVERVIEW
COMPONENT DESCRIPTION FEATURES ORDER NO.
GS62 - - 1001-0120
GS62-Corner 500 Comprising flat duct (500mm), 2 x wall
brackets and moffit grate
White 1506-0060
GS62-Corner 1000 Comprising flat duct (1000mm), 2 x wall
brackets and moffit grate
White 1506-0061
2-part telescopic tube Extension (500mm) for standard telescopic tube - 1002-0021
GS62 protective hood High-grade steel, powder-coated
White (RAL 9016) 1508-0043
Gray (RAL 7011) 1508-0044
High-grade steel, sanded Bare*
)
1508-0046
Inside baffle Plastic (curved) White 1505-0020
Stainless 1505-0021
Gold**
)
1505-0024
Silver **
)
1505-0025
Glass Opaque 1505-0022
Frame Decor of tile 1505-0023
R60 controller Fan speed regulator 1002-0006
Delay timer Button with integrated delay controller 1002-0011
Hygrostat Supports regulation of relative humidity 1002-0015
GS62 WITH PROTECTIVE HOOD GS62 WITH GS62-CORNER
Exterior room side
In the direction of the exterior room side, the ventilation system can be closed either with a
• protective hood (white/gray/bare
1)
) or
• the GS62-Corner 500 / GS62-Corner 1000, depending on preference and practical requirements
The GS62-Corner is used mainly when a building is retrofitted with insulation as part of renovation measures.
The air duct is embedded in the insulation and the airflow is directed out in the window reveal. The wall opening
for the ventilation system must therefore be in close proximity to the window. The GS62-Corner 500 is used
for a 250 … 450mm distance, the GS62-Corner 1000 for a 451 .. 950mm distance, between wall opening and
window reveal.
Validity
The installation and operating instructions apply for these elements:
*) Install only after coating (by customer) with Nano Set ,included
**) Not stock items (lead time on request)
7
13 GS62 Air Extraction System Installation and Operating Instructions 09/2013
DESCRIPTION
4
9 8 7
6
5
321
13
12
10
11
8 7 6
5
4
321
11
10
9
4
9
8
6
5
3
2
1
13
12
10
11
8
7
6
5
4
3
2
1
11
10
9
2 DESCRIPTION
The GS62 air discharge system is used to expel old air from a room. The fan is preinstalled in the housing for
ex works deliveries.
2.1 Features
• Low power consumption of fan (approx. 70% less than comparable AC fans)
• Use for wall thicknesses of 150 ... 550mm, to 950mm with telescopic extension
• Hole for telescopic tube Ø 115mm
• Use for distance between wall opening and window reveal of 350 ... 950mm (GS62-Corner)
• Combination of the base element with six inside baffles of different designs, shapes and colors,
and with three protective hoods of different colors, or the GS62-Corner in white
2.2 Assembly
GS62 WITH PROTECTIVE HOOD GS2 WITH GS62-CORNER
Interior plaster Interior plaster
Fan housing Fan housing
Inside baffle Inside baffle
Fan Fan
Nonreturn valve Nonreturn valve
Telescopic tube, 2-part (sleeve with tube) Telescopic tube, 2-part (sleeve with tube)
Protective hood rear panel Window
Protective hood cover Grate
Exterior plaster Window ledge
Insulation Duct
Masonry Exterior plaster
Insulation
Masonry
Figure 1: GS62 assembly
1
1
2
2
4
4
3
3
5
5
6
6
7
7
8
8
99
1010
1111
12
13
8
GS62 Air Extraction System Installation and Operating Instructions 09/2013
OPERATING CONDITIONS
3 OPERATING CONDITIONS
Caution - Only use the GS62 in rooms that are free of aggressive and caustic gases, and
extreme dust exposure. This will ensure reliable functioning of the fan.
3.1 Telescopic tube
Standard variant
The length of the standard variant of the telescopic tube is 550mm, meaning it can be used for maximum wall
thicknesses of 550mm. For wall thicknesses of 325 ... 550mm, the telescopic tube is continuously adjustable.
The sleeve can be shortened by a maximum of 150mm for wall thicknesses shorter than 325mm.
Note - The minimum permitted wall thickness when using the standard variant of the telescopic
tube is 150mm.
The sleeve of the telescopic tube on the interior wall side is covered by the fan housing and an Inside baffle.
Extension
An extension is available as an option for walls having a thickness from 550mm to 1000mm (maximum). The
extension is a second telescopic tube without fan. The order number for the extension is under Validity in Sec-
tion System overview.
2-part telescopic tube (extension)
Fan housing
Inside baffle
Fan
Nonreturn valve
2-part telescopic tube (sleeve with tube)
Protective hood rear panel
Protective hood cover
Figure 2: GS62 assembly with two telescopic tubes (extension)
3.2 Flat duct (GS62-Corner)
The length of the flat duct (GS62-Corner 500) is 500mm, and so can be used for gaps between wall open-
ing and window reveal of 250 ... 450mm. If the gap between wall opening and window reveal is greater than
400mm, a flat duct 1000mm in length can be ordered as an option (GS62-Corner 1000).
Note - The maximum permitted gap between wall opening and window reveal is 950mm.
1
2
4
3
5
6
7
8
2-part telescopic tube (extension)
2-part telescopic tube (extension)
3
2-part telescopic tube (extension)
2-part telescopic tube (extension)
2
2-part telescopic tube (sleeve with tube)
2-part telescopic tube (sleeve with tube)
5
2-part telescopic tube (sleeve with tube) 2-part telescopic tube (sleeve with tube)
Nonreturn valve
Nonreturn valve
4
6
8
1
7
9
13 GS62 Air Extraction System Installation and Operating Instructions 09/2013
FUNCTIONAL ELEMENTS/INSTALLATION
4 FUNCTIONAL ELEMENTS / INTERFACES
4.1 GS61 PSU
Power supply (AC 230V, 50 Hz)
Fan connector (-)
Fan connector (+) or functional module (+)
Figure 3: Connectors on GS61 PSU
5 INSTALLATION
5.1 Installation preparation
Dimensions
Name Comprising: Length (mm) LxW / diameter (mm)
Hole for Wall thickness Ø 115
telescopic tube -
(with insulation, interior/exterior plaster)
Telescopic tube Sleeve 300 Ø 107
Tube 300 Ø 103
Extension Identical in design to combination Wall mounting sleeve / telescopic tube
Flat duct - 500 209x65
- 1000
Opening for - 87 Ø ≥ 75
wall mounting box
Wall mounting box - 87 Ø 73
Note - Keep a minimum distance of 100mm from the center of the wall mounting sleeve to
walls, to components in the interior area as well as to fixtures and fittings.
Wall holes and cable laying
Danger - Make the opening for the wall mounting box outside protective areas 0 to 2 of the
room. This will ensure that no moisture can penetrate in.
1. Make two holes in the masonry - one (Ø75) for the wall mounting box and one (Ø115) for the telescopic
tube. Ensure that the hole for the wall mounting sleeve of the GS62 is at an angle of 1-2° to the outside
wall so that condensation is drained away reliably.
2. Lay the 2-wire connecting lead (red/white) for the wall mounting box in the cable duct such that the cable
ends project out of each wall opening by at least 150mm. This ensures that the PSU and switch can be
connected with terminal blocks.
Note - The dimensional drawings for all holes are in Section Dimensional drawings.
1
1
2
2
10
GS62 Air Extraction System Installation and Operating Instructions 09/2013
INSTALLATION INSTALLATION
5
2
3
1
4
5.2 PSU
Danger - Before starting any work on electrical systems, disconnect all relevant equipment
from the power supply. When wiring the power supply, observe the requirements of Safety
Class II.
GS61 PSU
Cavity
PSU
Fan connector (terminal, 2-pin)
Wall mounting box
Cavity separating wall
Figure 4: Fitting the PSU
1. Make two holes on the wall mounting box (4) - these must be in different cavities (1).
2. Separately guide the cables for the PSU and the fan through one hole each and insert the wall mounting
box.
3. Connect the fan cable to the PSU (2) using the 2-pin terminal (3).
4. Ensure correct polarity connections are made. Information on this is in Section Electrical connection.
Note - The wall mounting box must always be shut.
GS61 PSU - Attach a standard or optionally available On/Off switch. Order number informa-
tion is in Section Deliverables and accessories.
5.3 Telescopic tube
GS62 with protective hood GS62 with GS62-Corner
Exterior plaster
Insulation
Masonry
Interior plaster
Figure 5: Determining the wall thickness
1
1
2
2
4
4
3
3
5
2
1
3
4
Interior plaster
Interior plaster
Interior plaster
Interior plaster
Interior plaster
Interior plaster
Interior plaster
Interior plaster
Exterior plaster
Exterior plaster
Exterior plaster
Exterior plaster
Insulation
Exterior plaster
Insulation
Exterior plaster
Insulation
Exterior plaster
Insulation
Insulation
Insulation
Insulation
Insulation
Interior plaster
Interior plaster
Interior plaster
Interior plaster
Interior plaster
Interior plaster
Interior plaster
Interior plaster
Interior plaster
Interior plaster
Interior plaster
Interior plaster
Interior plaster
Interior plaster
Interior plaster
Interior plaster
Interior plaster
Interior plaster
Insulation
Insulation
Insulation
Insulation
Insulation
Insulation
Insulation
Exterior plaster
Exterior plaster
Interior plaster
Exterior plaster
Insulation
Masonry
Interior plaster
Masonry
Masonry
Masonry
Masonry
Masonry
Masonry
Masonry
Insulation
Insulation
Masonry
Masonry
Insulation
Masonry
Masonry
Insulation
Exterior plaster
1
Exterior plaster
Exterior plaster
4
Exterior plaster
Exterior plaster
otective hood GS62 with GS62-Cor
11
13 GS62 Air Extraction System Installation and Operating Instructions 09/2013
INSTALLATION
GS62 with protective hood GS62 with GS62-Corner
1. Determine the exact wall thickness by 1. Determine the exact wall thickness by
adding the thicknesses of exterior plaster, insulation, adding the thicknesses of masonry and
masonry and interior plaster. interior plaster.
2. Add 5mm for the projection at the 2. Add 10mm for the projection at the
outside plaster edge. The projection is required for masonry. The projection is required for correct
correct installation of the protection hood. installation of the flat duct.
3. Shorten or extend the telescopic tube in line with the wall thickness determined. The following table shows
an overview of the exact procedure.
Standard telescopic tube 2 telescopic tubes (extension)
Wall thickness (mm) Wall thickness (mm)
150 ... 324 325 ... 550 551 ... 1000
Seal all the joints of the tube and sleeve with durable, watertight adhesive tape*
)
. This fuses together the
joints. When condensation forms in the telescopic tube, the sealed joints prevent
moisture from penetrating into the wall.
*) Not included in the delivery.
otective hood GS62 with GS62-Cor
1. Determine the exact wall thickness by
. interior plaster.
2. Add 10mm for the projection at the
equired for masonry. The projection is required for correct
rect installation of the protection hood. installation of the flat duct.
d telescopic tube 2 telescopic tubes (extension)
Wall thickness (mm) Wall thickness (mm)
150 ... 324 325 ... 550 551 ... 1000
150 ... 324 325 ... 550 551 ... 1000
a)
b)
c)
Shorten the sleeve to
the wall thickness using
a grinder or jigsaw.
Subtract 20mm from the
wall thickness and shorten
the tube to the difference
using a grinder or jigsaw.
-
Keep pulling the telescopic
tube out of the sleeve until
the length corresponds
to the wall thickness.
-
-
Connect up the two telescopic tubes
such that they overlap by
at least 50mm.
Protect the tube combination using
durable, watertight adhesive tape*
)
.
Align the tube combination to the length
corresponding to the wall thickness.
12
GS62 Air Extraction System Installation and Operating Instructions 09/2013
INSTALLATION INSTALLATION
5.4 Fitting the telescopic tube into the wall
1. Insert the telescopic tube (3) into the wall opening. Ensure that the fastening elements (4) for the protec-
tive hood are inserted horizontally.
Masonry
Free area between
masonry and telescopic tube
Telescopic tube
Securing elements for
protective hood
Figure 6: Inserting the telescopic tube
2. Align the telescopic tube at an angle of 1-2° to the outside wall Use
polystyrene or wood wedges for securing.
Note - GS62 with protective hood:
Ensure that the two elements for securing the protective
hood (4) to the outer wall protrude no more than 2mm.
GS62 with GS62-Corner:
Ensure that the telescopic tube protrudes 10-15mm on the outside
wall. This ensures that the flat duct can be fitted correctly. Before inserting the telescopic tube,
turn the two brass sleeves upwards and affix the all-round sealing tape (included) at a distance
of 8mm from the outer edge of the telescopic tube (see Figure 11: no.
)
3. Use 2-component foam to fully foam the free area between the masonry and
telescopic tube (2).
4. Cut the installation foam inside and outside flush to the wall.
5. GS62 with GS62-Corner: Stick sealing tape all around the projection of the telescopic tube.
Caution
- The GS62 is not suitable for drying out buildings. Do not use the GS62 whilst con-
struction work is being carried out in the building. Close the telescopic tube to protect the fan.
This safeguards reliable functioning of the GS62 following completion of building work.
1
14
2
4
3
ca. 10 mm
4
3
2
1
13
13 GS62 Air Extraction System Installation and Operating Instructions 09/2013
INSTALLATION
2
1
5.5 Protective hood
Protective hood rear panel
Sealing tape
Holes for securing the rear panel to
the telescopic tube
Figure 7: Protective hood rear panel
1. Apply the sealing tape (included) on the rear panel as in Figure 7. Ensure to keep a gap of approx. 7mm
on the left and right from the outer edge for sliding on the protective hood.
2. Turn the board over. The sealing tape is facing the facade.
Protective hood cover
Sealing tape
Figure 8: Protective hood cover
3. Use the two screws (included) to attach the rear panel of the protective hood to the two
fastening elements of the telescopic tube
4. Seal the protective hood at the top edge as in Figure 8
5. Slide the protective hood*
)
onto the rear panel from above
Note: Remove the polystyrene spacer from the telescopic tube before fitting the protective
hood
*)
Use of the GS62-Blank protective hood only after coating (by customer) with Nano Set included
1
1
2
2
3
2
1
3
14
GS62 Air Extraction System Installation and Operating Instructions 09/2013
INSTALLATION INSTALLATION
5.6 Nonreturn valve
Fan housing
with fan
Nonreturn valve
Figure 9: Nonreturn valve and fan housing
1.
Insert the nonreturn valve (2) into the rear of the fan housing (1)
2.
Allow the four attachment hooks to audibly click into place
5.7 Fan housing
Housing screen
Housing cover
Fan housing
Hole for cable feedthrough
(PSU connection)
Nonreturn valve
Telescopic tube
Connector cable (2-wire) po-
sition from the masonry for
fan and PSU connection
Masonry
Hole for wall
attachment (4 x)
Figure 10: Fan housing installation on interior room side
1
1
1
2
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
1
2
15
13 GS62 Air Extraction System Installation and Operating Instructions 09/2013
INSTALLATION
Note: The polystyrene spacer, if still in, and any dirt residue must be removed from the tele-
scopic tube before the fan housing is fitted. Also, the 2-wire cable for connecting the fan to
the PSU must be wired at the designated place (7).
1. Remove the housing screen (1) and housing cover (2) from the fan housing (3). Undo the two screws to
remove the housing cover. The housing screen is clipped on.
2. Before final installation, drill four holes (Ø 6mm) in the wall for the wall attachment (9). To do this, position
the fan housing into the telescopic tube (6) from the interior wall side, align it and mark the places for
drilling at the four external holes for wall attachment (9) of the fan housing. Remove the fan housing, drill
the wall holes and insert the dowels (included).
3. Position the fan housing (3), including nonreturn valve (5), into the telescopic tube (6) from the interior
wall side. Before pushing the housing all the way to the wall, route the 2-wire cable for the fan and PSU
connection through the cable feedthrough hole (7).
4. Push the fan housing all the way to the wall and attach it to the masonry using the four screws (included)
at the four external holes for wall attachment (9).
5. Connect the cable in the fan housing to the connectors provided. Information on this is in Section Elec-
trical connection on Page 23.
6. Refit the housing screen (1) and housing cover (2).
16
GS62 Air Extraction System Installation and Operating Instructions 09/2013
INSTALLATION INSTALLATION
5.8 Inside baffle
Fan housing
Inside baffle
Mounting elements (x 4)
Figure 9: Fitting the Inside baffle
1. Put the Inside baffle (2) onto the fan housing (1) - as seen from the inside panel.
2. Allow the four mounting elements (3) to audibly click into place
Figure 10: (from left to right) inside baffle (curved plastic), glass inside baffle, tile inside baffle
1
2
3
3
2
17
13 GS62 Air Extraction System Installation and Operating Instructions 09/2013
INSTALLATION
35
11 10
8
4
9
6
7
3
14
1
5
2
13 12
70
( ) -35
5.9 Flat duct (GS62-Corner)
The flat duct is mounted onto the telescopic tube instead of the outer hood.
Note - Ensure that sealing tape is applied all around the telescopic tube.
Make sure that the flat duct is mounted at an angle of 1-2° towards the window reveal so that
any condensation is reliably drained away.
Masonry Exterior plaster
Interior plaster Sleeve (reveal grate)
Telescopic tube Insulation
inside baffle Wall bracket (x 2)
Fan housing Flat duct*
)
Window Wall hole break-out (left/right)
Window frame Sealing tape
*
)
Use the 500mm flat duct when the maximum value of y+z = 450mm.
Use the 1000mm flat duct when y+z is between 451mm and 950mm.
Figure 10: Fitting the flat duct (complete unit)
1. Add |y| and |z|.
2. Subtract 35mm from this value for the end position of the duct.
3. Shorten the flat duct on the side opposite the hole for the telescopic tube down to
the length determined: overall length of flat duct = 70mm + (y+z) - 35mm.
1
8
2 9
4
3
5
6
7
10
11
12
13
14
Masonry Exterior plaster
Interior plaster Sleeve (reveal grate)
Telescopic tube Insulation
inside baffle Wall bracket (x 2)
Fan housing Flat duct*
Window Wall hole break-out (left/right)
Window frame Sealing tape
Interior plaster Sleeve (reveal grate)
Telescopic tube Insulation
inside baffle Wall bracket (x 2)
Fan housing Flat duct*
Window Wall hole break-out (left/right)
Window frame Sealing tape
Masonry Exterior plaster
Interior plaster Sleeve (reveal grate)
Telescopic tube Insulation
inside baffle Wall bracket (x 2)
Fan housing Flat duct*
Window Wall hole break-out (left/right)
Window frame Sealing tape
Masonry Exterior plaster
18
GS62 Air Extraction System Installation and Operating Instructions 09/2013
INSTALLATION INSTALLATION
Telescopic tube sealing tape
Wall bracket (x 2)
Window reveal
Wall holder fixing fixing screws (x 4)
Insulation
Exterior plaster
Telescopic tube
Masonry
Figure 11: Fitting of wall brackets
1. Use the fixing screws (4) to attach the two wall brackets (2) to the outer wall.
Flat duct
Wall bracket (x 2)
Grate
Sleeve
Figure 12: Fitting of sleeve and grate
2. Push the circular opening on the flat duct onto the telescopic tube and secure it at the wall brackets (2).
3. Push the sleeve (4) for attaching the grate onto the flat duct.
4. Push the grate (3) onto the sleeve until it audible clicks into place (additional securing with acrylic as
required).
5.10 Dimensional drawings
5.10.1 GS62 with protective hood
Wall opening
Protective hood (outline)
Exterior side element (e.g. window, door)
Shown in the drawing is the situation most
aesthetic visually - the top edge of the protective hood is flush with
the top edge of the structural element or with the lower edge of the
soffit on the lintel.
Figure 13: Wall opening dimensional drawing, GS62 telescopic tube with protective hood (exterior view)
Note
- Keep to the minimum distance of 250mm away from other components on the exterior.
1
1
1
1
1
2
2
2
2
2
4
4
4
4
5
5
6
6
7
8
7
8
3
3
3
3
≥ 250
Ø1
15
78
78
2
1
19
13 GS62 Air Extraction System Installation and Operating Instructions 09/2013
INSTALLATION



ุ





300
300
Ø107
Ø103 1
≥ 50
Ø73
71
61




Air extraction system (as a complete assembly)
Figure 14: Dimensional drawing for GS62 with protective hood
Telescopic tube (extension)
Figure 15: Dimensional drawing for 2-part telescopic tube (extension)
Wall mounting box
Figure 16: Dimensional drawing for wall mounting box
Protective hood
Figure 17: Dimensional drawing for GS62 protective hood
20
GS62 Air Extraction System Installation and Operating Instructions 09/2013
INSTALLATION INSTALLATION



3
2
1
Inside baffle
Figure 18: Dimension drawing from left to right GS inside baffle (white, stainless, gold and silver), glass, tile
5.10.2 GS62 with GS62-Corner
Note -
The dimensional drawings for these components are in Section Dimensional drawings
for GS62 with protective hood - telescopic tube (extension), wall mounting box and inside baffle
Wall opening
Flat duct (outline)
Lower edge of soffit
(lintel)*
Outer edge of reveal
(masonry)
*) Take into consideration
insulation thickness and
any roller shutters
Figure 19: Wall opening dimensional drawing, GS62 telescopic tube with GS62-Corner (exterior view)
*
≥ 250
Ø1
15
≥ 200
102
102
2
1
3
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

inVENTer GS62 Installation And Operating Instructions Manual

Type
Installation And Operating Instructions Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI