Rosemount Eagle Eye Quick start guide

Type
Quick start guide
Quick Installation Guide
00825-0100-4833, Rev AA
January 2004
Rosemount Eagle Eye
www.rosemount.com
¢00825-0100-4833+¤
Rosemount Eagle Eye
Step 1: Location and Orientation
Step 2: Mounting
Step 3: Operation
Step 4: Calibration
Step 5: Removal From Service (if needed)
Approval
4833 Rev AA.fm Page 1 Wednesday, January 14, 2004 3:35 PM
Quick Installation Guide
00825-0100-4833, Rev AA
January 2004
Rosemount Eagle Eye
© 2004 Rosemount Inc. All rights reserved. All marks are the property of their owners.
Rosemount Inc.
8200 Market Boulevard
Chanhassen, MN USA 55317
T (US) (800) 999-9307
T (Intnl) (952) 906-8888
F (952) 949-7001
Emerson Process Management
GmbH & Co. OHG
Argelsrieder Feld 3
82234 Wessling
Germany
T 49 (8153) 9390
F49 (8153) 939172
Emerson Process Management
Asia Pacific Private Limited
1 Pandan Crescent
Singapore 128461
T (65) 6777 8211
F (65) 6777 0947/65 6777 0743
Beijing Rosemount Far East
Instrument Co., Limited
No. 6 North Street,
Hepingli, Dong Cheng District
Beijing 100013, China
T (86) (10) 6428 2233
F (86) (10) 6422 8586
IMPORTANT NOTICE
This installation guide provides basic guidelines for Rosemount Eagle Eye
Fire Pump. It does not provide instructions for configuration, diagnostics,
maintenance, service, troubleshooting, Explosion-proof, Flame-Proof, or
instrinsically safe (I.S.) installations. Refer to the Rosemount Eagle Eye
Series Product Data Sheet (document number 00813-0100-4830) or the
Eagle Eye QIG (document number 00825-0100-4833) for more information.
These documents are also available electronically on www.rosemount.com.
WARNING
Process leaks may cause harm or result in death. To avoid process leaks,
only use gaskets designed to seal with the corresponding flange and o-rings
to seal process connections. Flowing medium may cause the 485 Annubar
assembly to become hot and could result in burns.
4833 Rev AA.fm Page 2 Wednesday, January 14, 2004 3:35 PM
Quick Installation Guide
00825-0100-4833, Rev AA
January 2004
Rosemount Eagle Eye
EXPLODED VIEW
Front View
Zero Adjust Knob
7.13 (181.1)
5.25 (133.4)
HI Pressure
LO Pressure
21-490000-901B, 901C
Dimensions are in inches (millimeters)
4833 Rev AA.fm Page 3 Wednesday, January 14, 2004 3:35 PM
Quick Installation Guide
00825-0100-4833, Rev AA
January 2004
Rosemount Eagle Eye
Side View
6.13 (155.7)
Zero Adjust Knob
Zero Adjust Knob
Bleed Valves
1
/4-in. SAE Flare Fitting
2.5 (63.5)
21-490000-901D, 901A
Dimensions are in inches (millimeters)
4833 Rev AA.fm Page 4 Wednesday, January 14, 2004 3:35 PM
Quick Installation Guide
00825-0100-4833, Rev AA
January 2004
Rosemount Eagle Eye
STEP 1: LOCATION AND ORIENTATION
Orientation
Horizontal
For proper venting and draining, the sensor should be located in the
upper half of the pipe for air and gas applications. For liquid
applications, the sensor should be located in the bottom half of the
pipe.
Figure 1. Gas
Figure 2. Liquid
21-490000-902B
Recommended Zone
120°
30°
30°
21-490000-902C
Recommended Zone
80°
50°
50°
4833 Rev AA.fm Page 5 Wednesday, January 14, 2004 3:35 PM
Quick Installation Guide
00825-0100-4833, Rev AA
January 2004
Rosemount Eagle Eye
STEP 1 CONTINUED...
Vertical
The sensor can be installed in any position around the circumference
of the pipe provided the vents are positioned properly for bleeding or
venting. Optimal results for liquid are obtained when the flow is up.
The preferred orientation for air or gas is when the flow is down, but
upwards flow is acceptable.
Figure 3. Liquid
Figure 4. Gas
21-490000-903B
360°
Flow
21-490000-903B
360°
Flow
4833 Rev AA.fm Page 6 Wednesday, January 14, 2004 3:35 PM
Quick Installation Guide
00825-0100-4833, Rev AA
January 2004
Rosemount Eagle Eye
STEP 1 CONTINUED...
Permanent Meters
Install the meter with the dial face in a level horizontal position. This
can easily be check with a level. Meter must be installed within ±30°
from the vertical position.
Figure 5. Horizontal
Figure 6. Vertical
NOTE
Use in any other position requires recalibration.
21-490000-907F
30° 30°
4833 Rev AA.fm Page 7 Wednesday, January 14, 2004 3:35 PM
Quick Installation Guide
00825-0100-4833, Rev AA
January 2004
Rosemount Eagle Eye
STEP 1 CONTINUED...
Portable Meters
Portable meters must be used with the dial face in a vertical position.
NOTE
Use in any other position requires recalibration.
Figure 7. Portable Meter Case
21-490000-908A, 908B, 908C, 908D
14.9 (378.5)
14.9
(378.5)
Eagle Eye
Flow Indicator
7.8 (198.1)
8.3
(210.8)
10.0 (254)
5.0 (127.0)
Dimensions are in inches (millimeters)
4833 Rev AA.fm Page 8 Wednesday, January 14, 2004 3:35 PM
Quick Installation Guide
00825-0100-4833, Rev AA
January 2004
Rosemount Eagle Eye
STEP 2: MOUNTING
Pipe
The Eagle Eye can be mounted on any
1
/2 to 2-in. (10 to 50 mm)
vertical or horizontal pipe.
NOTE
A wood spacer of 2 x 4 x
3
/4-in. (50 x 100 x 20 mm) is required for
mounting on pipe
1
/2 to 1-in. (10 to 25 mm). Screw holes are provided
in the pipe mounting bracket to attaching the spacer
1. Insert the two “U” bolts through the large holes in the meter
bracket.
2. Torque the flange bolts to only 50 in/lb (56 kg/cm).
Figure 8. Pipe Mounting
21-490000-904A
Mounting U-Bolt
1
/2 to 2 (10 to 50)
Dimensions are in inches (millimeters)
4833 Rev AA.fm Page 9 Wednesday, January 14, 2004 3:35 PM
Quick Installation Guide
00825-0100-4833, Rev AA
January 2004
Rosemount Eagle Eye
STEP 2 CONTINUED...
Wall
The Eagle Eye can be wall mounted by removing the mounting
bracket from the meter. This permits access to the to
3
/16-in. (5 mm)
holes in the bracket
NOTE
Only remove the two flange bolts attaching the bracket to the meter
body
Figure 9. Wall Mount
21-490000-905A, 905B
2.9 (74)
6.0 (152)
6.9 (175)
Wall or Stud
Mounting Bracket
3
/16 (5) hole
Dimensions are in inches (millimeters)
4833 Rev AA.fm Page 10 Wednesday, January 14, 2004 3:35 PM
Quick Installation Guide
00825-0100-4833, Rev AA
January 2004
Rosemount Eagle Eye
STEP 2 CONTINUED...
Flush Panel
The meter can be flush mounted in panels
1
/16 to
1
/4-in. (2 to 6 mm)
thick. The exact panel cutout size is 4
3
/4-in. (12 mm) high by 6
7
/16-in.
(16.5 mm) wide. Clips are furnished for flush panel mounting.
Figure 10. Flush Panel Mount
21-490000-906B
Washer
Screw
Clip
1
/16 to
3
/8 (2 to 9.5)
Dimensions are in inches (millimeters)
4833 Rev AA.fm Page 11 Wednesday, January 14, 2004 3:35 PM
Quick Installation Guide
00825-0100-4833, Rev AA
January 2004
Rosemount Eagle Eye
STEP 3: OPERATION
Equalize the system
1. Mount the Eagle Eye Indicator in the vertical position, but do not
connect it to the Annubar.
2. Remove the cover access plate by unscrewing the two front cover
screws and gently prying the cover from the right side. (This give
access to the equalizer valve)
The equalizer valve provides a path between the high- and low-
pressure sides of the meter.
Clockwise rotation of the screw closes the valve
Counter-clockwise rotation of the screw opens the valve
Full closed to full open required 1 ½ to 2 turns
The equalizer valve is used during the bleeding process,
(see “Bleeding or Draining the System”)
NOTE
Portable meters come with an external equalizer knob (standard).
Figure 11. Equalizer Valve
Bleed Valve
Cover Access Plate
Equalizer Valve
Front Cover Screw (2)
21-490000-909A
4833 Rev AA.fm Page 12 Wednesday, January 14, 2004 3:35 PM
Quick Installation Guide
00825-0100-4833, Rev AA
January 2004
Rosemount Eagle Eye
STEP 3 CONTINUED...
Instrument Connection
To the Rosemount 485 Annubar
1. Close all Annubar valves.
2. Connect the meter tubing to the Annubar.
To the Rosemount Eagle Eye
1. Close all system valves.
2. Insure that all connections are installed correctly.
3. Secure the tubing to the meter.
4. Use an open-end wrench to hold the meter fittings from rotating
while making the connections.
Figure 12. Connection
CAUTION
Be sure to connect the HI-pressure side of the Eagle Eye meter to the
HI-pressure side of the Annubar. The HI-pressure side is clearly
marked on the Annubar and the Eagle Eye Indicator.
21-490000-910A
Open End Wrench
4833 Rev AA.fm Page 13 Wednesday, January 14, 2004 3:35 PM
Quick Installation Guide
00825-0100-4833, Rev AA
January 2004
Rosemount Eagle Eye
STEP 3 CONTINUED...
Bleeding or Draining the System
After all connections are installed and secured, the system should be
bled of all air. In air applications, any water or condensate must be
drained from the connecting tubing and meter before taking readings.
In water applications, all air in the connecting lines and meter must be
bled with cool water.
1. Install plastic drain tubing onto the bleed valves and run tubing to a
drain.
2. Open the equalizer valve.
3. Open both bleed valves one turn-counter clockwise.
4. Open the Annubar LO-pressure valve slowly and just enough to
send a slow, but constant stream of water through the Eagle Eye
Indicator.
5. Similarly open the Annubar HI pressure valve.
6. When the liquid exiting the bleed valve is free of air, close the
LO-pressure bleed valve first. Close the HI-pressure bleed valve
last.
7. Slowly close the equalizer valve.
8. Replace the access plate.
NOTE
The pointer may register above zero even though the equalizer is
open. This indicates the pressure drop across the equalizer.
The meter must be bled after each system shutdown.
4833 Rev AA.fm Page 14 Wednesday, January 14, 2004 3:35 PM
Quick Installation Guide
00825-0100-4833, Rev AA
January 2004
Rosemount Eagle Eye
STEP 4: CALIBRATION
The Eagle Eye is calibrated at the factory and should not need to be
recalibrated in the field. The full scale calibration point is shown on the
backside of the meter. (See the slot opposite “Scale/Reading” on the
black and silver tag.)
STEP 5: REMOVAL FROM SERVICE (IF NEEDED)
1. Shut down the system valves at the Annubar.
2. Open the equalizer by turning the equalizer valve counter
clockwise
3. Disconnect all the tubing if necessary
CAUTION
If the Eagle Eye is going to be subject to freezing temperatures, all
water must be drained or damage will occur
To prevent injury, when the Annubar sensor is removed from the pipe,
eliminate any pipeline pressure and drain the pipeline before
loosening the Pak-Lok compression fitting.
APPROVAL
Rosemount 415 Fire Pump approved by Factory Mutual
4833 Rev AA.fm Page 15 Wednesday, January 14, 2004 3:35 PM
Quick Installation Guide
00825-0100-4833, Rev AA
January 2004
Rosemount Eagle Eye
4833 Rev AA.fm Page 16 Wednesday, January 14, 2004 3:35 PM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Rosemount Eagle Eye Quick start guide

Type
Quick start guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI