6
List of Figures
Figure 1 Box dimensions, surface mount ..................................................................................... 17
Figure 2 MR-2312-DDR Box dimensions, semi-flush mounting with trim ring ............................. 18
Figure 3 Flush Trim Detail\ ........................................................................................................... 18
Figure 4 MR-2306-DDR/MR-2306-DR Box dimensions, mounting and trim ring ......................... 19
Figure 5 MMX-BBX-1024DS and MMX-BBX-1024DSR Installation Instructions and Dimensions 20
Figure 6 Installation of Adder Modules for MR-2312 LCD Panels ................................................ 21
Figure 7 Installation of Adder Modules for MR-2306 LCD Panels ................................................ 22
Figure 8 Main Fire Alarm Board DIP switch and jumper settings for MR-2312 LCD Panels ........ 23
Figure 9 Main Fire Alarm Board DIP switch and jumper settings for MR-2300 LCD Panels ........ 24
Figure 10 MR-2300-A Input Class-A Converter Adder Module ...................................................... 25
Figure 11 MR-2300-NC4/2 Output Class-A Converter Adder Module ........................................... 26
Figure 12 MR-2312-R12 twelve relay adder module ...................................................................... 26
Figure 13 MR-2312/06-R12/6 Relay programming ........................................................................ 27
Figure 14 MR-2306-R6 six relay adder module ............................................................................. 27
Figure 15 Polarity reversal and city tie module .............................................................................. 28
Figure 16 Initiating circuit – Class B or Style B wiring .................................................................... 29
Figure 17 Initiating circuit– Class A or Style D wiring ..................................................................... 30
Figure 18 Indicating circuit – Class B or Style Y wiring .................................................................. 31
Figure 19 Indicating circuit – Class A or Style Z wiring .................................................................. 31
Figure 20 Four-wire smoke detector wiring .................................................................................... 32
Figure 21 Dialer wiring ................................................................................................................... 32
Figure 22 Relay per zone (MR-2312-R12) Terminal connection .................................................... 33
Figure 23 Relay per zone (MR-2306-R6) Terminal connection ...................................................... 33
Figure 24 Connecting an FACP to a 3G4010CF Interface Device ................................................. 34
Figure 25 Polarity reversal and city tie module terminal connection .............................................. 35
Figure 26 Power supply connection ............................................................................................... 36
Figure 27 Power supply connection ............................................................................................... 40
Figure 28 LCD Display and control buttons .................................................................................... 42
Figure 29 Evacuation Codes .......................................................................................................... 48
Figure 30 MR-2300 Configuration .................................................................................................. 53
Figure 31 Enter passcode .............................................................................................................. 54
Figure 32 Command Menu ............................................................................................................. 55
Figure 33 MR-2300 Config menu ................................................................................................... 56
Figure 34 Feature Config menu ..................................................................................................... 56
Figure 35 The event log ................................................................................................................. 66
Figure 36 Walk test confirmation .................................................................................................... 67
Figure 37 Walk test zones .............................................................................................................. 68
Figure 38 Walk test active .............................................................................................................. 68
Figure 39 i3 loop test confirmation ................................................................................................. 69
Figure 40 i3 test zones ................................................................................................................... 69
Figure 41 i3 test not ready .............................................................................................................. 69
Figure 42 The selected zone is not i3 type ..................................................................................... 69
Figure 43 Dialer Config menu ........................................................................................................ 70