CLEAN WATER STORE GPM 110v User guide

Type
User guide
WonderLightUVInstallationGuideRev050414
WonderLightUVSterilizerInstallationGuide
ThankyouforpurchasingaCleanWaterSystem!Withproperinstallationandalittleroutinemaintenance
yourUVsterilizerwilllastformanyyears.
Questions?
Callustollfree:18886005426or18314628500
Emailus:[email protected]
Seemoreinformationonourwebsite:www.cleanwaterstore.com/resources
Clean Water Made
Easy
WonderLightUVInstallationGuideRev050414
PreInstallation
1. NotethatforUVtobeeffectivethewatershouldbelow:
a. Lessthan7grainspergallonofhardness,orlessthan120PPM)
b. Freeofcolorandcrystalclear.
c. Ironshouldbelessthan0.3mg/L.
d. Manganeseshouldbelessthan0.05mg/L
e. pHrangeshouldbe6.5to9.5
2. Ifyouaregoingtobeturningoffthewatertothehouseandyouhaveanelectricwaterheater,
shutoffthepowertothewaterheaterbeforebeginninginstallationincasewaterheateris
accidentallydrained.
3. PickasuitablelocationforyourUVSterilizer.Itisbesttomountonawall,whereyoucanbe
suretoremoveoneendoftheUVwithenoughspacetocompletelyremoveandinstalltheUV
lamp(bulb).Choosealocationwhereitwon’tbeexposedtofreezingtemperatures.A
minimumof10PSIisrequired.Maximumpressureis100PSI.
4. Getallofyourplumbingpartstogetherbeforebeginninginstallation.Installationtypicallytakes
1to4hours.Reviewyourpackinglistandmakesureyouhavereceivedallthepartsbefore
beginninginstallation.
BestPracticesforPiping&DrainInstallation
1. Seetypicalinstallationonpage2,Figure1
2. InstallUVwithstainlesssteelflexiblelines,oruseapipeunionsoUVcanbeeasilyremoved
laterifneeded.
3. Ifyouwillbeusingcopperpiping,donotsweatthecopperpipedirectlyontheUV.
4. IfyouaregoingtobeusingPVCpipe,donotconnectPVCfittingsdirecttoUVsterilizer,asthe
UVrayscandegradethePVCpipe.UseastainlesssteellinetoisolatethePVCfromtheUV
sterilizeristhebestpractice.
5. Installaseriesof3ballvalvestocreateabypassaroundtheUVasshowninFigure1ifdesired.
6. Installa5micronprefilterpriortoUVsterilizer(optional)toremoveveryfineparticlesthat
mightblockthetransmissionofUVraysintothewater.


WonderLightUVSterilizerInstallationGuide
Page3WonderLightUVInstallationGuidewww.cleanwaterstore.comRev040814
Fig1
Installation:
1. InstallUVsterilizerinpiping.
2. Add½to1cupofbleachtoprefiltertoUV,orshockwelloradddirectlytopipingifpossible.
3. FlushpipinginhomeafterUVwithchlorinatedwatertosanitizepipesinthehome.
4. Forbadlycontaminatedpipingorpipingwithsedimentorscale,thisproceduremayneedtobe
repeatedtokillallbacteriaafterUVuponstartup.
5. TurnonUVlampandnoteGREENlightonballast.ThismeanstheUVlamp(‘lamp’iswhatthe
UVlightbulbisoftenreferredto)isoperatingnormal,andwaterflowingthroughUVis
sterilized.
WonderLightUVSterilizerInstallationGuide
Page4WonderLightUVInstallationGuidewww.cleanwaterstore.comRev040814
6. IfballastREDlightislit,thismeansthelampisnotoperating.
7. NOTE:IFLAMPISBURNEDOUT,ALARMWILLSOUNDANDREDLIGHTWILLBELITONTHE
BALLAST.
Maintenance:
ChangeUVlampandcleanquartzsleevewithadampclothonceevery12months.
WhenchangingUVlamp,werecommendthehouseholdpipingissanitizedwithchlorineorhydrogen
peroxide.