ICP LP-5231 is a powerful and versatile embedded controller that offers a wide range of features and capabilities. With its powerful 720 MHz CPU, 512 MB of SRAM, and 256 MB of Flash, the LP-5231 can handle even the most demanding applications. It also features a variety of I/O options, including 4 serial ports, a 10/100/1000M Ethernet port, and an I/O expansion bus. The LP-5231 is ideal for use in a variety of industrial automation and control applications.

ICP LP-5231 is a powerful and versatile embedded controller that offers a wide range of features and capabilities. With its powerful 720 MHz CPU, 512 MB of SRAM, and 256 MB of Flash, the LP-5231 can handle even the most demanding applications. It also features a variety of I/O options, including 4 serial ports, a 10/100/1000M Ethernet port, and an I/O expansion bus. The LP-5231 is ideal for use in a variety of industrial automation and control applications.

The package includes the following items:
1. Power Supply: +10 ~ +30 V
DC.
(Ex: DP-665)
2. Ethernet Hub. (Ex: NS-205)
3. Make sure your PC has workable serial port and network
settings.
For LP-5231
English/ Mar 2015/ Version 1.0
What’s in
the shipping
package?
Preparations for devices
1
LP
5231
Quick Start
Quick Start
(This Document)
LP-5231
Software CD CA-0910 Cable
1. AM3352, 720 MHz CPU
2. 512 MB SRAM and 256 MB Flash
3. Linux kernel 3.2.14
4. Hard Real-Time Capability
5. 64-bit Hardware Serial Number for Software Protection
6. I/O Expansion Bus
7. 10/100/1000M Ethernet Port
8. 4 Serial Ports (RS-232/485)
Console Port RS-232 (RxD, TxD and GND); Non-isolated
ttyO4 RS-232 (RxD, TxD and GND); Non-isolated
ttyO2 RS-485 (Data+, Data-); Non-isolated
ttyO5 RS-485 (Data+, Data-); 2500 VDC isolated
9. Operating Temperature: -25 ~ +75°C
Hardware
Introduction
2
LP
5231
Quick Start
1. Connect both the LP-5231 and your computer through
the “Console Port”, and power the LP-5231 on.
2. Using the serial terminal software(ex Putty or others) and
set the baud rate “115200” to connect to the device.
Fig 4-1 Console Connection
3. Type default ID “root” to login.
Console Connection
3
LP
5231
Quick Start
Console
Port
Serial
Port
1.
After user follow step 4 “Console Connection” to connect to
the device bash terminal, user can change the default network
setting:
2.
If user would set static IP(10.1.0.107)netmask(255.255.0.0)
and gateway(10.1.0.254), please refer to below example:
3.
If user would set dynamic IP, please refer to below example:
4.
After user set the device’s IP, user can use the Putty(or other
ssh client software) to connect to the LP-5231:
Fig 5-1 SSH Connection
Network Configuration
4
LP
5231
Quick Start
IP 192.168.255.1
Netmask 255.255.255.0
Gateway 192.168.255.254
User ID root
Password (no Password)
1.
User can use below the i-Talk utility to control LP-5231
or ICP DAS XV-Board:
Table 6-1 i-Talk Command
1.
Systemd Support
“Systemd” is a system and service manager for Linux
operating systems. User can start/stop/enable/disable
software service by using command “systemctl”.
LP
-
5231 i
-
Talk Command
Application Support
Instruction Function Discription
setxvdo Set digital output value to XV-Board
setxvao Set analog output value to XV-Board
getxvdi Get digital input value from XV-Board
getxvai Get analog input value from XV-Board
getxvdo Get digital output value from XV-Board
getxvao Get analog output value from XV-Board
setmodbus Set the modbus device
getmodbus Get the status of modbus device
rsw Get the rotary switch ID
ipv4set Set network configuration
5
LP
5231
Quick Star
t
2.
Web Server
The web server daemon “lighttpd” has been built in the
LP-5231 and it will be started automatically at boot time.
3.
SFTP(or SCP)
The LP-5231 had supported SFTP(or SCP), user can transfer
the file from Windows(or Linux). For examples, user use
Windows Program “WinSCP” to access the device over
network(please refer to Fig 7-1).
Fig 7-1 WinSCP
4.
Share Memory I/O for XV-Board
User can use the command “shmioserver” and “shmioclient”
to control the XV-Board. User can refer to below steps:
Step 1:Enable share memory server
Fig 7-2 shmioserver
6
L
P
5
2
3
1
Quick Start
Step 2: Using client command to control XV-Board. For
example, using “shmioclient” to enable XV-116 DO(address
0x0001).
Fig 7-3 shmioclient
5.
OPKG Package Manager
The “opkg” utility is a lightweight package manager used to
download and install OpenWrt packages from local package
repositories or ones located in the Internet.
6.
XFCE GUI Desktop
Angstrom Linux provides the XFCE package, after user type
“root” to login, the local terminal would execute the XFCE
Desktop.
Fig 7-4 XFCE Desktop
7
LP
5231
Quick Start
LinPAC-5231 Product Page:
http://www.icpdas.com/root/product/solutions/pac/linpac/lp-52xx.html
LinPAC-5231 Document Download:
http://ftp.icpdas.com.tw/pub/cd/linpac/napdos/lp-5000/lp-52xx/lp-
5231/user_manual/
LinPAC-5231 Software Download:
http://www.icpdas.com/root/product/solutions/pac/linpac/linpac-
5000_download.html
NS-205 and DP-665 Product Page (optional):
http://www.icpdas.com/products/Switch/industrial/ns-205.htm
http://www.icpdas.com/products/Accessories/power_supply/dp-665.htm
ICP DAS Web Site: http://www.icpdas.com
Contact Us (E-Mail):
Copyright @ 201
5
by ICP DAS Co., Ltd. All Rights Reserved.
8
8
Product Related Information
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

ICP LP-5231 Quick Start

Type
Quick Start

ICP LP-5231 is a powerful and versatile embedded controller that offers a wide range of features and capabilities. With its powerful 720 MHz CPU, 512 MB of SRAM, and 256 MB of Flash, the LP-5231 can handle even the most demanding applications. It also features a variety of I/O options, including 4 serial ports, a 10/100/1000M Ethernet port, and an I/O expansion bus. The LP-5231 is ideal for use in a variety of industrial automation and control applications.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI