MegaPower 48 release 1.06 is intended to bring all existing
units in the field up to the same version, regardless of
installation date.
Equipment required
PC or Laptop (Windows 95, 98, 2000 or NT 4.0).
Medium Philips head screw driver
Null modem cable
Female gender changer
MP-48 setup software
Saving System
Parameters
All data will be lost unless you save the system parameters to
flash memory.
1. On a AD2088/AD2079 Keyboard, turn the key switch to
Program. On a MegaPower Control Center keyboard,
press the Program Mode softkey.
2. Type 55 F2 immediately followed by 140 F2.
3. On an ADTTE Keyboard, make sure the keyboard is
unlocked and type the same commands. Wait
approximately one (1) minute before proceeding.
Installation & Download
1. Move the self-extracting file, MP48V106.exe (P/N 0720-
0310-0100), to a folder on your computer. Double-click on
the file to run it.
2. Remove the MEU (Main Electronic Unit) from the patch
panel, and locate and remove the screws covering the
electronics.
3. Carefully remove the MEU cover.
NOTE: Please use a static strap or ground yourself before
touching any of the MEU’s components.
2 American Dynamics
Part Number 8200-0341-9900 A0 ©Copyright 2003 Sencormatic Electronics Corp.
4. Locate jumper P-24 (Figure-1).
5. Move jumper P-24 from Operate position (Figure-2) to
Program position (Figure-3)
6. Insert the MEU into the patch panel within one (1)
minute. The heartbeat LED on the patch panel will blink
rapidly, indicating MP-48 is ready to receive download
information.
7. Connect the null modem cable from COM 1 on your PC
to the DB-9 connector on the patch panel.
8. Read the Readme.txt file.
9. For 32-bit Windows Operating Systems, run MP48.bat
(for COM1) or MP48COM2.bat (for COM2).
10. For 16-bit Windows Operating Systems, follow the
directions in the Readme.txt file for further instructions.
11. When the download is complete, remove the MEU. Move
the P-24 jumper back to Operate mode (Figure-2) and
replace the cover.
12. Insert the MEU. The heartbeat LED should blink once per
second. Establish communication with the keyboard.
13. Using your keyboard (the key switch must be in Program
for AD2088/2079 keyboards, unlocked for an ADTTE
keyboard), type 70 F2.
Figure 1 Figure 2 Figure 3
MegaPower 48 Release 1.06 Installation Guidelines 3
Part Number 8200-0341-9900 A0 ©Copyright 2003 Sencormatic Electronics Corp.
14. The Hold display on your monitor changes to v1.06, and
the upgrade is complete.
Restoring System
Parameters
To restore system parameters from flash memory:
1. On an AD2088/AD2079 Keyboard, turn the key switch
to Program. On a MegaPower Control Center keyboard,
press the Program Mode softkey.
2. Type 55 F2 immediately followed by 141 F2.
3. On an ADTTE Keyboard, make sure the keyboard is
unlocked and type the same commands. Wait
approximately one (1) minute for the system parameters
to be restored.
4 American Dynamics
Part Number 8200-0341-9900 A0 ©Copyright 2003 Sencormatic Electronics Corp.
Thank you for using American Dynamics products. We support our products through an extensive worldwide network of
dealers. The dealer through whom you originally purchased this product is your point of contact if you need service or
support. Our dealers are empowered to provide the very best in customer service and support. Dealers should contact
American Dynamics at (800) 507-6268 or (561) 912-6259 or on the web at www.americandynamics.net.
©Copyright 2003 Sensormatic Electronics Corporation
©American Dynamics
6795 Flanders Drive
San Diego, California 92121-2903
Part Number 8200-0341-9900 A0
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

American Dynamics MegaPower 48 Installation Manuallines

Type
Installation Manuallines

American Dynamics MegaPower 48 is a powerful and versatile access control system designed to meet the needs of businesses of all sizes. With its advanced features and capabilities, the MegaPower 48 can help you to improve security, manage employee access, and track activity throughout your facility.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI