ASRock Rack SPC741D8QM3-2T/X550 User manual

Category
Server/workstation motherboards
Type
User manual
SPC741D8QM3-2T/X550
User Manual
Version 1.0
Published March 2023
Copyright©2023 ASRock Rack INC. All rights reserved.
Version 1.0
Published March 2023
Copyright©2023 ASRock Rack INC. All rights reserved.
Copyright Notice:
No part of this documentation may be reproduced, transcribed, transmitted, or translated
in any language, in any form or by any means, except duplication of documentation by the
purchaser for backup purpose, without written consent of ASRock Rack Inc.
Products and corporate names appearing in this documentation may or may not be
registered trademarks or copyrights of their respective companies, and are used only for
identication or explanation and to the owners’ benet, without intent to infringe.
Disclaimer:
Specifications and information contained in this documentation are furnished for
informational use only and subject to change wit hout notice, and should not be
constructed as a commitment by ASRock Rack. ASRock Rack assumes no responsibility
for any errors or omissions that may appear in this documentation.
With respect to the contents of this documentation, ASRock Rack does not provide
warranty of any kind, either expressed or implied, including but not limited to the implied
warranties or conditions of merchantability or tness for a particular purpose.
In no event shall ASRock Rack, its directors, ocers, employees, or agents be liable for
any indirect, special, incidental, or consequential damages (including damages for loss of
prots, loss of business, loss of data, interruption of business and the like), even if ASRock
Rack has been advised of the possibility of such damages arising from any defect or error
in the documentation or product.
is device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
is equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. ese limits are designed to provide reason-
able protection against harmful interference in a residential installation. is equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in ac-
cordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment o and on, the user is encouraged to try to
correct the interference by one or more of the following
measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit dierent from that to which the
receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
INTEL END USER SOFTWARE LICENSE AGREEMENT
IMPORTANT - READ BEFORE COPYING, INSTALLING OR USING.
LICENSE. Licensee has a license under Intels copyrights to reproduce Intel’s Software
only in its unmodified and binary form, (with the accompanying documentation, the
“Soware”) for Licensees personal use only, and not commercial use, in connection with
Intel-based products for which the Soware has been provided, subject to the following
conditions:
(a) Licensee may not disclose, distribute or transfer any part of the Soware, and You agree
to prevent unauthorized copying of the Soware.
(b) Licensee may not reverse engineer, decompile, or disassemble the Soware.
(c) Licensee may not sublicense the Soware.
(d) e Soware may contain the soware and other intellectual property of third party
suppliers, some of which may be identied in, and licensed in accordance with, an enclosed
license.txt le or other text or le.
(e) Intel has no obligation to provide any support, technical assistance or updates for the
Soware.
OWNERSHIP OF SOFTWARE AND COPYRIGHTS. Title to all copies of the Soware
remains with Intel or its licensors or suppliers. e Soware is copyrighted and protected
by the laws of the United States and other countries, and international treaty provisions.
Licensee may not remove any copyright notices from the Soware. Except as otherwise ex-
pressly provided above, Intel grants no express or implied right under Intel patents, copy-
rights, trademarks, or other intellectual property rights. Transfer of the license terminates
Licensee’s right to use the Soware.
DISCLAIMER OF WARRANTY. e Soware is provided “AS IS” without warranty of
any kind, EITHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION,
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PUR-
POSE.
LIMITATION OF LIABILITY. NEITHER INTEL NOR ITS LICENSORS OR SUPPLIERS
WILL BE LIABLE FOR ANY LOSS OF PROFITS, LOSS OF USE, INTERRUPTION OF
BUSINESS, OR INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAG-
ES OF ANY KIND WHETHER UNDER THIS AGREEMENT OR OTHERWISE, EVEN
IF INTEL HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
LICENSE TO USE COMMENTS AND SUGGESTIONS. is Agreement does NOT ob-
ligate Licensee to provide Intel with comments or suggestions regarding the Software.
However, if Licensee provides Intel with comments or suggestions for the modication,
correction, improvement or enhancement of (a) the Soware or (b) Intel products or pro-
cesses that work with the Soware, Licensee grants to Intel a non-exclusive, worldwide,
perpetual, irrevocable, transferable, royalty-free license, with the right to sublicense, under
Licensee’s intellectual property rights, to incorporate or otherwise utilize those comments
and suggestions.
TERMINATION OF THIS LICENSE. Intel or the sublicensor may terminate this license
at any time if Licensee is in breach of any of its terms or conditions. Upon termination,
Licensee will immediately destroy or return to Intel all copies of the Soware.
THIRD PARTY BENEFICIARY. Intel is an intended beneciary of the End User License
Agreement and has the right to enforce all of its terms.
U.S. GOVERNMENT RESTRICTED RIGHTS. The Software is a commercial item (as
dened in 48 C.F.R. 2.101) consisting of commercial computer soware and commercial
computer soware documentation (as those terms are used in 48 C.F.R. 12.212), consistent
with 48 C.F.R. 12.212 and 48 C.F.R 227.7202-1 through 227.7202-4. You will not provide
the Soware to the U.S. Government. Contractor or Manufacturer is Intel Corporation,
2200 Mission College Blvd., Santa Clara, CA 95054.
EXPORT LAWS. Licensee agrees that neither Licensee nor Licensee’s subsidiaries will
export/re-export the Software, directly or indirectly, to any country for which the U.S.
Department of Commerce or any other agency or department of the U.S. Government or
the foreign government from where it is shipping requires an export license, or other gov-
ernmental approval, without rst obtaining any such required license or approval. In the
event the Soware is exported from the U.S.A. or re-exported from a foreign destination
by Licensee, Licensee will ensure that the distribution and export/re-export or import of
the Soware complies with all laws, regulations, orders, or other restrictions of the U.S.
Export Administration Regulations and the appropriate foreign government.
APPLICABLE LAWS. is Agreement and any dispute arising out of or relating to it will
be governed by the laws of the U.S.A. and Delaware, without regard to conflict of laws
principles. e Parties to this Agreement exclude the application of the United Nations
Convention on Contracts for the International Sale of Goods (1980). e state and federal
courts sitting in Delaware, U.S.A. will have exclusive jurisdiction over any dispute arising
out of or relating to this Agreement. e Parties consent to personal jurisdiction and venue
in those courts. A Party that obtains a judgment against the other Party in the courts iden-
tied in this section may enforce that judgment in any court that has jurisdiction over the
Parties.
Licensee’s specic rights may vary from country to country.
CALIFORNIA, USA ONLY
e Lithium battery adopted on this motherboard contains Perchlorate, a toxic substance
controlled in Perchlorate Best Management Practices (BMP) regulations passed by the
California Legislature. When you discard the Lithium battery in California, USA, please
follow the related regulations in advance.
“Perchlorate Material-special handling may apply, see www.dtsc.ca.gov/hazardouswaste/
perchlorate
AUSTRALIA ONLY
Our goods come with guarantees that cannot be excluded under the Australian Consumer
Law. You are entitled to a replacement or refund for a major failure and compensation for
any other reasonably foreseeable loss or damage caused by our goods. You are also entitled
to have the goods repaired or replaced if the goods fail to be of acceptable quality and the
failure does not amount to a major failure. If you require assistance please call ASRock
Rack Tel : +886-2-55599600 ext.123 (Standard International call charges apply)
ASRock Rack INC. hereby declares that this device is in compliance with the essential re-
quirements and other relevant provisions of related UKCA Directives. Full text of UKCA
declaration of conformity is available at: http://www.asrockrack.com
ASRock Rack INC. hereby declares that this device is in compliance with the essential re-
quirements and other relevant provisions of related Directives. Full text of EU declaration
of conformity is available at: http://www.asrockrack.com
ASRock Rack follows the green design concept to design and manufacture our products,
and makes sure that each stage of the product life cycle of ASRock Rack product is in line
with global environmental regulations. In addition, ASRock Rack disclose the relevant in-
formation based on regulation requirements.
Please refer to https://www.asrockrack.com/general/about.asp?cat=Responsibility for in-
formation disclosure based on regulation requirements ASRock Rack is complied with:
DO NOT throw the motherboard in municipal waste. is product has been
designed to enable proper reuse of parts and recycling. This symbol of the
crossed out wheeled bin indicates that the product (electrical and electronic
equipment) should not be placed in municipal waste. Check local regulations
for disposal of electronic products.
