Eurolux D101AC Owner's manual

Type
Owner's manual

Eurolux D101AC is a crystal glass downlight suitable for both commercial and domestic use. It requires a transformer (CO76 / CO79 excluded) and is compatible with a dimmer switch (CO49 / CO50 excluded). The D101AC has an IP rating of IP22, meaning it is protected against solid foreign objects of 50mm Ø and greater, but not against water. It is not suitable for outdoor use and should be installed by a qualified electrician. The maximum ambient temperature range for the D101AC is 20ºC - 40ºC. It has a cut-out diameter of 75mm and dimensions of (D) 23mm X (Ø) 89mm.

Eurolux D101AC is a crystal glass downlight suitable for both commercial and domestic use. It requires a transformer (CO76 / CO79 excluded) and is compatible with a dimmer switch (CO49 / CO50 excluded). The D101AC has an IP rating of IP22, meaning it is protected against solid foreign objects of 50mm Ø and greater, but not against water. It is not suitable for outdoor use and should be installed by a qualified electrician. The maximum ambient temperature range for the D101AC is 20ºC - 40ºC. It has a cut-out diameter of 75mm and dimensions of (D) 23mm X (Ø) 89mm.

Clear Crystal Downlight
D101 / D102 Excluding: 1 X MR16 maximum 50W
ILLUSTRATIONS
MODEL
MODELMODEL
ENVIRONMENTAL PROTECTION
Waste electrical & Electronic equipment regulations requires that any of our products showing this mark-
ing must not be disposed of with other household or commercial waste. To prevent possible harm to the
environment or human health from uncontrolled waste disposal, please separate any such products from
other waste types and recycle it responsibly at your local facilities.
D101AC / D102AC
D650 / D651
PRODUCT CODE
MODEL
Cape Town - 9 Racecourse Road, Milnerton, 7441
Johannesburg - 10 Milkyway Avenue, Linbro Business Park, Sandton, 2065
www.eurolux.co.za
Please read instructions before commencing installation and retain for
future reference.
1
5
3
50mm
200mm
200mm
0.5m
2
220/240V
12V
• Fitting: Aluminium & Crystal Glass.
• Lamp type: D101 / D102 Excluding: 1 X MR16 maximum 50W.
• Input Voltage: 220 - 240V ~ 50/60Hz.
Output Voltage: 12V.
• Requires a transformer (Recommended: CO76 / CO79 excluded).
• Dimmer switch (Recommended: CO49 / CO50 excluded).
• Protection against electric shock: Class 3. SELV does not require earthing.
• IP Rating: IP22. Protected against solid foreign objects of 50mm Ø and greater. Not
protected against water.
• Commercial / domestic use.
• Not suitable for outdoor use.
• Maximum ambient temperature range: 20ºC - 40ºC.
• Dimensions:
D101: (D) 23mm X (Ø) 89mm.
D102: (L)89mm x (W)89mm x (D) 23mm.
• Cut-out: D101 / D102: (Ø) 75mm.
Before installation always ensure the power supply is turned off.
1. Cut a hole in the ceiling as per “cut out”.
2. Connect mains to the low voltage transformer 230V on primary side, and the luminaire to
the 12V secondary side.
3. Hold both clips on either side of downlight upwards and insert downlight into ceiling hole
ensuring the mains lead is not trapped.
4. Push tting upwards to snap rmly into position, ush with ceiling.
5. Insert the lamp by locating the pin connection holes within the lamp
holder, gently pushing the lamp into the holder and twisting into place.
6. Reconnect power.
NOTE: Always allow the lamp to cool sufciently before changing.
NOTE: To avoid heat transfer from downlight, allow a minimum gap of about 200mm in height
from downlight to ceiling / any materials above the downlight and 50mm all around the sides
of the downlight.
NOTE: Ensure that the transformer is a minimum of 200mm away from the light source.
D101AC - attachments:
If the external exible cable or cord of this luminaire is damaged, it should be exclusively
replaced by the manufacturer or his service agent or a similar qualied person in order to
avoid a hazard.
To ensure that you get maximum longevity and maximum use out of your luminaire, please
observe the following safety instructions.
Electrical products can cause death, injury, or damage to property.
Installation of the luminaire must be carried out by a qualied electrician, in accordance with
SANS 10142. On completion of installation, ensure that the Certicate of Compliance is
updated.
• Ensure that the dimmer is compatible with the transformer.
• Before connecting the luminaire, ensure that voltage indicated on the rating label
corresponds with the mains voltage in your home.
• When changing the lamp, ensure that the power is turned off.
• Ensure that the correct lamp type and wattage is tted.
• This luminaire is checked in full for conformity to the quality standards and safety
requirements.
• The manufacturer / supplier is not responsible for any damage of properties and persons,
caused by the incorrect use or installation of the luminaire.
• Should you be unsure of how to install this luminaire correctly, please consult a professional
electrician or your supplier for assistance.
• Ensure all items/ components, threads and screws are tightly secured.
IMPORTANT:
• Tampering with this luminaire, I.E. Using silicon sealers or incorrect cabling, will invalidate
your warranty.
• When the protection glass is damaged, it should be replaced immediately. The luminaire
must not be used without the protection glass.
• Please check whether the connection of the power cord is safe and reliable before
installation.
• If your mains wiring differs in any way from diagram, consult a qualied electrician.
SPECIFICATIONS
IMPORTANT SAFEGUARDS
INSTALLATION
CLEANING
• Before cleaning always ensure the power supply is turned off.
• Do not immerse the luminaire in water.
• No abrasive products, solvents, detergent may be used to clean this luminaire.
• Ensure that the tting does not come in contact with corrosive chemicals, etc.
• Use a soft cloth to clean.
Always ensure that the mains supply voltage is correct.
Always replace the lamp with one of an identical rating and wattage.
• Choking hazard: May contain small parts. Keep away from children.
• Do not insert your ngers or any part of your body into the electrical contact and sockets of
this product whilst it is connected to the electrical supply.
• Item may vary slightly from the picture on the carton.
• Coastal humidity may effect the longevity of the luminaire.
  • Page 1 1
  • Page 2 2

Eurolux D101AC Owner's manual

Type
Owner's manual

Eurolux D101AC is a crystal glass downlight suitable for both commercial and domestic use. It requires a transformer (CO76 / CO79 excluded) and is compatible with a dimmer switch (CO49 / CO50 excluded). The D101AC has an IP rating of IP22, meaning it is protected against solid foreign objects of 50mm Ø and greater, but not against water. It is not suitable for outdoor use and should be installed by a qualified electrician. The maximum ambient temperature range for the D101AC is 20ºC - 40ºC. It has a cut-out diameter of 75mm and dimensions of (D) 23mm X (Ø) 89mm.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI