Salvajor Disposers 750 TVR Datasheet

Type
Datasheet
A Water Trough Conveyor
and Disposing System
Recirculated Water used by the system
for scrapping reduces water and sewer
costs by thousands of dollars per year
compared to a fresh water trough. The
TroughVeyor consumes only 7 gallons
of fresh water per minute.
Trough Water Velocity with the
TroughVeyor is 70 gallons per minute.
This velocity swiftly propels food waste
down the trough and into the disposer with
no additional hand movement, leaving both
hands free for high-volume scrapping.
The TroughVeyor lets you keep up with
large conveyor or flight dishmachines.
Design Flexibility is offered by the
TroughVeyor as troughs can turn one or
more corners and have wider troughs for
soaking problem dishes.
Wider Troughs are made possible by high
water velocity that lets you soak problem dishes
or add optional gusher heads to pre-rinse
compartmented trays
T Y P I C A L I N S T A L L A T I O N S
Job: Item No.:
Model TVR
Model TVL
Model TVL
Model TVR
TroughVeyor
Model TVL
Model TVL, left hand operation
Model TVR, right hand operation
Model TVL
ALL CONNECTIONS ARE TO BE MADE BY
QUALIFIED PERSONNEL WHO WILL OBSERVE
ALL LOCAL AND NATIONAL CODES.
D
B
C
F
E
A
19
15
/16"
(50.66)
20
1
/2"
(52.15)
25
1
/16"
(63.66)
34
1
/2"
(87.63)
E
F
A
B
25
13
/16"
(65.62)
1
1
/4"
(3.1)
40
7
/8"
(103.78)
34
1
/2"
(87.63)
10
9
/16"
(26.77)
8
3
/4"
(22.26)
2
3
/4"
(6.99)
5
5
/16"
(13.56)
29
15
/16"
(76.04)
23
1
/4"
(59.03)
20
3
/16"
(51.31)
12"
(30.48)
14"
(35.63)
11
1
/2"
(29.21)
7
1
/2"
(18.98)
1"
(2.54)
5
7
/16"
(13.84)
6
3
/16"
(15.74)
33
3
/16"(84.26)
Adjustable to
36
3
/16"(91.92)
AIR GAP
TROUGH
OPENING
3
1
/8"
(7.94)
E
NOTE: Dimensions in parenthesis are in centimeters
WATER FLOWS RIGHT
-
TO
-
LEFT
TroughVeyor Model TVL
(
LEFT HAND OPERATION
)
NOTE:
Allow 6"
from back
of trough
to wall for
recirculation
piping.
NOTE:
Maximum length for 8 inch wide trough is 24 feet.
Maximum length for 12 inch wide trough is 18 feet.
8
7
/8"
(
22.54
)
33
1
/2"
(
85.09
)
(TABLE CUT-OUT SIZE)
DRAIN PIPING
(
NF
)
=
NOT FURNISHED
DRAIN
PIPING
(
NF
)
2"TANK
RESERVOIR
DRAIN PIPING
(
NF
)
GUSHERHEAD
(
OPTIONAL
)
GUSHERHEAD
(
OPTIONAL
)
DIFFUSER
1
1
/2" VALVE
(
NF
)
1
1
/2"
RECIRCULATION
PIPING
(
NF
)
3
/4" PIPING
(
NF
)
45
O
11
1
/2"
(
29.21
)
8
3
/8"
(
21.27
)
8
7
/8"
(
22.54
)
7
3
/8"
(
18.73
)
NOTE:
Maximum number
of gusher heads is 3.
2" tank reservoir drain can be
run separately or be tied in
with the disposer drain.
Model TVL
DRAIN PIPING
3
/4" VALVE
(
NF
)
TROUGH
SECTION
3" MIN.
DEPTH
DIFFUSER
LOCKNUT
GASKET
TroughVeyor Legend
Disposer outlet can be rotated at most
any angle by rotating disposer.
Rubber drain accepts 2” piping or 3”
piping by removing drain insert.
Tank reservoir drain – Plumb 2” piping
from valve to floor drain or connect to
disposer drain piping ahead of P trap.
Disposer electrical connection.
Disposer to control connection.
Incoming electrical connection.
Hot and cold water connection. 1/2” NPT
A
B
C
D
E
F
Trough matching
flange layout
TABLE CUT-OUT: 8
7
8(22.54) x33
1
2(85.09)
WATER FLOWS LEFT
-
TO
-
RIGHT
TroughVeyor Model TVR
(
RIGHT HAND OPERATION
)
D
B
C
F
E
A
19
15
/16"
(50.66)
18
13
/16"
(47.74)
25
1
/16"
(63.66)
34
1
/2"
(87.63)
E
A
B
25
13
/16"
(65.62)
1
1
/4"
(3.1)
40
7
/8"
(103.78)
34
1
/2"
(87.63)
10
9
/16"
(26.77)
8
3
/4"
(22.26)
2
3
/4"
(6.99)
5
5
/16"
(13.56)
29
15
/16"
(76.04)
23
1
/4"
(59.03)
20
3
/16"
(51.31)
12"
(30.48)
14"
(35.63)
11
1
/2"
(29.21)
7
1
/2"
(18.98)
1"
(2.54)
5
7
/16"
(13.84)
6
1
/4"
(15.82)
33
3
/16"(84.26)
Adjustable to
36
3
/16"(91.92)
AIR GAP
TROUGH
OPENING
3
1
/8"
(7.94)
E
F
NOTE: Dimensions in parenthesis are in centimeters
NOTE:
Allow 6"
from back
of trough
to wall for
recirculation
piping.
NOTE:
Maximum length for 8 inch wide trough is 24 feet.
Maximum length for 12 inch wide trough is 18 feet.
1
1
/2" VALVE
(
NF
)
1
1
/2"
RECIRCULATION
PIPING
(
NF
)
3
/4" PIPING
(
NF
)
3
/4" VALVE
(
NF
)
8
7
/8"
(
22.54
)
33
1
/2"
(
85.09
)
(
TABLE CUT-OUT SIZE
)
2"TANK
RESERVOIR
DRAIN PIPING
(
NF
)
GUSHERHEAD
(
OPTIONAL
)
GUSHERHEAD
(
OPTIONAL
)
DIFFUSER
45
O
TROUGH
SECTION
3" MIN.
DEPTH
DIFFUSER
LOCKNUT
GASKET
11
1
/2"
(
29.21
)
8
3
/8"
(
21.27
)
8
7
/8"
(
22.54
)
7
3
/8"
(
18.73
)
Model TVR
DRAIN PIPING
2" tank reservoir drain can be
run separately or be tied in
with the disposer drain.
DRAIN PIPING
(
NF
)
=
NOT FURNISHED
DRAIN
PIPING
(
NF
)
NOTE:
Maximum number
of gusher heads is 3.
ALL CONNECTIONS ARE TO BE MADE BY
QUALIFIED PERSONNEL WHO WILL OBSERVE
ALL LOCAL AND NATIONAL CODES.
TroughVeyor Legend
Disposer outlet can be rotated at most
any angle by rotating disposer.
Rubber drain accepts 2” piping or 3”
piping by removing drain insert.
Tank reservoir drain – Plumb 2” piping
from valve to floor drain or connect to
disposer drain piping ahead of P trap.
Disposer electrical connection.
Disposer to control connection.
Incoming electrical connection.
Hot and cold water connection. 1/2” NPT
A
B
C
D
E
F
TABLE CUT-OUT: 8
7
8(22.54) x33
1
2(85.09)
Trough matching
flange layout
ELECTRICAL
CONSTRUCTION MODELS AVAILABLE
PLUMBING
Stainless Steel Components
Salvage Basin
Disposer Safety Cover
Adjustable Legs
Control Panel
Pre-wired NEMA 4 Panel
Watertight Conduit/Fittings
Separate Component Grounding
Thermally Protected Motors
Totally Enclosed Motors
Line Voltage Disconnect
Disposer Safety Switch
24 Volt Safety Circuitry
Corrosion Resistant Components
Automatic Water Blender
Solenoid Valves
Unions
Check Valves
Incoming Water Valves
Non-clogging Pump Design
Backflow Prevention Device
Quick Opening Drain Valve
Left-Hand Right-Hand Disposer Lbs.
300 TVL
300 TVR 3
HP 327
500 TVL
500 TVR 5
HP 335
750 TVL
750 TVR 7
1
2 HP 343
ACCESSORIES
Remote Start-Stop Button
Remo
te Mounting Bracket
Corre
ctional Package
Gush
er Heads
VOLTAGES AVAILABLE
(
SPECIFY EXACT OPERATING VOLTAGE
)
208V
230V
460V,
60 Cycle, 3 Phase
Disposer 3
-
7
1
2 HP 208
-
230
-460V
Pump
3
4 HP 208
-
230
-460V
Separator
1
6 HP 208
-
230
-460V
FULL LOAD AMPS
UTILITIES REQUIRED
208, 230 or 460 Volt, 60 cycle, 3 phase electric service,
3
4" hot and cold water supply and reduce to
1
2" at
connection. 2" or 3 waste line, 2" tank reservoir drain.
(Specifications subject to change without notice.)
SAMPLE SPECIFICATIONS
Unit shall be TroughVeyor, a complete food waste
conveying and disposing system with recirculating
water as manufactured by Salvajor.
Model
_____ TV__ , ____Volts, ___Hz, ___Phase.
Furnished with a pre-wired control panel and
Stainless Steel NEMA 4 watertight enclosure.
Salvajor TroughVeyor System
MODEL TV
S P E C I F I C A T I O N S
The Salvajor Company 4530 East 75th Terrace Kansas City, Missouri 64132-2081, USA
1
-
800
-
SALVAJOR (816) 363
-
1030 FAX
:
1
-
800
-
832
-
9373
www.salvajor.com Email: sales@salvajor.com service@salvajor.com
Manufacturers of Commercial Food Waste Disposing Systems since 1944
Printed in USA
Form No.TV-9-BH
Disposer
not included
in listing.
TOTAL FULL LOAD AMPS THREE PHASE
MODEL 208V 230V 460/480V Total HP
300-TV 12.64 11.66 5.83 3.92
500-TV 17.64 16.16 8.13 5.92
750-TV 23.64 21.66 10.83 8.42
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Salvajor Disposers 750 TVR Datasheet

Type
Datasheet

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI