Includes
Constant Force
Technology
ENGLISH
ASSEMBLY INSTRUCTIONS
For the latest User Installation Guide please visit: www.ergotron.com
2 of 18
888-45-176-W-06 rev.R • 09/14
70°
180°
360°
180°
13"
(330 mm)
0 - 5 lbs
(0 - 2.3 kg)
180° 360°
180°
13" (330 mm)
1.38" - 3.75"
(35-95 mm)
50 lbs (22.7 kg)
90°
5 - 25 lbs*
(2.3 - 11.3 kg)
< 4.5” (114 mm)
8.5” (216 mm)
ENGLISH
* The lower most range of motion for vertical lift is
decreased up to 4.5” (114 mm) when arm is adjusted to
hold over 20lbs (9 kgs).
3 of 18
888-45-176-W-06 rev.R • 09/14
AB CD
1
2
3
4
5
6
7
8
9
10
M4 x 10mm
4x
M4 x 10mm
4x
4mm
1x
1x
M3 x 6mm
2x
2x
2x
1x
1x
8x
10-24 x 1/2"
12x
7mm
2
1
1x
Ø 3/16" (5 mm)
Wood
Madera
Bois
Solide Holzbalkenträger
Massief Houten Pilaren
Due montanti in legno massiccio
1x
3x
1x
1x
1x
2x
2x
1x
1x 1x
2x
1x
2x
2x
2x
2x
Ø 1/2” (12.7 mm)
Hollow Wall
Pared
Mur
Wand
Muur
Parete
1/4-20 x 1/2"
9x
2x
M10 x 16mm
14x
2x
Studs ≥ 25 gauge steel
Pernos de acero de calibre ≥ 25
Goujons ≥ calibre25 en acier
Bolzen ≥ Blechlehre Nr. 25
Verbindingsbouten ≥ 25 gauge staal
Prigionieri in acciaio spessore ≥ gauge 25 (0,556 mm)
Reglar ≥ 25-gauge stål
1/4-20 x 2"
14x
7x
7x
M4.2 x 25mm
4x
4x
4x
1x
1x
4x
2.5mm
1/8”
6mm
4x
4x
M4 x 8mm
1x
1x
1x
2x
M4 x 14mm
ENGLISH
Stud Finder
Components
Tools Needed
4 of 18
888-45-176-W-06 rev.R • 09/14
1
21”
(533 mm)
5’0” - 6’4”
(152-193cm)
5’0” - 6’1”
(152-185cm)
5’0” - 6’1”
(152-185cm)
17.5”
(445mm)
31.5”
(800mm)
21”
(533 mm)
21”
(533 mm)
31.5”
(800mm)
47”
(1194mm)
< 16.5”
(419mm)
21”
(533 mm)
5’0” - 6’4”
(152-193cm)
21.4”
(544mm)
35”
(889mm)
< 20.4”
(518mm)
< 30.5”
(775mm)
35.4”
(899mm)
50.5”
(1283mm)
< 34.4”
(874mm)
6”
(152 mm)
14.7”
(373mm)
2.5”
(63mm)
17.7”
(449mm) 20.7”
(526mm)
0.6”
(14mm)
2”
(50mm)
8.2”
(207mm)
ENGLISH
This mounting height is a recommendation for an ergonomic workstation that accommodates user heights of 5'0"-6'1"
(152-185cm) when set up for standing and user heights of 5’0”-6’4” (152-193cm) when set up for sitting.
If user heights are di erent than this, you should change mounting height to accommodate user heights. (Change mount-
ing height one inch for every one inch di erence in user heights).
Determine mounting location:
Mounting height assumes
there is a 6” (152 mm) dis-
tance between the center
of your monitor mounting
holes and the top of the
screen. If your distance is
smaller, you should increase
mounting height accord-
ingly, if your distance is
larger, you should decrease
your mounting height ac-
cordingly.
Top view showing range of motion when pulled out from the wall.
Front view with arm pushed back against the wall.
Mounting Height for Ergonomic Workstation
5 of 18
888-45-176-W-06 rev.R • 09/14
2
Requires minimum material thickness of 5/8” (16 mm).
Requiere un grosor mínimo de 16 mm.
Epaisseur minimum de 16 mm.
Requer uma espessura mínima de 5/8” (16 mm).
Mit einer Materialdicke von mindestens 16 mm.
Vereist een minimale materiaaldikte van 1.6 cm.
Richiede uno spessore del materiale non inferiore a 16 mm.
6
≥ 5/8”
Sheetrock
Sheetrock
Plaque de plâtre
Rigipsplatte
Sheetrock
Cartongesso
Gipsskiva
7
Wood
Madera
Bois
Solide Holzbalkenträger
Massief Houten Pilaren
Due montanti in legno massiccio
Hollow Wall
Pared
Mur
Wand
Muur
Parete
Studs ≥ 25 gauge steel
Pernos de acero de calibre ≥ 25
Goujons ≥ calibre25 en acier
Bolzen ≥ Blechlehre Nr. 25
Verbindingsbouten ≥ 25 gauge staal
Prigionieri in acciaio spessore ≥ gauge 25 (0,556 mm)
Reglar ≥ 25-gauge stål
ENGLISH
CAUTION: Make sure the wall mount bracket is level,
ush and snug to the wall surface. DO NOT OVERTIGHT-
EN THE BOLTS.
WARNING: Ensure that the wall structure is capable
of supporting four times the total weight of mounted
equipment. Mounting to wall surfaces that do not meet
this criteria may result in an unstable, unsafe condition
which could lead to personal injury and/or property
damage. Consult a construction professional if you
have any doubt about what this means in regard to
your particular application.
6 of 18
888-45-176-W-06 rev.R • 09/14
Wood
Madera
Bois
Solide Holzbalkenträger
Massief Houten Pilaren
Due montanti in legno massiccio
Studs ≥ 25 gauge steel
Pernos de acero de calibre ≥ 25
Goujons ≥ calibre25 en acier
Bolzen ≥ Blechlehre Nr. 25
Verbindingsbouten ≥ 25 gauge staal
Prigionieri in acciaio spessore ≥ gauge 25 (0,556 mm)
Reglar ≥ 25-gauge stål
8
Ø 3/16" (5 mm)
x 5
a
ef
c b
d
3
Studs ≥ 25 gauge steel
Pernos de acero de calibre ≥ 25
Goujons ≥ calibre25 en acier
Bolzen ≥ Blechlehre Nr. 25
Verbindingsbouten ≥ 25 gauge staal
Prigionieri in acciaio spessore ≥ gauge 25 (0,556 mm)
Reglar ≥ 25-gauge stål
7x
7x
ENGLISH
Stud Finder
Wood Stud Mounting
7 of 18
888-45-176-W-06 rev.R • 09/14
Hollow Wall
Pared
Mur
Wand
Muur
Parete
1
2
3
4
bc
de
Ø 1/2"
(12.7 mm)
a
14x
1/4-20 x 2"
Requires minimum material thickness of 5/8” (16 mm).
Requiere un grosor mínimo de 16 mm.
Epaisseur minimum de 16 mm.
Requer uma espessura mínima de 5/8” (16 mm).
Mit einer Materialdicke von mindestens 16 mm.
Vereist een minimale materiaaldikte van 1.6 cm.
Richiede uno spessore del materiale non inferiore a 16 mm.
f
8
3
≥ 5/8”
Sheetrock
Sheetrock
Plaque de plâtre
Rigipsplatte
Sheetrock
Cartongesso
Gipsskiva
14x
ENGLISH
8 of 18
888-45-176-W-06 rev.R • 09/14
a
4x
10-24 x 1/2"
4x
10-24 x 1/2"
3
8x
10-24 x 1/2"
1/4-20 x 1/2"
8x
bc
d
ENGLISH
NOTE: Fasteners may unwind due to vibration caused by movement of mounting solution over
time. Inspect mounting solution for loose fasteners on a routine basis. If desired, apply a light
duty thread locking adhesive to fasteners before installation to prevent back-out.
9 of 18
888-45-176-W-06 rev.R • 09/14
2x
1x
M10 x 16mm
a
4c bd
1/8"
ef g
12x 2x
6mm
ENGLISH
10 of 18
888-45-176-W-06 rev.R • 09/14
M4 x 10mm
M4 x 10mm
4x
4x
M3 x 6mm
5
6a
b
ENGLISH
11 of 18
888-45-176-W-06 rev.R • 09/14
7
8
a
d
jk
efg
4x
bc
hi
4x
M4 x 8mm
1x
ENGLISH
12 of 18
888-45-176-W-06 rev.R • 09/14
94x
ENGLISH
13 of 18
888-45-176-W-06 rev.R • 09/14
10
ENGLISH
NOTE: Leave enough slack in cable to allow full range of motion.
Caution: To avoid the potential to pinch cables it is important to follow the cable routing
instructions in this manual. Failure to follow these instructions may result in equipment
damage or personal injury.
14 of 18
888-45-176-W-06 rev.R • 09/14
11
12
cbd
b
ef
M4.2 x 25mm M4.2 x 25mm
a
abd e
c
12 3
Ø 7/32" (5.6 mm)
ENGLISH
15 of 18
888-45-176-W-06 rev.R • 09/14
4mm
a
WARNING WARNING
13
ENGLISH
WARNING! Stored Energy Hazard: The arm mechanism is under tension and will move up rapidly, on its own, as
soon as attached equipment is removed. For this reason, DO NOT remove equipment unless the arm has been
moved to the highest position! Failure to follow this instruction may result in serious personal injury and/or
equipment damage!
Lift – Up and down
CAUTION: DO NOT overtighten fasteners.
Overtightening may cause damage to your
equipment.
Adjustment Step
Important! You will need to adjust this product after installation is complete. Make sure all your equipment is
properly installed on the product before attempting adjustments. This product should move smoothly and easily
through the full range of motion and stay where you set it. If movements are too easy or dif cult or if product
does not stay in desired positions, follow the adjustment instructions to create smooth and easy movements.
Depending on your product and the adjustment, it may take many turns to notice a difference. Any time
equipment is added or removed from this product, resulting in a change in the weight of the mounted load, you
should repeat these adjustment steps to ensure safe and optimum operation.
Increase Lift Strength
If the mounted weight is too heavy or
this product does not stay up when
raised, then you'll need to increase
Lift Strength:
Decrease Lift Strength
If the mounted weight is too light or
this product does not stay down when
lowered, then you'll need to decrease
Lift Strength:
16 of 18
888-45-176-W-06 rev.R • 09/14
4mm
b
M3 x 6mm
c
d
2.5mm
ENGLISH
Rotate – Portrait/Landscape
Arm Swing – Side-to-side
Tilt – Forward and Backward
CAUTION: DO NOT remove screw. Removing screw may cause damage to
equipment.
Increase Friction
If this product moves too easily, then
you'll need to increase friction:
Decrease Friction
If this product is too dif cult to move,
then you'll need to decrease friction:
Increase Friction
If this product moves too easily, then
you'll need to increase friction:
Decrease Friction
If this product is too dif cult to move,
then you'll need to decrease friction:
17 of 18
888-45-176-W-06 rev.R • 09/14
M4 x 14mm
2x
ENGLISH
How to remove this tilting feature:
Save these screws incase you want to add
this feature later.
18 of 18
888-45-176-W-06 rev.R • 09/14
ENGLISH
For local customer care phone numbers visit: http://contact.ergotron.com
Learn more about ergonomic computer use at:
www.computingcomfort.org
Set Your Workstation to Work For YOU!
Height Position top of screen slightly below eye level.
Position keyboard at about elbow height with wrists  at.
Distance Position screen an arm's length from face—at least 20” (508mm).
Position keyboard close enough to create a 90˚ angle in elbow.
Angle Tilt screen to eliminate glare.
Tilt the keyboard back 10° so that your wrists remain  at.
To Reduce Fatigue
Breathe - Breathe deeply through your nose.
Blink - Blink often to avoid dry eyes.
Break • 2 to 3 minutes every 20 minutes
• 15 to 20 minutes every 2 hours.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18

Ergotron 45-253-026 Installation guide

Category
Flat panel wall mounts
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI