  • Hello! I am an AI chatbot trained to assist you with the Aiphone RY-3DL Installation & Operation Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
All manuals and user guides at all-guides.com
all-guides.com
All manuals and user guides at all-guides.com
for Optional Functions
MOUNTING INSTRUCTIONS
6-PIN CONNECTOR
0803 A
http://www.aiphone.com/
Printed in Thailand
AIPHONE CO., LTD., NAGOYA, JAPAN
AIPHONE CORPORATION, BELLEVUE, WA, USA
AIPHONE EUROPE N.V., ANTWERP, BELGIUM
■ MOUNTING
1.Take the mounting bracket off of the monitor unit.
2.Cut out the cable knock-out, as shown by the dotted lines.
3.Plug the 6-pin connector into slot.
4.Connect the wires to the terminal block. Attach the protection shield.
5.Attach the mounting bracket to a box. Mount the monotor unit onto the bracket.
1
4 5
1 65432
2
3
Strip jacket of cable. Put all
the wires neatly into slot to
avoid damage by pinching.
{
{
{
FOR MODELS FUNCTION (WIRE)
MK-1GD, MK-1HD, Ext. device control (Gray)
MK-2MCD, MK-2HCD porch light, etc. (Gray)
MK-2MCD
b1RY-3DL (Orange)
b2RY-3DL (Yellow)
MK-1GD, MK-2MCD
VIDEO
-
(White)
VIDEO + (Blue)
All manuals and user guides at all-guides.com
1A1
1A2
+
L
L
DC18V
RLSE.
DOOR1
2A1
2A2
DOOR2
6PIN CONNECT OR WIRING DIAGRAM
for MK-2MCD & MK-1GD
RY-3DL
EL-9S
AC Trans.
L1
C1
L2
C2
L3
C3
b1
b2
b3
D1
D2
E
EL-9S
MK-DBC
Master
MK-2MCD
Sub
MK-2HCD
2
4
4
PS18
MK
-
DG
C
2
PS24
: PS-1820DIN, PS-1820S, PS-1820UL (2A)
RY-3DL
EL-9S
EL-9S
5
PT
MAW-B
Sub
MK-2HCD
WHITE
RED(+)
BLACK(–)
OR
AN
GE
O
R
AN
G
E
Light
VIDEO +
VIDEO–
MONITOR
TV (75 ohm)
PS18
L
Local switch
MAW-B
PS24
MONITOR
TV (75 ohm)
2
Master
MK-2MCD
B1
B2
SUB
PS24PS18
: 24V DC power supply for MAW-B or Relay
locally available.
+
(MK-2HCD)
(MK-DGC 1 )
(MK-DGC 2 )
YELLOW
ORANGE
3
MK-D
2
Light
2
2
BLUE
WHITE
GRAY
GRAY
(MK-2HCD)
NOTE: YELLOW & ORANGE wire provides selective door release control
with RY-3DL adaptor. Works for MK-2MCD only.
NTSC
Contact rating:
0.5A (DC 30V. AC 125V)