Contents
Chapter 1 Introduction 1
1.1 Package Contents 1
1.2 Specications 2
1.3 Unique Features 5
1.4 Motherboard Layout 6
1.5 Onboard LED Indicators 9
1.6 I/O Panel 11
1.7 Block Diagram 13
Chapter 2 Installation 14
2.1 Screw Holes 14
2.2 Pre-installation Precautions 14
2.3 Installing the CPU and Heatsink 15
2.4 Installation of Memory Modules (DIMM) 21
2.5 Expansion Slots (PCI Express Slots) 23
2.6 Jumper Setup 24
2.7 Onboard Headers and Connectors 26
2.8 ATX PSU Power Connections 33
2.9 Dr. Debug 34
2.10 Unit Identication purpose LED/Switch 40
2.11 Dua LAN and Teaming Operation Guide 41
2.12 M.2 SSD Module Installation Guide 42
Chapter 3 UEFI Setup Utility 44
3.1 Introduction 44
3.1.1 UEFI Menu Bar 44
3.1.2 Navigation Keys 45
3.2 Main Screen 46
3.2.1 Motherboard Information 47
3.2.2 Processor Information 47
3.2.3 Memory Information 48
3.3 Advanced Screen 49
3.3.1 CPU Conguration 50
3.3.2 Platform Power Conguration 52
3.3.3 DRAM Conguration 55
3.3.4 Chipset Conguration 57
3.3.5 Storage Conguration 60
3.3.6 NVMe Conguration 3.3 NVMe Conguration 61
3.3.7 ACPI Conguration 62
3.3.8 USB Conguration 63
3.3.9 Super IO Conguration 64
3.3.10 Serial Port Console Redirection 65
3.3.11 H/W Monitor 68
3.3.12 Runtime Error Logging 69
3.3.13 Intel SPS Conguration 71
3.3.14 Network Stack Conguration 72
3.3.15 Intel® VMD technology 73
3.3.16 Driver Health 74
3.3.17 Tls Auth Conguration 75
3.3.18 Instant Flash 76
3.4 Server Mgmt 77
3.4.1 BMC Network Conguration 79
3.4.2 System Event Log 81
3.4.3 BMC Tools 82
3.5 Security 83
3.5.1 Key Management 84
3.6 Event Logs 88
3.7 Boot Screen 89
3.8 Exit Screen 90
Chapter 4 Software Support 91
4.1 Download and Install Operating System 91
4.2 Download and Install Software Drivers 91
4.3 Contact Information 91
Chapter 5 Troubleshooting 92
5.1 Troubleshooting Procedures 92
5.2 Technical Support Procedures 94
5.3 Returning Merchandise for Service 94
SPC741D8QM3-2T/X550
PB 1
English
Chapter 1 Introduction
ank you f or p urchasing A SRock R ack SPC741D8QM3-2T/X550 motherboard, a reliable
motherboard produced under ASRock Racks consistently stringent quality control. It delivers
excellent performance with robust design conforming to ASRock Racks commitment to
quality and endurance.
In this manual, chapter 1 and 2 contains introduction of the motherboard and step-by-step
guide to the hardware installation. Chapter 3 and 4 contains the configuration guide to
BIOS setup and information of the software support.
1.1 Package Contents
ASRock Rack SPC741D8QM3-2T/X550 Motherboard
(CEB Form Factor: 12-in x 10.5-in)
Quick Installation Guide
1 x SATA3 Cable (60cm)
1 x Oculink to 4 SATA Cable (60cm)
1 x I/O Shield
2 x Screws for M.2 Sockets
2 x CPU Non-Fabric Carriers
If any items are missing or appear damaged, contact your authorized dealer.
Because the motherboard specications and the BIOS soware might be updated, the con-
tent of this manual will be subject to change without notice. In case any modications of
this manual occur, the updated version will be available on ASRock Rack website without
further notice. You may nd the latest memory and CPU support lists on ASRock Rack
website as well. ASRock Rack’s Website: www.ASRockRack.com
If you require technical support related to this motherboard, please visit our website for
specic information about the model you are using.
http://www.asrockrack.com/support/
2 3
English
1.2 Specications
SPC741D8QM3-2T/X550
Physical Status
Form Factor CEB
Dimension 12” x 10.5” (304.8 x 266.7 mm)
Processor System
CPU Supports 4th Gen Intel® Xeon® Scalable Processors
Socket Single Socket E (LGA 4677)
ermal Design
Power (TDP)
~350W
Chipset Intel® C741
System Memory
Supported DIMM
Quantity
8 DIMM slots (1DPC)
Supported Type 288-pin DDR5 RDIMM/RDIMM-3DS
Max. Capacity per
DIMM
RDIMM:64GB
RDIMM-3DS: 256GB
Max. Frequency 4800 MT/s
Voltage 1.1V
Note Memory support is to be validated
PCIe Expansion Slots (SLOT7 close to CPU)
SLOT6 PCIe5.0 / CXL1.1 x16 [CPU]
SLOT1 PCIe4.0 x16 [CPU]
Other PCIe Expansion Connectors
M.2 slot 1 M-key M2_1 (PCIe3.0 x4 or SATA 6Gb/s), supports 2280/2260
form factor [PCH]
1 M-key M2_2 (PCIe3.0 x4 or SATA 6Gb/s), supports
22110/2280 form factor [PCH]
OCuLink 1 OCuLink (PCIe3.0 x4 or 4 SATA 6Gb/s) [PCH]
MCIO 4 MCIO (PCIE5.0 x8) [CPU]
SATA/SAS Storage
PCH Built-in
Storage
Intel® C741 (Up to 8 SATA 6Gb/s, support RAID 0/1/5/10):
1 OCuLink, 2 SATA 7-pin, 2 M.2
Ethernet
OCP slot 1 OCP NIC 3.0 (PCIe5.0 / CXL1.1 x16) [CPU]
USB
Controller/Hub ASMedia ASM1074
Connectors/
headers
External:
2 Type A (USB3.2 Gen1)
Internal:
1 header (19-pin, 2 USB3.2 Gen1)
1 header (9-pin, 2 USB2.0)
SPC741D8QM3-2T/X550
2 3
English
Graphics
Controller ASPEED AST2600:
1 DB15 (VGA), 1 header
Security
TPM 1 (13-pin, SPI)
Rear I/O
UID button/LED 1 UID button w/ LED
Video output 1 DB15 (VGA)
Serial port 1 DB9 (COM)
USB 2 Type A (USB3.2 Gen1)
RJ45 2 RJ45 (10GbE), 1 dedicated IPMI
Hardware Monitor
Temperature CPU, PCH, MB, Card Side, M.2, RAM, TR1 Temperature
Sensing
Fan Fan Tachometer
CPU Quiet Fan (Allow Chassis Fan Speed Auto-Adjust by
CPU Temperature)
Fan Multi-Speed Control
Voltage 1.05V_PCH, 1.8V_PCH, +BAT, PVNN_PCH, 3.3V, 5V, 12V,
3.3VSB, 5VSB, 12V, +12VSB
Server Management
BMC Controller ASPEED AST2600: IPMI2.0 with iKVM and vMedia support
IPMI Dedicated
GLAN
1 RJ45 Dedicated IPMI LAN port by Realtek RTL8211F
System BIOS
BIOS type AMI UEFI BIOS; 512Mb SPI Flash ROM
Features Plug and Play (PnP), ACPI 4.0 and above compliance wake up
events, SMBIOS 3.4 and above , ASRock Rack Instant Flash
Internal Connectors/Headers
PSU connector 1 Micro-Fit (4-pin, ATX PSU signal) w/ ATX 24-pin adapter
cable, 3 (8-pin, ATX 12V)
Auxiliary panel
header
1 (18-pin): chassis intrusion, system fault LED, LAN1/LAN2
activity LED, locate, SMBus
System panel
header
1 (9-pin): power switch, reset switch, system power LED, HDD
activity LED
NMI button/
header
1
VGA header 1 (15-pin)
Speaker header 1 (4-pin)
Fan header 8 (6-pin)
ermal sensor
header
1
TPM header 1 (13-pin, SPI)
VROC header 1
4 5
English
SGPIO header 2
HSBP 1
SMbus header 1
PMbus header 1
IPMB header 1
Clear CMOS 1 (contact pads)
LED Indicators
Standby Power
LED
1
80 debug port LED 1
Fan Fail LED 8
BMC Heartbeat
LED
1
Supported OS
OS Microso® Window
- Server 2022 (64bit)
Linux®
- RedHat Enterprise Linux Server 8.4 (64bit) / 8.5 (64bit) / 8.6
(64bit) / 8.7 (64bit) / 9.0 (64bit) / 9.1 (64bit)
- SUSE Enterprise Linux Server 15 SP3 (64bit) / 15 SP4 (64bit)
- Ubuntu 21.10 (64bit) / 22.04 (64bit) / 22.10 (64bit)
Hypervisor
- VMWare® ESXi 7.0 U3g / 8.0
*Please refer to our website for the latest OS support list.
Enviroment
Operating
temperature
10 - 3C (50 - 95 degF)
Non-operating
temperature
-40 - 70°C (-40 - 158degF)
NOTE: Please refer to our website for the latest specications.
If you install Intel® LAN utility or Marvell SATA utility, this motherboard may fail Win-
dows® Hardware Quality Lab (WHQL) certication tests. If you install the drivers only, it
will pass the WHQL tests.
is motherboard supports Wake from on Board LAN. To use this function, please make
sure that the “Wake on Magic Packet from power o state” is enabled in Device Manager
> Intel® Ethernet Connection > Power Management. And the “PCI Devices Power On” is
enabled in UEFI SETUP UTILITY > Advanced > ACPI Conguration. Aer that, onboard
LAN1&2 can wake up S5 under OS.
SPC741D8QM3-2T/X550
4 5
English
1.3 Unique Features
ASRock Rack Instant Flash is a BIOS ash utility embedded in Flash ROM. is convenient
BIOS update tool allows you to update system BIOS without entering operating systems rst
like MS-DOS or Windows®. With this utility, you can press the <F6> key during the POST or
the <F2> key to enter into the BIOS setup menu to access ASRock Rack Instant Flash. Just
launch this tool and save the new BIOS le to your USB ash drive, oppy disk or hard drive,
then you can update your BIOS only in a few clicks without preparing an additional oppy
diskette or other complicated ash utility. Please be noted that the USB ash drive or hard
drive must use FAT32/16/12 le system.
6 7
English
1.4 Motherboard Layout
SPC741D8QM3-2T/X550
26.7 cm (10.5 in)
30.5 cm (12 in)
8.1cm (3.2in)
UID1
T:USB3_2
B:USB3_1
CPU1_HSBP1
IPMI_LAN
USB 3.2
Gen1 Ports
LAN1
LAN2
VGA_COM1
ASPEED
AST2600
CPU0
BMC
ROM
PECI1
BMC_SMB1
IPMB1 FLASH_SEC_OVERRIDE1
BIOS
ROM
TPM_BIOS_PH1
RAID_1
AUX_PANEL1
SPEAKER1
TR1
PANEL1
SATA_0_1
BAT1
FAN7
FAN8
FAN3
FAN4
FAN5
FAN6
ATX12V1
ATX12V2
ATX12V3
MCIO1
MCIO2
PSU_SMB1
ATX4PIN1
PWM_CFG1
FRNT_VGA1
MCIO3
MCIO4
DDR5_D1
DDR5_C1
DDR5_B1
DDR5_A1
DDR5_E1
DDR5_F1
DDR5_G1
DDR5_H1
FAN1
FAN2
OCU1
MIPI1
M2_1
M2_2
BMC_PH1
USB3_3_4
BIOS_PH1
SATA0_SGPIOSATA1_SGPIO
USB_1_2NMI_BTN1
+12VSB_SEL1
PASSWORD_CLEAR1
ME_RECOVERY1
OCUSW_1
BIOS_SWAP_OVERRIDE1
PCIE1
PCIE6
OCP1
CLRMOS1
Intel
X550-AT2
SUPER
I/O
Dr. Debug
NUT80_2
NUT110_1
1
8
9
7
11
12
19
15
16
13
14
17
18
20
21
2 3 4
10
23
24
25
26
27
29
3132
37
38
39
56
22
28
30
33
34
35
36
4041
42
4344
45
46
47
48
49
50
52
51
53
SPC741D8QM3-2T/X550
6 7
English
No. Description
1 Backplane PCI Express Hot-Plug Connector (CPU1_HSBP1)
2 Front VGA Header (FRNT_VGA1)
3 Mini Cool Edge IO x8 Connector (MCIO3)
4 Mini Cool Edge IO x8 Connector (MCIO4)
5 2 x 288-pin DDR5 DIMM Slots (DDR5_B1, DDR5_D1)*
6 2 x 288-pin DDR5 DIMM Slots (DDR5_A1, DDR5_C1)*
7 System Fan Connector (FAN1)
8 Mini Cool Edge IO x8 Connector (MCIO1)
9 Mini Cool Edge IO x8 Connector (MCIO2)
10 System Fan Connector (FAN2)
11 PWM Conguration Header (PWM_CFG1)
12 Micro-Fit ATX 4Pin Power Connector (ATX4PIN1)
13 ATX 12V Power Connector (ATX12V1)
14 2 x 288-pin DDR5 DIMM Slots (DDR5_E1, DDR5_G1)*
15 2 x 288-pin DDR5 DIMM Slots (DDR5_F1, DDR5_H1)*
16 ATX 12V Power Connector (ATX12V2)
17 PSU SMBus Header (PSU_SMB1)
18 ATX 12V Power Connector (ATX12V3)
19 OCuLink Connector (OCU1)
20 System Fan Connector (FAN3)
21 System Fan Connector (FAN4)
22 M-key M.2 Socket (M2_2) (Type 22110/2280)
23 System Fan Connector (FAN5)
24 System Fan Connector (FAN6)
25 Serial ATA3 Connectors (SATA_1)(Upper), (SATA_0)(Lower)
26 USB 3.2 Gen1 Header (USB3_3_4)
27 System Fan Connector (FAN7)
28 Clear CMOS Pad (CLRMOS1)
29 System Fan Connector (FAN8)
30 SATA SGPIO Connector (SATA0_SGPIO)
31 Virtual RAID On CPU Header (RAID_1)
32 Flash Override Jumper (FLASH_SEC_OVERRIDE1)
33 System Panel Header (PANEL1)
34 SATA SGPIO Connector (SATA1_SGPIO)
8 9
English
No. Description
35 Auxiliary Panel Header (AUX_PANEL1)
36 Speaker Header (SPEAKER1)
37 USB 2.0 Header (USB_1_2)
38 Non Maskable Interrupt Button (NMI_BTN1)
39 OCP3 +12VSB Power Jumper (+12VSB_SEL1)
40 ermal Sensor Header (TR1)
41 SPI TPM Header (TPM_BIOS_PH1)
42 BIOS Swap Override Jumper (BIOS_SWAP_OVERRIDE1)
43 ME Recovery Jumper (ME_RECOVERY1)
44 Switch SATA and PCIE Jumper (OCUSW_1)
45 BMC SMBus Header (BMC_SMB1)
46 Intelligent Platform Management Bus Header (IPMB1)
47 Password Reset Jumper (PASSWORD_CLEAR1)
48 PCI Express 4.0 x16 Slot (PCIE1)
49 OCP 3.0 Gen5 x16 NIC Slot (OCP1)
50 M-key M.2 Socket (M2_1) (Type 2280/2260)
51 PCI Express 5.0 x16 Slot (PCIE6)
52 CPU PECI Mode Jumper (PECI1)
53 LGA 4677 CPU Socket (CPU0)
*For DIMM installation and conguration instructions, please see p.21 (Installation of Memory Modules
(DIMM)) for more details.
SPC741D8QM3-2T/X550
8 9
English
1.5 Onboard LED Indicators
1
2
3
4
5
6
7
8
9
10
11
10 11
English
No. Item Status Description
1LED_FAN1 Red FAN1 failed
2LED_FAN2 Red FAN2 failed
3LED_CATERR1 Red CPU CATERR error
4BMC_LED Green BMC heartbeat LED
5LED_FAN3 Red FAN3 failed
6LED_FAN4 Red FAN4 failed
7LED_FAN5 Red FAN5 failed
8LED_FAN6 Red FAN6 failed
9LED_FAN7 Red FAN7 failed
10 LED_FAN8 Red FAN8 failed
11 SB_PWR1 Green STB PWR ready
SPC741D8QM3-2T/X550
10 11
English
1.6 I/O Panel
621 4
3 5
7
No. Description No. Description
1 UID Switch (UID1) 5 LAN RJ-45 Port (IPMI_LAN)*
2VGA Port (VGA) 6 10G LAN RJ-45 Port (LAN2)**
3 Serial Port (COM1) 7 10G LAN RJ-45 Port (LAN1)**
4 USB 3.2 Gen1 Ports (USB3_1_2)
LAN Port LED Indications
*ere are two LEDs on each LAN port. Please refer to the table below for the LAN port
LED indications.
Dedicated IPMI LAN Port LED Indications
Activity / Link LED Speed LED
Status Description Status Description
O No Link O 10Mbps connection or
no link
Blinking Yellow Data Activity Orange 100Mbps connection
On Link Green 1Gbps connection
ACT/LINK LED
SPEED LED
LAN Port
12 13
English
**ere are two LEDs on each LAN port. Please refer to the table below for the LAN port
LED indications.
10G LAN Port LED Indications
Activity / Link LED Speed LED
Status Description Status Description
O No Link O 100Mbps connection or no
link
Blinking Green Data Activity Orange 1Gbps connection
On Link Green 10Gbps connection
ACT/LINK LED
SPEED LED
LAN Port
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103

ASRock Rack SPC741D8QM3-2T/X550 User manual

Category
Server/workstation motherboards
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI